10 resultados para Signal sets matched to groups
em Instituto Politécnico do Porto, Portugal
Resumo:
Debugging electronic circuits is traditionally done with bench equipment directly connected to the circuit under debug. In the digital domain, the difficulties associated with the direct physical access to circuit nodes led to the inclusion of resources providing support to that activity, first at the printed circuit level, and then at the integrated circuit level. The experience acquired with those solutions led to the emergence of dedicated infrastructures for debugging cores at the system-on-chip level. However, all these developments had a small impact in the analog and mixed-signal domain, where debugging still depends, to a large extent, on direct physical access to circuit nodes. As a consequence, when analog and mixed-signal circuits are integrated as cores inside a system-on-chip, the difficulties associated with debugging increase, which cause the time-to-market and the prototype verification costs to also increase. The present work considers the IEEE1149.4 infrastructure as a means to support the debugging of mixed-signal circuits, namely to access the circuit nodes and also an embedded debug mechanism named mixed-signal condition detector, necessary for watch-/breakpoints and real-time analysis operations. One of the main advantages associated with the proposed solution is the seamless migration to the system-on-chip level, as the access is done through electronic means, thus easing debugging operations at different hierarchical levels.
Resumo:
Purpose: This study investigated the influence of long-term wearing of unstable shoes (WUS) on compensatory postural adjustments (CPA) to an external perturbation. Methods: Participants were divided into two groups: one wore unstable shoes while the other wore conventional shoes for 8 weeks. The ground reaction force signal was used to calculate the anterior– posterior (AP) displacement of the centre of pressure (CoP) and the electromyographic signal of gastrocnemius medialis (GM), tibialis anterior (TA), rectus femoris (RF) and biceps femoris (BF) muscles was used to assess individual muscle activity, antagonist co-activation and reciprocal activation at the joint (TA/GM and RF/(BF + GM) pairs) and muscle group levels (ventral (TA + RF)/dorsal (GM + BF) pair) within time intervals typical for CPA. The electromyographic signal was also used to assess muscle latency. The variables described were evaluated before and after the 8-week period while wearing the unstable shoes and barefoot. Results: Long-term WUS led to: an increase of BF activity in both conditions (barefoot and wearing the unstable shoes); a decrease of GM activity; an increase of antagonist co-activation and a decrease of reciprocal activation level at the TA/GM and ventral/dorsal pairs in the unstable shoe condition. Additionally, WUS led to a decrease in CoP displacement. However, no differences were observed in muscle onset and offset. Conclusion: Results suggest that the prolonged use of unstable shoes leads to increased ankle and muscle groups’ antagonist co-activation levels and higher performance by the postural control system.
Resumo:
This paper reports on the analysis of tidal breathing patterns measured during noninvasive forced oscillation lung function tests in six individual groups. The three adult groups were healthy, with prediagnosed chronic obstructive pulmonary disease, and with prediagnosed kyphoscoliosis, respectively. The three children groups were healthy, with prediagnosed asthma, and with prediagnosed cystic fibrosis, respectively. The analysis is applied to the pressure–volume curves and the pseudophaseplane loop by means of the box-counting method, which gives a measure of the area within each loop. The objective was to verify if there exists a link between the area of the loops, power-law patterns, and alterations in the respiratory structure with disease. We obtained statistically significant variations between the data sets corresponding to the six groups of patients, showing also the existence of power-law patterns. Our findings support the idea that the respiratory system changes with disease in terms of airway geometry and tissue parameters, leading, in turn, to variations in the fractal dimension of the respiratory tree and its dynamics.
