13 resultados para Reagent Strips
em Instituto Politécnico do Porto, Portugal
Resumo:
GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.
Resumo:
Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.
Resumo:
O presente trabalho teve como principais objectivos, estudar e optimizar o processo de tratamento do efluente proveniente das máquinas da unidade Cold-press da linha de produção da Empresa Swedwood, caracterizar a solução límpida obtida no tratamento e estudar a sua integração no processo, e por fim caracterizar o resíduo de pasta de cola obtido no tratamento e estudar a possível valorização energética deste resíduo. Após caracterização inicial do efluente e de acordo com os resultados de um estudo prévio solicitado pela Empresa Swedwood a uma empresa externa, decidiu-se iniciar o estudo de tratabilidade do efluente pelo processo físico-químico a coagulação/floculação. No processo de coagulação/floculação estudou-se a aplicabilidade, através de ensaios Jar-test, dos diferentes agentes de coagulação/floculação: a soda cáustica, a cal, o cloreto férrico e o sulfato de alumínio. Os melhores resultados neste processo foram obtidos com a adição de uma dose de cal de 500 mg/Lefluente, seguida da adição de 400 mg/Lefluente de sulfato de alumínio. Contudo, após este tratamento o clarificado obtido não possuía as características necessárias para a sua reintrodução no processo fabril nem para a sua descarga em meio hídrico. Deste modo procedeu-se ao estudo de tratamentos complementares. Nesta segunda fases de estudo testaram-se os seguintes os tratamentos: a oxidação química por Reagente de Fenton, o tratamento biológico por SBR (sequencing batch reactor) e o leito percolador. Da análise dos resultados obtidos nos diferentes tratamentos conclui-se que o tratamento mais eficaz foi o tratamento biológico por SBR com adição de carvão activado. Prevê-se que no final do processo de tratamento o clarificado obtido possa ser descarregado em meio hídrico ou reintroduzido no processo. Como o estudo apenas foi desenvolvido à escala laboratorial, seria útil poder validar os resultados numa escala piloto antes da sua implementação industrial. A partir dos resultados do estudo experimental, procedeu-se ao dimensionamento de uma unidade de tratamento físico-químico e biológico à escala industrial para o tratamento de 20 m3 de efluente produzido na fábrica, numa semana. Dimensionou-se ainda a unidade (leito de secagem) para tratamento das lamas produzidas. Na unidade de tratamento físico-químico (coagulação/floculação) os decantadores estáticos devem possuir o volume útil de 4,8 m3. Sendo necessários semanalmente 36 L da suspensão de cal (Neutrolac 300) e 12,3 L da solução de sulfato de alumínio a 8,3%. Os tanques de armazenamento destes compostos devem possuir 43,2 litros e 96 litros, respectivamente. Nesta unidade estimou-se que são produzidos diariamente 1,4 m3 de lamas. Na unidade de tratamento biológico o reactor biológico deve possuir um volume útil de 6 m3. Para que este processo seja eficaz é necessário fornecer diariamente 2,1 kg de oxigénio. Estima-se que neste processo será necessário efectuar a purga de 325 litros de lamas semanalmente. No final da purga repõe-se o carvão activado, que poderá ser arrastado juntamente com as lamas, adicionando-se 100 mg de carvão por litro de licor misto. De acordo com o volume de lamas produzidos em ambos os tratamentos a área mínima necessária para o leito de secagem é de cerca de 27 m2. A análise económica efectuada mostra que a aquisição do equipamento tem o custo de 22.079,50 euros, o custo dos reagentes necessários neste processo para um ano de funcionamento tem um custo total de 508,50 euros e as necessidades energéticas de 2.008,45 euros.
