18 resultados para Pollutant dispersions
em Instituto Politécnico do Porto, Portugal
Resumo:
The objectives of this work were: (1) to identify an isotherm model to relate the contaminant contents in the gas phase with those in the solid and non-aqueous liquid phases; (2) to develop a methodology for the estimation of the contaminant distribution in the different phases of the soil; and (3) to evaluate the influence of soil water content on the contaminant distribution in soil. For sandy soils with negligible contents of clay and natural organic matter, contaminated with benzene, toluene, ethylbenzene, xylene, trichloroethylene (TCE), and perchloroethylene (PCE), it was concluded that: (1) Freundlich’s model showed to be adequate to relate the contaminant contents in the gas phase with those in the solid and non-aqueous liquid phases; (2) the distribution of the contaminants in the different phases present in the soil could be estimated with differences lower than 10% for 83% of the cases; and (3) an increase of the soil water content led to a decrease of the amount of contaminant in the solid and non-aqueous liquid phases, increasing the amount in the other phases.
Resumo:
Background: The role of persistent organic pollutants (POPs) with endocrine disrupting activity in the aetiology of obesity and other metabolic dysfunctions has been recently highlighted. Adipose tissue (AT) is a common site of POPs accumulation where they can induce adverse effects on human health. Objectives: To evaluate the presence of POPs in human visceral (vAT) and subcutaneous (scAT) adipose tissue in a sample of Portuguese obese patients that underwent bariatric surgery, and assess their putative association with metabolic disruption preoperatively, as well as with subsequent body mass index (BMI) reduction. Methods: AT samples (n=189) from obese patients (BMI ≥35) were collected and the levels of 13 POPs were determined by gas chromatography with electron-capture detection (GC-ECD). Anthropometric and biochemical data were collected at the time of surgery. BMI variation was evaluated after 12 months and adipocyte size was measured in AT samples. Results: Our data confirm that POPs are pervasive in this obese population (96.3% of detection on both tissues), their abundance increasing with age (RS=0.310, p<0.01) and duration of obesity (RS=0.170, p<0.05). We observed a difference in AT depot POPs storage capability, with higher levels of ΣPOPs in vAT (213.9±204.2 compared to 155.1±147.4 ng/g of fat, p<0.001), extremely relevant when evaluating their metabolic impact. Furthermore, there was a positive correlation between POP levels and the presence of metabolic syndrome components, namely dysglycaemia and hypertension, and more importantly with cardiovascular risk (RS=0.277, p<0.01), with relevance for vAT (RS=0.315, p<0.01). Finally, we observed an interesting relation of higher POP levels with lower weight loss in older patients. Conclusion: Our sample of obese subjects allowed us to highlight the importance of POPs stored in AT on the development of metabolic dysfunction in a context of obesity, shifting the focus to their metabolic effects and not only for their recognition as environmental obesogens.
