7 resultados para Typical Meteorological Year
em Instituto Politécnico do Porto, Portugal
Resumo:
The present research paper presents five different clustering methods to identify typical load profiles of medium voltage (MV) electricity consumers. These methods are intended to be used in a smart grid environment to extract useful knowledge about customer’s behaviour. The obtained knowledge can be used to support a decision tool, not only for utilities but also for consumers. Load profiles can be used by the utilities to identify the aspects that cause system load peaks and enable the development of specific contracts with their customers. The framework presented throughout the paper consists in several steps, namely the pre-processing data phase, clustering algorithms application and the evaluation of the quality of the partition, which is supported by cluster validity indices. The process ends with the analysis of the discovered knowledge. To validate the proposed framework, a case study with a real database of 208 MV consumers is used.
Resumo:
Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia
Resumo:
A Mundotêxtil foi fundada em 1975 tendo iniciado a sua actividade na área comercial de produtos têxteis. Actualmente é o maior produtor nacional de atoalhados de felpo e emprega 575 colaboradores. Como resultado do seu crescimento e sobretudo da actividade de tingimento de fio e felpo, as necessidades de água são consideráveis e o volume de efluentes gerados nos processos industriais é cada vez maior a empresa avançou com a construção de uma estação de tratamento por lamas activadas, colocando-a em funcionamento em Setembro de 2004. Inicialmente surgiram dificuldades para a remoção da cor e da concentração da Carência Química de Oxigénio (CQO) de modo a cumprir os limites máximos de emissão permitidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98, de 1 de Agosto. Com a descarga de parte dos efluentes no SIDVA e a utilização de um coagulante adicionado ao reactor o tratamento passou a apresentar melhores resultados. O intuito deste trabalho é o de apresentar soluções de modo a optimizar o funcionamento do tratamento biológico da Mundotêxtil. A optimização pode começar na concepção dos produtos, pode incidir no processo de fabrico para além de poder ser efectuada no seio da estação de tratamento biológico. Foi efectuado um estudo do tratamento biológico por lamas activadas no Laboratório de Tecnologia Química Profª Doutora Lída de Vasconcelos, laboratório tecnológico do Instituto Superior de Engenharia do Porto (ISEP) que decorreu nos meses de Maio, Junho e Julho de 2010. O estudo laboratorial foi efectuado para três situações distintas: 1) tratamento do efluente bruto sem qualquer tipo de pré-tratamento (ensaios 1 a 3); 2) tratamento do efluente bruto submetido a pré-tratamento com coagulante Ambifloc BIO MD (ensaios 4 e 5) e 3) tratamento com adição de fungos ao tanque de arejamento (ensaio 6). Foram utilizadas duas instalações de tratamento alimentadas a partir do mesmo tanque de alimentação. Os dois sistemas eram idênticos, diferiram nos caudais de alimentação de efluente que foram alterados ao longo do estudo. O efluente a tratar foi fornecido pela empresa Mundotêxtil, sendo recolhido por diversas vezes ao longo dos ensaios. Este efluente foi retirado após o pré-tratamento da empresa, ou seja este efluente é o mesmo que alimenta o tratamento biológico da Mundotêxtil. Devido a este facto o efluente usado no estudo laboratorial teve uma variabilidade no período em que decorreu o estudo, nomeadamente em termos de concentração de CQO e cor. A relação entre a Carência Bioquímica (CBO5) e a CQO situouse entre 0,47 e 0,63 o que traduz que está dentro dos valores típicos para um efluente têxtil. Os melhores resultados globais de remoção de CQO foram obtidos no ensaio 5 e estiveram compreendidos entre 73,2% e 77,5% para o ensaio 5.1 e entre 62,9 e 73,2% para o ensaio 5.2. Neste ensaio foi utilizado o coagulante. Todos os valores de concentração de CQO obtidos nos efluentes dos decantadores para os ensaios 2, 5 e 6 são inferiores aos valores limite de descarga definidos nas normas de descarga no rio Ave e o Decreto-Lei 236/98. Os valores de concentração de Sólidos Suspensos Totais (SST), pH, fósforo, CBO5 e cor nos decantadores cumpriram os limites de descarga definidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98 em todos os ensaios. Os parâmetros cinéticos obtidos para os ensaios com descorante são os que melhor se ajustam ao projecto de uma instalação de tratamento biológico por lamas activadas do efluente da Mundotêxtil. Os valores obtidos, após ajuste, são os seguintes: k=0,015 L/(mgSSV*d); Sn=12 mg/L; a=0,7982 kgO2/kgCBO5; b=0,0233 [kgO2/(kgSSV*d); y=0,2253 kgSSV/kgCBO5; kd=0,0036 kgSSV/(kgSSV*d. Com base nos parâmetros cinéticos