10 resultados para hög måluppfyllelse
em Instituto Politécnico do Porto, Portugal
Resumo:
Concentrations of eleven trace elements (Al, As, Cd, Cr, Co, Hg, Mn, Ni, Pb, Se, and Si) were measured in 39 (natural and flavoured) water samples. Determinations were performed using graphite furnace electrothermetry for almost all elements (Al, As, Cd, Cr, Co, Mn, Ni, Pb, and Si). For Se determination hydride generation was used, and cold vapour generation for Hg. These techniques were coupled to atomic absorption spectrophotometry. The trace element content of still or sparkling natural waters changed from brand to brand. Significant differences between natural still and natural sparkling waters (p<0.001) were only apparent for Mn. The Mann–Whitney U-test was used to search for significant differences between flavoured and natural waters. The concentration of each element was compared with the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. It was shown that flavoured waters generally increase the trace element content. The addition of preservatives and acidifying regulators had a significant influence on Mn, Co, As and Si contents (p<0.05). Fruit juice can also be correlated to the increase of Co and As. Sweeteners did not provide any significant difference in Mn, Co, Se and Si content.
Resumo:
An optical fiber sensor for Hg(II) in aqueous solution based on sol–gel immobilized carbon dots nanoparticles functionalized with PEG200 and N-acetyl-l-cysteine is described. This sol–gel method generated a thin (about 750 nm), homogenous and smooth (roughness of 2.7±0.7 a˚ ) filmthat immobilizes the carbon dots and allows reversible sensing of Hg(II) in aqueous solution. A fast (less than 10 s), reversible and stable (the fluorescence intensity measurements oscillate less than 1% after several calibration cycles) sensor system was obtained. The sensor allow the detection of submicron molar concentrations of Hg(II) in aqueous solution. The fluorescence intensity of the immobilized carbon dots is quenched by the presence of Hg(II) with a Stern-Volmer constant (pH = 6.8) of 5.3×105M−1.
Resumo:
We report within this paper the development of a fiber-optic based sensor for Hg(II) ions. Fluorescent carbon nanoparticles were synthesized by laser ablation and functionalized with PEG200 and N-acetyl-l-cysteine so they can be anionic in nature. This characteristic facilitated their deposition by the layer-by-layer assembly method into thin alternating films along with a cationic polyelectrolyte, poly(ethyleneimine). Such films could be immobilized onto the tip of a glass optical fiber, allowing the construction of an optical fluorescence sensor. When immobilized on the fiber-optic tip, the resultant sensor was capable of selectively detecting sub-micromolar concentrations of Hg(II) with an increased sensitivity compared to carbon dot solutions. The fluorescence of the carbon dots was quenched by up to 44% by Hg(II) ions and interference from other metal ions was minimal.
Resumo:
O aumento da utilização do mercúrio, Hg, tanto para fins industriais como na aplicação de compostos mercuriais na agricultura, originaram um aumento significativo da contaminação ambiental, especialmente das águas e dos alimentos. Foi aprofundado o estudo sobre o mercúrio, nomeadamente as suas principais fontes de emissão, a sua toxicidade, os principais efeitos nos seres humanos, algumas medidas preventivas, os limites máximos que a legislação permite, que no caso das águas analisadas é de 0,001mg/L, os métodos analíticos para a sua determinação e alguns métodos de amostragem, tanto para o mercúrio em águas como em sedimentos. Em Almadén (Espanha), existe uma mina que pode ser considerada como uma das maiores anomalias geoqímica de mercúrio na Terra. Com este trabalho pretendeu-se perceber a possível existência de mercúrio nas águas termais ao longo da zona de falha Penacova-Régua-Verin e avaliar a existência de uma relação entre os níveis de mercúrio e o seu contexto geológico. Neste trabalho, foi desenvolvido um método simples para a determinação dos níveis de mercúrio em águas, utilizando a espectrometria de absorção atómica de fonte contínua de alta resolução acoplado à técnica de vapor frio. O objectivo deste trabalho foi avaliar os níveis de mercúrio existente em algumas águas engarrafadas e termais. Os limites de detecção da técnica utilizada foram 0,0595 μg/L e os de quantificação foram 0,2100 μg/L. Depois de analisadas as amostras verificou-se que os níveis de mercúrio encontrados nas águas eram inferiores ao limite de quantificação da técnica e por isso, não foi possível extrapolar qualquer relação entre os níveis de mercúrio e as alterações do fundo geológico. Como o limite de quantificação é inferior ao limite máximo permitido por lei, pode então dizer-se que todas as águas se encontram abaixo do limite máximo permitido.