Resumo:
This paper reports on the analysis of tidal breathing patterns measured during noninvasive forced oscillation lung function tests in six individual groups. The three adult groups were healthy, with prediagnosed chronic obstructive pulmonary disease, and with prediagnosed kyphoscoliosis, respectively. The three children groups were healthy, with prediagnosed asthma, and with prediagnosed cystic fibrosis, respectively. The analysis is applied to the pressure-volume curves and the pseudophase-plane loop by means of the box-counting method, which gives a measure of the area within each loop. The objective was to verify if there exists a link between the area of the loops, power-law patterns, and alterations in the respiratory structure with disease. We obtained statistically significant variations between the data sets corresponding to the six groups of patients, showing also the existence of power-law patterns. Our findings support the idea that the respiratory system changes with disease in terms of airway geometry and tissue parameters, leading, in turn, to variations in the fractal dimension of the respiratory tree and its dynamics.
Resumo:
Esta dissertação propõe o desenvolvimento de um sistema capaz de adquirir e monitorizar num computador o sinal do electrocardiograma (ECG) e de detectar o pico R do complexo QRS do referido sinal. Numa primeira fase foi efectuado um estudo do sistema cardiovascular, de forma a compreender a actividade eléctrica do coração e dos diversos sinais que constituem o ECG. Foi efectuado um estudo sobre o sinal ECG, tendo sido estudadas as suas características, bem como técnicas e componentes básicos de aquisição e condicionamento do sinal, sendo também analisados diversos sistemas que efectuam a aquisição de ECG. Numa segunda fase foram estudadas as Field Programmable Analog Array (FPAA), analisando o estado da arte desta tecnologia, bem como os dispositivos disponíveis comercialmente. Após esta análise foram seleccionados os dispositivos FPAA, bem como o restante hardware e software necessários para a realização desta Tese. Foi desenvolvido um sistema de condicionamento de sinal ECG, e de detecção de pico R do complexo QRS, apenas com componentes analógicos discretos tendo sido analisados os resultados obtidos antes de se avançar para a fase seguinte. Após a realização do sistema com componentes discretos, foi implementado um sistema em que grande parte do condicionamento do sinal ECG é efectuado por duas placas de desenvolvimento FPAA, de forma a diminuir a quantidade de componentes e a obter um sinal com melhor resolução. Os resultados obtidos foram analisados e comparados com o sistema desenvolvido. Para monitorizar o sinal ECG e o pico R num computador, foi desenvolvido um sistema em que os sinais são convertidos pelo conversor A/D de um microcontrolador, e enviados por comunicação série para um computador, sendo os valores obtidos visualizados numa aplicação em ambiente MATLAB.
Resumo:
This study investigated the influence of wearing unstable shoe construction (WUS) on compensatory postural adjustments (CPA) associated with external perturbations. Thirty-two subjects stood on a force platform resisting an anterior-posterior horizontal force applied to a pelvic belt via a cable, which was suddenly released. They stood under two conditions: barefoot and WUS. The electromyographic (EMG) activity of gastrocnemius medialis, tibialis anterior, rectus femoris, biceps femoris, rectus abdominis, and erector spinae muscles and the center of pressure (CoP) displacement were acquired to study CPA. The EMG signal was used to assess individual muscle activity and latency, antagonist co-activation and reciprocal activation at joint and muscle group levels. Compared to barefoot, WUS led to: (1) increased gastrocnemius medialis activity, (2) increased total agonist activity, (3) decreased antagonist co-activation at the ankle joint and muscle group levels, (4) increased reciprocal activation at the ankle joint and muscle group levels, and (5) decrease in all muscle latencies. No differences were observed in CoP displacement between conditions. These findings demonstrate that WUS led to a reorganization of the postural control system associated to improved performance of some components of postural control responses.
Resumo:
Fingerprinting is an indoor location technique, based on wireless networks, where data stored during the offline phase is compared with data collected by the mobile device during the online phase. In most of the real-life scenarios, the mobile node used throughout the offline phase is different from the mobile nodes that will be used during the online phase. This means that there might be very significant differences between the Received Signal Strength values acquired by the mobile node and the ones stored in the Fingerprinting Map. As a consequence, this difference between RSS values might contribute to increase the location estimation error. One possible solution to minimize these differences is to adapt the RSS values, acquired during the online phase, before sending them to the Location Estimation Algorithm. Also the internal parameters of the Location Estimation Algorithms, for example the weights of the Weighted k-Nearest Neighbour, might need to be tuned for every type of terminal. This paper focuses both approaches, using Direct Search optimization methods to adapt the Received Signal Strength and to tune the Location Estimation Algorithm parameters. As a result it was possible to decrease the location estimation error originally obtained without any calibration procedure.
