5 resultados para biventricular assist device
em Instituto Politécnico do Porto, Portugal
Resumo:
A large part of power dissipation in a system is generated by I/O devices. Increasingly these devices provide power saving mechanisms, inter alia to enhance battery life. While I/O device scheduling has been studied in the past for realtime systems, the use of energy resources by these scheduling algorithms may be improved. These approaches are crafted considering a very large overhead of device transitions. Technology enhancements have allowed the hardware vendors to reduce the device transition overhead and energy consumption. We propose an intra-task device scheduling algorithm for real time systems that allows to shut-down devices while ensuring system schedulability. Our results show an energy gain of up to 90% when compared to the techniques proposed in the state-of-the-art.
Resumo:
Fault injection is frequently used for the verification and validation of the fault tolerant features of microprocessors. This paper proposes the modification of a common on-chip debugging (OCD) infrastructure to add fault injection capabilities and improve performance. The proposed solution imposes a very low logic overhead and provides a flexible and efficient mechanism for the execution of fault injection campaigns, being applicable to different target system architectures.
Resumo:
A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
A presente dissertação insere-se no âmbito da unidade curricular “ Dissertação” do 2º ano do mestrado em Engenharia Eletrotécnica – Sistemas Elétricos de Energia. Com o aumento crescente do número de consumidores de energia, é cada vez mais imperioso a adoção de medidas de racionalização e gestão dos consumos da energia elétrica. Existem diferentes tipos de dificuldades no planeamento e implementação de novas centrais produtoras de energia renovável, pelo que também por este motivo é cada vez mais importante adoção de medidas de gestão de consumos, quer ao nível dos clientes alimentados em média tensão como de baixa tensão. Desta forma será mais acessível a criação de padrões de eficiência energética elevados em toda a rede de distribuição de energia elétrica. Também a economia é afetada por uma fraca gestão dos consumos por parte dos clientes. Elevados desperdícios energéticos levam a que mais energia tenha que ser produzida, energia essa que contribui ainda mais para a elevada taxa de dependência energética em Portugal, e para o degradar da economia nacional. Coloca-se assim a necessidade de implementar planos e métodos que promovam a eficiência energética e a gestão racional de consumos de energia elétrica. Apresenta-se nesta dissertação várias propostas, algumas na forma de projetos já em execução, que visam sensibilizar o consumidor para a importância da utilização eficiente de energia e, ao mesmo tempo, disponibilizam as ferramentas tecnológicas adequadas para auxiliar a implementação dos métodos propostos. Embora os planos apresentados, sobejamente conhecidos, tenham imensa importância, a implementação nos vários consumidores de sistemas capazes de efetivamente reduzir consumos tem um papel fundamental. Equipamentos de gestão de consumos, que são apresentados nesta dissertação, permitem ao consumidor aceder diretamente ao seu consumo. Podem aceder não apenas ao consumo global da instalação mas também ao consumo específico por equipamento, permitindo perceber onde se verifica a situação mais desfavorável. Funcionalidades de programação de perfis tipo, com limitações de potência em vários períodos horários, bem como possibilidades de controlo remoto com recurso a aplicações para Smartphones permitem a redução de consumos ao nível da rede de distribuição e, desta forma, contribuir para a redução dos desperdícios e da dependência energética em Portugal. No âmbito do trabalho de dissertação é desenvolvida uma metodologia de comercialização de potência, que é apresentada nesta tese. Esta metodologia propõem que o consumidor, em função dos seus consumos, pague apenas a quantidade de potência que efetivamente necessita num certo período de tempo. Assim, o consumidor deixa de pagar uma tarifa mensal fixa associada á sua potência contratada, e passará a pagar um valor correspondente apenas à potência que efetivamente solicitou em todas as horas durante o mês. Nesta metodologia que é apresentada, o consumidor poderá também fazer uma análise do seu diagrama de cargas e simular uma alteração da sua tarifa, tarifa esta que varia entre tarifa simples, bi-horária semanal, bi-horária diária, tri-horária semanal ou tri-horária diária, de forma a perceber em qual destas pagará um menor valor pela mesma energia. De forma a que o consumidor possa perceber se haverá vantagem de uma alteração para uma potência contratada flexível, ou para uma outra tarifa associada á energia, tem ao seu dispor uma ferramenta, que em função dos seus consumos, permite retirar conclusões sobre o preço final a pagar na fatura, após cada tipo de alteração. Esta ferramenta foi validada com recurso a várias simulações, para diferentes perfis de consumidores. Desta forma, o utilizador fica a perceber que realmente pode poupar com uma potência contratada flexível, ao mesmo tempo que pode identificar-se com um perfil de simulação e, mais facilmente, perceber para que alteração tarifária pode usufruir de uma maior poupança.