32 resultados para Swine Lagoon Effluent
em Instituto Politécnico do Porto, Portugal
Resumo:
The main goal of this research study was the removal of Cu(II), Ni(II) and Zn(II) from aqueous solutions using peanut hulls. This work was mainly focused on the following aspects: chemical characterization of the biosorbent, kinetic studies, study of the pH influence in mono-component systems, equilibrium isotherms and column studies, both in mono and tri-component systems, and with a real industrial effluent from the electroplating industry. The chemical characterization of peanut hulls showed a high cellulose (44.8%) and lignin (36.1%) content, which favours biosorption of metal cations. The kinetic studies performed indicate that most of the sorption occurs in the first 30 min for all systems. In general, a pseudo-second order kinetics was followed, both in mono and tri-component systems. The equilibrium isotherms were better described by Freundlich model in all systems. Peanut hulls showed higher affinity for copper than for nickel and zinc when they are both present. The pH value between 5 and 6 was the most favourable for all systems. The sorbent capacity in column was 0.028 and 0.025 mmol g-1 for copper, respectively in mono and tri-component systems. A decrease of capacity for copper (50%) was observed when dealing with the real effluent. The Yoon-Nelson, Thomas and Yan’s models were fitted to the experimental data, being the latter the best fit.
Resumo:
The main purpose of this study was to examine the applicability of geostatistical modeling to obtain valuable information for assessing the environmental impact of sewage outfall discharges. The data set used was obtained in a monitoring campaign to S. Jacinto outfall, located off the Portuguese west coast near Aveiro region, using an AUV. The Matheron’s classical estimator was used the compute the experimental semivariogram which was fitted to three theoretical models: spherical, exponential and gaussian. The cross-validation procedure suggested the best semivariogram model and ordinary kriging was used to obtain the predictions of salinity at unknown locations. The generated map shows clearly the plume dispersion in the studied area, indicating that the effluent does not reach the near by beaches. Our study suggests that an optimal design for the AUV sampling trajectory from a geostatistical prediction point of view, can help to compute more precise predictions and hence to quantify more accurately dilution. Moreover, since accurate measurements of plume’s dilution are rare, these studies might be very helpful in the future for validation of dispersion models.
Resumo:
This research work has been focused in the study of gallinaceous feathers, a waste that may be valorised as sorbent, to remove the Dark Blue Astrazon 2RN (DBA) from Dystar. This study was focused on the following aspects: optimization of experimental conditions through factorial design methodology, kinetic studies into a continuous stirred tank adsorber (at pH 7 and 20ºC), equilibrium isotherms (at pH 5, 7 and 9 at 20 and 45ºC) and column studies (at 20ºC, at pH 5, 7 and 9). In order to evaluate the influence of the presence of other components in the sorption of the dyestuff, all experiments were performed both for the dyestuff in aqueous solution and in real textile effluent. The pseudo-first and pseudo-second order kinetic models were fitted to the experimental data, being the latter the best fit for the aqueous solution of dyestuff. For the real effluent both models fit the experimental results and there is no statistical difference between them. The Central Composite Design (CCD) was used to evaluate the effects of temperature (15 - 45ºC) and pH (5 - 9) over the sorption in aqueous solution. The influence of pH was more significant than temperature. The optimal conditions selected were 45ºC and pH 9. Both Langmuir and Freundlich models could fit the equilibrium data. In the concentration range studied, the highest sorbent capacity was obtained for the optimal conditions in aqueous solution, which corresponds to a maximum capacity of 47± 4 mg g-1. The Yoon-Nelson, Thomas and Yan’s models fitted well the column experimental data. The highest breakthrough time for 50% removal, 170 min, was obtained at pH 9 in aqueous solution. The presence of the dyeing agents in the real wastewater decreased the sorption of the dyestuff mostly for pH 9, which is the optimal pH. The effect of pH is less pronounced in the real effluent than in aqueous solution. This work shows that feathers can be used as sorbent in the treatment of textile wastewaters containing DBA.
