6 resultados para analytical approach

em Instituto Politécnico do Porto, Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hand-off (or hand-over), the process where mobile nodes select the best access point available to transfer data, has been well studied in wireless networks. The performance of a hand-off process depends on the specific characteristics of the wireless links. In the case of low-power wireless networks, hand-off decisions must be carefully taken by considering the unique properties of inexpensive low-power radios. This paper addresses the design, implementation and evaluation of smart-HOP, a hand-off mechanism tailored for low-power wireless networks. This work has three main contributions. First, it formulates the hard hand-off process for low-power networks (such as typical wireless sensor networks - WSNs) with a probabilistic model, to investigate the impact of the most relevant channel parameters through an analytical approach. Second, it confirms the probabilistic model through simulation and further elaborates on the impact of several hand-off parameters. Third, it fine-tunes the most relevant hand-off parameters via an extended set of experiments, in a realistic experimental scenario. The evaluation shows that smart-HOP performs well in the transitional region while achieving more than 98 percent relative delivery ratio and hand-off delays in the order of a few tens of a milliseconds.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Uma nova área tecnológica está em crescente desenvolvimento. Esta área, denominada de internet das coisas, surge na necessidade de interligar vários objetos para uma melhoria a nível de serviços ou necessidades por parte dos utilizadores. Esta dissertação concentra-se numa área específica da tecnologia internet das coisas que é a sensorização. Esta rede de sensorização é implementada pelo projeto europeu denominado de Future Cities [1] onde se cria uma infraestrutura de investigação e validação de projetos e serviços inteligentes na cidade do Porto. O trabalho realizado nesta dissertação insere-se numa das plataformas existentes nessa rede de sensorização: a plataforma de sensores ambientais intitulada de UrbanSense. Estes sensores ambientais que estão incorporados em Data Collect Unit (DCU), também denominados por nós, medem variáveis ambientais tais como a temperatura, humidade, ozono e monóxido de carbono. No entanto, os nós têm recursos limitados em termos de energia, processamento e memória. Apesar das grandes evoluções a nível de armazenamento e de processamento, a nível energético, nomeadamente nas baterias, não existe ainda uma evolução tão notável, limitando a sua operacionalidade [2]. Esta tese foca-se, essencialmente, na melhoria do desempenho energético da rede de sensores UrbanSense. A principal contribuição é uma adaptação do protocolo de redes Ad Hoc OLSR (Optimized Link State Routing Protocol) para ser usado por nós alimentados a energia renovável, de forma a aumentar a vida útil dos nós da rede de sensorização. Com esta contribuição é possível obter um maior número de dados durante períodos de tempo mais longos, aproximadamente 10 horas relativamente às 7 horas anteriores, resultando numa maior recolha e envio dos mesmos com uma taxa superior, cerca de 500 KB/s. Existindo deste modo uma aproximação analítica dos vários parâmetros existentes na rede de sensorização. Contudo, o aumento do tempo de vida útil dos nós sensores com recurso à energia renovável, nomeadamente, energia solar, incrementa o seu peso e tamanho que limita a sua mobilidade. Com o referido acréscimo a determinar e a limitar a sua mobilidade exigindo, por isso, um planeamento prévio da sua localização. Numa primeira fase do trabalho analisou-se o consumo da DCU, visto serem estes a base na infraestrutura e comunicando entre si por WiFi ou 3G. Após uma análise dos protocolos de routing com iv suporte para parametrização energética, a escolha recaiu sobre o protocolo OLSR devido à maturidade e compatibilidade com o sistema atual da DCU, pois apesar de existirem outros protocolos, a implementação dos mesmos, não se encontram disponível como software aberto. Para a validação do trabalho realizado na presente dissertação, é realizado um ensaio prévio sem a energia renovável, para permitir caracterização de limitações do sistema. Com este ensaio, tornou-se possível verificar a compatibilidade entre os vários materiais e ajustamento de estratégias. Num segundo teste de validação é concretizado um ensaio real do sistema com 4 nós a comunicar, usando o protocolo com eficiência energética. O protocolo é avaliado em termos de aumento do tempo de vida útil do nó e da taxa de transferência. O desenvolvimento da análise e da adaptação do protocolo de rede Ad Hoc oferece uma maior longevidade em termos de tempo de vida útil, comparando ao que existe durante o processamento de envio de dados. Apesar do tempo de longevidade ser inferior, quando o parâmetro energético se encontra por omissão com o fator 3, a realização da adaptação do sistema conforme a energia, oferece uma taxa de transferência maior num período mais longo. Este é um fator favorável para a abertura de novos serviços de envio de dados em tempo real ou envio de ficheiros com um tamanho mais elevado.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for column design for any type of packing and contaminant which avoids the necessity of an arbitrary chosen diameter. It also avoids the employment of the usual graphical Eckert correlations for pressure drop. The hydraulic features are previously chosen as a project criterion. The design procedure was translated into a convenient algorithm in C++ language. A column was built in order to test the design, the theoretical steady-state and dynamic behaviour. The experiments were conducted using a solution of chloroform in distilled water. The results allowed for a correction in the theoretical global mass transfer coefficient previously estimated by the Onda correlations, which depend on several parameters that are not easy to control in experiments. For best describe the column behaviour in stationary and dynamic conditions, an original mathematical model was developed. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting ODE can be solved by analytical methods, and in dynamic state the discretization of the PDE by finite differences allows for the overcoming of this difficulty. To estimate the contaminant concentrations in both phases in the column, a numerical algorithm was used. The high number of resulting algebraic equations and the impossibility of generating a recursive procedure did not allow the construction of a generalized programme. But an iterative procedure developed in an electronic worksheet allowed for the simulation. The solution is stable only for similar discretizations values. If different values for time/space discretization parameters are used, the solution easily becomes unstable. The system dynamic behaviour was simulated for the common liquid phase perturbations: step, impulse, rectangular pulse and sinusoidal. The final results do not configure strange or non-predictable behaviours.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fractal geometry is used to model of a naturally fractured reservoir and the concept of fractional derivative is applied to the diffusion equation to incorporate the history of fluid flow in naturally fractured reservoirs. The resulting fractally fractional diffusion (FFD) equation is solved analytically in the Laplace space for three outer boundary conditions. The analytical solutions are used to analyze the response of a naturally fractured reservoir considering the anomalous behavior of oil production. Several synthetic examples are provided to illustrate the methodology proposed in this work and to explain the diffusion process in fractally fractured systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A voltammetric biosensor for Ara h 6 (a peanut allergen) detection in food samples was developed. Gold nanoparticle-modified screen-printed carbon electrodes were used to develop a sandwich-type immunoassay using two-monoclonal antibodies. The antibody-antigen interaction was detected through the electrochemical detection of enzymatically deposited silver. The immunosensor presented a linear range between 1 and 100 ng/ml, as well as high precision (inter-day RSD ≤9.8 %) and accuracy (recoveries ≥96.7 %). The detection and quantification limits were 0.27 and 0.88 ng/ml, respectively. It was possible to detect small levels of Ara h 6 in complex food matrices.