4 resultados para Welland Canal (Ont.) -- Rates and tolls

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coal contains trace quantities of natural radionuclides such as Th-232, U-235, U-238, as well as their radioactive decay products and 40K. These radionuclides can be released as fly ash in atmospheric emissions from coal-fired power plants, dispersed into the environment and deposited on the surrounding top soils. Therefore, the natural radiation background level is enhanced and consequently increase the total dose for the nearby population. A radiation monitoring programme was used to assess the external dose contribution to the natural radiation background, potentially resulting from the dispersion of coal ash in past atmospheric emissions. Radiation measurements were carried out by gamma spectrometry in the vicinity of a Portuguese coal-fired power plant. The radiation monitoring was achieved both on and off site, being the boundary delimited by a 20 km circle centered in the stacks of the coal plant. The measured radionuclides concentrations for the uranium and thorium series ranged from 7.7 to 41.3 Bq/kg for Ra-226 and from 4.7 to 71.6 Bq/kg for Th-232, while K-40 concentrations ranged from 62.3 to 795.1 Bq/kg. The highest values were registered near the power plant and at distances between 6 and 20 km from the stacks, mainly in the prevailing wind direction. The absorbed dose rates were calculated for each sampling location: 13.97-84.00 ηGy/h, while measurements from previous studies carried out in 1993 registered values in the range of 16.6-77.6 ηGy/h. The highest values were registered at locations in the prevailing wind direction (NW-SE). This study has been primarily done to assess the radiation dose rates and exposure to the nearby population in the surroundings of a coal-fired power plant. The results suggest an enhancement or at least an influence in the background radiation due to the coal plant past activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proteins secreted to the extracellular environment or to the periphery of the cell envelope, the secretome, play essential roles in foraging, antagonistic and mutualistic interactions. We hypothesize that arms races, genetic conflicts and varying selective pressures should lead to the rapid change of sequences and gene repertoires of the secretome. The analysis of 42 bacterial pan-genomes shows that secreted, and especially extracellular proteins, are predominantly encoded in the accessory genome, i.e. among genes not ubiquitous within the clade. Genes encoding outer membrane proteins might engage more frequently in intra-chromosomal gene conversion because they are more often in multi-genic families. The gene sequences encoding the secretome evolve faster than the rest of the genome and in particular at non-synonymous positions. Cell wall proteins in Firmicutes evolve particularly fast when compared with outer membrane proteins of Proteobacteria. Virulence factors are over-represented in the secretome, notably in outer membrane proteins, but cell localization explains more of the variance in substitution rates and gene repertoires than sequence homology to known virulence factors. Accordingly, the repertoires and sequences of the genes encoding the secretome change fast in the clades of obligatory and facultative pathogens and also in the clades of mutualists and free-living bacteria. Our study shows that cell localization shapes genome evolution. In agreement with our hypothesis, the repertoires and the sequences of genes encoding secreted proteins evolve fast. The particularly rapid change of extracellular proteins suggests that these public goods are key players in bacterial adaptation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A presente tese pretende fazer uma abordagem ao crescimento dos consumos de energia elétrica, que se tem verificado, nos últimos anos, no setor das telecomunicações e das tecnologias de informação; devido ao constante crescimento das redes, dos equipamentos a ela ligados e do tráfego que nelas transita. Num contexto de globalização da economia, no qual, as redes de telecomunicações e de energia elétrica são dois dos maiores contribuintes, a presente tese procura encontrar enquadramentos e soluções para um dos maiores desafios que a humanidade enfrenta atualmente, e que em parte, é consequente dessa globalização: encontrar novas fontes e formas de utilização da energia, -particularmente da energia elétrica - para que a humanidade continue a usufruir, de uma forma sustentável, dos benefícios que a mesma proporciona. Na primeira parte, procura-se fazer uma abordagem que utiliza fontes de informação e conhecimento, do mercado global, nomeadamente, entidades reguladoras e normalizadoras, operadores, fornecedores de tecnologias e consumidores, que abrangessem os três maiores mercados mundiais – União Europeia, Estados Unidos da América e Ásia-Pacífico. Considerou-se fundamental fazê-lo, por se tratar de uma dissertação no âmbito de um Mestrado com o selo de garantia EUR-ACE. Ao longo da dissertação analisou-se a temática da eficiência energética nas redes de telecomunicações e das tecnologias de informação e comunicação, um tema cada vez mais pertinente, já que o número de pessoas com ligações à Internet, já supera os 3 mil milhões, e as redes passaram a ser o meio por onde são transmitidos, a cada segundo, terabytes de sinais de voz, dados e vídeo. Procurou-se encontrar as linhas de orientação que estão a ser traçadas, para otimizar os consumos energéticos, de um complexo sistema convergente de redes e serviços, formado por entidades reguladoras e normalizadoras, operadores, fornecedores de tecnologias e consumidores, onde nem sempre as fronteiras estão perfeitamente definidas. Perante a constatação da realidade exposta, analisou-se as políticas energéticas desenvolvidas nos últimos anos, pelos vários players do mercado das telecomunicações, das tecnologias de informação e dos sistemas elétricos de energia bem como algumas métricas e objetivos comumente aceites. viii São analisados os contributos das partes interessadas, para o desenvolvimento de políticas energéticas eficazes, por forma a permitirem uma implementação, que considere o funcionamento dos equipamentos como um todo, e não de uma forma isolada como tradicionalmente o assunto era abordado. As especificidades na forma como funcionam as redes de telecomunicações e respetivos equipamentos, são expostas sobre várias óticas, comprovando-se que a temática da eficiência energética é uma das áreas mais difíceis lidar, de todas as consideradas nas políticas energéticas. Demonstrou-se que muitos dos equipamentos não estão otimizados em termos de gestão de energia, procurou-se evidenciar as consequências dessa realidade, uma vez que os equipamentos referidos, têm a necessidade de estar permanentemente a ser alimentados pela rede de energia elétrica, para garantir as funções para que foram projetados. Da pesquisa efetuada e descrita ao longo da dissertação, constatamos o empenho de toda a comunidade científica, operadores e agências de energia e de telecomunicações, em resolver o problema, já que há a consciencialização de que o ritmo de crescimento da rede e equipamentos terminais, é superior ao registado na melhoria da eficiência energética dos vários componentes e equipamentos terminais. Na segunda parte do relatório da tese, procurou-se testar a aplicabilidade das normas e recomendações dos organismos que tutelam a atividade a nível global - algumas publicadas nos últimos 2 anos - a um caso prático. Um edifício hospitalar de média dimensão. Foi elaborada uma aplicação informática, que suportada numa metodologia padronizada, seja capaz de fazer a avaliação da eficiência energética dos equipamentos serviços de telecomunicações de informação e comunicação em funcionamento do hospital. Por dificuldades de disponibilidade dos responsáveis do edifício, os resultados ficaram aquém do esperado. Conseguiu-se desenhar a aplicação, inventariar-se apenas parte dos equipamentos. Demonstrou-se que, a forma como alguns equipamentos estão a ser utilizados, não cumprem regras de utilização racional e eficiente. Procurou-se sensibilizar alguns dos responsáveis, para a necessidade de alterar comportamentos e prosseguir o processo de inventariação, por forma, a que o trabalho iniciado atinja os objetivos propostos.