This paper presents a project consisting on the development of an Intelligent Tutoring System, for training and support concerning the development of electrical installation projects to be used by electrical engineers, technicians and students. One of the major goals of this project is to devise a teaching model based on Intelligent Tutoring techniques, considering not only academic knowledge but also other types of more empirical knowledge, able to achieve successfully the training of electrical installation design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Designing electric installation projects, demands not only academic knowledge, but also other types of knowledge not easily acquired through traditional instructional methodologies. A lot of additional empirical knowledge is missing and so the academic instruction must be completed with different kinds of knowledge, such as real-life practical examples and simulations. On the other hand, the practical knowledge detained by the most experienced designers is not formalized in such a way that is easily transmitted. In order to overcome these difficulties present in the engineers formation, we are developing an Intelligent Tutoring System (ITS), for training and support concerning the development of electrical installation projects to be used by electrical engineers, technicians and students.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The large penetration of intermittent resources, such as solar and wind generation, involves the use of storage systems in order to improve power system operation. Electric Vehicles (EVs) with gridable capability (V2G) can operate as a means for storing energy. This paper proposes an algorithm to be included in a SCADA (Supervisory Control and Data Acquisition) system, which performs an intelligent management of three types of consumers: domestic, commercial and industrial, that includes the joint management of loads and the charge/discharge of EVs batteries. The proposed methodology has been implemented in a SCADA system developed by the authors of this paper – the SCADA House Intelligent Management (SHIM). Any event in the system, such as a Demand Response (DR) event, triggers the use of an optimization algorithm that performs the optimal energy resources scheduling (including loads and EVs), taking into account the priorities of each load defined by the installation users. A case study considering a specific consumer with several loads and EVs is presented in this paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wind resource evaluation in two sites located in Portugal was performed using the mesoscale modelling system Weather Research and Forecasting (WRF) and the wind resource analysis tool commonly used within the wind power industry, the Wind Atlas Analysis and Application Program (WAsP) microscale model. Wind measurement campaigns were conducted in the selected sites, allowing for a comparison between in situ measurements and simulated wind, in terms of flow characteristics and energy yields estimates. Three different methodologies were tested, aiming to provide an overview of the benefits and limitations of these methodologies for wind resource estimation. In the first methodology the mesoscale model acts like “virtual” wind measuring stations, where wind data was computed by WRF for both sites and inserted directly as input in WAsP. In the second approach, the same procedure was followed but here the terrain influences induced by the mesoscale model low resolution terrain data were removed from the simulated wind data. In the third methodology, the simulated wind data is extracted at the top of the planetary boundary layer height for both sites, aiming to assess if the use of geostrophic winds (which, by definition, are not influenced by the local terrain) can bring any improvement in the models performance. The obtained results for the abovementioned methodologies were compared with those resulting from in situ measurements, in terms of mean wind speed, Weibull probability density function parameters and production estimates, considering the installation of one wind turbine in each site. Results showed that the second tested approach is the one that produces values closest to the measured ones, and fairly acceptable deviations were found using this coupling technique in terms of estimated annual production. However, mesoscale output should not be used directly in wind farm sitting projects, mainly due to the mesoscale model terrain data poor resolution. Instead, the use of mesoscale output in microscale models should be seen as a valid alternative to in situ data mainly for preliminary wind resource assessments, although the application of mesoscale and microscale coupling in areas with complex topography should be done with extreme caution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho apresentado explora o aproveitamento da energia solar para suprir as necessidades energéticas, tanto elétricas como térmicas, de uma habitação tipo 3, recorrendo ao uso de coletores solares, em que o fluido de trabalho é água. As necessidades elétricas serão supridas através da produção de energia com recurso a um ciclo de Rankine, em que fluido de trabalho é um frigorigénio aquecido através de um permutador cujo fluido quente será uma mistura, de água com anticongelante, aquecida pelo coletor solar. Por outro lado, as necessidades térmicas serão satisfeitas através do calor libertado no ciclo de Rankine. Na instalação solar estará integrado um acumulador térmico com apoio energético, caldeira elétrica, que funcionará nas situações em que coletor seja insuficiente para satisfazer as necessidades térmicas. No final será feita uma avaliação económica para que possa atestar a viabilidade económica do projeto, tendo em conta os seus custos totais versus as poupanças energéticas que este sistema origina.