Resumo:
Mestrado em Engenharia Química
Resumo:
Mestrado em Engenharia Química.Ramo Tecnologias de Protecção Ambiental
Resumo:
O meio ambiente é uma grande preocupação mundial existindo cada vez mais imposições legais no sentido de o proteger. Torna-se assim necessário que as indústrias adoptem e desenvolvam processos alternativos mais limpos. A indústria de curtumes transforma a pele animal em couro, material resistente à putrefacção e com estabilidade térmica suficiente para ser manufacturado nas indústrias do calçado, estofos, vestuário e marroquinaria. A transformação referida é efectuada através duma série de processos entre os quais o caleiro, processo que visa depilar a pele e promover o relaxamento da estrutura fibrilar, tem um papel importante. O processo de caleiro produz um efluente bastante poluente. Tendo em conta esse facto, este trabalho teve como objectivo desenvolver processos de depilação de pele caprina sem destruição do pêlo, com vista à redução da quantidade de sulfureto e sulfidrato de sódio utilizada e da carga poluente do efluente. Além disso, o processo permite a recuperação do pêlo e este pode ser reaproveitado como fertilizante orgânico, hidrolisado de queratina, compostagem, etc. Todo o trabalho foi realizado tomando por base um processo de caleiro padrão utilizado industrialmente, alterando-o de forma a obter um processo de caleiro óptimo de depilação sem destruição do pêlo com e sem utilização de enzimas. Numa primeira fase, desenvolveu-se um processo de depilação sem destruição do pêlo normalmente utilizado para a pele de bovino que foi adaptado com resultados positivos, designado de processo sem enzimas. Numa segunda fase, desenvolveu-se um processo enzimático em que se utilizou uma protease (Erhavit DMC), uma lipase (Defat 50) e uma amilase (Mayzme SD-L); este processo deu bons resultados tal como o anterior. A redução da quantidade de sulfureto de sódio foi de 33% e 53% para o processo sem enzimas e processo com enzimas, respectivamente, em relação ao processo padrão. O efeito dos processos na carga poluente, à escala piloto, comprova uma redução de 37% nos SST, 37% nos SDT, 60% na CQO, 9% no S2- e 73% no Azoto para o processo sem enzimas e uma redução de 93% nos SST, 63% nos SDT, 69% na CQO, 69% no S2- e 83% no Azoto para o processo com enzimas, quando comparados com o processo padrão. . Uma análise de custos, com incidência apenas nos agentes químicos utilizados, permitiu concluir a existência de uma redução de custos anuais de 30% para o processo com enzimas e de 13% para o processo sem enzimas, quando comparados com o processo padrão. Como conclusão, os processos desenvolvidos apresentam um grande potencial para serem explorados industrialmente.
Resumo:
Este trabalho na área dos processos físicos de separação por membranas, nomeadamente, a nanofiltração (NF), tem como objectivo principal a recuperação dos efluentes resultantes das águas da 3ª lavagem utilizadas na operação de tingimento de fibras de algodão, com corantes reactivos. Estão inerentes as problemáticas: da escassez da água como matéria-prima na vertente de água potável; da diminuição de efluentes que necessitam de tratamentos devido à sua carga poluente; da recuperação sempre que seja viável dos produtos químicos adicionados nesta fase de tratamento das fibras de algodão e por último e não menos importante, da energia contida nestes efluentes que vão para o esgoto a temperaturas na ordem dos 50 ºC. A metodologia adoptada na realização deste trabalho consistiu, inicialmente num estudo sobre os trabalhos realizados até hoje nesta área, seguindo-se a recolha dos efluentes na empresa ―Estamparia Têxtil Adalberto Pinto da Silva, S.A.‖ (ETAPS) e posterior estudo da recuperação dos efluentes em causa pelo processo de NF utilizando a membrana NF270-2540 da empresa FILMTEC. Os efluentes estudados no presente trabalho continham corantes reactivos sendo um corante azul-claro (CAC) de composição (Amarelo Bril Remazol GL 150% + Azul Brilhante Remazol BB 133% + Azul Turqueza Remazol G) e o outro corante azul-marinho (CAM) de composição (Preto Remazol B 133% + Vermelho Remazol RGB + Amarelo Ouro Remazol RGB). Estes estudos de recuperação compreenderam basicamente 3 fases: caracterização do efluente recolhido na empresa; tratamento desse efluente utilizando uma instalação piloto de NF de fluxo cruzado ou também conhecido por membrana de fluxo tangencial instalado no Laboratório de Tecnologia (LT) do Instituto Superior de Engenharia do Porto (ISEP), e caracterização dos permeados e dos rejeitados obtidos. A análise de resultados do presente trabalho permitiu concluir ser possível a recuperação e reutilização das 3ª águas de lavagem do processo de tingimento quando tratadas pelo processo de NF a pressões de operação de 6 bar. Nestas circunstâncias os permeados obtidos (tanto no efluente com corante azul-claro como no efluente com corante azul-marinho) apresentam valores, em todos os parâmetros estudados, significativamente abaixo dos valores limites recomendáveis para uma água de abastecimento na Industria Têxtil (IT). Salienta-se reduções mais expressivas nos permeados do corante CAM, com vários parâmetros a sofrerem reduções no intervalo de 98 a 100%, nomeadamente, na cor, turvação, CQO, dureza total, alumínio e manganês. Os resultados obtidos para as pressões de operação de 4 e 8 bar mostram alguns parâmetros com valores acima dos recomendados para uma água de abastecimento na Indústria Têxtil, nomeadamente a cor no corante CAC quando se opera a 4 bar e no corante CAM quando se opera a 8 bar e os sulfatos e ferro no CAM à pressão de 4 bar. Estes resultados mostram ser possível a reutilização da água na própria instalação industrial, trazendo um benefício económico e ambiental, pela redução no consumo de água fresca e energia, além da redução do volume de efluentes que necessitam ser tratados, estando na mesma linha de pensamento de Gross et al (1999), que refere que o uso de membranas para o tratamento de efluentes do processo de tingimento tem como principal objectivo a viabilidade económica, a redução no consumo de água, de sais, de corantes e energia, bem como, a redução do volume de efluentes a ser tratado.