Resumo:
Actualmente, a poluição do ar, água e solo são problemáticas nas quais se têm centrado diversos estudos. Reduzir ou eliminar a concentração dos diversos poluentes presentes nestes meios é uma meta que se pretende atingir. Neste âmbito, têm sido desenvolvidos diversos estudos e trabalhos, utilizando diversas tecnologias, como químicas e biológicas, de forma a conseguir-se atingir este fim. Esta tese teve como principal objectivo estudar a remediação de solos contaminados com produtos farmacêuticos recorrendo à oxidação/redução química. Assim, começou por se estudar a remediação de água contaminada com ibuprofeno, uma vez, que a matriz líquida é mais fácil de estudar que o solo. Neste âmbito escolheram-se os seguintes reagentes para estudar a descontaminação da água: permanganato de potássio, reagente de Fenton e nanopartículas de ferro zero valente. Analisando os resultados obtidos nestas análises, verificou-se que o permanganato de potássio não foi capaz de reduzir a concentração de ibuprofeno presente na água. No entanto, o reagente de Fenton e as nanopartículas produzidas a partir do extracto da casca de castanha e do chá conseguirem reagir com o ibuprofeno, apresentando taxas de degradação de 90 % e 77 %, respectivamente, nas melhores condições experimentadas. Com os resultados obtidos, passou-se a analisar solos contaminados com o ibuprofeno, utilizando o reagente de Fenton e as nanopartículas produzidas a partir de um extracto de chá. Verificou-se que estes reagentes conseguiram reduzir a concentração de ibuprofeno presente no solo (areia) para valores residuais, obtendo-se taxas de degradação acima de 95 % após 5 dias de reacção. Conclui-se que, o objectivo principal desta tese foi cumprido pois foi reduzida, e quase eliminada, a concentração do ibuprofeno presente no solo, recorrendo à oxidação/redução química.
Resumo:
A presente dissertação descreve o desenvolvimento e a caracterização de sensores potenciométricos com base em polímeros de impressão molecular e de sensores ópticos com base em membranas de poli(cloreto de vinilo), PVC, para a determinação de cobre em vinhos verdes. Os sensores potenciométricos foram preparados a partir de diferentes solventes (metanol e clorofórmio), tendo o seu crescimento decorrido na presença ou ausência da molécula molde (cobre). Os sistemas sensores selectivos ao cobre continham partículas de polímeros com ou sem impressão molecular como material electroactivo, dispersas em solvente plastificante, PVC e, em alguns casos, aditivo aniónico. A avaliação dos vários sistemas baseou-se na comparação das características operacionais dos diversos eléctrodos onde foram aplicados. Estas características foram obtidas a partir de curvas de calibração, cujos declives e limites de detecção variaram entre -39,9 – 37,0 mV decada-1 e 4,2 – 29,1 μg mL-1, respectivamente. Os sensores não são independentes do pH uma vez que o complexo formado entre o cobre e a difenilcarbazida é favorecido por valores de pH próximos de 5. Assim, obtiveram-se melhores resultados usando água desionizada ou solução tampão de HEPES revelando-se um método rápido e relativamente eficaz nestas condições. Os sensores ópticos basearam-se na reacção colorimétrica entre o cobre e um complexante. Os reagentes complexantes escolhidos foram a neocuproína, a difenilcarbazida e o dietilditiocarbamato de sódio. Avaliou-se o efeito de vários parâmetros experimentais na resposta destes sensores, tais como o pH (avaliado para os valores 3,00 e 5,00), a concentração de cobre (que variou entre 0,06 e 317,7 mg L- 1) e as próprias características da membrana. Os melhores resultados foram obtidos a pH 3, numa gama de concentrações de 0,06 e 31,8 mg L-1 usando a difenilcarbazida como reagente complexante. A aplicação destes sensores a vinhos requer ainda estudos adicionais, especialmente no que diz respeito à necessidade de implementar algum procedimento de pré-tratamento de amostra.
Resumo:
Os produtos farmacêuticos são substâncias químicas muito utilizados em medicina, veterinária e ainda na agricultura. Nos anos 90, foi descoberta a presença de fármacos em meio aquático, verificando-se que a sua remoção nas Estações de Tratamento de Águas Residuais (ETAR) não era completa. Durante as duas últimas décadas foi identificada a presença de mais de oitenta compostos no meio ambiente e actualmente são considerados poluentes emergentes. Podem contaminar solos e águas, depois de serem usados e excretados (inalterados ou metabolizados) por humanos e animais, ou quando são indevidamente lançados directamente no meio ambiente. Os estudos ecotoxicológicos efectuados com estes poluentes têm sido direccionados, sobretudo, para as águas, existindo uma ausência de trabalhos sobre solos. O Ibuprofeno (IB) é um anti-inflamatório não esteróide, utilizado também como analgésico e antipirético, sendo um dos produtos farmacêuticos mais vendidos em todo o mundo, o que justifica a sua forte presença no meio ambiente. Por isso, e dada a ausência de trabalhos ecotoxicológicos de solos contaminados por fármacos, o IB foi o produto farmacêutico selecionado para a