Resumo:
Mestrado em Engenharia Química
Resumo:
The present work aims at evaluating the efficiency of an organic polymer from vegetal source used as coagulant for treating different types of industrial effluents. This coagulant (Flox-QT) is obtained from the Black Acacia (Acacia mearnsii). The effluents studied were produced in petrochemical, leather, cork stoppers, metalworking, olive oil, glue, paint (printing), textile and paper industries. The parameters analyzed in the effluents before and after treatment were selected according to the type of wastewater and included pH, conductivity, apparent colour, turbidity, total suspended solids (TSS), chemical oxygen demand (COD) and some metals. The coagulant proved to be efficient for almost all effluents tested. The best results were obtained for the paper industry wastewater, with 91% removal of chemical oxygen demand and 95% of total suspended solids removal. The estimated cost of this treatment would be only 0.24 Euro per cubic meter of treated effluent, only regarding the price of the coagulant and the required dosage. The use of this coagulant is also adequate for the valorisation of the sludge obtained, which in this case could be recycled for paper production.
Resumo:
O presente trabalho tem como principal objectivo o estudo da possibilidade de recuperação de calor de um efluente proveniente do tratamento primário da fábrica do grupo Portucel Soporcel (fábrica produtora de pasta de papel), para o aquecimento da corrente de lamas do digestor anaeróbio da SimRia S.A. – ETAR Norte, (ambas localizadas em Cacia, distrito de Aveiro). A solução consiste na implementação de um sistema de permuta térmica entre estas duas correntes, constituído fundamentalmente por dois permutadores de placas em espiral, montados em paralelo que operam em contra-corrente. Segundo este novo sistema de aquecimento, as lamas abandonam o digestor anaeróbio da mesma ETAR a um caudal de 110 m3/h, que se dividirá em duas linhas, sendo admitidas em cada permutador a 55 m3/h e a uma temperatura de 32 ºC regressando ao digestor a uma temperatura de 37 ºC (temperatura óptima a que ocorre a digestão anaeróbia das lamas). O efluente disponível, abandona o tratamento primário da Portucel, a 45 ºC e é encaminhado até aos permutadores da SimRia S.A., onde vai trocar calor com as lamas e regressa à Portucel a 40ºC, sendo admitido nas torres de arrefecimento da fábrica de papel. A nova instalação proposta pretende substituir a actual existente na ETAR em causa, em que a corrente de água que aquece as lamas, circula num circuito fechado entre um único permutador e uma caldeira, alimentada com o biogás que se produz no digestor anaeróbio, e que é responsável pelo controlo da temperatura da corrente de água. Pretende-se que a implementação deste novo método de aquecimento de lamas seja uma alternativa económica relativamente ao actual sistema, uma vez que vai substituir a corrente de biogás alimentada à caldeira podendo este recurso ser transformado em energia eléctrica e posteriormente comercializada. A análise financeira realizada ao projecto demonstrou que o projecto é rentável, uma vez que, a diferença entre todos ganhos e custos ao fim dos 10 anos de vida útil estimados é de cerca de 150 000,0 €. O período de retorno do investimento é alcançado no final dos primeiros 6 anos e a taxa interna de rentabilidade obtida foi de 36 %. Posteriormente incluiu-se neste estudo a possibilidade de tratamento das lamas geradas na fábrica da Portucel na ETAR da SimRia recorrendo a um terceiro digestor. Conclui-se que se trata duma opção vantajosa, uma vez que permite obter um caudal de biogás 44 m3/h, que convertido em potência permite obter 150 kW que poderá ser aproveitado para produção de energia ou comercializado gerando uma receita adicional de 130 000,0 €/ano para as entidades envolvidas.
Resumo:
O meio ambiente é uma grande preocupação mundial existindo cada vez mais imposições legais no sentido de o proteger. Torna-se assim necessário que as indústrias adoptem e desenvolvam processos alternativos mais limpos. A indústria de curtumes transforma a pele animal em couro, material resistente à putrefacção e com estabilidade térmica suficiente para ser manufacturado nas indústrias do calçado, estofos, vestuário e marroquinaria. A transformação referida é efectuada através duma série de processos entre os quais o caleiro, processo que visa depilar a pele e promover o relaxamento da estrutura fibrilar, tem um papel importante. O processo de caleiro produz um efluente bastante poluente. Tendo em conta esse facto, este trabalho teve como objectivo desenvolver processos de depilação de pele caprina sem destruição do pêlo, com vista à redução da quantidade de sulfureto e sulfidrato de sódio utilizada e da carga poluente do efluente. Além disso, o processo permite a recuperação do pêlo e este pode ser reaproveitado como fertilizante orgânico, hidrolisado de queratina, compostagem, etc. Todo o trabalho foi realizado tomando por base um processo de caleiro padrão utilizado industrialmente, alterando-o de forma a obter um processo de caleiro óptimo de depilação sem destruição do pêlo com e sem utilização de enzimas. Numa primeira fase, desenvolveu-se um processo de depilação sem destruição do pêlo normalmente utilizado para a pele de bovino que foi adaptado com resultados positivos, designado de processo sem enzimas. Numa segunda fase, desenvolveu-se um processo enzimático em que se utilizou uma protease (Erhavit DMC), uma lipase (Defat 50) e uma amilase (Mayzme SD-L); este processo deu bons resultados tal como o anterior. A redução da quantidade de sulfureto de sódio foi de 33% e 53% para o processo sem enzimas e processo com enzimas, respectivamente, em relação ao processo padrão. O efeito dos processos na carga poluente, à escala piloto, comprova uma redução de 37% nos SST, 37% nos SDT, 60% na CQO, 9% no S2- e 73% no Azoto para o processo sem enzimas e uma redução de 93% nos SST, 63% nos SDT, 69% na CQO, 69% no S2- e 83% no Azoto para o processo com enzimas, quando comparados com o processo padrão. . Uma análise de custos, com incidência apenas nos agentes químicos utilizados, permitiu concluir a existência de uma redução de custos anuais de 30% para o processo com enzimas e de 13% para o processo sem enzimas, quando comparados com o processo padrão. Como conclusão, os processos desenvolvidos apresentam um grande potencial para serem explorados industrialmente.