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação descreve o estudo, concepção e desenvolvimento de uma aplicação baseada no sistema operativo Windows 8 que interage com um sistema domótico KNX, permitindo ao utilizador controlar a sua instalação domótica. Esta proposta, que combina a área de integração/instalação de sistemas domóticos e a de desenvolvimento de aplicações para Windows 8 e Windows 8 Phone, constitui um desafio particularmente interessante para quem tem experiência profissional nas duas áreas. A domótica surgiu na década de 70 como uma aplicação da eletrónica e das tecnologias da informação às instalações residenciais, comerciais e industriais. Esta nova área desencadeou uma revolução, não só, ao nível da produção e comercialização, mas, também, do ponto de vista do utilizador, ao promover a comodidade, segurança, personalização e o controlo de pessoas e bens. Os smartphones e tablets vieram permitir que o desenvolvimento de aplicações móveis de interacção com os sistemas domóticos. Ao longo desta dissertação são descritas e analisadas as múltiplas áreas de intervenção da domótica assim como as diferentes tecnologias de aplicação e mercados. Também são analisados os sistemas operativos que existentes, as respetivas cotas de mercado e os tipos de dispositivos disponíveis. Por último, a aplicação foi concebida, implementada e testada para verificar a correcta interacção com o sistema domótico KNX e as funcionalidades de controlo da instalação domótica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A prática de exercício físico é considerado condição essencial para a manutenção de uma boa saúde. A faixa etária de frequentadores de ginásios inclui utentes desde os 8 aos 80 anos, incluindo assim os grupos mais sensíveis à poluição do ar interior. Embora exista legislação específica para ginásios, nomeadamente para as condições de implementação, a mesma é reduzida e não contempla a qualidade do ar interior (QAI). O objetivo geral deste estudo consistiu na avaliação da QAI de quatro ginásios existentes na área metropolitana do Porto. O período de amostragem realizou-se entre 2 de Maio e 20 de Junho 2014 e, após a caracterização dos ginásios, foram monitorizados os seguintes parâmetros: partículas ultrafinas (< 100 nm), matéria particulada suspensa no ar de frações PM1, PM2,5, PM4 e PM10, dióxido de carbono, monóxido de carbono, ozono, compostos orgânicos voláteis, formaldeído, temperatura ambiente e humidade relativa durante 24 h/dia em salas com diferentes actividades (sala de musculação e cardiofitness e sala de aulas de grupo). Os resultados da avaliação dos parâmetros físicos e químicos foram comparados com os limiares de proteção e margem de tolerância do Decreto-Lei nº 118/2013 de 20 de Agosto, a Portaria nº 353-A/2013 de 4 de Dezembro e o Diploma que regula a construção, instalação e funcionamento dos ginásios. Os poluentes com maiores níveis de excedência são o dióxido de carbono, compostos orgânicos voláteis e as partículas PM2,5. As excedências devem-se essencialmente à sobrelotação das salas, excesso de atividade física e ventilação insuficiente. A localização da instalação dos ginásios é também um fator de extrema importância, sendo recomendado que este se situe em local pouco influenciado pelo tráfego automóvel, assim como, afastado de locais de possível interferência devido às atividades presentes, como é o caso da restauração existente em centros comerciais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Em Portugal existem muitos espaços comerciais e industriais em que as necessidades térmicas de arrefecimento são muito superiores às necessidades de aquecimento devido aos ganhos internos que advêm da existência de equipamentos e da iluminação dos edifícios, assim como, da presença das pessoas. A instalação de sistemas convencionais de ar condicionado para espaços comerciais e industriais de grande dimensão está geralmente associada ao transporte de grandes caudais de ar, e consequentemente, a elevados consumos de energia primária, e também, elevados custos de investimento, de manutenção e de operação. O arrefecedor evaporativo é uma solução de climatização com elevada eficiência energética, cujo princípio de funcionamento promove a redução do consumo de energia primária nos edifícios. A metodologia utilizada baseou-se na criação de uma ferramenta informática de simulação do funcionamento de um protótipo de um arrefecedor evaporativo. Foi efetuada a modelação matemática