realização deste trabalho. A ecotoxicidade pode ser avaliada através de bioensaios. Estes têm a capacidade de avaliar a toxicidade de uma determinada substância de forma global, usando organismos vivos que funcionam como bio-indicadores. O presente trabalho tem como objectivos avaliar o impacte causado nos solos pelo IB, testar a toxicidade de dois processos de descontaminação para remover o referido fármaco dos solos assim como avaliar a toxicidade provocada por águas residuais, de três unidades hospitalares e de uma indústria farmacêutica. Esta avaliação foi efectuada através de ensaios de toxicidade aguda de germinação e de alongamento de raiz de sementes de alface, variedade bola de manteiga (Lactuca sativa), em solo arenoso. Os ensaios de ecotoxicidade aguda em solos contaminados por IB foram realizados para uma gama de concentrações entre 0,1 e 1000 μg/L. Verificou-se uma redução do número de sementes germinadas e do comprimento médio da planta no solo contaminado com 0,5 e 20 μg/L de IB. No solo contaminado com 1000 μg/L de IB observou-se uma redução da germinação, acompanhada por uma indução de crescimento da raiz da espécie Lactuca sativa. Os dois tratamentos de descontaminação de solos, reagente de Fenton e Nanopartículas de ferro zero valente, revelaram toxicidade, tendo-se obtido uma percentagem de germinação entre 32,2 ± 3,5 e 48,5 ± 6,2 e inibição do crescimento da raiz do organismo teste em cerca de 85,0 %. Em relação às águas residuais hospitalares verificou-se uma redução da percentagem de germinação entre 31,1 ± 5,0 e 72,3 ± 12,4 e uma inibição do crescimento da raiz situada entre 13,0 ± 6,4 e 20,2 ± 10,0 %. Para a água residual industrial ocorreu uma inibição da percentagem de germinação de 60,5 ± 13,1, contudo nas plantas germinadas observou-se uma indução do crescimento da raiz de 14,9 ± 7,7 %.
Resumo:
A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to select appropriate oxidizing agents, pH, and concentration ratios of reagents, on the basis of their effect on the stability of the colored complex. Conditions selected as a result of these trials were implemented in a flow-injection analytical system in which the influence of injection volume, flow rate, and reaction- coil length, was evaluated. Under the optimum conditions the total amount of polyphenols, expressed as gallic acid, could be determined within a concentration range of 36 to 544 mg L–1, and with a sensitivity of 344 L mol–1 cm–1 and an RSD <1.1%. The reproducibility of analytical readings was indicative of standard deviations <2%. Interference from sugars, tartaric acid, ascorbic acid, methanol, ammonium sulfate, and potassium chloride was negligible. The proposed system was applied to the determination of total polyphenols in red wines, and enabled analysis of approximately 55 samples h–1. Results were usually precise and accurate; the RSD was <3.9% and relative errors, by the Folin–Ciocalteu method, <5.1%.
Resumo:
O recente surgimento de nanopartículas de ferro valente-zero (nFZV), um material com elevada capacidade de remediação de solos por via de reacções de oxidação/redução pode ser uma opção viável para a remoção de fármacos do solo. A sua aplicação já é uma realidade em alguns tipos de solos contaminados por compostos específicos e, com este trabalho, procura-se estudar a sua capacidade de remediação de solos contaminados por compostos farmacêuticos, recorrendo-se a uma tecnologia “verde” de síntese destas nanopartículas. Esta tecnologia é bastante recente, ainda não aplicada no campo de trabalho, que se baseia no uso de folhas de certas árvores para produzir extratos naturais que reduzem o ferro (III) a ferro zero valente, formando nFZV. Desta forma procedeu-se, à escala laboratorial, ao estudo da eficiência das nFZV na degradação de um fármaco – paracetamol – e comparou-se com a eficiência demonstrada por oxidantes, muito utilizados hoje em dia em casos de remediação in situ como o permanganato de potássio, o peróxido de hidrogénio, o persulfato de sódio e o reagente de Fenton. O estudo foi efectuado em dois meios diferentes: solução aquosa e solo arenoso. De forma muito sucinta, o estudo baseou-se na introdução dos oxidantes/nFZV em soluções/solos contaminados com paracetamol e consequente monitorização do processo de remediação através de cromatografia líquida de alta eficiência. Nos ensaios com soluções aquosas contaminadas com paracetamol, o permanganato de potássio e o reagente de Fenton revelaram capacidade para degradar o paracetamol, atingindo mesmo um grau de degradação de 100%. O persulfato de sódio também demonstrou uma capacidade de degradação do paracetamol, chegando a atingir 99% de degradação, mas apenas recorrendo ao uso de um volume de oxidante elevado quando comparado com os outros dois oxidantes já referidos. Por outro lado, o peróxido de hidrogénio não demonstrou qualquer capacidade de degradação do paracetamol, pelo que o seu uso não passou desta fase. Verificou-se também que o uso de ferro granulado para o tratamento de água contaminada com paracetamol revelou resultados diferentes dos observados no uso de nFZV, obtendo-se