Resumo:
Este trabalho na área dos processos físicos de separação por membranas, nomeadamente, a nanofiltração (NF), tem como objectivo principal a recuperação dos efluentes resultantes das águas da 3ª lavagem utilizadas na operação de tingimento de fibras de algodão, com corantes reactivos. Estão inerentes as problemáticas: da escassez da água como matéria-prima na vertente de água potável; da diminuição de efluentes que necessitam de tratamentos devido à sua carga poluente; da recuperação sempre que seja viável dos produtos químicos adicionados nesta fase de tratamento das fibras de algodão e por último e não menos importante, da energia contida nestes efluentes que vão para o esgoto a temperaturas na ordem dos 50 ºC. A metodologia adoptada na realização deste trabalho consistiu, inicialmente num estudo sobre os trabalhos realizados até hoje nesta área, seguindo-se a recolha dos efluentes na empresa ―Estamparia Têxtil Adalberto Pinto da Silva, S.A.‖ (ETAPS) e posterior estudo da recuperação dos efluentes em causa pelo processo de NF utilizando a membrana NF270-2540 da empresa FILMTEC. Os efluentes estudados no presente trabalho continham corantes reactivos sendo um corante azul-claro (CAC) de composição (Amarelo Bril Remazol GL 150% + Azul Brilhante Remazol BB 133% + Azul Turqueza Remazol G) e o outro corante azul-marinho (CAM) de composição (Preto Remazol B 133% + Vermelho Remazol RGB + Amarelo Ouro Remazol RGB). Estes estudos de recuperação compreenderam basicamente 3 fases: caracterização do efluente recolhido na empresa; tratamento desse efluente utilizando uma instalação piloto de NF de fluxo cruzado ou também conhecido por membrana de fluxo tangencial instalado no Laboratório de Tecnologia (LT) do Instituto Superior de Engenharia do Porto (ISEP), e caracterização dos permeados e dos rejeitados obtidos. A análise de resultados do presente trabalho permitiu concluir ser possível a recuperação e reutilização das 3ª águas de lavagem do processo de tingimento quando tratadas pelo processo de NF a pressões de operação de 6 bar. Nestas circunstâncias os permeados obtidos (tanto no efluente com corante azul-claro como no efluente com corante azul-marinho) apresentam valores, em todos os parâmetros estudados, significativamente abaixo dos valores limites recomendáveis para uma água de abastecimento na Industria Têxtil (IT). Salienta-se reduções mais expressivas nos permeados do corante CAM, com vários parâmetros a sofrerem reduções no intervalo de 98 a 100%, nomeadamente, na cor, turvação, CQO, dureza total, alumínio e manganês. Os resultados obtidos para as pressões de operação de 4 e 8 bar mostram alguns parâmetros com valores acima dos recomendados para uma água de abastecimento na Indústria Têxtil, nomeadamente a cor no corante CAC quando se opera a 4 bar e no corante CAM quando se opera a 8 bar e os sulfatos e ferro no CAM à pressão de 4 bar. Estes resultados mostram ser possível a reutilização da água na própria instalação industrial, trazendo um benefício económico e ambiental, pela redução no consumo de água fresca e energia, além da redução do volume de efluentes que necessitam ser tratados, estando na mesma linha de pensamento de Gross et al (1999), que refere que o uso de membranas para o tratamento de efluentes do processo de tingimento tem como principal objectivo a viabilidade económica, a redução no consumo de água, de sais, de corantes e energia, bem como, a redução do volume de efluentes a ser tratado.
