8 resultados para levels of fusion

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last years, a rising trend of pollen allergies in urban areas has been attributed to atmospheric pollution. In this work, we investigated the effects of SO2 and NO2 on the protein content, allergenicity, and germination rate of Acer negundo pollen. A novel environmental chamber was assembled to exposure pollen samples with SO2 or NO2 at two different levels: just below and two times the atmospheric hour-limit value acceptable for human health protection in Europe. Results showed that protein content was lower in SO2- exposed pollen samples and slightly higher in NO2-exposed pollen compared to the control sample. No different polypeptide profiles were revealed by SDSPAGE between exposed and nonexposed pollen, but the immunodetection assays indicated higher IgE recognition by all sera of sensitized patients to Acer negundo pollen extracts in all exposed samples in comparison to the nonexposed samples. A decrease in the germination rate of exposed in contrast to nonexposed pollen was verified, which was more pronounced for NO2-exposed samples. Our results indicated that in urban areas, concentrations of SO2 and NO2 below the limits established for human protection can indirectly aggravate pollen allergy on predisposed individuals and affect plant reproduction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gamma radiations measurements were carried out in the vicinity of a coal-fired power plant located in the southwest coastline of Portugal. Two different gamma detectors were used to assess the environmental radiation within a circular area of 20 km centred in the coal plant: a scintillometer (SPP2 NF, Saphymo) and a high purity germanium detector (HPGe, Canberra). Fifty urban and suburban measurements locations were established within the defined area and two measurements campaigns were carried out. The results of the total gamma radiation ranged from 20.83 to 98.33 counts per second (c.p.s.) for both measurement campaigns and outdoor doses rates ranged from 77.65 to 366.51 Gy/h. Natural emitting nuclides from the U-238 and Th-232 decay series were identified as well as the natural emitting nuclide K-40. The radionuclide concentration from the uranium and thorium series determined by gamma spectrometry ranged from 0.93 to 73.68 Bq/kg, while for K-40 the concentration ranged from 84.14 to 904.38 Bq/kg. The obtained results were used primarily to define the variability in measured environmental radiation and to determine the coal plant’s influence in the measured radiation levels. The highest values were measured at two locations near the power plant and at locations between the distance of 6 and 20 km away from the stacks, mainly in the prevailing wind direction. The results showed an increase or at least an influence from the coal-fired plant operations, both qualitatively and quantitatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering vehicular transport as one of the most health‐relevant emission sources of urban air, and with aim to further understand its negative impact on human health, the objective of this work was to study its influence on levels of particulate‐bound PAHs and to evaluate associated health risks. The 16 PAHs considered by USEPA as priority pollutants, and dibenzo[a, l]pyrene associated with fine (PM2.5) and coarse (PM2.5–10) particles were determined. The samples were collected at one urban site, as well as at a reference place for comparison. The results showed that the air of the urban site was more seriously polluted than at the reference one, with total concentrations of 17 PAHs being 2240% and 640% higher for PM2.5 and PM2.5–10, respectively; vehicular traffic was the major emission source at the urban site. PAHs were predominantly associated with PM2.5 (83% to 94% of ΣPAHs at urban and reference site, respectively) with 5 rings PAHs being the most abundant groups of compounds at both sites. The risks associated with exposure to particulate PAHs were evaluated using the TEF approach. The estimated value of lifetime lung cancer risks exceeded the health‐based guideline levels, thus demonstrating that exposure to PM2.5‐bound PAHs at levels found at urban site might cause potential health risks. Furthermore, the results showed that evaluation of benzo[a] pyrene (regarded as a marker of the genotoxic and carcinogenic PAHs) alone would probably underestimate the carcinogenic potential of the studied PAH mixtures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Every year European citizens become victims of devastating fires, which are especially disastrous for Southern European countries. Apart from the numerous health and economic consequences, fires generate hazardous pollutants that are introduced into the environment, thus representing serious risks for public health. In that regard, particulate matter (PM) is of amajor concern. Thus, the objectives of thisworkwere to characterize the trend of forest fire occurrences and burnt area during the period of 2005 and 2010 and to study the influence of forest fires on levels of particulatematter PM10 and PM2.5. In 2010, 22,026 forest fires occurred in Portugal. The northern region was the most affected by forest fires, with 27% of occurrences in Oporto district. The annual means of PM10 and PM2.5 concentrations at two urban background sites were 25±14 μg m−3 and 8.2±4.9 μg m−3, and 17±13 μg m−3 and 7.3±5.9 μg m−3, respectively. At both sites the highest levels of PMfractionswere observed during July and August of 2010, corresponding to the periods when majority (66%) of forest fires occurred. Furthermore, PM10 daily limit at the two sites was exceeded during 20 and 5 days, respectively; 56%, and respectively 60% of those exceedances occurred during the forest fire season. Considering that the risks of forest fire ignition and severity are enhanced with elevated temperatures, the climate change might increase the environmental impacts of forest fires.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng m−3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng m−3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68–200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3–5-year-old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82x104 and 1.32x104 particles/cm3 at US1 an US2, respectively) than at the rural one (1.15x104 particles/cm3). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17x104, 3.28x104, and 4.09x104 particles/cm3 at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31x103, 11.3x103, and 7.14x103 particles/cm3 at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54–0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3–5-year-old children were exposed to 4–6 times higher UFP doses than adults with similar daily schedules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Erasmus Mundus Masters (EMM) are programs with a strong component of interculturality. Our study aimed at understanding the level of cultural intelligence (CQ) of EMM students and alumni, as well as some of the characteristics associated with higher levels of CQ. The study included 626 EMM students and alumni from 109 different countries that encompasses 6 continents. Ang and Van Dyne’s (2006) cultural intelligence scale was used; closed and open ended questions were used to describe the sample’s sociodemographic characteristics and experiences regarding interculturality. After validating and assessing the scale’s psychometric properties, relations between different variables were explored using Pearson’s correlation, ANOVA, t Tests, and GLM procedures. We then analysed the open ended responses to gain further insight on our results. Differences among respondents are mainly equated with international experience rather than nationality or training. Respondents’ open ended replies provided us with a deeper insight on why training seems to be so ineffective in developing CQ. This is a transversal study that uses self-reporting measures; also, questionnaires were conducted in English, which was not the mother tongue of most of the respondents. This work is consistent with the CQ literature, however we argue that training mentioned by respondents systematically fails to meet some of literature’s foremost conditions for effective CQ trainings and provide clues for the implementation of more successful initiatives. With an exceptionally diverse sample, this study contributes towards the understanding of mechanisms of developing CQ among EMM and international Students. Results can be useful for selection processes, training/development of CQ and reducing dropout/turnover.