13 resultados para liquid sheets
em Instituto Politécnico do Porto, Portugal
Resumo:
Titanium films have been deposited on stainless steel metal sheets using dc magnetron sputtering technique at different substrate temperatures. The structure of the titanium films strongly depend on the substrate temperature. The titanium film deposited at the substrate temperature lower than 300 ◦C has a loose flat sheet grains structure and the titanium film prepared at the substrate temperature higher than 500 ◦C has a dense nubby grains structure. The DSSC assembled using stainless steel sheet coated with titanium film deposited at high substrate temperature has a low charge transfer resistance in the TiO2/Ti interface and results in a high conversion efficiency. The DSSC assembled using stainless steel sheet coated with titanium film deposited at temperature higher than 500 ◦C has higher conversion efficiency than that assembled using titanium metal sheet as the substrate. The maximum conversion efficiency, 2.26% is obtained for DSSC assembled using stainless steel sheet coated with titanium film deposited at 700 ◦C substrate temperature, which is about 70% of the conversion efficiency of the FTO reference cell used in this study.
Resumo:
A methodology based on microwave-assisted extraction (MAE) and LC with fluorescence detection (FLD) was investigated for the efficient determination of 15 polycyclic aromatic hydrocarbons (PAHs) regarded as priority pollutants by the US Environmental Protection Agency and dibenzo(a,l)pyrene in atmospheric particulate samples. PAHs were successfully extracted from real outdoor particulate matter (PM) samples with recoveries ranging from 81.4±8.8 to 112.0±1.1%, for all the compounds except for naphthalene (62.3±18.0%) and anthracene (67.3±5.7%), under the optimum MAE conditions (30.0 mL of ACN for 20 min at 110ºC). No clean-up steps were necessary prior to LC analysis. LOQs ranging from 0.0054 ng/m3 for benzo( a)anthracene to 0.089 ng/m3 for naphthalene were reached. The validated MAE methodology was applied to the determination of PAHs from a set of real world PM samples collected in Oporto (north of Portugal). The sum of particulate-bound PAHs in outdoor PM ranged from 2.5 and 28 ng/m3.
Resumo:
A multiresidue approach using microwave-assisted extraction and liquid chromatography with photodiode array detection was investigated for the determination of butylate, carbaryl, carbofuran, chlorpropham, ethiofencarb, linuron,metobromuron, and monolinuron in soils. The critical parameters of the developed methodology were studied. Method validation was performed by analyzing freshly and aged spiked soil samples. The recoveries and relative standard deviations reached using the optimized conditions were between 77.0 ± 0.46% and 120 ± 2.9% except for ethiofencarb (46.4 ± 4.4% to 105 ± 1.6%) and butylate (22.1 ± 7.6% to 49.2 ± 11%). Soil samples from five locations of Portugal were analysed.
Resumo:
An analytical multiresidue method for the simultaneous determination of seven pesticides in fresh vegetable samples, namely, courgette (Cucurbita pepo), cucumber (Cucumis sativus), lettuce (Lactuca sativa, Romaine and Iceberg varieties) and peppers (Capsicum sp.) is described. The procedure, based on microwave-assisted extraction (MAE) and analysis by liquid chromatography– photodiode array (LC–PDA) detection was applied to four carbamates (carbofuran, carbaryl, chlorpropham and EPTC) and three urea pesticides (monolinuron, metobromuron and linuron). Extraction solvent and the addition of anhydrous sodium sulphate to fresh vegetable homogenate before MAE were the parameters optimised for each commodity. Recovery studies were performed using spiked samples in the range 250–403 µgkg- 1 in each pesticide. The pesticide residues were extracted using 20mL acetonitrile at 60 ºC, for 10 min. Acceptable recoveries and RSDs were attained (overall average recovery of 77.2% and RSDs are lower than 11%). Detection limits ranged between 5.8 µgkg- 1 for carbaryl to 12.3 µgkg- 1 for carbofuran. The analytical protocol was applied for quality control of 41 fresh vegetable samples bought in Oporto Metropolitan Area (North Portugal). None of the samples contained any detectable amounts of the studied compounds.
Resumo:
An analytical method, based on microwave-assisted extraction and liquid chromatography with diode array detection, for the determination of six carbamate and three urea pesticides in fresh and processed tomato samples is described. Significant parameters affecting extraction efficiency were optimized. Under optimum microwave-assisted extraction conditions (20mL acetonitrile, for 10 minutes, at 60º C), pesticides were extracted with recoveries ranging from 57.6 to 102% (RSDs<7%). Quantification limits between 6.5 and 39.6 µg=kg were obtained. A total number of 28 different fresh tomato samples and 6 processed tomato products were analysed. Confirmation of suspicious samples was performed by LC-MS.