Resumo:
O presente trabalho tem como objectivo o diagnóstico ambiental da empresa Lacticinios do Paiva, S.A, a avaliação da água do processo e da ETARI e o estudo da fermentação do soro de queijo com o intuito de produção de bioetanol. No diagnóstico ambiental da empresa, observou-se que 18.227.731 litros de leite usados anualmente geram 5.031 ton/ano de queijo, 7.204 ton/ano de soro de queijo, 74.201 m3/ano de efluente liquido, 14 ton/ano de plástico e 20 ton/ano de cartão. Os principais problemas com necessidade de optimização são a recuperação de água das lavagens, avaliação da produção de biogás no digestor anaeróbio, recuperação do volume de leite que é desperdiçado na produção de queijo fresco de longa duração, avaliação da eficiência energética da empresa, valorização das natas e do soro de queijo. Decidiu-se neste trabalho avaliar a possibilidade de reciclagem das águas de lavagem, avaliar o funcionamento da ETARI face à legislação existente e estudar a possibilidade de valorização do soro de queijo. Na avaliação das águas de processo das lavagens para posterior reciclagem, verifica-se que relativamente ao pH e aos sólidos suspensos não existe problema, podendo encarar-se a hipótese de reciclagem directa. No entanto, no que respeita à carga orgânica das águas de lavagem do sistema de ultrafiltração do queijo fresco de longa duração, constata-se que esta não poderia ser utilizada novamente, uma vez que apresenta valores elevados de CQO. Para a sua reutilização, será necessário remover a CQO, hipótese que se estudou com resultados positivos. Verificou-se que, um tratamento por adsorção em carvão activado precedido de microfiltração, reduz a CQO de forma significativa permitindo admitir a hipótese de reciclagem da água, nomeadamente para as 1ª e 3ª águas de lavagem. As outras águas teriam necessidade de mais tempo de contacto com o carvão activado. No sentido de avaliar o funcionamento da ETARI, foram analisadas várias correntes da mesma, em particular a do efluente final, no que respeita a parâmetros como: pH, Sólidos Suspensos Totais, Carência Química de Oxigénio, Carência Bioquímica de Oxigénio, Turvação, Nitratos, Fósforo Total, Azoto Kjeldalh, Azoto Amoniacal e Cloretos. Observou-se que os valores para o efluente final da ETARI são os seguintes: pH compreendido entre [7,21 – 8,69], SST entre [65,3 – 3110] mg/L, CQO entre [92,5 – 711,5] mg/L, CBO5 entre [58 – 161] mg/L, NO3- entre [10,8 – 106,7] mg/L, fósforo total entre [8,3 – 64,3] mg/L, turvação entre [67,7 – 733,3] FTU e cloretos entre [459,9 – 619,81] mg/L; pode-se dizer que os parâmetros analisados se encontram quase sempre dentro da gama de valores impostos pela Câmara Municipal de Lamego pelo que o efluente pode ser lançado no Colector Municipal de Cambres. Relativamente à fermentação alcoólica do soro de queijo, verifica-se que a levedura Kluyveromyces Marxianus consegue degradar praticamente todo o açúcar presente no permeado produzindo assim uma quantidade razoável de etanol. Quando se utilizou a levedura Saccharomyces Cerevisiae, a produção de etanol foi muito reduzida, como esperado, dado que esta levedura apresenta dificuldades na metabolização da lactose. Constatou-se assim que a melhor levedura para a fermentação do permeado do soro de queijo é a Kluyveromyces Marxianus, estimando-se em 150 mg a produção de etanol por L de soro.
Resumo:
The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.
