18 resultados para middle managers’ commitment
em Instituto Politécnico do Porto, Portugal
Resumo:
In this paper we study the optimal natural gas commitment for a known demand scenario. This study implies the best location of GSUs to supply all demands and the optimal allocation from sources to gas loads, through an appropriate transportation mode, in order to minimize total system costs. Our emphasis is on the formulation and use of a suitable optimization model, reflecting real-world operations and the constraints of natural gas systems. The mathematical model is based on a Lagrangean heuristic, using the Lagrangean relaxation, an efficient approach to solve the problem. Computational results are presented for Iberian and American natural gas systems, geographically organized in 65 and 88 load nodes, respectively. The location model results, supported by the computational application GasView, show the optimal location and allocation solution, system total costs and suggest a suitable gas transportation mode, presented in both numerical and graphic supports.
Resumo:
Background: Acute respiratory infections are usual in children under three years old occurring in upper respiratory tract, having an impact on child and caregiver’s quality of life predisposing to otitis media or bronchiolitis. There are few valid and reliable measures to determine the child’s respiratory condition and to guide the physiotherapy intervention. Aim: To assess the intra and inter rater reliability of nasal auscultation, to analyze the relation between sounds’ classification and middle ear’s pressure and compliance as well as with the Clinical Severity Score. Methods: A cross-sectional observational study was composed by 125 nursery children aged up to three years old. Tympanometry, pulmonary and nasal auscultation and application of Clinical Severity Score were performed to each child. Nasal auscultation sounds’ were recorded and sent to 3 blinded experts, that classified, as “obstructed” and “unobstructed”, with a 48 hours interval, in order to analyze inter and intra rater reliability. Results: Nasal auscultation revealed a substantial inter and intra rater reliability (=0,749 and evaluator A - K= 0,691; evaluator B - K= 0,605 and evaluator C - K= 0,724, respectively). Both ears’ pressure was significantly lower in children with an "unobstructed" nasal sound when compared with an “obstructed” nasal sound (t=-3,599, p<0,001 in left ear; t=-2,258, p=0,026 in right ear). Compliance in both ears was significantly lower in children with an "obstructed" nasal sound when compared with “unobstructed” nasal sound (t=-2,728, p=0,007 in left ear; t=-3,830, p<0,001 in right ear). There was a statistically significant association between sounds’ classification and tympanograms types in both ear’s (=11,437, p=0,003 in left ear; =13,535, p=0,001 in right ear). There was a trend to children with an "unobstructed" nasal sound that had a lower clinical severity score when compared with “obstructed” children. Conclusion: It was observed a good intra and substantial inter reliability for nasal auscultation. Nasal auscultation sounds’ classification was related to middle ears’ pressure and compliance.
Resumo:
This paper presents a complete, quadratic programming formulation of the standard thermal unit commitment problem in power generation planning, together with a novel iterative optimisation algorithm for its solution. The algorithm, based on a mixed-integer formulation of the problem, considers piecewise linear approximations of the quadratic fuel cost function that are dynamically updated in an iterative way, converging to the optimum; this avoids the requirement of resorting to quadratic programming, making the solution process much quicker. From extensive computational tests on a broad set of benchmark instances of this problem, the algorithm was found to be flexible and capable of easily incorporating different problem constraints. Indeed, it is able to tackle ramp constraints, which although very important in practice were rarely considered in previous publications. Most importantly, optimal solutions were obtained for several well-known benchmark instances, including instances of practical relevance, that are not yet known to have been solved to optimality. Computational experiments and their results showed that the method proposed is both simple and extremely effective.
Resumo:
This work addresses the problem of traction control in mobile wheeled robots in the particular case of the RoboCup Middle Size League (MSL). The slip control problem is formulated using simple friction models for ISePorto Team robots with a differential wheel configuration. Traction was also characterized experimentally in the MSL scenario for relevant game events. This work proposes a hierarchical traction control architecture which relies in local slip detection and control at each wheel, with relevant information being relayed to a higher level responsible for global robot motion control. A dedicated one axis control embedded hardware subsystem allowing complex local control, high frequency current sensing and odometric information procession was developed. This local axis control board is integrated in a distributed system using CAN bus communications. The slipping observer was implemented in the axis control hardware nodes integrated in the ISePorto robots and was used to control and detect loss of for traction. %and to detect the ball in the kicking device. An external vision system was used to perform a qualitative analysis of the slip detection and observer performance results are presented.
