14 resultados para battery storage

em Instituto Politécnico do Porto, Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study, energy production for autonomous underwater vehicles is investigated. This project is part of a bigger project called TURTLE. The autonomous vehicles perform oceanic researches at seabed for which they are intended to be kept operational underwater for several months. In order to ful l a long-term underwater condition, powerful batteries are combined with \micro- scale" energy production on the spot. This work tends to develop a system that generates power up to a maximum of 30 W. Latter energy harvesting structure consists basically of a turbine combined with a generator and low-power electronics to adjust the achieved voltage to a required battery charger voltage. Every component is examined separately hence an optimum can be de ned for all, and subsequently also an overall optimum. Di erent design parameters as e.g. number of blades, solidity ratio and cross-section area are compared for di erent turbines, in order to see what is the most feasible type. Further, a generator is chosen by studying how ux distributions might be adjusted to low velocities, and how cogging torque can be excluded by adapted designs. Low-power electronics are con gured in order to convert and stabilize heavily varying three-phase voltages to a constant, recti ed voltage which is usable for battery storage. Clearly, di erent component parameters as maximum power and torque are matched here to increase the overall power generation. Furthermore an overall maximum power is set up for achieving a maximum power ow at load side. Due to among others typical low velocities of about 0.1 to 0.5 m/s, and constructing limits of the prototype, the vast range of components is restricted to only a few that could be used. Hence, a helical turbine is combined in a direct drive mode to a coreless-stator axial- ux permanent-magnet generator, from which the output voltage is adjusted subsequently by a recti er, impedance matching unit, upconverter circuit and an overall control unit to regulate di erent component parameters. All these electronics are combined in a closed-loop design to involve positive feedback signals. Furthermore a theoretical con guration for the TURTLE vehicle is described in this work and a solution is proposed that might be implemented, for which several design tests are performable in a future study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the energy management of the isolated operation of small power system, the economic scheduling of the generation units is a crucial problem. Applying right timing can maximize the performance of the supply. The optimal operation of a wind turbine, a solar unit, a fuel cell and a storage battery is searched by a mixed-integer linear programming implemented in General Algebraic Modeling Systems (GAMS). A Virtual Power Producer (VPP) can optimal operate the generation units, assured the good functioning of equipment, including the maintenance, operation cost and the generation measurement and control. A central control at system allows a VPP to manage the optimal generation and their load control. The application of methodology to a real case study in Budapest Tech, demonstrates the effectiveness of this method to solve the optimal isolated dispatch of the DC micro-grid renewable energy park. The problem has been converged in 0.09 s and 30 iterations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a microwave-assisted extraction (MAE) methodology was compared with several conventional extraction methods (Soxhlet, Bligh & Dyer, modified Bligh & Dyer, Folch, modified Folch, Hara & Radin, Roese-Gottlieb) for quantification of total lipid content of three fish species: horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), and sardine (Sardina pilchardus). The influence of species, extraction method and frozen storage time (varying from fresh to 9 months of freezing) on total lipid content was analysed in detail. The efficiencies of methods MAE, Bligh & Dyer, Folch, modified Folch and Hara & Radin were the highest and although they were not statistically different, differences existed in terms of variability, with MAE showing the highest repeatability (CV = 0.034). Roese-Gottlieb, Soxhlet, and modified Bligh & Dyer methods were very poor in terms of efficiency as well as repeatability (CV between 0.13 and 0.18).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This technical report describes the work carried out in a project within the ERASMUS programme. The objective of this project was the Integration of an Automatic Warehouse in a Discrete-Part Automation System. The discrete-part automation system located at the LASCRI (Critical Systems) laboratory at ISEP was extended with automatic storage and retrieval of the manufacturing parts, through the integration of an automatic warehouse and an automatic guided vehicle (AGV).