Resumo:
The industrial manufacturing of metallic objects results in a high level of foundry waste sands that may contain toxic compounds such as formaldehyde. The formaldehyde content of foundry waste sands was evaluated by liquid chromatography. Samples were collected during various steps of the industrial processes. Results showed that the phenolic alkaline process generated waste sands with higher formaldehyde content than the furanic process; the highest value was 7.6×10-3% (w/w). In this work, formaldehyde content decreased with time in all of the samples studied, revealing that most formaldehyde was released to the occupational environment.
Resumo:
Formaldehyde is a toxic component that is present in foundry resins. Its quantification is important to the characterisation of the resin (kind and degradation) as well as for the evaluation of free contaminants present in wastes generated by the foundry industry. The complexity of the matrices considered suggests the need for separative techniques. The method developed for the identification and quantification of formaldehyde in foundry resins is based on the determination of free carbonyl compounds by derivatization with 2,4-dinitrophenylhydrazine (DNPH), being adapted to the considered matrices using liquid chromatography (LC) with UV detection. Formaldehyde determinations in several foundry resins gave precise results. Mean recovery and R.S.D. were, respectively, >95 and 5%. Analyses by the hydroxylamine reference method gave comparable results. Results showed that hydroxylamine reference method is applicable just for a specific kind of resin, while the developed method has good performance for all studied resins.
Resumo:
This paper presents a fractional calculus perspective in the study of signals captured during the movement of a mechanical manipulator carrying a liquid container. In order to study the signals an experimental setup is implemented. The system acquires data from the sensors, in real time, and, in a second phase, processes them through an analysis package. The analysis package runs off-line and handles the recorded data. The results show that the Fourier spectrum of several signals presents a fractional behavior. The experimental study provides useful information that can assist in the design of a control system and the trajectory planning to be used in reducing or eliminating the effect of vibrations.
Resumo:
The interest for environmental fate assessment of chiral pharmaceuticals is increasing and enantioselective analytical methods are mandatory. This study presents an enantioselective analytical method for the quantification of seven pairs of enantiomers of pharmaceuticals and a pair of a metabolite. The selected chiral pharmaceuticals belong to three different therapeutic classes, namely selective serotonin reuptake inhibitors (venlafaxine, fluoxetine and its metabolite norfluoxetine), beta-blockers (alprenolol, bisoprolol, metoprolol, propranolol) and a beta2-adrenergic agonist (salbutamol). The analytical method was based on solid phase extraction followed by liquid chromatography tandem mass spectrometry with a triple quadrupole analyser. Briefly, Oasis® MCX cartridges were used to preconcentrate 250 mL of water samples and the reconstituted extracts were analysed with a Chirobiotic™ V under reversed mode. The effluent of a laboratory-scale aerobic granular sludge sequencing batch reactor (AGS-SBR) was used to validate the method. Linearity (r2 > 0.99), selectivity and sensitivity were achieved in the range of 20–400 ng L−1 for all enantiomers, except for norfluoxetine enantiomers which range covered 30–400 ng L−1. The method detection limits were between 0.65 and 11.5 ng L−1 and the method quantification limits were between 1.98 and 19.7 ng L−1. The identity of all enantiomers was confirmed using two MS/MS transitions and its ion ratios, according to European Commission Decision 2002/657/EC. This method was successfully applied to evaluate effluents of wastewater treatment plants (WWTP) in Portugal. Venlafaxine and fluoxetine were quantified as non-racemic mixtures (enantiomeric fraction ≠ 0.5). The enantioselective validated method was able to monitor chiral pharmaceuticals in WWTP effluents and has potential to assess the enantioselective biodegradation in bioreactors. Further application in environmental matrices as surface and estuarine waters can be exploited.
