4 resultados para correlation coefficients

em Instituto Politécnico do Porto, Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A promoção de competências de leitura é um tema central, tanto na educação regular, como na educação especial em crianças em idade pré-escolar e escolar. Todavia, as competências de leitura de indivíduos adultos com incapacidade intelectual são um domínio muito pouco estudado. São também escassos os estudos direcionados à avaliação dessas competências. Esta investigação propõe uma tradução/ adaptação do APAR (Assessment of Phonological Awareness and Reading), um protocolo de avaliação da consciência fonológica (CF) e da leitura especificamente concebido para a população em estudo. Procura-se também analisar os processos cognitivos envolvidos na leitura nos quais a intervenção produzirá resultados mais significativos e confirmar uma relação positiva entre a avaliação prévia de competências escolares em contexto formativo profissional e o efetivo desenvolvimento de competências de leitura. Foram avaliadas em dois momentos (pré e pós-teste) a CF e competências de leitura de 12 adultos com incapacidade intelectual ligeira, sendo estes sujeitos a um programa de intervenção, visando áreas menos desenvolvidas das suas competências que possibilitassem desempenhos de leitura mais fortes. Ao nível da análise quantitativa, foram comparados os resultados obtidos nos dois momentos de administração. No tratamento estatístico recorreu-se a análises de correlação de Spearman para determinar a presença de indicadores de desempenho ao nível da CF e ao cálculo de coeficientes de correlação de Pearson e Spearman para controlar variáveis externas como idade, sexo e habilitações literárias. Os resultados obtidos revelam desempenhos fracos ao nível da leitura/ compreensão textual e, em particular, da CF em pré-teste e ganhos significativos globais após implementação de uma intervenção baseada em medidas de avaliação prévia de competências de leitura/compreensão e CF

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Carbamate compounds are an important group of cholinesterase inhibitors. There is a need for creating awareness regarding the risks of the inadequate carbamate use in the residential areas due to potential adverse human effects. Carbaryl is a commonly used pesticide worldwide. A simple, fast, and high throughput method was developed employing liquid chromatography with fluorescence detector to determine carbaryl residues in rat feces. The extraction was performed by using a rapid, easy, cheap, effective, reliable, and safe (QuEChERS) method, using acetonitrile as the extracting solvent. The parameters for the performance of the extraction method were optimized, such as ratio of mass of sample per volume of extraction solvent, QuEChERS content, and cleanup columns. Linear response was obtained for all calibration curves (solven and matrix-matched) over the established concentration range (5 500 mg/L) with a correlation coefficients higher than 0.999. The achieved recovery was 97.9% with relative standard deviation values of 1.1% (n D 4) at 167 mg/kg fortified concentration level and the limits of detection and quantification were 27.7 and 92.3 mg/kg respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to obtain, for Newtonian and non-Newtonian fluids, heat transfer coefficients, at constant wall temperature as boundary condition, in fully developed laminar flow inside a helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w) and the non-Newtonian fluids aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations 0.1%, 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations 0.1% and 0.2% (w/w). According to the rheological study performed, the polymer solutions had shear thinning behavior and different values of elasticity. The helical coil used has internal diameter, curvature ratio, length and pitch, respectively: 0.004575 m, 0.0263, 5.0 m and 11.34 mm. The Nusselt numbers for the CMC solutions are, on average, slightly higher than those for Newtonian fluids, for identical Prandtl and generalized Dean numbers. As outcome, the viscous component of the shear thinning polymer tends to potentiate the mixing effect of the Dean cells. The Nusselt numbers of the XG solutions are significant lower than those of the Newtonian solutions, for identical Prandtl and generalized Dean numbers. Therefore, the elastic component of the polymer tends to diminish the mixing effect of the Dean cells. A global correlation, for Nusselt number as a function of Péclet, generalized Dean and Weissenberg numbers for all Newtonian and non-Newtonian solutions studied, is presented.