obtiveram-se os seguintes resultados para o projecto de uma estação de tratamento biológico por lamas activadas: · Tempo de retenção hidráulica no reactor de 1,79 d, · Volume do reactor igual a 3643 m3 · Consumo de oxigénio no reactor de 604 kg/d · Razão de recirculação igual a 0,8 · Volume total do decantador secundário igual a 540 m3 · Diâmetro do decantador secundário igual a 15 m A quantidade de oxigénio necessário é baixa e o valor mais adequado deverá ser da ordem de 1200 kg/d. Também foi efectuada uma análise aos produtos químicos consumidos pela empresa na área das tinturarias com a finalidade de identificar as substâncias com uma maior influência potencial no funcionamento da Estação de Tratamento Biológico. O encolante CB, Cera Têxtil P Líquida, Perfemina P-12, Meropan DPE-P, Meropan BRE-P, Indimina STS e Benzym TEC são os produtos químicos que têm uma influência potencial mais significativa na qualidade dos efluentes. Devido ao facto das temperaturas do efluente alimentado ao tratamento biológico da Mundotêxtil oscilarem entre 35 ºC e 43ºC efectuou-se um estudo às necessidades de água quente das tinturarias e por outro lado à capacidade de aquecimento dos efluentes disponíveis. Actualmente a racionalização dos consumos de água é cada vez mais premente, por isso também é apresentado neste trabalho um estudo para a substituição das máquinas convencionais das tinturarias com uma relação de banho 1:10 por máquinas de banho curto (1:6,5). Verifica-se a redução de consumos de 40% de água, 52% de energia eléctrica, 35% de produtos químicos, 51% das necessidades de vapor e por consequência um aumento da produtividade. A empresa pode reduzir os consumos de água em cerca de 280.000 m3/ano. A utilização do pré-tratamento com o coagulante permitirá baixar a concentração da CQO e reduzir a cor à entrada do reactor tratamento biológico. Deste modo é possível manter um tratamento eficiente à saída do tratamento biológico nas situações de descarga de cores carregadas e carga orgânica elevada. Com este conjunto de soluções, quer sejam aplicadas na totalidade ou não, a empresa Mundotêxtil pode enfrentar o futuro com mais confiança podendo estar preparada para fazer face à escassez de água e custos cada vez maiores da energia. Por outro lado pode tratar os seus efluentes a custos menores. A substituição das máquinas de tingimento por máquinas com relação de banho mais baixa (banho curto) implica investimentos elevados mas estes investimentos são necessários não só por motivos ambientais mas também devido à grande competitividade dos mercados.
Resumo:
Global warming and the associated climate changes are being the subject of intensive research due to their major impact on social, economic and health aspects of the human life. Surface temperature time-series characterise Earth as a slow dynamics spatiotemporal system, evidencing long memory behaviour, typical of fractional order systems. Such phenomena are difficult to model and analyse, demanding for alternative approaches. This paper studies the complex correlations between global temperature time-series using the Multidimensional scaling (MDS) approach. MDS provides a graphical representation of the pattern of climatic similarities between regions around the globe. The similarities are quantified through two mathematical indices that correlate the monthly average temperatures observed in meteorological stations, over a given period of time. Furthermore, time dynamics is analysed by performing the MDS analysis over slices sampling the time series. MDS generates maps describing the stations’ locus in the perspective that, if they are perceived to be similar to each other, then they are placed on the map forming clusters. We show that MDS provides an intuitive and useful visual representation of the complex relationships that are present among temperature time-series, which are not perceived on traditional geographic maps. Moreover, MDS avoids sensitivity to the irregular distribution density of the meteorological stations.
Resumo:
The current practices in the consumption metering by electricity utilities is currently largely based on monthly consumption reading. The consumption metering device is always calculating the cumulative consumption. Then, it is possible to calculate the difference between the actual and the previous consumption evaluation in order to estimate the monthly consumption. The power systems planning needs in many aspects to handle consumption data obtained for shorter periods, namely in the Demand Response programs planning. The work presented in this paper is based on the application of typical consumption profiles that are previously defined for a certain power system area. Such profiles are then used in order to estimate the 15 minutes consumption for a certain consumer or consumer type.