das variáveis dinâmicas envolvidas, dos processos de transferência de calor e de massa, assim como dos balanços de energia que ocorrem no arrefecedor evaporativo. A ferramenta informática desenvolvida permite o dimensionamento do protótipo do arrefecedor evaporativo, sendo determinadas as caraterísticas técnicas (potência térmica, caudal, eficiência energética, consumo energético e consumo e água) de acordo com o tipo de edifício e com as condições climatéricas do ar exterior. Foram selecionados três dimensionamentos de arrefecedores evaporativos, representativos de condições reais de uma gama baixa, média e elevada de caudais de ar. Os resultados obtidos nas simulações mostram que a potência de arrefecimento (5,6 kW, 16,0 kW e 32,8 kW) e o consumo de água (8 l/h, 23,9 l/h e 48,96 l/h) aumentam com o caudal de ar do arrefecedor, 5.000 m3/h, 15.000 m3/h e 30.000 m3/h, respetivamente. A eficácia de permuta destes arrefecedores evaporativos, foi de 69%, 66% e 67%, respetivamente. Verificou-se que a alteração de zona climática de V1 para V2 implicou um aumento de 39% na potência de arrefecimento e de 20% no consumo de água, e que, a alteração de zona climática de V2 para V3 implicou um aumento de 39% na potência de arrefecimento e de 39% no consumo de água. O arrefecedor evaporativo apresenta valores de consumo de energia elétrica entre 40% a 80% inferiores aos dos sistemas de arrefecimento convencionais, sendo este efeito mais intenso quando a zona climática de verão se torna mais severa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gradually smart grids and smart meters are closer to the home consumers. Several countries has developed studies focused in the impacts arising from the introduction of these technologies and one of the main advantages are related to energy efficiency, observed through the awareness of the population on behalf of a more efficient consumption. These benefits are felt directly by consumers through the savings on electricity bills and also by the concessionaires through the minimization of losses in transmission and distribution, system stability, smaller loading during peak hours, among others. In this article two projects that demonstrate the potential energy savings through smart meters and smart grids are presented. The first performed in Korea, focusing on the installation of smart meters and the impact of use of user interfaces. The second performed in Portugal, focusing on the control of loads in a residence with distributed generation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O setor dos edifícios representa perto de 40% do consumo de energia final na Europa e cerca de 30% no caso de Portugal [1]. Para fazer face a esta situação foi elaborada e aprovada uma Diretiva Europeia Relativa ao Desempenho Energético dos Edifícios, que foi transposta a nível nacional através de um pacote legislativo assente em três pilares, nomeadamente o Sistema Nacional de Certificação Energética e da Qualidade do Ar Interior (SCE), o Regulamento dos Sistemas Energéticos de Climatização em Edifícios (RSECE) e o Regulamento das Características de Comportamento Térmico dos Edifícios (RCCTE). Atuando ao nível da eficiência energética o consumo de energia nos edifícios pode diminuir para metade, para tal é necessário proceder-se à execução de auditorias energéticas para poder determinar as soluções mais adequadas de forma a reduzir os desperdícios e custos associados ao consumo de energia. Nesta dissertação desenvolveu-se uma metodologia para a realização de auditorias energéticas em edifícios que assenta essencialmente em cinco etapas, nomeadamente: o planeamento, a análise do estado atual, o planeamento estratégico, a elaboração de relatório e a implementação de medidas com acompanhamento de resultados. A aplicação desta metodologia constitui uma grande ajuda na realização de auditorias energéticas conferindo uma maior qualidade à sua execução. De forma a validar a metodologia efetuada foi realizado o estudo de três casos práticos relativos a três agências bancárias (denominadas de A, B e C), em que duas delas pertencem a um projeto de eficiência energética que engloba 50 agências e uma outra que pertence a um outro projeto de apenas 3 agências. A metodologia segue a mesma lógica para as três agências, no entanto, em termos de validação, a última instalação baseia-se nos consumos dos dados monitorizados em contínuo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atualmente a energia é considerada um vetor estratégico nas diversas organizações. Assim sendo, a gestão e a utilização racional da energia são consideradas instrumentos fundamentais para a redução dos consumos associados aos processos de produção do sector industrial. As ações de gestão energética não deverão ficar pela fase do projeto das instalações e dos meios de produção, mas sim acompanhar a atividade da Empresa. A gestão da energia deve ser sustentada com base na realização regular de diagnósticos energéticos às instalações consumidoras e concretizada através de planos de atuação e de investimento que apresentem como principal objetivo a promoção da eficiência energética, conduzindo assim à redução dos respetivos