5 resultados para Toxoplasmosis - Examinations, Medical

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents work in progress, to develop an efficient and economic way to directly produce Technetium 99metastable (99mTc) using low-energy cyclotrons. Its importance is well established and relates with the increased global trouble in delivering 99mTc to Nuclear Medicine Departments relying on this radioisotope. Since the present delivery strategy has clearly demonstrated its intrinsic limits, our group decided to follow a distinct approach that uses the broad distribution of the low energy cyclotrons and the accessibility of Molybdenum 100 (100Mo) as the Target material. This is indeed an important issue to consider, since the system here presented, named CYCLOTECH, it is not based on the use of Highly Enriched (or even Low Enriched) Uranium 235 (235U), so entirely complying with the actual international trends and directives concerning the use of this potential highly critical material. The production technique is based on the nuclear reaction 100Mo (p,2n) 99mTc whose production yields have already been documented. Until this moment two Patent requests have already been submitted (the first at the INPI, in Portugal, and the second at the USPTO, in the USA); others are being prepared for submission on a near future. The object of the CYCLOTECH system is to present 99mTc to Nuclear Medicine radiopharmacists in a routine, reliable and efficient manner that, remaining always flexible, entirely blends with established protocols. To facilitate workflow and Radiation Protection measures, it has been developed a Target Station that can be installed on most of the existing PET cyclotrons and that will tolerate up to 400 μA of beam by allowing the beam to strike the Target material at an adequately oblique angle. The Target Station permits the remote and automatic loading and discharge of the Targets from a carriage of 10 Target bodies. On other hand, several methods of Target material deposition and Target substrates are presented. The object was to create a cost effective means of depositing and intermediate the target material thickness (25 - 100μm) with a minimum of loss on a substrate that is able to easily transport the heat associated with high beam currents. Finally, the separation techniques presented are a combination of both physical and column chemistry. The object was to extract and deliver 99mTc in the identical form now in use in radiopharmacies worldwide. In addition, the Target material is recovered and can be recycled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tecnologia está em constante evolução e os benefícios, em diversas áreas, que ela nos traz são imensos. Uma das áreas que tem vindo a usufruir desta evolução é a medicina. Os avanços na tecnologia médica têm permitido aos médicos diagnosticar e tratar melhor os seus pacientes. O seu objetivo não é substituir o médico mas sim aconselhá-los e ajudá-los a tomar a melhor decisão face ao caso clínico que possam ter em mãos. Os sistemas de informação estão já tão “entrelaçados” com as práticas médicas que a ideia de uma instituição de prestação de cuidados médicos não os possuir é impensável. Isto porque a informação que estes sistemas processam diariamente é imensa e variadíssima (indo desde relatórios clínicos, a exames efetuados entre outros) para cada utente. As doenças orais fazem parte do grupo de patologias que afetam o maior número de pessoas no mundo. As ações preventivas para estes sintomas devem fazer parte da higiene diária dos indivíduos logo desde os primeiros anos de vida. Assim a aplicação apresentada nesta tese teve como objetivo a sensibilização para uma prática de higiene oral cuidada e constante. Teve também como objetivo a implementação de funcionalidades para gestão de dados dos pacientes da clínica, nomeadamente para o histórico clínico, ficando este armazenado numa anamnese. Para a implementação do presente projeto procedeu-se a um estudo prévio do estado da arte e ao levantamento de requisitos. Estes foram definidos através de reuniões de trabalho onde se analisou as necessidades da clínica com o objetivo de encontrar as soluções que melhor se enquadravam a cada caso. Para garantir que as metas propostas foram alcançadas, foram realizados inquéritos verificando assim o sucesso da aplicação.