12 resultados para conservação ex situ
em Instituto Politécnico do Porto, Portugal
Resumo:
The main objective of this research is to exploit the possibility of using an ex situ solvent extraction technique for the remediation of soils contaminated with semi-volatile petroleum hydrocarbons. The composition of the organic phase was chosen in order to form a single phase mixture with an aqueous phase and simultaneously not being disturbed (forming stable emulsions) by the soil particles hauling the contaminants. It should also permit a regeneration of the organic solvent phase. As first, we studied the miscibility domain of the chosen ternary systems constituted by ethyl acetate–acetone–water. This system proved to satisfy the previous requirements allowing for the formation of a single liquid phase mixture within a large spectrum of compositions, and also allowing for an intimate contact with the soil. Contaminants in the diesel range within different functional groups were selected: xylene, naphthalene and hexadecane. The analytical control was done by gas chromatography with FID detector. The kinetics of the extractions proved to be fast, leading to equilibrium after 10 min. The effect of the solid–liquid ratio on the extraction efficiency was studied. Lower S/L ratios (1:8, w/v) proved to be more efficient, reaching recoveries in the order of 95%. The option of extraction in multiple contacts did not improve the recovery in relation to a single contact. The solvent can be regenerated by distillation with a loss around 10%. The contaminants are not evaporated and they remain in the non-volatile phase. The global results show that the ex situ solvent extraction is technically a feasible option for the remediation of semi-volatile aromatic, polyaromatic and linear hydrocarbons.
Resumo:
Tese de Douturamento
Resumo:
Avaliação do estado do gene Epidermal Growth Factor Receptor (EGFR), por Silver In Situ Hibridization (SISH), tem-se destacado como biomarcador preditivo na resposta à terapêutica. O principal objectivo foi optimizar a etapa de recuperação por calor da metodologia automatizada SISH Dual-Colour, em carcinomas pulmonares fixados em formol durante 24 e 72 horas. A optimização levou a um aumento da preservação do contorno nuclear e da intensidade e contraste dos sinais para os dois tempos de fixação, permitindo avaliar o estado do EGFR em 83,3% dos casos em estudo. A SISH Dual-Colour é uma alternativa para avaliar o estado do EGFR.
Resumo:
Apesar da enorme evolução tecnológica, os prazos na construção são cada vez mais reduzidos e os custos mais controlados, verificando-se uma despreocupação no que diz respeito a aspetos como a qualidade e durabilidade da construção das estruturas. Desperta assim nos técnicos, donos-de-obra, entidades executantes e projetistas a necessidade de avaliar o estado de conservação das estruturas de betão armado. Esta dissertação tem como objetivo principal abordar as anomalias e os mecanismos de deterioração mais correntes, os métodos de ensaio destrutivos ou parcialmente destrutivos mais utilizados e adequados, e abordar algumas das técnicas de reparação e reforço das estruturas de betão armado. Os principais danos apresentados nas estruturas são devidos a agentes físicos, mecânicos, biológicos e químicos. Podem ser devidos a causas diretas (acidentais ou naturais), que acarretam uma ação concreta sobre os elementos estruturais, e causas indiretas (humanas), diretamente ligadas com erros de projeto. É primordial fazer-se o levantamento de todas as anomalias existentes para se recorrer a um método de inspeção e ensaio. Consoante a necessidade de informação e estado da estrutura são selecionados os ensaios a realizar, podendo ser realizados “in situ” ou em laboratório. As técnicas de reparação e reforço são vistas como métodos para melhorar as condições da estrutura ao nível da segurança, desempenho, habitabilidade e durabilidade, prevenindo a evolução dos mecanismos de deterioração.
Resumo:
O ingresso no mercado de trabalho e primeiro contacto com a realidade na construção em Portugal motivaram a realização deste relatório. O qual tem como base o estágio realizado na Sika® Portugal Produtos da Construção e Indústria, S.A. como elemento do Departamento Técnico. O trabalho desenvolvido incide sobre a escolha de soluções de reabilitação e na avaliação preliminar do estado de conservação dos edifícios outrora reabilitados com soluções Sika®. A primeira parte deste relatório descreve a adaptação do método de avaliação do estado de conservação de edifícios (MAEC) de forma a realizar esta avaliação apenas no sistema construtivo que compõe a fachada, aplicado num estudo desenvolvido para 100 obras de reabilitação em edifícios distribuídos no território nacional. Numa segunda parte do relatório são apresentados documentos desenvolvidos durante a actividade profissional aquando de visitas às obras e respectivas análises preliminares e especificações técnicas. Nesta segunda parte do relatório mais relacionada com as actividades diárias são ainda apresentados documentos técnicos de apoio a tecnologias e ou selecção de soluções mais adequadas às exigências e necessidades de comportamento dos materiais. É ainda abordado o tema sustentabilidade que actualmente é uma das preocupações nas escolhas e tomadas de decisão de soluções para a reabilitação e construção nova. Apresenta-se ainda um estudo realizado em laboratório que visa determinar o comprimento de amarração de fios ou cordões de pré-esforço colados com resina epoxy a provetes de diferentes tipos de pedra natural.
