20 resultados para loss rate
em Instituto Politécnico do Porto, Portugal
Resumo:
We consider reliable communications in Body Area Networks (BAN), where a set of nodes placed on human body are connected using wireless links. In order to keep the Specific Absorption Rate (SAR) as low as possible for health safety reasons, these networks operate in low transmit power regime, which however, is known to be error prone. It has been observed that the fluctuations of the Received Signal Strength (RSS) at the nodes of a BAN on a moving person show certain regularities and that the magnitude of these fluctuations are significant (5 - 20 dB). In this paper, we present BANMAC, a MAC protocol that monitors and predicts the channel fluctuations and schedules transmissions opportunistically when the RSS is likely to be higher. The MAC protocol is capable of providing differentiated service and resolves co-channel interference in the event of multiple co-located BANs in a vicinity. We report the design and implementation details of BANMAC integrated with the IEEE 802.15.4 protocol stack. We present experimental data which show that the packet loss rate (PLR) of BANMAC is significantly lower as compared to that of the IEEE 802.15.4 MAC. For comparable PLR, the power consumption of BANMAC is also significantly lower than that of the IEEE 802.15.4. For co-located networks, the convergence time to find a conflict-free channel allocation was approximately 1 s for the centralized coordination mechanism and was approximately 4 s for the distributed coordination mechanism.
Resumo:
Temporal isolation is an increasingly relevant con- cern in particular for ARINC-351 and virtualisation- based systems. Traditional approaches like the rate- based scheduling framework RBED do not take into account the impact of preemptions in terms of loss of working set in the acceleration hardware (e.g. caches). While some improvements have been suggested in the literature, they are overly heavy in the presence of small high-priority tasks such as interrupt service routines. Within this paper we propose an approach enabling adaptive assessment of this preemption delay in a tem- poral isolation framework with special consideration of capabilities and limitations of the approach.
Resumo:
Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.
Resumo:
Sendo, o exercício físico uma parte importante na Reabilitação de pacientes com patologia cardíaca, o presente estudo tem por Objectivo: verificar se um programa de exercícios aeróbios, mesmo quando associadas a patologias crónicas poderão ter efeito nas variáveis da capacidade funcional, ansiedade e depressão e qualidade de vida. Tipo de estudo: série de estudos de caso prospectivo. Métodos: O programa de exercício realizou-se em 8 semanas tendo cada um dos doentes cardíacos sido avaliados no início do plano e no fim das 8 semanas sobre os seguintes aspectos: a composição corporal (massa magra, massa gorda, Taxa metabólica basal e água), o teste dos 6 minutos de marcha, em termos de ansiedade /depressão e percepção do estados de saúde. Resultados: Em relação à composição corporal, destacase a perda de peso no caso clínico 4 com uma variação de -4.54%; aumento de massa magra de 46.6% e uma diminuição de massa gorda de -41 .1% no caso clínico 2 e um aumento de 4,78% da taxa de metabolismo basal no caso clínico 1 . Na capacidade funcional de exercício houve uma variação média positiva de 16,8% na distância percorrida; verifica-se também um aumento gradual de tempo de exercício ao longo das 8 semanas de tratamento. Por último, uma variação média negativa nos níveis de ansiedade de -28,5% e depressão de -40%; um aumento de 30% na percepção subjectiva do estado de saúde nos 4 casos clínicos deste estudo. Conclusão: O programa de exercícios teve efeitos positivos nos 4 casos clínicos estudados. No entanto, pelas características individuais de cada caso, os seus efeitos tiveram impacto diferente em cada caso, devendo por isso, ser prescrito exercício de forma individualizada.
Resumo:
Mestrado em Engenharia Química. Ramo optimização energética na indústria química.