Resumo:
Portugal is a small economy, with an open domestic market that needs competitive exporters to prosper. Trade fairs are an international promotion tool that can be used by firms when considering export development and expansion. This study identifies and evaluates the critical factors that influenced the decision making process of Portuguese SME’s (Small and Medium-Sized Enterprises) managers to participate (or not) in international trade fairs. The results indicate that the firm’s critical decisions factors to select an international trade fair were value for money and the stand (location, typology and size)
Resumo:
Investigação no âmbito do Projeto de Doutoramento(PhD), especialidade de Gestão Global, Estratégia e Desenvolvimento Empresarial (ISCTE-IUL - 2012, classificação de “Aprovado com Muito Bom”).
Resumo:
57Th EOQ Congress, Quality Renaissance - Co-creating a Viable Future"
Resumo:
The main goal of this paper is to analyse the impacts of transformational leadership on organisational commitment. To this effect we developed a case study following a quantitative methodological approach. The research was conducted at the Serralves Foundation (Porto, Portugal) to empirically test the proposed research model and its hypothesis. The empirical results confirm that transformational leadership are not significantly influenced by commitment. As the main limitation of this study we highlight the fact that it does not consider the leaders’ perspective on their subordinates’ behaviour.
Resumo:
Objective The aim of this study was to determine tympanometric values of children who attend Oporto daycare centers and further analyze any relations with host and environmental factors. Methods Cross sectional study in a randomly selected sample of 117 daycare children up-to 3-years old from Oporto. Tympanometric measures were collected. Results Children presented in left ear (LE) a mean peak pressure (PP) of −156.53 daPa and a mean compliance of 0.16 cm3. Right ear (RE) revealed a PP of −145.61 daPa and a compliance of 0.19 cm3. Normal tympanograms (type A) had a lower frequency than abnormal tympanograms (type B and type C). There was a positive association between age and compliance (LE: p = 0.016; RE: p = 0.013) and between the presence of rhinorrhea and PP (LE: p = 0.002; RE: p < 0.05). Abnormal tympanograms were more frequent in Spring (RE: p = 0.009), in younger children (LE: p = 0.03) and in children that had rhinorrhea (LE: p = 0.002; RE: p = 0.044). Healthy children had a mean PP of −125.19 daPa and a mean compliance of 0.21 cm3 in LE and a mean PP of −144.27 daPa and a mean compliance of 0.22 cm3 in RE. Conclusion Tympanometric measures presented in this paper may be applicable to Oporto daycare children up-to 3 years-old. Most of daycare children revealed abnormal tympanograms. Age, rhinorrhea and season influenced children's middle-ear condition.
Resumo:
Trabalho de Projeto apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Tradução e Interpretação Especializadas, sob orientação da Doutora Clara Sarmento
Resumo:
in RoboCup 2007: Robot Soccer World Cup XI
Resumo:
Proceedings of the 10th Mediterranean Conference on Control and Automation - MED2002 Lisbon, Portugal, July 9-12, 2002
Resumo:
The integration of wind power in eletricity generation brings new challenges to unit commitment due to the random nature of wind speed. For this particular optimisation problem, wind uncertainty has been handled in practice by means of conservative stochastic scenario-based optimisation models, or through additional operating reserve settings. However, generation companies may have different attitudes towards operating costs, load curtailment, or waste of wind energy, when considering the risk caused by wind power variability. Therefore, alternative and possibly more adequate approaches should be explored. This work is divided in two main parts. Firstly we survey the main formulations presented in the literature for the integration of wind power in the unit commitment problem (UCP) and present an alternative model for the wind-thermal unit commitment. We make use of the utility theory concepts to develop a multi-criteria stochastic model. The objectives considered are the minimisation of costs, load curtailment and waste of wind energy. Those are represented by individual utility functions and aggregated in a single additive utility function. This last function is adequately linearised leading to a mixed-integer linear program (MILP) model that can be tackled by general-purpose solvers in order to find the most preferred solution. In the second part we discuss the integration of pumped-storage hydro (PSH) units in the UCP with large wind penetration. Those units can provide extra flexibility by using wind energy to pump and store water in the form of potential energy that can be generated after during peak load periods. PSH units are added to the first model, yielding a MILP model with wind-hydro-thermal coordination. Results showed that the proposed methodology is able to reflect the risk profiles of decision makers for both models. By including PSH units, the results are significantly improved.