Resumo:
A procura de uma forma limpa de combustível, aliada à crescente instabilidade de preços dos combustíveis fósseis verificada nos mercados faz com que o hidrogénio se torne num combustível a considerar devido a não resultar qualquer produto poluente da sua queima e de se poder utilizar, por exemplo, desperdícios florestais cujo valor de mercado não está inflacionado por não pertencer à cadeia alimentar humana. Este trabalho tem como objetivo simular o processo de gasificação de biomassa para produção de hidrogénio utilizando um gasificador de leito fluidizado circulante. O oxigénio e vapor de água funcionam como agentes gasificantes. Para o efeito usou-se o simulador de processos químicos ASPEN Plus. A simulação desenvolvida compreende três etapas que ocorrem no interior do gasificador: pirólise, que foi simulada por um bloco RYIELD, combustão de parte dos compostos voláteis, simulada por um bloco RSTOIC e, por fim, as reações de oxidação e gasificação do carbonizado “char”, simuladas por um bloco RPLUG. Os valores de rendimento dos compostos após a pirólise, obtidos por uma correlação proposta por Gomez-Barea, et al. (2010), foram os seguintes: 20,33% “char”, 22,59% alcatrão, 36,90% monóxido de carbono, 16,05%m/m dióxido de carbono, 3,33% metano e 0,79% hidrogénio (% em massa). Como não foi possível encontrar valores da variação da composição do gás à saída do gasificador com a variação da temperatura, para o caso de vapor de água e oxigénio, optou-se por utilizar apenas vapor na simulação de forma a comparar os seus valores com os da literatura. Às temperaturas de 700, 770 e 820ºC, para um “steam-to-biomass ratio”, (SBR) igual a 0,5, os valores da percentagem molar de monóxido de carbono foram, respetivamente, 56,60%, 55,84% e 53,85%, os valores de hidrogénio foram, respetivamente, 17,83%, 18,25% e 19,31%, os valores de dióxido de carbono foram, respetivamente, 16,40%, 16,85% e 17,93% e os valores de metano foram, respetivamente, 9,00%, 8,95% e 8,83%. Os valores da composição à saída do gasificador, à temperatura de 820ºC, para um SBR de 0,5 foram: 53,85% de monóxido de carbono, 19,31% de hidrogénio, 17,93% de dióxido de carbono e 8,83% de metano (% em moles). Para um SBR de 0,7 a composição à saída foi de 54,45% de monóxido de carbono, 19,01% de hidrogénio, 17,59% de dióxido de carbono e 8,87% de metano. Por fim, quando SBR foi igual a 1 a composição do gás à saída foi de 55,08% de monóxido de carbono, 18,69% de hidrogénio, 17,24% de dióxido de carbono e 8,90% de metano. Os valores da composição obtidos através da simulação, para uma mistura de ar e vapor de água, ER igual a 0,26 e SBR igual a 1, foram: 34,00% de monóxido de carbono, 14,65% de hidrogénio, 45,81% de dióxido de carbono e 5,41% de metano. A simulação permitiu-nos ainda dimensionar o gasificador e determinar alguns parâmetros hidrodinâmicos do gasificador, considerando que a reação “water-gas shift” era a limitante, e que se pretendia obter uma conversão de 95%. A velocidade de operação do gasificador foi de 4,7m/s e a sua altura igual a 0,73m, para um diâmetro de 0,20m.