Resumo:
As aparas de wet-blue e de wet-white constituem um resíduo sólido da indústria de curtumes com um elevado teor em carbono, tornando relevante a sua utilização na preparação de materiais de interesse tecnológico. Este trabalho teve como objectivo a preparação de carvões activados a partir de resíduos da indústria de curtumes. Os métodos de activação utilizados para a preparação dos carvões activados foram a activação física com dióxido de carbono e activação química com hidróxido de potássio. A carbonização dos resíduos foi estudada na gama de temperaturas de 500 ºC a 800 ºC, verificando-se que a sua carbonização se pode considerar completa para a temperatura de 800 ºC. Na activação física os precursores foram previamente carbonizados sob uma atmosfera inerte a 800 ºC e posteriormente activados a 940 ºC usando o CO2 como agente activante. Na etapa de activação variou-se o tempo de activação (20, 40 e 60 minutos) de modo a estudar a influência do grau de queima nas propriedades texturais dos carvões activados. O carvão activado obtido pelo método de activação física com maior área superficial específica foi o carvão preparado a partir do resíduo de wet-blue para um tempo de activação de 40 minutos e grau de queima de 23 % (SBET = 152 m2/g). Para a activação química, procedeu-se à impregnação dos precursores com KOH usando razões mássicas de impregnação KOH:precursor de 0,5:1, 1:1 e 3:1. A impregnação foi efectuada directamente nos resíduos de wet-blue e de wet-white e nos resíduos de wet-blue e de wet-white carbonizados. A activação foi efectuada a 940 ºC sob uma atmosfera inerte, com uma velocidade de aquecimento de 5 ºC/min, e um tempo de activação de 1 hora. No caso da série de carvões activados obtidos por impregnação do precursor, o carvão que exibe melhores propriedades texturais é o carvão activado preparado por impregnação na razão de 1:1 a partir do resíduo de wet-blue (SBET = 1696 m2/g). Na série de carvões activados preparados por impregnação do precursor carbonizado, o carvão com melhores propriedades texturais é o carvão proveniente da impregnação do carbonizado do resíduo de wet-blue na razão de 3:1 (SBET = 1507 m2/g). Os carvões activados obtidos por este método de activação são essencialmente microporosos e com elevada área superficial específica. Testes de adsorção preliminares mostram que estes carvões activados têm um bom desempenho para a remoção de cor de efluentes da indústria de curtumes. Concluiu-se que por activação química com KOH dos resíduos de wet-blue e wet-white se obtêm carvões activados com boas propriedades texturais, elevadas áreas superficiais específicas e elevado volume de microporos, quando comparadas com as dos carvões activados resultantes da activação física. Deste modo, chegou-se à conclusão que ambos os resíduos são bons precursores para a produção de carvão activado, mais propriamente recorrendo à activação química, reduzindo assim o volume de resíduos da indústria de curtumes destinados ao aterro.
Resumo:
O presente trabalho experimental teve como objectivos estudar a tratabilidade dum efluente lácteo utilizando a técnica de coagulação/floculação e avaliar a possibilidade de utilização do carvão activado granulado (CAG) Aquasorb 2000 como adsorvente para a remoção de compostos orgânicos presentes nos efluentes lácteos pré–tratados por coagulação/floculação, funcionando como um tratamento de polimento. No estudo da tratabilidade do efluente por coagulação/floculação investigou-se a influência de determinadas variáveis como o tipo e dose de coagulante e pH, a fim de encontrar as melhores condições operatórias. A utilização da referida técnica visou a redução do valor de concentração de alguns parâmetros: carência química de oxigénio (CQO); fósforo total e turvação, tendo sido utilizados efluentes desta indústria recolhidos em diferentes datas e após tratamento biológico, designados por A, B, C e D apresentando características diferentes. Sendo que o efluente A apresentava valores de CQO, fósforo total e turvação de 500 mg O2/L;32 mg P/L e 40 NTU respectivamente, o efluente B 1400 mg O2/L; 120 mg P/L e 80 NTU respectivamente, o efluente C 12300 mg O2/L; 87 mg P/L e 350 NTU respectivamente e o efluente D 340 mg O2/L; 33 mg P/L e 42 NTU respectivamente. Os coagulantes estudados foram hidróxido de cálcio (HC), sulfato de alumínio (SA) e tricloreto de ferro (TF). Verificou-se que o coagulante com maior eficácia nos efluentes estudados foi o TF. As maiores remoções de CQO, fósforo total e turvação, 89%, 99,9% e 99%, respectivamente, foram obtidas para o efluente