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O armazenamento de energia pode ser efetuado sobre cinco categorias, designadamente, elétrica, eletromecânica, mecânica, térmica e química. Contudo, o assunto aqui debatido é sobre meios de armazenamento de energia elétrica, sendo que o armazenamento de eletricidade é usualmente efetuado recorrendo a outros géneros de energia, tais como, química, mecânica, térmica ou, até, em energia potencial. [1]. Há nos dias de hoje uma crescente preocupação na forma como é gerido o setor elétrico, uma vez que este implica um elevado impacto ambiental. Neste sentido tem havido algumas alterações, nomeadamente, no que diz respeito à produção de energia elétrica. A utilização de energias renováveis estão cada vez mais presentes na produção de eletricidade (Figura 1), pois permitem diminuir de forma indireta a utilização dos combustíveis fósseis, sendo esta a principal vantagem face às centrais de produção convencionais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The economical and environment impacts of fossil energies increased the interest for hybrid, battery and fuel-cell electric vehicles. Several demanding engineering challenges must be faced, motivated by different physical domains integration. This paper aims to present an overview on hybrid (HEV) and electric vehicles (EV) basic structures and features. In addition, it will try to point out some of the most relevant challenges to overcome for HEV and EV may be a solid option for the mobility issue. New developments in energy storage devices and energy management systems (EMS) are crucial to achieve this goal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com a crescente integração de energias renováveis variáveis nos sistemas elétricos de energia surgem novos desafios à maneira como se efetua a exploração dos mesmos, devido à dificuldade na previsão produção e na controlabilidade destas energias. Estes desafios são ainda maiores quando se analisa uma rede elétrica isolada de pequenas dimensões sem possibilidade de ser interligada a uma rede continental, por apresentar uma maior fragilidade e dai resultarem critérios de exploração muito mais apertados, de forma a garantir da melhor forma a segurança e estabilidade da rede. Consequentemente existe a necessidade de serem adotadas medidas que atenuem os impactos da variabilidade e tornem mais previsíveis as energias renováveis. É neste âmbito que surgem as tecnologias de armazenamento de energia elétrica. O presente documento apresenta um estudo aprofundado ao sistema eletroprodutor da ilha da Madeira e às suas especificidades, analisando a viabilidade técnica da introdução de baterias em larga escala no sistema. De forma a realizar esta análise, criou-se uma ferramenta de simulação em Matlab, que visou quantificar o impacto da introdução de baterias, quer ao nível da integração de energia eólica, quer ao nível da redução da produção térmica. Esta ferramenta permite ainda uma análise gráfica do diagrama de produção agregado diário, assim como a evolução de potência e energia na bateria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the introduction of the electrics cars into the market new technologies regarding the battery are being developed and new problems to be solved, one of them the battery management system because each type of cell requires a specific way of handling. This research is done using the active research method to find out the actual problem on this subject and features a BMS should have, understand how they work and how to develop them applied to the purpose on this work. Once the features the BMS should have are clarified, it’s possible to develop a BMS for an electric racing car. The decisions are made taking into consideration the nature of the vehicle being developed. After the project done it’s clear to see that what was developed was not only the BMS itself but all the other factors around it, such as CAN communication, safety control, diagnostics and so on.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accumulation of microcystin-LR (MC-LR) in edible aquatic organisms, particularly in bivalves, is widely documented. In this study, the effects of food storage and processing conditions on the free MC-LR concentration in clams (Corbicula fluminea) fed MC-LR-producing Microcystisaeruginosa (1 × 105 cell/mL) for four days, and the bioaccessibility of MC-LR after in vitro proteolytic digestion were investigated. The concentration of free MC-LR in clams decreased sequentially over the time with unrefrigerated and refrigerated storage and increased with freezing storage. Overall, cooking for short periods of time resulted in a significantly higher concentration (P < 0.05) of free MC-LR in clams, specifically microwave (MW) radiation treatment for 0.5 (57.5%) and 1 min (59%) and boiling treatment for 5 (163.4%) and 15 min (213.4%). The bioaccessibility of MC-LR after proteolytic digestion was reduced to 83%, potentially because of MC-LR degradation by pancreatic enzymes. Our results suggest that risk assessment based on direct comparison between MC-LR concentrations determined in raw food products and the tolerable daily intake (TDI) value set for the MC-LR might not be representative of true human exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente tese descreve diferentes soluções que permitem a reutilização da energia recuperada em ascensores eléctricos de roda de aderência dotados de conversores electrónicos de frequência e dessa forma contribuir para a melhoria da eficiência energética nos ascensores. Nos ascensores, a energia potencial é constantemente transferida enquanto a cabina está em movimento. Se a cabina se estiver a movimentar em sentido descendente com plena carga, ou em sentido ascendente, mas vazia, o motor estará em modo gerador. Quando a cabina se movimenta em sentido descendente, e o peso na cabina é superior ao peso do contrapeso, então o binário do motor encontra-se em sentido contrário à velocidade, isto é, o motor está a travar, havendo lugar à recuperação de energia. Igualmente, se a cabina subir vazia, também se poderá recuperar energia eléctrica. A energia acumulada em forma de energia potencial nas pessoas e no contrapeso pode ser recuperada, dado que o motor estará a funcionar como um gerador. De modo a estudar a viabilidade técnica e económica das diferentes soluções foram realizadas medições a uma amostra representativa de ascensores eléctricos de roda de aderência. Esta amostra é constituída por 