Resumo:
O rio Febros é um pequeno curso de água, situado no concelho de Vila Nova de Gaia, com cerca de 15 km de extensão, cuja bacia hidrográfica ocupa uma área de aproximadamente 35,4 km2. Nasce em Seixezelo e desagua na margem esquerda do Rio Douro no Cais do Esteiro, em Avintes. Em Maio de 2008, um acidente de viação teve como consequência o derrame de cerca de quatro toneladas de ácido clorídrico que rapidamente convergiu às águas do rio. Apenas um dia depois, o pH desceu para três e muitos foram os peixes que morreram. A solução adoptada para evitar o desaire foi introduzir milhares de litros de água de modo a diluir o ácido presente, ao longo de todo o curso de água. Tal facto não evitou a destruição de parte de um ecossistema, que ainda nos dias de hoje se encontra em recuperação. De forma a avaliar-se o impacto destas possíveis perturbações sejam estas de origem antropogénica ou natural é necessário possuir conhecimentos dos processos químicos tais como a advecção, a mistura devida à dispersão e a transferência de massa ar/água. Estes processos irão determinar o movimento e destino das substâncias que poderão ser descarregadas no rio. Para tal, recorrer-se-á ao estudo hidrogeométrico do curso de água assim como ao estudo do comportamento de um marcador, simulando uma possível descarga. A rodamina WT será o marcador a ser utilizado devido à panóplia de características ambientalmente favoráveis. Os estudos de campo com este corante, realizados em sequência de descarga previamente estudada, fornecem uma das melhores fontes de informação para verificação e validação de modelos hidráulicos utilizados em estudos de qualidade de águas e protecção ambiental. Escolheram-se dois pontos de descarga no Febros, um em Casal Drijo e outro no Parque Biológico de Gaia, possuindo cada um deles, a jusante, duas estações de monitorização. Pelo modelo ADE os valores obtidos para o coeficiente de dispersão longitudinal para as estações Pontão d’ Alheira, Pinheiral, Menesas e Giestas foram, respectivamente, 0,3622; 0,5468; 1,6832 e 1,7504 m2/s. Para a mesma sequência de estações, os valores da velocidade de escoamento obtidos neste trabalho experimental foram de 0,0633; 0,0684; 0,1548 e 0,1645 m/s. Quanto ao modelo TS, os valores obtidos para o coeficiente de dispersão longitudinal para as estações Pontão d’ Alheira, Pinheiral, Menesas e Giestas foram, respectivamente, 0,2339; 0,1618; 0,5057e 1,1320 m2/s. Para a mesma sequência de estações, os valores da velocidade de escoamento obtidos neste trabalho experimental foram de 0,0652; 0,0775; 0,1891 e 0,1676 m/s. Os resultados foram ajustados por um método directo, o método dos momentos, e por dois métodos indirectos, os modelos ADE e TS. O melhor ajuste corresponde ao modelo TS onde os valores do coeficiente de dispersão longitudinal e da velocidade de escoamento são aqueles que melhor se aproximam da realidade. Quanto ao método dos momentos, o valor estimado para a velocidade é de 0,162 m/s e para o coeficiente de dispersão longitudinal de 9,769 m2/s. Não obstante, a compreensão da hidrodinâmica do rio e das suas características, bem como a adequação de modelos matemáticos no tratamento de resultados formam uma estratégia de protecção ambiental inerente a futuros impactos que possam suceder.