Resumo:
In practice the robotic manipulators present some degree of unwanted vibrations. The advent of lightweight arm manipulators, mainly in the aerospace industry, where weight is an important issue, leads to the problem of intense vibrations. On the other hand, robots interacting with the environment often generate impacts that propagate through the mechanical structure and produce also vibrations. In order to analyze these phenomena a robot signal acquisition system was developed. The manipulator motion produces vibrations, either from the structural modes or from endeffector impacts. The instrumentation system acquires signals from several sensors that capture the joint positions, mass accelerations, forces and moments, and electrical currents in the motors. Afterwards, an analysis package, running off-line, reads the data recorded by the acquisition system and extracts the signal characteristics. Due to the multiplicity of sensors, the data obtained can be redundant because the same type of information may be seen by two or more sensors. Because of the price of the sensors, this aspect can be considered in order to reduce the cost of the system. On the other hand, the placement of the sensors is an important issue in order to obtain the suitable signals of the vibration phenomenon. Moreover, the study of these issues can help in the design optimization of the acquisition system. In this line of thought a sensor classification scheme is presented. Several authors have addressed the subject of the sensor classification scheme. White (White, 1987) presents a flexible and comprehensive categorizing scheme that is useful for describing and comparing sensors. The author organizes the sensors according to several aspects: measurands, technological aspects, detection means, conversion phenomena, sensor materials and fields of application. Michahelles and Schiele (Michahelles & Schiele, 2003) systematize the use of sensor technology. They identified several dimensions of sensing that represent the sensing goals for physical interaction. A conceptual framework is introduced that allows categorizing existing sensors and evaluates their utility in various applications. This framework not only guides application designers for choosing meaningful sensor subsets, but also can inspire new systems and leads to the evaluation of existing applications. Today’s technology offers a wide variety of sensors. In order to use all the data from the diversity of sensors a framework of integration is needed. Sensor fusion, fuzzy logic, and neural networks are often mentioned when dealing with problem of combing information from several sensors to get a more general picture of a given situation. The study of data fusion has been receiving considerable attention (Esteban et al., 2005; Luo & Kay, 1990). A survey of the state of the art in sensor fusion for robotics can be found in (Hackett & Shah, 1990). Henderson and Shilcrat (Henderson & Shilcrat, 1984) introduced the concept of logic sensor that defines an abstract specification of the sensors to integrate in a multisensor system. The recent developments of micro electro mechanical sensors (MEMS) with unwired communication capabilities allow a sensor network with interesting capacity. This technology was applied in several applications (Arampatzis & Manesis, 2005), including robotics. Cheekiralla and Engels (Cheekiralla & Engels, 2005) propose a classification of the unwired sensor networks according to its functionalities and properties. This paper presents a development of a sensor classification scheme based on the frequency spectrum of the signals and on a statistical metrics. Bearing these ideas in mind, this paper is organized as follows. Section 2 describes briefly the robotic system enhanced with the instrumentation setup. Section 3 presents the experimental results. Finally, section 4 draws the main conclusions and points out future work.