C, com uma dosagem de TF de 4 g/L e com um pH entre 6 e 7. Entre os efluentes estudados este era o que apresentava valores iniciais mais elevados para qualquer um destes parâmetros. As melhores percentagens de remoção obtidas com o HC, para a CQO, fósforo total e turvação foram de 59%, 99% e 91%, respectivamente, com uma dosagem de HC de 1 g/L e com um pH entre 10 e 11,5 foram conseguidas no tratamento do efluente D, com o qual se alcançaram também as melhores remoções de CQO, fósforo total e turvação de 65%, 99% e 87%, respectivamente, quando se utilizou o coagulante SA, com uma dosagem de 2 g/L e com um pH entre 7 e 7,5. Relativamente ao volume de lamas produzido neste processo pela utilização dos diferentes coagulantes no tratamento dos efluentes referidos concluiu-se que o coagulante que gera menor volume de lamas é o HC, sendo o SA aquele que origina um maior volume. Submeteu-se posteriormente o efluente D, pré-tratado por coagulação/floculação, a um processo de adsorção em batch utilizando o CAG Aquasorb 2000, onde se conseguiu uma remoção de CQO de 48%, alcançando para este parâmetro o valor de 63 mg O2/L, nas condições operatórias que correspondem a uma massa de CAG de 12,5 g/L e um tempo de contacto de 3 horas. Quanto aos custos associados com os coagulantes, o que menores custos apresenta é o HC (150 €/ton), seguido pelo TF (250 €/ton) e por ultimo o SA (340 €/ton). Sendo que o efluente quando tratado com TF e SA é necessário uma correcção do pH do meio para que estes coagulantes actuem eficazmente, em que essa correcção de pH é realizada com hidróxido de sódio (540 €/ton). Realizaram-se ainda estudos de equilíbrio de adsorção com o carvão activado referido e o azul-de-metileno usando diferentes concentrações deste (50 mg/L; 100 mg/L e 200 mg/L) e diferentes massas de CAG (0,1g; 0,2g; 0,3g; 0,4g e 0,5g). A temperatura a que se realizaram estes ensaios foi de 28,7ºC e o volume de azul-de-metileno foi de 200 mL. Verificou-se que os melhores resultados obtidos foram para uma concentração de adsorvato de 100 mg/L. Ajustaram-se os modelos de Langmuir e Freundlich às isotérmicas obtidas tendo correlações mais elevadas para a concentração de 100 mg/L de corante (azul de metileno), sendo o modelo de Freundlich aquele que melhor se ajustou apresentando uma correlação quadrática de 0,9744 e os seguintes parâmetros Kf = 6,59 e n = 5,33, enquanto que o de Langmuir apresentou uma correlação quadrática de 0,9583 e os seguintes parâmetros qmáx = 83,3 mg/g de adsorvente e K = 20 L/mg de adsorvato.. Verificou-se que a capacidade de adsorção promovida pelo CAG, em relação ao azul-demetileno, obtida experimentalmente, 83,3 mg/g, é muito inferior à capacidade de adsorção teoricamente prevista pela ficha técnica deste carvão, 280 mg/g a uma temperatura de 25ºC, o que pode indiciar que o carvão utilizado não estaria nas melhores condições.
Resumo:
A Mundotêxtil foi fundada em 1975 tendo iniciado a sua actividade na área comercial de produtos têxteis. Actualmente é o maior produtor nacional de atoalhados de felpo e emprega 575 colaboradores. Como resultado do seu crescimento e sobretudo da actividade de tingimento de fio e felpo, as necessidades de água são consideráveis e o volume de efluentes gerados nos processos industriais é cada vez maior a empresa avançou com a construção de uma estação de tratamento por lamas activadas, colocando-a em funcionamento em Setembro de 2004. Inicialmente surgiram dificuldades para a remoção da cor e da concentração da Carência Química de Oxigénio (CQO) de modo a cumprir os limites máximos de emissão permitidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98, de 1 de Agosto. Com a descarga de parte dos efluentes no SIDVA e a utilização de um coagulante adicionado ao reactor o tratamento passou a apresentar melhores resultados. O intuito deste trabalho é o de apresentar soluções de modo a optimizar o funcionamento do tratamento biológico da Mundotêxtil. A optimização pode começar na concepção dos produtos, pode incidir no processo de fabrico para além de poder ser efectuada no seio da estação de tratamento biológico. Foi efectuado um estudo do tratamento biológico por lamas activadas no Laboratório de Tecnologia Química Profª Doutora Lída de Vasconcelos, laboratório tecnológico do Instituto Superior de Engenharia do Porto (ISEP) que decorreu nos meses de Maio, Junho e Julho de 2010. O estudo laboratorial foi efectuado para três situações distintas: 1) tratamento do efluente bruto sem qualquer tipo de pré-tratamento (ensaios 1 a 3); 2) tratamento do efluente bruto submetido a