39 ascensores que estão instalados em diferentes tipos de edifícios e que pertencem a diferentes categorias de utilização, de acordo com a norma VDI 4707:2009. Para cada ascensor foi medida a energia consumida e a energia gerada para uma manobra completa – a descida e a subida da cabina sem carga. A partir das medições, e com base na norma VDI 4707:2009 foram calculados os valores anualizados de energia eléctrica consumidos e produzidos por cada ascensor. A partir das 5 hipóteses identificadas para a utilização da energia recuperada (carregamento de bateria para alimentação dos circuitos em stand-by; carregamento de supercondensador para alimentação dos circuitos em stand-by; carregamento de supercondensador para alimentar o barramento DC; reinjecção da energia no barramento DC de um conjunto de ascensores em grupo; reinjecção da energia na rede eléctrica do edifício onde o ascensor está instalado) foi realizada a avaliação técnica e a avaliação económico-financeira para cada um dos ascensores. Por último, foi desenvolvido um simulador que permite definir a solução de recuperação de energia que seja técnica e economicamente mais viável, para um dado ascensor eléctrico de roda de aderência instalado, mediante a introdução dos parâmetros técnicos do ascensor em avaliação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In-network storage of data in wireless sensor networks contributes to reduce the communications inside the network and to favor data aggregation. In this paper, we consider the use of n out of m codes and data dispersal in combination to in-network storage. In particular, we provide an abstract model of in-network storage to show how n out of m codes can be used, and we discuss how this can be achieved in five cases of study. We also define a model aimed at evaluating the probability of correct data encoding and decoding, we exploit this model and simulations to show how, in the cases of study, the parameters of the n out of m codes and the network should be configured in order to achieve correct data coding and decoding with high probability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Demo in Workshop on ns-3 (WNS3 2015). 13 to 14, May, 2015. Castelldefels, Spain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

De forma a não comprometer o conforto ou a qualidade de vida, nos dias de hoje, é obrigatório que a energia elétrica esteja presente. Sendo indispensável, torna-se necessário assegurar que a sua distribuição seja feita da forma mais qualitativa possível. Uma resposta rápida e eficaz a possíveis falhas que ocorram na rede, irá garantir a tal qualidade de serviço desejada. Para isso, a automatização dos processos é uma grande evolução e objetivo de concretização do setor elétrico. Neste contexto surge o conceito de Smart Grid, que tem como principal objetivo a combinação entre o setor elétrico e a evolução da tecnologia. A par desta característica, estes tipos de redes vêm também trazer evoluções no âmbito ambiental, pois a produção de energia elétrica é feita, maioritariamente, por fontes de energia renovável. Este projeto incide na análise das vantagens técnicas e económicas da inclusão de equipamentos que detêm capacidades de armazenamento de energia, as Baterias de Armazenamento de Energia (BAE), neste tipo de redes. Para tal, procedeu-se à utilização do método do Despacho Económico, que tem como principal objetivo a determinação dos níveis de produção de todas as unidades geradoras do sistema, satisfazendo a carga, ao mais baixo custo de produção. Com este método, foram criados vários cenários de estudo com vista a validar todo o propósito deste projeto. Nesta dissertação, é também realizado um estudo de viabilidade económica destes equipamentos de armazenamento de energia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integration of wind power in eletricity generation brings new challenges to unit commitment due to the random nature of wind speed. For this particular optimisation problem, wind uncertainty has been handled in practice by means of conservative stochastic scenario-based optimisation models, or through additional operating reserve settings. However, generation companies may have different attitudes towards operating costs, load curtailment, or waste of wind energy, when considering the risk caused by wind power variability. Therefore, alternative and possibly more adequate approaches should be explored. This work is divided in two main parts. Firstly we survey the main formulations presented in the literature for the integration of wind power in the unit commitment problem (UCP) and present an alternative model for the wind-thermal unit commitment. We make use of the utility theory concepts to develop a multi-criteria stochastic model. The objectives considered are the minimisation of costs, load curtailment and waste of wind energy. Those are represented by individual utility functions and aggregated in a single additive utility function. This last function is adequately linearised leading to a mixed-integer linear program (MILP) model that can be tackled by general-purpose solvers in order to find the most preferred solution. In the second part we discuss the integration of pumped-storage hydro (PSH) units in the UCP with large wind penetration. Those units can provide extra flexibility by using wind energy to pump and store water in the form of potential energy that can be generated after during peak load periods. PSH units are added to the first model, yielding a MILP model with wind-hydro-thermal coordination. Results showed that the proposed methodology is able to reflect the risk profiles of decision makers for both models. By including PSH units, the results are significantly improved.