6 resultados para high-resolution continuum source flame atomic spectrometry

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mineral content (phosphorous (P), potassium (K), sodium (Na), calcium (Ca), magnesium (Mg), iron (Fe), manganese (Mn), zinc (Zn) and copper (Cu)) of eight ready-to-eat baby leaf vegetables was determined. The samples were subjected to microwave-assisted digestion and the minerals were quantified by High-Resolution Continuum Source Atomic Absorption Spectrometry (HR-CS-AAS) with flame and electrothermal atomisation. The methods were optimised and validated producing low LOQs, good repeatability and linearity, and recoveries, ranging from 91% to 110% for the minerals analysed. Phosphorous was determined by a standard colorimetric method. The accuracy of the method was checked by analysing a certified reference material; results were in agreement with the quantified value. The samples had a high content of potassium and calcium, but the principal mineral was iron. The mineral content was stable during storage and baby leaf vegetables could represent a good source of minerals in a balanced diet. A linear discriminant analysis was performed to compare the mineral profile obtained and showed, as expected, that the mineral content was similar between samples from the same family. The Linear Discriminant Analysis was able to discriminate different samples based on their mineral profile.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present paper reports the amount and estimated daily mineral intake of nine elements (Ca, Mg, K, Na, P, Fe, Mn, Cr and Ni) in commercial instant coffees and coffee substitutes (n = 49). Elements were quantified by high-resolution continuum source flame (HR-CS-FAAS) and graphite furnace (HR-CS-GFAAS) atomic absorption spectrometry, while phosphorous was evaluated by a standard vanadomolybdophosphoric acid colorimetric method. Instant coffees and coffee substitutes are rich in K, Mg and P (>100 mg/100 g dw), contain Na, Ca and Fe in moderate amounts (>1 mg/100 g), and trace levels of Cr and Ni. Among the samples analysed, plain instant coffees are richer in minerals (p < 0.001), except for Na and Cr. Blends of coffee substitutes (barley, malt, chicory and rye) with coffee (20–66%) present intermediate amounts, while lower quantities are found in substitutes without coffee, particularly in barley. From a nutritional point of view the results indicate that the mean ingestion of two instant beverages per day (total of 4 g instant powder), either with or without coffee, cannot be regarded as important sources of minerals to the human diet, although providing a supplementation of some minerals, particularly Mg and Mn in instant coffees. Additionally, and for authentication purposes, the correlations observed between some elements and the coffee percentage in the blends, with particular significance for Mg amounts, provides a potential tool for the estimation of coffee in substitute blends.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Espresso coffee beverages prepared from pure origin roasted ground coffees from the major world growing regions (Brazil, Ethiopia, Colombia, India, Mexico, Honduras, Guatemala, Papua New Guinea, Kenya, Cuba, Timor, Mussulo and China) were characterized and compared in terms of their mineral content. Regular consumption of one cup of espresso contributes to a daily mineral intake varying from 0.002% (sodium; Central America) to 8.73% (potassium; Asia). The mineral profiles of the espresso beverages revealed significant inter- and intra-continental differences. South American pure origin coffees are on average richer in the analyzed elements except for calcium, while samples from Central America have generally lower mineral amounts (except for manganese). Manganese displayed significant differences (p < 0.05) among the countries of each characterized continent. Intercontinental and inter-country discrimination between the major world coffee producers were achieved by applying canonical discriminant analysis. Manganese and calcium were found to be the best chemical descriptors for origin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gamma radiations measurements were carried out in the vicinity of a coal-fired power plant located in the southwest coastline of Portugal. Two different gamma detectors were used to assess the environmental radiation within a circular area of 20 km centred in the coal plant: a scintillometer (SPP2 NF, Saphymo) and a high purity germanium detector (HPGe, Canberra). Fifty urban and suburban measurements locations were established within the defined area and two measurements campaigns were carried out. The results of the total gamma radiation ranged from 20.83 to 98.33 counts per second (c.p.s.) for both measurement campaigns and outdoor doses rates ranged from 77.65 to 366.51 Gy/h. Natural emitting nuclides from the U-238 and Th-232 decay series were identified as well as the natural emitting nuclide K-40. The radionuclide concentration from the uranium and thorium series determined by gamma spectrometry ranged from 0.93 to 73.68 Bq/kg, while for K-40 the concentration ranged from 84.14 to 904.38 Bq/kg. The obtained results were used primarily to define the variability in measured environmental radiation and to determine the coal plant’s influence in the measured radiation levels. The highest values were measured at two locations near the power plant and at locations between the distance of 6 and 20 km away from the stacks, mainly in the prevailing wind direction. The results showed an increase or at least an influence from the coal-fired plant operations, both qualitatively and quantitatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Actualmente tem-se verificado um grande aumento na procura e a utilização de produtos naturais contendo extractos de algas, com fins medicinais, sendo cada vez maior a diversidade de oferta desses produtos, vendidos em ervanária e afins. A bibliografia tem mostrado que as algas têm capacidade de acumulação de metais pesados. As algas, sendo organismos aquáticos, estão sujeitas a contaminações dos locais (não identificados) de onde provêm. O controlo e fiscalização para estes produtos é praticamente inexistente. O objectivo deste projecto foi o desenvolvimento de metodologias analíticas com vista à quantificação de metais em infusões de chás e ervas aromáticas. Foram analisadas 9 amostras: uma de chá verde, uma de chá preto, uma infusão de lima, uma de camomila, uma mistura de chá com ervas e quatro misturas contendo algas. A espectrofotometria de absorção atómica é o método de referência para a análise de metais. Neste trabalho foi utilizado um espectrofotómetro de absorção atómica com fonte de radiação contínua e monocromador de alta resolução. Sendo esta uma tecnologia inovadora foi necessário desenvolver metodologias para os métodos de análise. A atomização em chama foi a técnica utilizada para a quantificação do cálcio, potássio, magnésio, manganês e sódio. A atomização electrotérmica foi usada para o cádmio, cobalto, crómio, cobre, níquel e chumbo. Tendo em conta os limites legislados (Decreto-Lei Nº306/2007 de 27 de Agosto) obtiveram-se teores preocupantes para o níquel (iguais ou superiores ao limite legislado) em todas as amostras analisadas e para o manganês em duas das amostras (chá verde e chá preto). Todas as amostras contendo algas apresentaram teores de Ca, Mg e Na superiores aos das restantes. Para os restantes elementos não foi possível relacionar as concentrações com a composição das infusões, em particular a presença de algas.