pré-tratamento com coagulante Ambifloc BIO MD (ensaios 4 e 5) e 3) tratamento com adição de fungos ao tanque de arejamento (ensaio 6). Foram utilizadas duas instalações de tratamento alimentadas a partir do mesmo tanque de alimentação. Os dois sistemas eram idênticos, diferiram nos caudais de alimentação de efluente que foram alterados ao longo do estudo. O efluente a tratar foi fornecido pela empresa Mundotêxtil, sendo recolhido por diversas vezes ao longo dos ensaios. Este efluente foi retirado após o pré-tratamento da empresa, ou seja este efluente é o mesmo que alimenta o tratamento biológico da Mundotêxtil. Devido a este facto o efluente usado no estudo laboratorial teve uma variabilidade no período em que decorreu o estudo, nomeadamente em termos de concentração de CQO e cor. A relação entre a Carência Bioquímica (CBO5) e a CQO situouse entre 0,47 e 0,63 o que traduz que está dentro dos valores típicos para um efluente têxtil. Os melhores resultados globais de remoção de CQO foram obtidos no ensaio 5 e estiveram compreendidos entre 73,2% e 77,5% para o ensaio 5.1 e entre 62,9 e 73,2% para o ensaio 5.2. Neste ensaio foi utilizado o coagulante. Todos os valores de concentração de CQO obtidos nos efluentes dos decantadores para os ensaios 2, 5 e 6 são inferiores aos valores limite de descarga definidos nas normas de descarga no rio Ave e o Decreto-Lei 236/98. Os valores de concentração de Sólidos Suspensos Totais (SST), pH, fósforo, CBO5 e cor nos decantadores cumpriram os limites de descarga definidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98 em todos os ensaios. Os parâmetros cinéticos obtidos para os ensaios com descorante são os que melhor se ajustam ao projecto de uma instalação de tratamento biológico por lamas activadas do efluente da Mundotêxtil. Os valores obtidos, após ajuste, são os seguintes: k=0,015 L/(mgSSV*d); Sn=12 mg/L; a=0,7982 kgO2/kgCBO5; b=0,0233 [kgO2/(kgSSV*d); y=0,2253 kgSSV/kgCBO5; kd=0,0036 kgSSV/(kgSSV*d. Com base nos parâmetros cinéticos obtiveram-se os seguintes resultados para o projecto de uma estação de tratamento biológico por lamas activadas: · Tempo de retenção hidráulica no reactor de 1,79 d, · Volume do reactor igual a 3643 m3 · Consumo de oxigénio no reactor de 604 kg/d · Razão de recirculação igual a 0,8 · Volume total do decantador secundário igual a 540 m3 · Diâmetro do decantador secundário igual a 15 m A quantidade de oxigénio necessário é baixa e o valor mais adequado deverá ser da ordem de 1200 kg/d. Também foi efectuada uma análise aos produtos químicos consumidos pela empresa na área das tinturarias com a finalidade de identificar as substâncias com uma maior influência potencial no funcionamento da Estação de Tratamento Biológico. O encolante CB, Cera Têxtil P Líquida, Perfemina P-12, Meropan DPE-P, Meropan BRE-P, Indimina STS e Benzym TEC são os produtos químicos que têm uma influência potencial mais significativa na qualidade dos efluentes. Devido ao facto das temperaturas do efluente alimentado ao tratamento biológico da Mundotêxtil oscilarem entre 35 ºC e 43ºC efectuou-se um estudo às necessidades de água quente das tinturarias e por outro lado à capacidade de aquecimento dos efluentes disponíveis. Actualmente a racionalização dos consumos de água é cada vez mais premente, por isso também é apresentado neste trabalho um estudo para a substituição das máquinas convencionais das tinturarias com uma relação de banho 1:10 por máquinas de banho curto (1:6,5). Verifica-se a redução de consumos de 40% de água, 52% de energia eléctrica, 35% de produtos químicos, 51% das necessidades de vapor e por consequência um aumento da produtividade. A empresa pode reduzir os consumos de água em cerca de 280.000 m3/ano. A utilização do pré-tratamento com o coagulante permitirá baixar a concentração da CQO e reduzir a cor à entrada do reactor tratamento biológico. Deste modo é possível manter um tratamento eficiente à saída do tratamento biológico nas situações de descarga de cores carregadas e carga orgânica elevada. Com este conjunto de soluções, quer sejam aplicadas na totalidade ou não, a empresa Mundotêxtil pode enfrentar o futuro com mais confiança podendo estar preparada para fazer face à escassez de água e custos cada vez maiores da energia. Por outro lado pode tratar os seus efluentes a custos menores. A substituição das máquinas de tingimento por máquinas com relação de banho mais baixa (banho curto) implica investimentos elevados mas estes investimentos são necessários não só por motivos ambientais mas também devido à grande competitividade dos mercados.