Resumo:
O presente trabalho pretendeu desenvolver e testar um sensor óptico para detectar ciclamato de sódio, um adoçante artificial utilizado nas bebidas em geral. A primeira abordagem neste sentido baseou-se na preparação de um sensor óptico através da formação de complexos corados entre o ciclamato e várias espécies metálicas, nomeadamente Hg(II), Ba(II), Fe(II), Ag(II), Pb(II), Cd(II), Mn (II), Ni(II), Cu(II), Co(II), Sn(II) e Mg(II). Perante a ausência de resultados satisfatórios optou-se por explorar a acção do ciclamato de sódio na transferência/partilha de um corante entre duas fases líquidas imiscíveis. As fases líquidas utilizadas foram a água e o clorofórmio. Testaram-se várias famílias de corantes mas só uma classe se mostrou com as características apropriadas para o objectivo pretendido. Dentro dessa família de corantes, seleccionou-se aquele que, à partida, garantiu o melhor desempenho. O sensor foi testado em diferentes condições de pH e também na presença de potenciais interferentes de forma a estabelecer as melhores condições de utilização. O método mostrou-se bastante simples de executar, rápido na obtenção de resultados e com boas características para ser avaliado visualmente, mas sempre de acordo com os critérios de objectividade que um trabalho deste tipo requer. Além o disso permitiu ser calibrado de uma forma rápida e simples, características essenciais para a aplicação deste método na despistagem de ciclamato em análises de rotina. O método desenvolvido foi ainda aplicado à análise de vinho dopado com diferentes concentrações de ciclamato de sódio. Destes testes verificou-se a necessidade de optimização do método através da introdução de outras substâncias na fase não aquosa diminuindo a vulnerabilidade do sensor a outros interferentes. Como conclusão, o método correspondeu às expectativas, mostrando-se viável para aplicação à análise de vinhos, ainda com uma margem significativa de desenvolvimento no sentido de o tornar mais fiável e preciso.
Resumo:
In this work we isolated from soil and characterized several bacterial strains capable of either resisting high concentrations of heavy metals (Cd2+ or Hg2+ or Pb2+) or degrading the common soil and groundwater pollutants MTBE (methyl-tertbutyl ether) or TCE (trichloroethylene). We then used soil microcosms exposed to MTBE (50 mg/l) or TCE (50 mg/l) in the presence of one heavy metal (Cd 10 ppm or Hg 5 ppm or Pb 50 or 100 ppm) and two bacterial isolates at a time, a degrader plus a metalresistant strain. Some of these two-membered consortia showed degradation efficiencies well higher (49–182% higher) than those expected under the conditions employed, demonstrating the occurrence of a synergetic relationship between the strains used. Our results show the efficacy of the dual augmentation strategy for MTBE and TCE bioremediation in the presence of heavy metals.