Resumo:
A presente dissertação foi realizada em colaboração com o grupo empresarial Monteiro, Ribas, tendo como principal objectivo a realização de uma auditoria à gestão dos resíduos industriais produzidos pelas suas fábricas localizadas na Estrada da Circunvalação, no Porto. Para cumprir este objectivo, inicialmente foi efectuado um levantamento das obrigações legais relativas aos resíduos e foram procuradas práticas aconselhadas para a gestão interna. Para cada uma das fábricas, verificaram-se, quais os resíduos produzidos e analisaram-se os seus percursos, considerando as suas origens, os locais e modos de acondicionamento na origem, os modos de transporte interno, os locais e modos de armazenagem preliminar, e ainda, as quantidades produzidas, os transportadores, os operadores finais e as operações finais de gestão, sendo que estas quatro últimas informações são relativas ao ano 2013. De seguida procedeu-se à realização da auditoria nas diferentes unidades, verificando o cumprimento dos requisitos legais e das boas práticas em matéria de gestão de resíduos. As principais não conformidades detectadas, comuns às várias unidades fabris foram a inexistência de local/recipiente definido para acondicionamento de alguns resíduos, a falta ou insuficiente identificação de recipientes/zonas de acondicionamento, a inexistência de bacias de retenção para resíduos líquidos perigosos, o facto de no transporte interno apenas os resíduos perigosos serem cobertos e, os resíduos líquidos perigosos não serem transportados sobre bacias de retenção móveis nem com o material necessário para absorver derrames. Para cada resíduo e para cada unidade industrial foram propostas medidas correctivas e/ou de melhoria, quando aplicável. Relativamente à armazenagem preliminar, a principal inconformidade detectada foi o facto de todos os parques (quatro) possuírem resíduos perigosos no momento das auditorias, o que não é adequado. Foram propostas medidas correctivas e/ou de melhoria para cada parque. Como proposta global, tendo em conta factores económicos e de segurança, sugeriu-se que apenas o parque de resíduos perigosos possa armazenar este tipo de resíduos, pelo que os procedimentos de transporte interno devem ser melhorados, fazendo com que estes resíduos sejam transportados directamente para o parque de resíduos perigosos. Desta forma dois dos parques devem sofrer algumas remodelações, nomeadamente serem cobertos e fechados, ainda que não totalmente, e o parque de resíduos perigosos deve ser fechado, mantendo aberturas para ventilação, deve ser equipado com kit´s de contenção de derrames, fichas de segurança, procedimentos a realizar em caso de emergência, e ainda, devido ao facto do sistema de contenção de derrames ser pequeno face ao total de armazenamento, aconselha-se o uso de bacias de retenção para alguns dos recipientes de resíduos líquidos perigosos. Ao longo deste processo e em consequência da realização da auditoria, algumas situações consideradas não conformes foram sendo corrigidas. Também foram preparadas instruções de trabalho adequadas que serão posteriormente disponibilizadas. Foi ainda elaborada uma metodologia de avaliação de processos como base de trabalho para redução dos resíduos gerados. A etapa escolhida para a aplicação da mesma foi uma etapa auxiliar do processo produtivo da Monteiro, Ribas - Revestimentos, S.A - a limpeza de cubas com solventes, por forma a tentar minimizar os resíduos de solventes produzidos nesta operação. Uma vez que a fábrica já realiza a operação tendo em consideração medidas de prevenção e reutilização, a reciclagem é neste momento a única forma de tentar minimizar os resíduos de solventes. Foram então estudadas duas opções, nomeadamente a aquisição de um equipamento de regeneração de solventes e a contratação de uma operadora que proceda à regeneração dos resíduos de solventes e faça o retorno do solvente regenerado. A primeira opção poderá permitir uma redução de cerca de 95% na produção de resíduos de solventes e na aquisição de solvente puro, estimando-se uma poupança anual de cerca de **** €, com um período de recuperação do capital de cerca de 16 meses e a segunda pode conduzir a uma redução significativa na aquisição de solvente puro, cerca de 65%, e a uma poupança anual de cerca de **** €.
Resumo:
The Basel Committee on Banking Supervision (BCBS) introduced new regulations for banking supervision in December 2010, better known as Basel III recommendations that aimed at guaranteeing the solidity of banks worldwide and the mitigation of new banking crises risks. The European Union transposed these directives through the Credit Review Directives IV (CRD IV). Portugal adopted CRD IV by a new decree-law no. 157/2014, on 24 th October 2014, enforced from 24 th November 2014. While individual banks have been given the option of using the internal ratings based method, this study analyses the compliance levels of all Portuguese banking institutions using the standard method, also prescribed by BCBS. Our results show that out of thirteen banks on 31-12-2013 only five banks were in a comfortable position and the remaining eight could not reach the minimum requirements set up by BCBS for 1-1-2014.
Resumo:
Dissertação de Mestrado Apresentada ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação do Doutor Mário Joel Matos Veiga de Oliveira Queirós.
Resumo:
A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.