9 resultados para contact dependence

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01×10−7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we show a set of growth conditions, for the two step process, with which the growth of CZTSe is successful and reproducible. The properties of the best CTZSe thin films grown by this method were examined by SEM/EDS, XRD, Raman scattering, AFM/EFM, transmittance and reflectance measurements, photoluminescence (PL) measurements and hot point probe. A broad emission band was observed in the photoluminescence spectrum of the CZTSe thin film. The band gap energy was estimated to be around 1.05 eV at room temperature, using the transmittance and reflectance data, and CZTSe samples show p-type conductivity with the hot point probe. The different characterization techniques show that we could grow single phase CZTSe thin films with our optimized process conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three different lubricating greases and their bleed and base oils were compared in terms of film thickness in a ball-on-disc test rig through optical interferometry. The theoretical values calculated according to Hamrock's equation are in close agreement with the base oil film thickness measurements, which validates the selected experimental methodology. The grease and bleed oil film thickness under fully flooded lubrication conditions presented quite similar behaviour and levels. Therefore, the grease film thickness under full film conditions might be predicted using their bleed oil properties, namely the viscosity and pressure-viscosity coefficient. The base and bleed oil lubricant parameter LP are proportional to the measured film thickness. A relationship between grease and the corresponding bleed oil film thickness was evidenced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article aims to contribute to the discussion of long-term dependence, focusing on the behavior of the main Belgian stock index. Non-parametric analyzes of the general characteristics of temporal frequency show that daily returns are non-ergodic and non-stationary. Therefore, we use the rescaled-range analysis (R/S) and the detrended fluctuation analysis (DFA), under the fractional Brownian motion approach, and we found slight evidence of long-term dependence. These results refute the random walk hypothesis with i.i.d. increments, which is the basis of the EMH in its weak form, and call into question some theoretical modeling of asset pricing. Other more localized complementary study, to identify the evolution of the degree of dependence over time windows, showed that the index has become less persistent from 2010. This may mean a maturing market by the extension of the effects of current financial crisis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 × 10−5 to 1.0 × 10−2 mol/L (10.0 to 2500 µg/mL), and the limit of detection was 1.2 × 10−5 mol/L (3.0 µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01 × 10− 7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.