Resumo:
Introduction: Lower Respiratory Tract Infections (LRTIs) are highly prevalent in institutionalised people with dementia, constituting an important cause of morbidity and mortality. Computerised auscultation of Adventitious Lung Sounds (ALS) has shown to be objective and reliable to assess and monitor respiratory diseases, however its application in people with dementia is unknown. Aim: This study characterised ALS (crackles and wheezes) in institutionalised people with dementia. Methods: An exploratory descriptive study, including 6 long-term care institutions was conducted. The sample included a dementia group (DG) of 30 people with dementia and a match healthy group (HG) of 30 elderly people. Socio-demographic and anthropometric data, cognition, type and severity of dementia, cardio-respiratory parameters, balance, mobility and activities and participation were collected. Lung sounds were recorded with a digital stethoscope following Computerised Respiratory Sound Analysis (CORSA) guidelines. Crackles’ location, number (N), frequency (F), two-cycle duration (2CD), initial deflection width (IDW) and largest deflection width (LDW) and wheezes’ number (N), ratio (R) and frequency (F) were analysed per breathing phase. Statistical analyses were performed using PASW Statistics(v.19). Results: There were no significant differences between the two groups in relation to the mean N of crackles during inspiration and expiration in both trachea and thorax. DG trachea crackles had significant higher F during inspiration and lower IDW, 2CD and LDW during expiration when compared with HG. At the thorax, the LDW during inspiration was also significantly lower in the DG. A significant higher N of inspiratory wheezes was found in the HG. Both groups had a low ratio of high frequency wheezes. Conclusion: Computerised analyses of ALS informed on the respiratory system and function of people with dementia and elderly people. Hence, this could be the step towards prevention, early diagnosis and continuous monitoring of respiratory diseases in people with cognitive impairment.
Resumo:
This paper aims to survey metal concentrations in soils in the vicinity of a coal-firedpower plant located in southwest of Portugal. Two annual sampling campaigns were carried out to measure a hypothetical soil contamination around the coal plant. The sampling area was divided into two subareas, both centered in the emission source, delimited by two concentric circles with radius of 6 km and 20 km. About 40 samplings points were defined in the influence area. Metals measurements were performed with a portable analytical X-ray dispersive energy fluorescence spectrometer identifying about 20 different elements in each sampling point. The most relevant elements measured included As, Cu, Fe, Hg, Pb, Ti and Zn in both sampling areas. Considering the results obtained in the first sampling campaign, arsenic is predominantly higher within the 6-20 km sampling area. The second sampling campaign showed that both sampling areas presented relatively similar metal concentrations except for Fe, Mn, Sr and Zn which concentration is higher within the 6-20 km sampling area. Also, As, Fe, Mn and Ti concentrations decreased significantly from the first to the second sampling campaign and their concentration were predominately higher in the NE-E and E-SE directions.
Resumo:
Proceedings of the 13th International UFZ-Deltares Conference on Sustainable Use and Management of Soil, Sediment and Water Resources - 9–12 June 2015 • Copenhagen, Denmark
Resumo:
BACKGROUND AND PURPOSE: A single bout of aerobic exercise acutely decreases blood pressure, even in older adults with hypertension. Nonetheless, blood pressure responses to aerobic exercise in very old adults with hypertension have not yet been documented. Therefore, this study aimed to assess the effect of a single session of aerobic exercise on postexercise blood pressure in very old adults with hypertension. METHODS: Eighteen older adults with essential hypertension were randomized into exercise (N = 9, age: 83.4 ± 3.2 years old) or control (N = 9, age: 82.7 ± 2.5 years old) groups. The exercise group performed a session of aerobic exercise constituting 2 periods of 10 minutes of walking at an intensity of 40% to 60% of the heart rate reserve. The control group rested for the same period of time. Anthropometric variables and medication status were evaluated at baseline. Heart rate and systolic and diastolic blood pressures were measured at baseline, after exercise, and at 20 and 40 minutes postexercise. RESULTS: Systolic blood pressure showed a significant interaction for group × time (F3,24 = 6.698; P = .002; ηp = 0.153). In the exercise group, the systolic blood pressure at 20 (127.3 ± 20.9 mm Hg) and 40 minutes (123.7 ± 21.0 mm Hg) postexercise was significantly lower in comparison with baseline (135.6 ± 20.6 mm Hg). Diastolic blood pressure did not change. Heart rate was significantly higher after the exercise session. In the control group, no significant differences were observed. CONCLUSIONS: A single session of aerobic exercise acutely reduces blood pressure in very old adults with hypertension and may be considered an important nonpharmacological strategy to control hypertension in this age group.