Resumo:
O consumo de energia a nível mundial tem atingido valores históricos, devido ao crescimento da população mundial e ao aumento do consumo per capita. Nesta medida é extremamente importante existirem alternativas para que a redução do consumo de energia de todos os países seja uma realidade, evitando também as consequências ambientais, em particular as alterações climáticas, resultantes da utilização intensiva de combustíveis fósseis. Portugal, tal como outros países da União Europeia, tem que cumprir metas, pelo que é urgente encontrarem-se soluções de forma a diminuir o consumo de energia sem interferir com o nosso dia-a-dia. A cidade do Porto, tal como qualquer cidade, precisa de imensa energia desde os transportes até à indústria, passando pelos edifícios. Os edifícios, residenciais e de serviços, são responsáveis por mais de 50% de energia primária consumida no concelho do Porto, sendo que aos edifícios residenciais corresponde um consumo de 1.473 GWh/ano de energia primária, o que é um valor elevado. Numa primeira parte deste trabalho foi efetuado um levantamento de informação caracterizando a cidade do Porto relativamente ao seu edificado e consumos energéticos. Numa segunda parte propuseram-se medidas para reduzir o consumo para cada tipo de utilização de energia, nomeadamente preparação de refeições, AQS (água quente sanitária), aquecimento ambiente, frio (frigorífico, arcas, etc.), outros e iluminação. Para cada um destes tipos de utilização estudou-se, sempre que possível, a evolução do longo do tempo (2004 a 2012) e possíveis cenários de evolução para o futuro. Para além disso, também se estudou a evolução do mix de produção de energia elétrica de 2004 até 2012 e previsões da evolução do mix para o futuro. Nesta análise foi tido em conta o aspeto ambiental contabilizando-se, sempre que possível, as emissões de poluentes resultantes do consumo de energia. Por fim, efetuou-se uma avaliação técnica, ambiental e económica das medidas propostas. Pode dizer-se que a maioria das medidas propostas a serem implementadas conduziria a uma redução do consumo de energia e consequentemente a uma diminuição das emissões de poluentes, em particular dos gases com efeito de estufa (CO2). Em termos técnicos a maioria das medidas pode ser aplicada embora algumas delas envolvam custos de investimento significativos. Dada a conjuntura atual, seria importante obter o financiamento necessário para a implementação das medidas propostas e a divulgação de medidas já existentes, tais como os programas para AQS e janelas eficientes.
Resumo:
Lead is an important environmental pollutant. The role of vacuole, in Pb detoxification, was studied using a vacuolar protein sorting mutant strain (vps16D), belonging to class C mutants. Cells disrupted in VPS16 gene, did not display a detectable vacuolar-like structure. Based on the loss of cell proliferation capacity, it was found that cells from vps16D mutant exhibited a hypersensitivity to Pb-induced toxicity, compared to wild type (WT) strain. The function of vacuolar H?-ATPase (VATPase), in Pb detoxification, was evaluated using mutants with structurally normal vacuoles but defective in subunits of catalytic (vma1D or vma2D) or membrane domain (vph1D or vma3D) of V-ATPase. All mutants tested, lacking a functional V-ATPase, displayed an increased susceptibility to Pb, comparatively to cells from WT strain. Modification of vacuolar morphology, in Pb-exposed cells, was visualized using a Vma2p-GFP strain. The treatment of yeast cells with Pb originated the fusion of the medium size vacuolar lobes into one enlarged vacuole. In conclusion, it was found that vacuole plays an important role in the detoxification of Pb in Saccharomyces cerevisiae; in addition, a functional V-ATPase was required for Pb compartmentalization.