consumos e, consequentemente, à redução da fatura energética. Neste contexto, a utilização de ferramentas de apoio à gestão de energia promovem um consumo energético mais racional, ou seja, promovem a eficiência energética e é neste sentido que se insere este trabalho. O presente trabalho foi desenvolvido na Empresa RAR Açúcar e apresentou como principais objetivos: a reformulação do Sistema de Gestão de Consumos de Energia da Empresa, a criação de um modelo quantitativo que permitisse ao Gestor de Energia prever os consumos anuais de água, fuelóleo e eletricidade da Refinaria e a elaboração de um plano de consumos para o ano de 2014 a partir do modelo criado. A reformulação do respetivo Sistema de Gestão de Consumos resultou de um conjunto de etapas. Numa primeira fase foi necessário efetuar uma caraterização e uma análise do atual Sistema de Gestão de Consumos da Empresa, sistema composto por um conjunto de sete ficheiros de cálculo do programa Microsoft Excel©. Terminada a análise, selecionada a informação pertinente e propostas todas as melhorias a introduzir nos ficheiros, procedeu-se à reformulação do respetivo SGE, reduzindo-se o conjunto de ficheiros de cálculo para apenas dois ficheiros, um onde serão efetuados e visualizados todos os registos e outro onde serão realizados os cálculos necessários para o controlo energético da Empresa. O novo Sistema de Gestão de Consumos de Energia será implementado no início do ano de 2015. Relativamente às alterações propostas para as folhas de registos manuais, estas já foram implementadas pela Empresa. Esta aplicação prática mostrou-se bastante eficiente uma vez que permitiu grandes melhorias processuais nomeadamente, menores tempos de preenchimento das mesmas e um encurtamento das rotas efetuadas diariamente pelos operadores. Através do levantamento efetuado aos diversos contadores foi possível identificar todas as áreas onde será necessário a sua instalação e a substituição de todos os contadores avariados, permitindo deste modo uma contabilização mais precisa de todos os consumos da Empresa. Com esta reestruturação o Sistema de Gestão de Consumos tornou-se mais dinâmico, mais claro e, principalmente, mais eficiente. Para a criação do modelo de previsão de consumos da Empresa foi necessário efetuar-se um levantamento dos consumos históricos de água, eletricidade, fuelóleo e produção de açúcar de dois anos. Após este levantamento determinaram-se os consumos específicos de água, fuelóleo e eletricidade diários (para cada semana dos dois anos) e procedeu-se à caracterização destes consumos por tipo de dia. Efetuada a caracterização definiu-se para cada tipo de dia um consumo específico médio com base nos dois anos. O modelo de previsão de consumos foi criado com base nos consumos específicos médios dos dois anos correspondentes a cada tipo de dia. Procedeu-se por fim à verificação do modelo, comparando-se os consumos obtidos através do modelo (consumos previstos) com os consumos reais de cada ano. Para o ano de 2012 o modelo apresenta um desvio de 6% na previsão da água, 12% na previsão da eletricidade e de 6% na previsão do fuelóleo. Em relação ao ano de 2013, o modelo apresenta um erro de 1% para a previsão dos consumos de água, 8% para o fuelóleo e de 1% para a eletricidade. Este modelo permitirá efetuar contratos de aquisição de energia elétrica com maior rigor o que conduzirá a vantagens na sua negociação e consequentemente numa redução dos custos resultantes da aquisição da mesma. Permitirá também uma adequação dos fluxos de tesouraria à necessidade reais da Empresa, resultante de um modelo de previsão mais rigoroso e que se traduz numa mais-valia financeira para a mesma. Foi também proposto a elaboração de um plano de consumos para o ano de 2014 a partir do modelo criado em função da produção prevista para esse mesmo ano. O modelo apresenta um desvio de 24% na previsão da água, 0% na previsão da eletricidade e de 28% na previsão do fuelóleo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente estágio foi desenvolvido na Britafiel. Um dos projectos em que a Empresa se encontra envolvida é o STOCO, pretendendo implementar à escala industrial um processo de coloração de pedra granítica natural para fins decorativos. Foi neste projecto que se enquadrou o estágio. O tema do estágio centra-se no processo de coloração de granito tendo como principal foco a implementação de um processo industrial de produção de granito colorido. O projecto STOCO nasce da necessidade de complementar a actividade da empresa com produtos de maior valor acrescentado para valorização da matéria-prima de base, o granito. STOCO, resultante de Stone Color, é o nome dado ao projecto e ao novo produto que é granito colorido, sob a forma de brita. Pretende-se obter um produto amigo do ambiente e com boas características: manter a textura natural da pedra granítica e assegurar uma boa resistência a factores agressivos. Estudos prévios de qualidade e de toxicidade mostraram que o produto STOCO desenvolvido até então apresenta um bom comportamento face a agressões climatéricas e que não compromete a vida das espécies usadas nos testes (peixes). Em relação aos lixiviados e resíduos da