Resumo:
Foram utilizados como elemento principal de estudo, os efluentes líquidos dos processos industriais da ENDUTEX, Tinturaria e Acabamento de Malhas, S. A. localizada no município de Caldas de Vizela, distrito de Braga. O estudo foi realizado na empresa devido ao interesse da mesma em poder reaproveitar o calor libertado nos efluentes para aquecimento de parte da água captada no rio de Vizela. O objectivo do trabalho consiste no dimensionamento de um permutador de calor que permita satisfazer o interesse da empresa, assim como, um estudo económico relativo aos custos envolventes. Com o intuito de concretizar os objectivos propostos foram realizadas visitas semanais à empresa para se proceder ao levantamento de dados e para a realização de amostragens do efluente para posterior caracterização. Depois de efectuado o dimensionamento do permutador de placas para diferentes caudais e temperaturas dos fluidos, frio (água do rio) e quente (efluentes), concluiu-se que as condições mais rentáveis correspondiam a um caudal de fluido frio de 17 m3/h em que a temperatura de entrada e de saída no permutador seria de 14 ºC e 48 ºC, respectivamente. O caudal de fluido quente seria de 20 m3/h, sendo a temperatura de entrada e de saída no permutador de 62 ºC e 33,1 ºC, respectivamente. Como resultado do dimensionamento obteve-se um permutador de placas com 167 placas em que o coeficiente global de transferência de calor (U) é de 726,9 W/m2ºC, a área projectada de 55,7 m2 e a queda de pressão de 0,904 KPa. Foi consultada a empresa ARSOPI-THERMAL para verificação das características dos permutadores existentes no mercado. No entanto, para as mesmas condições foi sugerido um permutador com 31 placas em que o coeficiente global de transferência de calor (U) é de 6267 W/m2ºC, a área projectada de 7,39 m2 e a queda de pressão de 76 KPa. A diferença verificada nos resultados apresentados pode ter origem na utilização de diferentes expressões no cálculo do coeficiente pelicular de transferência de calor (h) e pelo facto da ARSOPI desprezar o factor de sujamento no seu dimensionamento Na análise económica do projecto é de referir que para o arranque do projecto foi feito o levantamento das necessidades de investimento, situando-se este num valor total de 9640€, sendo o investimento financiado apenas por capitais próprios. O prazo de recuperação do investimento (Pay Back Period) é de cerca de 2 meses.
Resumo:
The impact of effluent wastewaters from four different hospitals: a university (1456 beds), a general (350 beds), a pediatric (110 beds) and a maternity hospital (96 beds), which are conveyed to the same wastewater treatment plant (WWTP), was evaluated in the receiving urban wastewaters. The occurrence of 78 pharmaceuticals belonging to several therapeutic classes was assessed in hospital effluents and WWTP wastewaters (influent and effluent) as well as the contribution of each hospital in WWTP influent in terms of pharmaceutical load. Results indicate that pharmaceuticals are widespread pollutants in both hospital and urban wastewaters. The contribution of hospitals to the input of pharmaceuticals in urban wastewaters widely varies, according to their dimension. The estimated total mass loadings were 306 g d− 1 for the university hospital, 155 g d− 1 for the general one, 14 g d− 1 for the pediatric hospital and 1.5 g d− 1 for the maternity hospital, showing that the biggest hospitals have a greater contribution to the total mass load of pharmaceuticals. Furthermore, analysis of individual contributions of each therapeutic group showed that NSAIDs, analgesics and antibiotics are among the groups with the highest inputs. Removal efficiency can go from over 90% for pharmaceuticals like acetaminophen and ibuprofen to not removal for β-blockers and salbutamol. Total mass load of pharmaceuticals into receiving surface waters was estimated between 5 and 14 g/d/1000 inhabitants. Finally, the environmental risk posed by pharmaceuticals detected in hospital and WWTP effluents was assessed by means of hazard quotients toward different trophic levels (algae, daphnids and fish). Several pharmaceuticals present in the different matrices were identified as potentially hazardous to aquatic organisms, showing that especial attention should be paid to antibiotics such as ciprofloxacin, ofloxacin, sulfamethoxazole, azithromycin and clarithromycin, since their hazard quotients in WWTP effluent revealed that they could pose an ecotoxicological risk to algae.