Resumo:
Every year forest fires consume large areas, being a major concern in many countries like Australia, United States and Mediterranean Basin European Countries (e.g., Portugal, Spain, Italy and Greece). Understanding patterns of such events, in terms of size and spatiotemporal distributions, may help to take measures beforehand in view of possible hazards and decide strategies of fire prevention, detection and suppression. Traditional statistical tools have been used to study forest fires. Nevertheless, those tools might not be able to capture the main features of fires complex dynamics and to model fire behaviour [1]. Forest fires size-frequency distributions unveil long range correlations and long memory characteristics, which are typical of fractional order systems [2]. Those complex correlations are characterized by self-similarity and absence of characteristic length-scale, meaning that forest fires exhibit power-law (PL) behaviour. Forest fires have also been proved to exhibit time-clustering phenomena, with timescales of the order of few days [3]. In this paper, we study forest fires in the perspective of dynamical systems and fractional calculus (FC). Public domain forest fires catalogues, containing data of events occurred in Portugal, in the period 1980 up to 2011, are considered. The data is analysed in an annual basis, modelling the occurrences as sequences of Dirac impulses. The frequency spectra of such signals are determined using Fourier transforms, and approximated through PL trendlines. The PL parameters are then used to unveil the fractional-order dynamics characteristics of the data. To complement the analysis, correlation indices are used to compare and find possible relationships among the data. It is shown that the used approach can be useful to expose hidden patterns not captured by traditional tools.
Resumo:
Na União Europeia os sectores dos transportes e da indústria são ambos grandes consumidores de energia, mas são os edifícios residenciais e de serviços onde o consumo energético é maior, e em 2005, segundo a EnerBuilding, representavam cerca de 17% dos consumos de energia primária em termos nacionais. A energia gasta com a iluminação, o aquecimento, o arrefecimento e AQS das habitações, locais de trabalho e locais de lazer é superior à consumida pelos sectores dos transportes e da indústria. As habitações representam dois terços do consumo total de energia dos edifícios europeus, o qual aumenta todos os anos com a melhoria da qualidade de vida, traduzindo-se numa maior utilização dos sistemas de climatização. Neste sentido, e de acordo com o decreto-lei que transpõe para a legislação portuguesa a diretiva comunitária relativa ao desempenho energético dos edifícios, todos os Estados da União Europeia devem ter um sistema de certificação energética para informar o cidadão sobre a qualidade térmica dos edifícios, aquando da construção, da venda ou do arrendamento. Assim, entrou em vigor em Portugal, desde 1 de Janeiro de 2009, a obrigatoriedade de apresentação de um certificado de eficiência energética, no ato de compra, venda ou aluguer de edifícios novos e existentes. A certificação energética permite assim aos futuros utilizadores dos edifícios obter informação sobre os potenciais consumos de energia, no caso dos novos edifícios ou no caso de edifícios existentes sujeitos a grandes intervenções de reabilitação, dos seus consumos reais ou aferidos para padrões de utilização típicos, passando o consumo energético a integrar um conjunto dos aspetos importantes para a caracterização de qualquer edifício. Em edifícios de serviços, o certificado energético assegura aos utentes do edifício ou da fração que este reúne condições para garantir a eficiência energética e a adequada qualidade do ar interior. Uma vez que passamos 80% do nosso tempo em edifícios, e que isto se reflete num consumo cada vez mais elevado do sector residencial e dos serviços no consumo total energético do país, este trabalho pretende fazer a comparação dos vários equipamentos de aquecimento, de arrefecimento e de AQS e qual a influência dos mesmos na certificação energética de edifícios, e consequentemente na eficiência dos mesmos, sendo que a eficiência e a certificação energética de um edifício deve ser um aspeto relevante a levar em consideração no momento do planeamento ou da construção, bem como na aquisição de uma nova habitação. Um projeto concebido de modo a tirar proveito das condições climáticas, da orientação solar, dos ventos dominantes e utilizadas técnicas construtivas e os materiais adequados, é possível reduzir os gastos energéticos com a iluminação ou os sistemas de climatização.