pedra colorida STOCO, estes não apresentaram qualquer problema ambiental, sendo considerado um produto amigo do ambiente. À data de início do presente trabalho estava em funcionamento um equipamento protótipo de produção de granito colorido (100 kg/partida), sendo a instalação e o arranque da unidade industrial (3 ton/h) concretizados no início de 2014, já no decorrer deste trabalho. Os objectivos cumpridos no âmbito deste trabalho foram então a implementação de uma linha industrial de produção de brita colorida, avaliação técnica do processo e do custo industrial de produção associado às matérias-primas. Neste relatório é descrito o processo inicial adoptado e apresentam-se as alterações efectuadas para melhoria do processo produtivo. Resolveram-se problemas como: definição e instalação de equipamentos complementares para a entrada e a saída da brita no equipamento industrial; pó excessivo na brita; cheiro intenso a gás e elevado ruído; adequação do sistema de pintura; e secagem incompleta da brita. Alguns destes problemas não foram totalmente resolvidos, mas sim minimizados. O equipamento industrial necessita ainda de alterações em diversas áreas, que foram identificadas e para as quais são feitas sugestões de melhoria. Conseguiu-se ainda fazer alguns testes para uma possível substituição de alguns constituintes da tinta. Os componentes que entram na composição base da tinta aquosa, são de modo simplificado: ligante, pigmento, solvente e aditivos. Os constituintes que mais encarecem a tinta, e consequentemente o processo em causa, são o ligante e o pigmento. Os estudos efectuados precisam de ser aprofundados, na tentativa de melhorar o processo minimizando os custos de produção. Formalizaram-se os procedimentos escritos de produção STOCO tanto para o protótipo como para o processo industrial e elaborou-se uma ficha técnica de produto para a brita colorida STOCO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A eficiência energética tem um papel de importância crescente devido a questões ambientais e ao aumento dos custos energéticos. Recentemente foram tomadas medidas para regular o consumo e o fornecimento de energia reativa em Portugal, que tornaram mais rigorosas as condições de faturação. O custo crescente da energia e a implementação das smart grids apontam para um futuro de maior rigor sobre a utilização da energia reativa. Não será de estranhar que as regras de faturação sejam mais severas daqui a uns anos. O desenvolvimento tecnológico nas áreas da análise da energia e nas formas de controlo da compensação de energia reativa permitem resultados muito mais eficazes que aqueles apresentados pelos vulgares sistemas a contactores que constituem a maioria dos cenários. Apesar de terem um custo inicial superior, os sistemas de compensação do fator de potência com filtragem passiva de harmónicos, desde que projetados corretamente, trazem vantagens evidentes na sua exploração a longo prazo. Com este trabalho pretende-se promover a sensibilização para o uso de sistemas mais eficientes na compensação de energia reativa e para que estes sejam projetados mais à medida das necessidades de cada local. Também se demonstra a extrema importância da adequação destes sistemas à qualidade de energia do local, principalmente em termos de conteúdo harmónico. Desta forma, os sistemas serão mais flexíveis em termos de utilização e possibilitam a sua adaptação às necessidades mesmo que as regras de faturação de energia reativa se tornem mais rigorosas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pela importância que os edifícios têm na utilização de energia, a avaliação do seu desempenho energético é de grande relevância, uma vez que, em grande parte, passa por estes a concretização das metas europeias definidas para 2020, no que concerne à diminuição da utilização de energia. Tendo em conta que os edifícios representam 40% do consumo de energia total, e estando o sector em expansão, esta realidade obriga a uma procura de soluções integradas de arquitetura e engenharia que promovam a sustentabilidade dos edifícios. Foi efetuado um estudo num edifício constituído por dois corpos, um mais antigo que funciona como centro de dia e um mais recente que funciona como lar, localizados no concelho de Matosinhos, onde se identificaram os pontos de maior consumo energético, para os quais foram sugeridas alterações no sentido de baixar os custos com a factura energética. Nesta dissertação foi utilizado um software de simulação dinâmica para avaliação do comportamento térmico do edifício nas condições atuais e, posteriormente, foram simulados outros cenários com alterações ao nível da envolvente térmica dos edifícios e dos seus sistemas técnicos, que permitiram identificar algumas medidas de melhoria de eficiência energética. As medidas de melhoria sugeridas implicam uma redução energética, ao nível do consumo de água quente sanitária, consumo de gás natural e electricidade. De entre essas medidas, e com um payback inferior a 8 anos e meio, destacam-se a instalação de redutores de caudal, a substituição da caldeira e da bomba de recirculação, a instalação de painéis solares térmicos e a redução da quantidade de lâmpadas.