eficiências de 87%. Existiram dificuldades analíticas na quantificação do paracetamol, especificamente relacionadas com o uso do extracto de folhas de amoreira, cuja composição continha substâncias que causaram dificuldades acentuadas na análise dos cromatogramas. Por fim, um pequeno teste de combinação do reagente de Fenton com os fenómenos de biodegradação resultantes dos microrganismos presentes em folhas do extracto de chá preto demonstrou que este pode ser uma área que pode e deve ser mais estudada. Desta forma, a utilização das nFZV para o tratamento de água contaminada com paracetamol não permitiu a retirada de conclusões seguras sobre a capacidade que as nFZV produzidas com extractos de folhas de amoreira e de chá preto têm de degradação do paracetamol. Nos testes de remediação de solos contaminados os resultados demonstraram que, mais uma vez, tanto o permanganato de potássio como o reagente de Fenton se revelam como os melhores oxidantes para a degradação do paracetamol, obtendo-se a degradação total do paracetamol. Por outro lado, voltou a ser necessário uma elevada quantidade de persulfato de sódio quando comparada com os dois anteriores, para que ocorra a degradação desta mesma quantidade de paracetamol, demonstrando mais uma vez que, apesar de não ideal, o persulfato demonstra capacidade de degradação do paracetamol.
Resumo:
The wide use of antibiotics in aquaculture has led to the emergence of resistant microbial species. It should be avoided/minimized by controlling the amount of drug employed in fish farming. For this purpose, the present work proposes test-strip papers aiming at the detection/semi-quantitative determination of organic drugs by visual comparison of color changes, in a similar analytical procedure to that of pH monitoring by universal pH paper. This is done by establishing suitable chemical changes upon cellulose, attributing the paper the ability to react with the organic drug and to produce a color change. Quantitative data is also enabled by taking a picture and applying a suitable mathematical treatment to the color coordinates given by the HSL system used by windows. As proof of concept, this approach was applied to oxytetracycline (OXY), one of the antibiotics frequently used in aquaculture. A bottom-up modification of paper was established, starting by the reaction of the glucose moieties on the paper with 3-triethoxysilylpropylamine (APTES). The so-formed amine layer allowed binding to a metal ion by coordination chemistry, while the metal ion reacted after with the drug to produce a colored compound. The most suitable metals to carry out such modification were selected by bulk studies, and the several stages of the paper modification were optimized to produce an intense color change against the concentration of the drug. The paper strips were applied to the analysis of spiked environmental water, allowing a quantitative determination for OXY concentrations as low as 30 ng/mL. In general, this work provided a simple, method to screen and discriminate tetracycline drugs, in aquaculture, being a promising tool for local, quick and cheap monitoring of drugs.
Resumo:
Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.
Resumo:
A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
A indústria de componentes para automóveis necessita de constante inovação, no sentido de manter a elevada competitividade, imprescindível à sobrevivência de qualquer empresa neste sector. A automação e robótica são vias incontornáveis para a prossecução dos objetivos de produtividade desejados. Mesmo dentro da automação, a evolução é constante. Para além disso, a crescente inovação nos produtos fabricados, exige também novas soluções em termos de processos de fabrico. Isto leva a que, soluções válidas até uma determinada altura, passem facilmente a obsoletas, com necessidade premente de se implementarem novos sistemas que correspondam às necessidades atuais. Este trabalho teve por base uma necessidade detetada numa empresa fabricante de acessórios para a indústria automóvel: estruturas para estofo de assento automóvel, entre muitos outros. Atualmente, a estrutura do estofo automóvel assenta numa grelha constituída por um conjunto de arames, que é agregado por uma série de tiras de plástico injetadas em seu redor. As máquinas de injeção responsáveis por este processo têm superfície de apartação horizontal, e necessitam de mão-de-obra adjacente para a colocação dos arames no molde e descarga do conjunto, na razão de uma pessoa para duas máquinas, dependendo do tempo de ciclo da injeção. O trabalho consistiu no desenvolvimento de um sistema automático de alimentação e descarga da máquina de injeção, que tivesse por base um sistema já existente, mas que passasse a comportar outras funções até agora não desempenhadas pelos sistemas antigos, ou seja, que fossem capazes de ultrapassar os problemas colocados pela complexidade atual dos produtos em fabricação. O projeto foi concluído com sucesso, tendo sido validado pela empresa FicoCables, através da construção, teste e colocação em funcionamento de vários protótipos.