5 resultados para mass transfer models

em Instituto Politécnico do Porto, Portugal


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to obtain, for Newtonian and non-Newtonian fluids, heat transfer coefficients, at constant wall temperature as boundary condition, in fully developed laminar flow inside a helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w) and the non-Newtonian fluids aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations 0.1%, 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations 0.1% and 0.2% (w/w). According to the rheological study performed, the polymer solutions had shear thinning behavior and different values of elasticity. The helical coil used has internal diameter, curvature ratio, length and pitch, respectively: 0.004575 m, 0.0263, 5.0 m and 11.34 mm. The Nusselt numbers for the CMC solutions are, on average, slightly higher than those for Newtonian fluids, for identical Prandtl and generalized Dean numbers. As outcome, the viscous component of the shear thinning polymer tends to potentiate the mixing effect of the Dean cells. The Nusselt numbers of the XG solutions are significant lower than those of the Newtonian solutions, for identical Prandtl and generalized Dean numbers. Therefore, the elastic component of the polymer tends to diminish the mixing effect of the Dean cells. A global correlation, for Nusselt number as a function of Péclet, generalized Dean and Weissenberg numbers for all Newtonian and non-Newtonian solutions studied, is presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for the column design for any particular type of packing and contaminant avoiding the necessity of a pre-defined diameter used in the classical approach. It also renders unnecessary the employment of the graphical Eckert generalized correlation for pressure drop estimates. The hydraulic features are previously chosen as a project criterion and only afterwards the mass transfer phenomena are incorporated, in opposition to conventional approach. The design procedure was translated into a convenient algorithm using C++ as programming language. A column was built in order to test the models used either in the design or in the simulation of the column performance. The experiments were fulfilled using a solution of chloroform in distilled water. Another model was built to simulate the operational performance of the column, both in steady state and in transient conditions. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting system of ODE can be solved, allowing for the calculation of the concentration profile in both phases inside the column. In transient state the system of PDE was numerically solved by finite differences, after a previous linearization.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

STRIPPING is a software application developed for the automatic design of a randomly packing column where the transfer of volatile organic compounds (VOCs) from water to air can be performed and to simulate it’s behaviour in a steady-state. This software completely purges any need of experimental work for the selection of diameter of the column, and allows a choice, a priori, of the most convenient hydraulic regime for this type of operation. It also allows the operator to choose the model used for the calculation of some parameters, namely between the Eckert/Robbins model and the Billet model for estimating the pressure drop of the gaseous phase, and between the Billet and Onda/Djebbar’s models for the mass transfer. Illustrations of the graphical interface offered are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for column design for any type of packing and contaminant which avoids the necessity of an arbitrary chosen diameter. It also avoids the employment of the usual graphical Eckert correlations for pressure drop. The hydraulic features are previously chosen as a project criterion. The design procedure was translated into a convenient algorithm in C++ language. A column was built in order to test the design, the theoretical steady-state and dynamic behaviour. The experiments were conducted using a solution of chloroform in distilled water. The results allowed for a correction in the theoretical global mass transfer coefficient previously estimated by the Onda correlations, which depend on several parameters that are not easy to control in experiments. For best describe the column behaviour in stationary and dynamic conditions, an original mathematical model was developed. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting ODE can be solved by analytical methods, and in dynamic state the discretization of the PDE by finite differences allows for the overcoming of this difficulty. To estimate the contaminant concentrations in both phases in the column, a numerical algorithm was used. The high number of resulting algebraic equations and the impossibility of generating a recursive procedure did not allow the construction of a generalized programme. But an iterative procedure developed in an electronic worksheet allowed for the simulation. The solution is stable only for similar discretizations values. If different values for time/space discretization parameters are used, the solution easily becomes unstable. The system dynamic behaviour was simulated for the common liquid phase perturbations: step, impulse, rectangular pulse and sinusoidal. The final results do not configure strange or non-predictable behaviours.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Em Portugal existem muitos espaços comerciais e industriais em que as necessidades térmicas de arrefecimento são muito superiores às necessidades de aquecimento devido aos ganhos internos que advêm da existência de equipamentos e da iluminação dos edifícios, assim como, da presença das pessoas. A instalação de sistemas convencionais de ar condicionado para espaços comerciais e industriais de grande dimensão está geralmente associada ao transporte de grandes caudais de ar, e consequentemente, a elevados consumos de energia primária, e também, elevados custos de investimento, de manutenção e de operação. O arrefecedor evaporativo é uma solução de climatização com elevada eficiência energética, cujo princípio de funcionamento promove a redução do consumo de energia primária nos edifícios. A metodologia utilizada baseou-se na criação de uma ferramenta informática de simulação do funcionamento de um protótipo de um arrefecedor evaporativo. Foi efetuada a modelação matemática das variáveis dinâmicas envolvidas, dos processos de transferência de calor e de massa, assim como dos balanços de energia que ocorrem no arrefecedor evaporativo. A ferramenta informática desenvolvida permite o dimensionamento do protótipo do arrefecedor evaporativo, sendo determinadas as caraterísticas técnicas (potência térmica, caudal, eficiência energética, consumo energético e consumo e água) de acordo com o tipo de edifício e com as condições climatéricas do ar exterior. Foram selecionados três dimensionamentos de arrefecedores evaporativos, representativos de condições reais de uma gama baixa, média e elevada de caudais de ar. Os resultados obtidos nas simulações mostram que a potência de arrefecimento (5,6 kW, 16,0 kW e 32,8 kW) e o consumo de água (8 l/h, 23,9 l/h e 48,96 l/h) aumentam com o caudal de ar do arrefecedor, 5.000 m3/h, 15.000 m3/h e 30.000 m3/h, respetivamente. A eficácia de permuta destes arrefecedores evaporativos, foi de 69%, 66% e 67%, respetivamente. Verificou-se que a alteração de zona climática de V1 para V2 implicou um aumento de 39% na potência de arrefecimento e de 20% no consumo de água, e que, a alteração de zona climática de V2 para V3 implicou um aumento de 39% na potência de arrefecimento e de 39% no consumo de água. O arrefecedor evaporativo apresenta valores de consumo de energia elétrica entre 40% a 80% inferiores aos dos sistemas de arrefecimento convencionais, sendo este efeito mais intenso quando a zona climática de verão se torna mais severa.