Resumo:
Como o sector cerâmico é um consumidor intensivo de energia, este trabalho teve como objectivo principal a elaboração de um plano de optimização do desempenho energético da olaria número três da Fábrica Cerâmica de Valadares. Para o efeito, efectuou-se o levantamento energético desta fracção autónoma. O valor total obtido para os ganhos térmicos foi de 8,7x107 kJ/dia, sendo 82% desta energia obtida na combustão do gás natural. Por outro lado, as perdas energéticas rondam os 8,2x107 kJ/dia, sendo o ar de exaustão e a envolvente os principais responsáveis, com um peso de 42 % e 38%, respectivamente. Tendo em conta estes valores, estudaram-se várias medidas de isolamento da cobertura, pavimento, paredes e saída de ar através de fendas do edifício. No caso do isolamento da cobertura sugeriu-se a substituição das telhas de fibrocimento e do isolamento actualmente existentes por painéis sandwich de cobertura. Esta acção permite uma poupança de 64.796€/ano, com um investimento de 57.029€ e o seu período de retorno de 0,9 anos. O Valor Actualizado Líquido (VAL) no 5º ano foi de 184.069€, com uma Taxa Interna de Rentabilidade (TIR) de 92%. Para isolar o pavimento, sugeriu-se a utilização de placas de poliuretano expandido (PU) de 20mm de espessura. Assim, consegue-se uma poupança de 7.442 €/ano, com um investimento de 21.708€, e um tempo de retorno 2,9 anos. No final do 5º ano de vida útil do projecto, o VAL é de 4.070€ e a TIR 7%. Relativamente ao isolamento das paredes e pilares, sugeriu-se a utilização de placas de PU (30mm), recobertas com chapa de ferro galvanizado. O tempo de retorno do investimento é de 1,5 anos, uma vez que, o investimento é de 13.670€ e a poupança anual será de 9.183€. Esta solução apresenta no último ano um VAL de 12.835€ e uma TIR de 22%. No isolamento das fendas do edifício, sugeriu-se a redução de 20% da sua área livre. Esta medida de optimização implica um investimento de 8.000€, revelando-se suficientemente eficaz, pois apresenta um tempo de retorno de 0,67 anos. O VAL e a TIR da solução no último ano de vida útil do projecto de investimento são de 36.835€ e 35%, respectivamente. Por fim, sugeriu-se ainda a instalação de um sistema de controlo que visa o aproveitamento de ar quente proveniente do forno, instalado no piso inferior à olaria, para pré-aquecer o ar alimentado aos geradores de calor. Esta medida implicaria um investimento de 4.000€, com um tempo de retorno de 2,4 anos e uma poupança anual é de 1.686€. O investimento é aconselhável, já que, no 5º ano, o VAL é de 1.956€ e a TIR é de 17%.
Resumo:
Airflow rate is one of the most important parameters for the soil vapor extraction of contaminated sites, due to its direct influence on the mass transfer occurring during the remediation process. This work reports the study of airflow rate influence on soil vapor extractions, performed in sandy soils contaminated with benzene, toluene, ethylbenzene, xylene, trichloroethylene and perchloroethylene. The objectives were: (i) to analyze the influence of airflow rate on the process; (ii) to develop a methodology to predict the remediation time and the remediation efficiency; and (iii) to select the most efficient airflow rate. For dry sandy soils with negligible contents of clay and natural organic matter, containing the contaminants previously cited, it was concluded that: (i) if equilibrium between the pollutants and the different phases present in the soil matrix was reached and if slow diffusion effects did not occur, higher airflow rates exhibited the fastest remediations, (ii) it was possible to predict the remediation time and the efficiency of remediation with errors below 14%; and (iii) the most efficient remediation were reached with airflow rates below 1.2 cm3 s 1 standard temperature and pressure conditions.
Resumo:
Abstract This work reports the analysis of the efficiency and time of soil remediation using vapour extraction as well as provides comparison of results using both, prepared and real soils. The main objectives were: (i) to analyse the efficiency and time of remediation according to the water and natural organic matter content of the soil; and (ii) to assess if a previous study, performed using prepared soils, could help to preview the process viability in real conditions. For sandy soils with negligible clay content, artificially contaminated with cyclohexane before vapour extraction, it was concluded that (i) the increase of soil water content and mainly of natural organic matter content influenced negatively the remediation process, making it less efficient, more time consuming, and consequently more expensive; and (ii) a previous study using prepared soils of similar characteristics has proven helpful for previewing the process viability in real conditions.
The utilization bound of non-preemptive rate-monotonic scheduling in controller area networks is 25%
Resumo:
Consider a distributed computer system comprising many computer nodes, each interconnected with a controller area network (CAN) bus. We prove that if priorities to message streams are assigned using rate-monotonic (RM) and if the requested capacity of the CAN bus does not exceed 25% then all deadlines are met.
Resumo:
An experimental study to evaluate the power dissipation of gears was performed. Three low-loss gear models were manufactured using standard 20° pressure angle tools. Austempered ductile iron (ADI) and 20MnCr5 carburized steel gears were tested in an FZG gear test machine using mineral, ester and polyalphaolephine (PAO)-based oils. The results compare power dissipation, the influence of different tooth flank geometries, materials and lubricants. This work concludes that conventional power-transmission gears can be replaced by these improved and more efficient low–loss models, which can be produced using common tools and that steel gears can be successfully replaced by austempered ductile iron gears.
Resumo:
Low-loss power transmission gears operate at lower temperature than conventional ones because their teeth geometry is optimized to reduce friction. The main objective of this work is to compare the operating stabilization temperature and efficiency of low-loss austempered ductile iron (ADI) and carburized steel gears. Three different low-loss tooth geometries were adopted (types 311, 411 and 611, all produced using standard 20° pressure angle tools) and corresponding steel and ADI gears were tested in a FZG machine. The results obtained showed that low-loss geometries had a significant influence on power loss, gears 611 generating lower power loss than gears 311. At low speeds (500 and 1000 rpm) and high torque ADI gears generated lower power loss than steel gears. However, at high speed and high torque (high input power and high stabilization temperature) steel gears had better efficiency.