Resumo:
A crescente expansão urbana e o incremento das exigências ambientais e financeiras promovem a implementação de abordagens sustentáveis para a gestão das infraestruturas sanitárias. Assim, o recurso a instrumentos de monitorização e à modelação matemática surge como o caminho para a racionalização do investimento e a otimização dos sistemas existentes. Neste contexto, a modelação dinâmica de sistemas de drenagem urbana assume relevância para o controlo e redução dos caudais em excesso e das descargas de poluentes nos meios recetores, resultantes de um incremento significativo de afluências pluviais indevidas, de problemas de sub-dimensionamento ou falta de operação e manutenção. O objetivo da presente dissertação consiste na modelação, calibração e diagnóstico do sistema intercetor de Lordelo utilizando o software Storm Water Management Model, através dos dados recolhidos a partir do projeto de Reabilitação dos intercetores de Lordelo, elaborado pela Noraqua. A modelação considera a avaliação das afluências de tempo seco e as afluências pluviais pelo software Sanitary Sewer Overflow Analysis and Planning Toolbox. Com efeito, a simulação dinâmica, permitiu um conhecimento mais detalhado do sistema, avaliando a capacidade hidráulica e localizando os pontos propícios a inundações. Assim, foi possível testar soluções de beneficiação do sistema, englobando a problemática das afluências pluviais indevidas calibradas. Apesar das dificuldades sentidas face à qualidade dos dados existentes, verificou-se que o SSOAP e o SWMM são ferramentas úteis na deteção, diagnóstico e redução dos caudais em excesso e que o procedimento utilizado pode ser aplicado a sistemas semelhantes, como forma de definir a melhor solução técnica e económica ao nível do planeamento, operação e reabilitação do sistema.
Resumo:
A presença de metais pesados no meio ambiente deve-se, principalmente, a actividades antropogénicas. Ao contrário do Cu e do Zn, que em baixas concentrações são essenciais para o normal funcionamento celular, não se conhece para o chumbo nenhuma função biológica. O chumbo apresenta efeitos tóxicos, e considerado possível agente carcinogéneo, sendo classificado como poluente prioritário pela Agencia de Protecção Ambiental dos EUA (US-EPA). O presente trabalho teve como objetivo avaliar o papel da glutationa e do vacúolo, como mecanismos de defesa, contra os efeitos tóxicos induzidos pelo chumbo, usando como modelo a levedura Saccharomyces cerevisiae. A levedura S. cerevisiae quando exposta a varias concentrações de chumbo, durante 3h, perde a viabilidade e acumula espécies reativas de oxigénio (ROS). O estudo comparativo da perda de viabilidade e acumulação de ROS em células de uma estirpe selvagem (WT) e de estirpes mutantes, incapazes de produzir glutationa devido a uma deficiência no gene GSH1 (gsh1) ou GSH2 (gsh2) mostrou que as estirpes gsh1 ou(gsh2 não apresentavam um aumento da sensibilidade ao efeito toxico do chumbo. No entanto, o tratamento de células da estirpe WT com iodoacetamida (um agente alquilante que induz a depleção de glutationa) aumentou a sensibilidade das células a presença de chumbo. Pelo contrário, o enriquecimento em GSH, através da incubação de células WT com glucose e uma mistura de aminoácidos que constituem a GSH (acido L-glutâmico, L-cisteína e glicina), reduziu o stress oxidativo e a perda de viabilidade induzida por chumbo. A importância do vacúolo, como mecanismo de defesa, foi avaliada através da utilização de um mutante sem qualquer estrutura vacuolar (vps16) ou de mutantes deficientes na subunidade catalítica A (vma1) ou B (vma2) ou no proteolítico - subunidade C (vma3) da V-ATPase. As células da estirpe ƒ´vps16 apresentaram uma elevada suscetibilidade a presença de chumbo. As células das estirpes deficientes na subunidade A, B ou c da V-ATPase, apresentaram uma maior perda de viabilidade, quando expostas a chumbo, do que as células da estirpe WT, mas menor do que a da estirpe vps16 Em conclusão, os resultados obtidos, no seu conjunto, sugerem que a glutationa esta envolvida na defesa contra a toxicidade provocada por chumbo; todavia, a glutationa, por si só, parece não ser suficiente para suster o stress oxidativo e a perda de viabilidade induzida por chumbo. O vacúolo parece constituir um importante mecanismo de defesa contra a toxicidade provocada por chumbo. A V-ATPase parece estar envolvida na compartimentação de chumbo no vacúolo.