Resumo:
Naturally occurring radioactive materials (NORM) under certain conditions can reach hazardous radiological levels contributing to an additional exposure dose to ionizing radiation. Most environmental concerns are associated with uranium mining and milling sites, but the same concerns should be addressed to natural near surface occurrences of uranium as well as man-made sources such as technologically enhanced naturally occurring radioactive materials (TENORM) resulting from phosphates industry, ceramic industry and energy production activities, in particular from coal-fired power plants which is one of the major sources of increased exposure to man from enhanced naturally occurring materials. This work describes the methodology developed to assess the environmental radiation by in situ gamma spectrometry in the vicinity of a Portuguese coal fired power plant. The current investigation is part of a research project that is undergoing in the vicinity of Sines Coal-Fired Power Plant (south of Portugal) until the end of 2013.
Resumo:
Mestrado em Engenharia Civil – Ramo Estruturas
Resumo:
Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.
Resumo:
The nomination of Guimarães to host the 2012 European Capital of Culture (ECC) has put on the agenda of the city the need of measuring the effects that the implementation of this mega event could have in it and in the municipality a whole. The balance of the benefits and costs and an extended community involvement tend to reduce negative impacts and enhance positive ones. This chapter analyzes the involvement of population and local associations in the planning and organization of the 2012 Guimarães European Capital of Culture, using the coverage made during 2011 by local and national press of the mega event. A content analysis of the news published covering the period between January and December 2011 and using three newspapers was conducted. From those, two were local and weekly newspapers and one was a national daily one. Looking to data results, it can be concluded that it was poor the community involvement and, also, the one of the cultural associations in the organizations of the 2012 ECC. A strong negative reaction to the model choose to plan the mega event conducted by official organizers was found, which has cast doubts on the desirable participation of the residents and, consequently, on the success of the mega event, especially in a perspective of a medium and long term effects.
Resumo:
O presente trabalho pretende mostrar que a aplicação de medidas de conservação de energia (MCE) pode representar uma redução da intensidade de utilização de matérias-primas na construção de um edifício. Mais concretamente, pode representar uma redução da utilização de materiais e equipamentos, e como consequência, uma redução no esforço económico ao primeiro investimento. Podendo posteriormente representar uma redução na utilização de energia durante o período de funcionamento do edifício. A aplicação de MCE no sector da construção tem vindo a ser uma prática corrente nos novos edifícios e edifícios sujeitos a grandes intervenções de reabilitação. Esta prática deve-se à obrigatoriedade de cumprimento de requisitos regulamentares aplicados à otimização do desempenho energético dos edifícios e dos seus sistemas técnicos, nomeadamente, o RCCTE e o RSECE, entretanto revogados pelo REH e pelo RECS, respetivamente. A implementação de MCE apresenta, na maioria dos casos, benefícios económicos para o promotor do edifício, uma vez que se traduz muitas vezes, na otimização do dimensionamento dos sistemas de Aquecimento, Ventilação e Ar Condicionado (AVAC). Esta otimização permite reduzir os custos associados ao primeiro investimento, bem como na utilização de energia por parte do utilizador, logo na redução dos custos de exploração. No entanto, a falta de quantificação dos impactos do dimensionamento dos sistemas AVAC, da redução de utilização de energia e da análise do custo-benefício da sua aplicação pode condicionar o interesse na sua implementação. Neste contexto, surge a presente dissertação, por iniciativa do Instituto Soldadura e Qualidade (ISQ), aplicado a um caso prático de um edifício já construído e propriedade daquela empresa. Com este trabalho pretende-se avaliar o contributo efetivo das MCE implementadas na fase de projeto e na fase de construção, quer na otimização da dimensão de sistemas e equipamentos AVAC, por via da redução das necessidades energéticas, quer na redução de utilização de energia, permitindo, de seguida, uma avaliação custo-benefício.Na base do caso de estudo está o ECOTERMOLAB, o edifício acima referido, adquirido pelo ISQ para instalação de um laboratório de formação, investigação e desenvolvimento na área da energia. Após aquisição pelo ISQ, o edifício sofreu várias alterações/beneficiações, entre as quais a implementação de MCE, tais como, a aplicação de isolamento