Resumo:
The minimization of the power loss and the use of the biodegradable greases have attracting considerable attention. To compare the energetic performance of biodegradable lubricant greases, power loss tests were performed on a modified four-ball machine. A correlation between the grease formulation and rheology was established with its energetic performance
Resumo:
A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.
Resumo:
Introdução: Os exercícios de fortalecimento dos músculos do pavimento pélvico (EFMPP) são considerados a primeira intervenção no tratamento da incontinência urinária de esforço (IUE), porém os EFMPP são distintos, não existindo evidência sobre os parâmetros de treino. Objetivo: Identificar o protocolo e/ ou os parâmetros de treino dos músculos do pavimento pélvico (MPP) mais eficaz no tratamento da IUE feminina. Método: A pesquisa bibliográfica foi realizada entre janeiro de 1992 a março de 2014 nas bases de dados PubMed, Cochrane Library, PEDro, web of Science e LILACS. Os artigos incluídos eram de língua inglesa, estudos experimentais, no qual comparavam EFMPP com o tratamento placebo, usual ou sem tratamento, com idade compreendida entre os 18 e os 65 anos e diagnóstico de IUE. Os critérios de exclusão abrangeram o diagnóstico de IUE desencadeada por fatores externos ao trato urinário inferior, grávidas, puérperas, prolapso ≥ 2 e outros tipos de IU. A avaliação da qualidade metodológica for realizada através da escala PEDro. Resultados: Sete artigos de elevada qualidade metodológica foram incluídos na presente revisão. A amostra foi constituída por 331 mulheres, com idade média de 44,4 anos, duração média das perdas urinárias de 64 meses e a gravidade da IUE variou entre ligeira a severa. Os programas de EFMPP eram distintos em relação aos parâmetros de treino dos MPP, sendo que alguns estudos incluíram o treino abdominal, supervisão e técnicas adjuvantes. A taxa de curada da quantidade de perda urinária variou entre 28,6 a 80%, enquanto a força dos MPP variou de 15,6% a 161,7%. Conclusão: Na presente revisão sistemática, os EFMPP combinados com palpação digital, biofeedback e cones vaginais parecem ser mais eficazes na redução da quantidade de perda urinária, comparado com os EFMPP isolados ou sem tratamento. Esta revisão permitiu igualmente identificar as 12 semanas de duração da intervenção, 10 repetições por série e diferentes posições, sendo os parâmetros de treino mais consistentes na redução dos sintomas.
Resumo:
Introdução: Os exercícios de fortalecimento dos músculos do pavimento pélvico (EFMPP) são considerados a primeira intervenção no tratamento da incontinência urinária de esforço (IUE), porém os EFMPP são distintos, não existindo evidência sobre os parâmetros de treino. Objetivo: Identificar o protocolo e/ ou os parâmetros de treino dos músculos do pavimento pélvico (MPP) mais eficaz no tratamento da IUE feminina. Método: A pesquisa bibliográfica foi realizada entre janeiro de 1992 a março de 2014 nas bases de dados PubMed, Cochrane Library, PEDro, web of Science e LILACS. Os artigos incluídos eram de língua inglesa, estudos experimentais, no qual comparavam EFMPP com o tratamento placebo, usual ou sem tratamento, com idade compreendida entre os 18 e os 65 anos e diagnóstico de IUE. Os critérios de exclusão abrangeram o diagnóstico de IUE desencadeada por fatores externos ao trato urinário inferior, grávidas, puérperas, prolapso ≥ 2 e outros tipos de IU. A avaliação da qualidade metodológica for realizada através da escala PEDro. Resultados: Sete artigos de elevada qualidade metodológica foram incluídos na presente revisão. A amostra foi constituída por 331 mulheres, com idade média de 44,4 anos, duração média das perdas urinárias de 64 meses e a gravidade da IUE variou entre ligeira a severa. Os programas de EFMPP eram distintos em relação aos parâmetros de treino dos MPP, sendo que alguns estudos incluíram o treino abdominal, supervisão e técnicas adjuvantes. A taxa de curada da quantidade de perda urinária variou entre 28,6 a 80%, enquanto a força dos MPP variou de 15,6% a 161,7%. Conclusão: Na presente revisão sistemática, os EFMPP combinados com palpação digital, biofeedback e cones vaginais parecem ser mais eficazes na redução da quantidade de perda urinária, comparado com os EFMPP isolados ou sem tratamento. Esta revisão permitiu igualmente identificar as 12 semanas de duração da intervenção, 10 repetições por série e diferentes posições, sendo os parâmetros de treino mais consistentes na redução dos sintomas.