9 resultados para express care
em Instituto Politécnico do Porto, Portugal
Resumo:
This study examined the joint effects of home environment and center-based child care quality on children’s language, communication, and early literacy development, while also considering prior developmental level. Participants were 95 children (46 boys), assessed as toddlers (mean age = 26.33 months;Time 1) and preschoolers (mean age = 68.71 months; Time 2) and their families. At both times, children attended center-based child care classrooms in the metropolitan area of Porto, Portugal. Results from hierarchical linear models indicated that home environment and preschool quality, but not center-based toddler child care quality, were associated with children’s language and literacy outcomes at Time 2. Moreover, the quality of preschool classrooms moderated the association between home environment quality and children’s language and early literacy skills – but not communication skills – at Time 2, suggesting the positive cumulative effects of home environment and preschool quality. Findings further support the existence of a detrimental effect of low preschool quality on children’s language and early literacy outcomes: positive associations among home environment quality and children’s developmental outcomes were found to reduce substantially when children attended low-quality preschool classrooms.
Resumo:
A reforma dos cuidados de saúde primários (CSP), iniciada em 2005, visa melhorar o desempenho dos centros de saúde através da reorganização dos serviços em várias unidades funcionais, no sentido de resolver os problemas tendo em conta as necessidades a satisfazer, complementando-se entre si e assumindo compromissos de acessibilidade e qualidade nos cuidados de saúde prestados. Ao mesmo tempo, são criados órgãos de gestão e governação clínica que nunca antes existiram nos CSP, envolvendo a participação da comunidade. A optimização da gestão e da governação clínica permitiu organizar os serviços de saúde em Agrupamentos de Centros de Saúde (AGES), dando-lhes poderes e responsabilidades para solucionarem problemas e tomarem as decisões acertadas e céleres, já que conhecem melhor as necessidades de saúde das populações. As relações burocráticas são substituídas por relações de contratualidade, orientadas para obter melhores resultados em saúde. Partindo destes pressupostos, o estudo realizado pretende analisar a percepção de profissionais de saúde quanto à política de humanização dos CSP, bem como, identificar/construir indicadores que avaliem essa política, sendo um estudo de carácter exploratório e descritivo, à luz de uma abordagem qualitativa. Participaram neste estudo cinco profissionais de saúde da Administração Regional de Saúde (ARS) do Norte, lP, do Departamento de Contratualização, Departamento de Estudos e Planeamento da ARS Norte e do AGES Tâmega 11 - Vale Sousa Sul, seleccionados por conveniência e inquiridos por entrevista semi-estruturada. Os dados foram tratados através da análise de conteúdo com o apoio informático NVivo9. Os resultados apresentados, com base nas entrevistas realizadas aos participantes no estudo, sustentam que os actuais indicadores quantitativos contratualizados com as unidades funcionais, expressam a política de humanização num serviço de saúde, não coincidindo totalmente com as definições internacionais expressas neste estudo.
Resumo:
Whereas child care quality has been extensively studied in the U.S., there is much less information about the quality of child care in other countries.With one of the highest maternal employment rates in Europe, it is important to examine child care in Portugal. Thirty toddler classrooms in child care centers were observed. The purpose of this studywas to determine whether structural features account for overall toddler child care quality. Results showed younger and better-paid teachers provided better toddler child care quality. Space available per childwas not a statistically significant predictor of toddler child care quality.Overall quality results suggest some issues to be addressed by early education policy makers and indicate the need to promote quality in Portuguese toddler child care programs.
Resumo:
Evidence indicates that exposure to high levels of noise adversely affects human health, and these effects are dependent upon various factors. In hospitals, there are many sources of noise, and high levels exert an impact on patients and staff, increasing both recovery time and stress, respectively. The goal of this pilot study was to develop, implement and evaluate the effectiveness of a training program (TP) on noise reduction in a Neonatal Intensive Care Units (NICU) by comparing the noise levels before and after the implementation of the program. A total of 79 health professionals participated in the study. The measurements of sound pressure levels took into account the layout of the unit and location of the main sources of noise. General results indicated that LAeq levels before implementation of the training program were often excessive, ranging from 48.7 ± 2.94 dBA to 71.7 ± 4.74 dBA, exceeding international guidelines. Similarly following implementation of the training program noise levels remained unchanged (54.5 ± 0.49 dBA to 63.9 ± 4.37 dBA), despite a decrease in some locations. There was no significant difference before and after the implementation of TP. However a significant difference was found for Lp, Cpeak, before and after training staff, suggesting greater care by healthcare professionals performing their tasks. Even recognizing that a TP is quite important to change behaviors, this needs to be considered in a broader context to effectively control noise in the NICU.
Resumo:
1st ASPIC International Congress
Resumo:
This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.
Resumo:
A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.