3 resultados para Três Lagoas
em Instituto Politécnico do Porto, Portugal
Resumo:
Polissema: Revista de Letras do ISCAP 2002/N.º 2 Linguagens
Resumo:
The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.
Resumo:
As lesões músculo-esqueléticas (LME) são comuns nas atividades desportivas, nomeadamente no futebol. No entanto, apesar da importância dos árbitros nesta modalidade, a maior parte dos estudos tem-se centrado nos jogadores de futebol. Sabe-se no entanto que as entorses são um dos tipos de lesões mais frequentes e que existem um conjunto de fatores de risco que potenciam a sua ocorrência, como o tipo de piso. Este estudo teve como objetivo comparar a influência de três tipos de piso (relvado natural, relvado artificial e terra batida) no risco de entorse lateral ou por inversão em árbitros. Este estudo foi desenvolvido em duas fases. A primeira pretendeu analisar a perceção de risco sobre os diferentes tipos de pisos. Para isso, foi elaborado e aplicado um questionário, envolvendo 157 árbitros. Este analisou questões referentes à caracterização pessoal dos árbitros, atividade de arbitragem e suas percepções sobre o nível de risco de entorse, nível de exigência do tornozelo, nível de esforço, nível e influência das condições meteorológicas e nível de aderência. Na segunda fase foram realizados dois testes práticos para a avaliação do risco de entorse em cada tipo de piso através da análise de dois indicadores: amplitude de variação do movimento de inversão/eversão, e equilíbrio. Foi analisada a amplitude do movimento de inversão/eversão nos três tipos de piso no momento em que o árbitro muda de direção à esquerda, através da realização do “Teste T”. O segundo teste consistiu na aplicação do YBalance Test para a determinação do equilíbrio. Foi determinado o maior alcance possível com o membro inferior dominante em cada uma das três direções permitidas. Os resultados deste estudo indicaram que os árbitros percebem o piso em terra batida como aquele que apresenta maior risco de desenvolvimento de LME e de entorse, maior nível de exigência de rotação do tornozelo, menor aderência e maior influência das condições meteorológicas. O piso relvado foi apontado como estando associado a um menor risco, mas a maiores níveis de exigência. Maiores amplitudes de variação no movimento de inversão foram identificadas para o piso de relvado natural e que o piso de terra batida foi aquele que ofereceu menor estabilidade aos atletas. O piso de relva artificial foi aquele que mostrou melhor desempenho nos testes aplicados. Este estudo permitiu analisar a influência de um fator externo, o tipo de piso, no risco de entorse em árbitros, permitindo compreender melhor a ocorrência desta lesão nestes profissionais.