térmico na envolvente opaca (paredes, pavimentos e coberturas), duplicação dos vãos envidraçados simples, conferindo-lhes melhores caraterísticas térmicas, e pela aplicação de proteções solar. Foram ainda adotadas MCE aos sistemas AVAC, designadamente, pela adoção de recuperadores de calor nas Unidades de Tratamento de Ar Novo (UTAN’s) e de variadores de velocidade nas bombas de circulação de água e nos ventiladores de ar das UTAN’s. Pretendia o ISQ concluir se a aplicação de todas as MCE contribuiu de forma efetiva para o dimensionamento de sistemas e equipamentos AVAC de menor capacidade e, consequentemente, numa redução de utilização de energia. Em sequência, pretendia avaliar a viabilidade económica da aplicação de todas as MCE, estimando o sobrecusto inicial e o tempo necessário para o retorno financeiro daquele investimento. Para alcançar os objetivos propostos, procedeu-se à simulação energética dinâmica do ECOTERMOLAB, utilizando o programa EnergyPlus. Primeiro foi simulada uma situação base do edifício, sem quaisquer MCE. Posteriormente foi caraterizada cada uma das situações de aplicação das MCE, com o objetivo de avaliar o respetivo impacto individual na utilização de energia pelos sistemas AVAC. Por último foram assumidas todas as soluções em conjunto para avaliar o impacto final de todas as MCE na utilização de energia dos sistemas AVAC, bem como no seu dimensionamento. Das simulações dinâmicas foram obtidos os valores das necessidades de aquecimento e arrefecimento, de energia utilizada pelos sistemas AVAC e de caudais de água aquecida e arrefecida circulada. Com estes valores foi feita uma estimativa de dimensionamento dos equipamentos e componentes AVAC para as situações da aplicação de todas as MCE no ECOTERMOLAB e a sua ausência. A partir da diferença dos custos de aquisição dos respetivos equipamentos e dos valores de poupança em energia foi realizado o estudo da viabilidade económica da implementação das MCE neste edifício. Este estudo permitiu concluir que a aplicação das MCE no ECOTERMOLAB levou à redução da dimensão na generalidade dos equipamentos e componentes AVAC. Permitiu, ainda, concluir que houve uma diminuição de utilização de energia por parte destes sistemas e equipamentos para o aquecimento e arrefecimento. Conclui-se ainda que o período de retorno (Payback) do sobrecusto inicial, estimado em 37.822€ é de, aproximadamente, onze anos e meio, para um valor atual líquido (VAL) de 8.061€ e à taxa interna de rentabilidade (TIR) de 7,03%.
Resumo:
A conjuntura económica da construção não se encontra numa fase de prosperidade, existindo a necessidade de criar soluções construtivas que permitam a redução de custos dos materiais a nível de obra. As lajes de betão armado, devido à sua grande área de implantação, possuem uma parcela importante no orçamento final de qualquer obra de edifícios correntes. Sabendo das possibilidades de aligeiramento de lajes, torna-se necessária a realização de um estudo pormenorizado e comparativo entre soluções de aligeiramento. O desenvolvimento deste relatório reflete todo o trabalho efetuado durante a realização de um estágio curricular desenvolvido na empresa FercaNorte – Estruturas, Lajes e Cofragens, Lda. e foca-se num dimensionamento e estudo comparativo de soluções de lajes fungiformes aligeiradas, aplicadas a dois casos de estudo e também num dimensionamento e estudo comparativo de soluções de lajes aligeiradas unidirecionais mas apenas aplicadas a um caso de estudo. No primeiro caso de estudo, laje fungiforme com um vão de 6 metros nas duas direções, são dimensionadas e comparadas quatro soluções: laje fungiforme maciça; laje fungiforme aligeirada com blocos elipsoides perdidos dispostos de forma ortogonal e envolvidos totalmente por betão; laje fungiforme aligeirada com blocos elipsoides perdidos dispostos em formato de favo de mel e envolvidos totalmente por betão; e laje fungiforme nervurada com moldes recuperáveis. No segundo caso de estudo, laje fungiforme com um vão de 7,04 metros nas duas direções, são dimensionadas e comparadas cinco soluções: laje fungiforme maciça, laje fungiforme aligeirada com blocos cúbicos perdidos dispostos de forma ortogonal e envolvidos totalmente por betão; laje fungiforme aligeirada, com blocos elipsoides perdidos dispostos de forma ortogonal e envolvidos totalmente por betão; laje fungiforme aligeirada com blocos elipsoides perdidos dispostos em formato de favo de mel e envolvidos totalmente por betão; e laje fungiforme nervurada com moldes recuperáveis. No terceiro caso de estudo, laje unidirecional com um vão de 8 metros apoiada em vigas com vão de 5 metros, são dimensionadas e comparadas três soluções: laje maciça; laje aligeirada com perfis tubulares com secção transversal reta oval; e laje nervurada com moldes recuperáveis. No final é apresentada uma estimativa orçamental para cada solução analisada nos três casos de estudo abordados.