Resumo:
Introdução: A aplicação das técnicas de Contrair-Relaxar com Contracção do Antagonista (CRCA) e de Músculo Energia (TME) promovem um aumento da flexibilidade muscular, contudo poucos estudos comparam a eficácia de ambas. Apresentam aspectos comuns como a contracção prévia do músculo a alongar sendo esta máxima na CRCA e uma percentagem da máxima na TME. Contudo, alguma evidência sugere que não existe correspondência entre a força produzida e a desejada pelo que este aspecto da TME carece de explicação. Objectivos: Confirmar se a técnica CRCA e a TME são efectivas no alongamento muscular dos isquiotibiais a curto prazo, caso sejam determinar qual a mais efectiva. Pretende-se ainda avaliar se a percepção ao esforço durante a aplicação da TME corresponde à força efectivamente realizada. Métodos: Efectuou-se um estudo experimental com 45 voluntários distribuídos aleatoriamente pelos grupos CRCA, TME e Controlo. Avaliou-se a amplitude articular passiva de extensão do joelho antes e depois de aplicar as técnicas, utilizando um goniómetro. Nos participantes submetidos à TME avaliou-se a percepção ao esforço, solicitando uma contracção submáxima isométrica de 40% medida através do dinamómetro de mão. Resultados: Verificou-se um efeito das técnicas entre as avaliações (Teste ANOVA medidas repetidas factor tempo: p<0,001) e entre os grupos (tempo*grupo: p<0,001). Comparando os grupos dois a dois, verificaram-se diferenças entre o grupo CRCA e o grupo Controlo (Teste Post Hoc Games-Howell: p=0,001) e entre o grupo TME e o grupo Controlo (p=0,009), não existindo diferenças entre os grupos CRCA e TME (p=0,376). Os grupos CRCA e TME obtiveram um ganho de 10,7º e de 11,4º respectivamente, não havendo diferenças significativas entre os ganhos (Teste T-Student Independente: p=0,599). Existiram diferenças significativas entre os 40% CMVI produzida e desejada (Teste Wilcoxon: p=0,018). Conclusão: Ambas foram efectivas no aumento da flexibilidade muscular dos isquiotibiais a curto prazo. Os efeitos foram comparáveis, mas dada a menor complexidade e menor solicitação a TME foi considerada mais eficiente. A percepção ao esforço durante a aplicação da TME não correspondeu ao esforço desejado, existindo uma tendência para a produção de intensidades de contracções maiores.
Resumo:
Os sistemas de monitorização de estruturas fornecem diversas vantagens, não só no que diz respeito à durabilidade da obra, ao aumento da segurança e do conhecimento relativamente ao comportamento das estruturas ao longo do tempo, à otimização do aspeto estrutural, bem como aos aspetos económicos do processo de construção e manutenção. A monitorização deve realizar-se durante a fase de construção e/ou de exploração da obra para permitir o registo integral do seu comportamento no meio externo. Deve efetuar-se de forma contínua e automática, executando intervenções de rotina para que se possa detetar precocemente sinais de alterações, respetivamente à segurança, integridade e desempenho funcional. Assim se poderá manter a estrutura dentro de parâmetros aceitáveis de segurança. Assim, na presente dissertação será concebido um demonstrador experimental, para ser estudado em laboratório, no qual será implementado um sistema de monitorização contínuo e automático. Sobre este demonstrador será feita uma análise de diferentes grandezas em medição, tais como: deslocamentos, extensões, temperatura, rotações e acelerações. Com carácter inovador, pretende-se ainda incluir neste modelo em sintonia de medição de coordenadas GNSS com o qual se torna possível medir deslocamentos absolutos. Os resultados experimentais alcançados serão analisados e comparados com modelos numéricos. Conferem-se os resultados experimentais de natureza estática e dinâmica, com os resultados numéricos de dois modelos de elementos finitos: um de barras e outro de casca. Realizaram-se diferentes abordagens tendo em conta as características identificadas por via experimental e calculadas nos modelos numéricos para melhor ajuste e calibração dos modelos numéricos Por fim, recorre-se a algoritmos de processamento e tratamento do respetivo sinal com aplicação de filtros, que revelam melhorar com rigor o sinal, de forma a potenciar as técnicas de fusão multisensor. Pretende-se integrar o sinal GNSS com os demais sensores presentes no sistema de monitorização. As técnicas de fusão multisensor visam melhor o desempenho deste potencial sistema de medição, demonstrando as suas valências no domínio da monitorização estrutural.