Resumo:
A manutenção, durante vários anos, traduziu-se num conceito paliativo de instalações e equipamentos, o que se veio a revelar como uma atitude negligente perante o Homem e o Ambiente. As preocupações ambientais estão na ordem do dia e têm sido muitas as vozes que se têm levantado para que o consumo de energia seja mais equilibrado e para que as emissões de CO2 diminuam de forma a preservar o Planeta. De acordo com a resolução do Conselho Europeu, em 2007 (1), foi apresentado um pacote de propostas que visam a sustentabilidade e estimulam a Eficiência Energética (EE), com o objectivo de reduzir os consumos energéticos dos edifícios, quer estes sejam novos ou reabilitados. Segundo a Direcção Geral de Energia e Geologia os edifícios são responsáveis por 60% dos consumos de energia eléctrica, consumo esse que pode ser reduzido em mais de 50%, através de medidas de EE, traduzindo-se numa redução de 400 milhões de toneladas de CO2 por ano. (2) Para além de medidas de EE, também as práticas de manutenção preventiva podem contribuir para a diminuição dos consumos energéticos e de emissões de CO2. Segundo o Institute for Building Efficiency práticas de manutenção preventiva em equipamentos de Aquecimento Ventilação e Ar Condicionado (AVAC) reduzem os consumos energéticos de 10 a 20% e, em contrapartida, a negligência na execução da manutenção pode aumentar os consumos energéticos de 30 a 60%. (3) Uma outra análise de valores a ter em conta, é a Intensidade Energética (IE). Leia-se IE como sendo o valor global da energia consumida num país a dividir pelo seu produto interno bruto. A contribuição do sector dos serviços para a IE nacional era de 17% no ano de 2005. (4) Se a estes dados acrescentarmos que 70% dessa energia é consumida por equipamentos AVAC (5) e que práticas de manutenção reduzem esses valores entre 10 a 20%, pode concluir-se que a redução de custos energéticos associada à manutenção preventiva é efectiva e significativa. Apresentando um cenário ideal e hipotético, se ao contributo do sector dos serviços, para a IE nacional, se isolar o valor referente a equipamentos de AVAC, obtem-se uma IE de aproximadamente 12%. Se adicionalmente se considerar uma taxa de redução, relativa à execução da manutenção, entre 10 e 20%, Portugal obteria uma IE, relativamente aos consumos energéticos em edificios de serviços, não de 17% mas sim entre 14,6% e 15,8%. Neste trabalho pretende-se comprovar que um plano de actividades de manutenção equilibrado, monitorizado, e gerido de forma eficaz e funcional, é uma ferramenta fundamental no cumprimento de objectivos e metas europeias traçadas, que se reúnem num objectivo comum de preservação do planeta. A adopção deste tipo de medidas contribuirá para a racionalização dos consumos energéticos e para o aumento da vida útil dos equipamentos, bem como para a melhoria do desempenho económico e financeiro das organizações, tal como se poderá ler mais à frente neste trabalho. Será também analisado um caso prático, verificando a eficácia das medidas tomadas durante as intervenções preventivas de manutenção, sendo que para isso será estudado o comportamento de um equipamento, antes e após a realização de tarefas de manutenção preventiva. Tentar-se-á, junto de gestores de edifícios, recolher a opinião que têm sobre a importância da manutenção. Ao longo de toda a pesquisa foi possível consolidar a hipótese formulada inicialmente no que concerne ao contributo da manutenção para a sustentabilidade, quer através da revisão da literatura, quer nos testes efectuados a equipamentos. Foi possível confirmar que um plano de manutenção ajustado, monitorizado e cumprido é uma ferramenta na diminuição dos consumos energéticos, aumento da vida útil de equipamentos e por sua vez na diminuição de emissões de CO2. Verificou-se também que o controlo de poluentes e ventilação adequada dos edifícios são uma ferramenta essencial para a qualidade do ar interior, parâmetros facilmente controlados nas actividades de manutenção. O contributo das opiniões recolhidas entre os gestores de edifícios, para este estudo, foi também bastante importante, uma vez que todos eles reconhecem o papel importante da manutenção, mas nem todos estão sensibilizados para o seu papel na sustentabilidade do planeta. Nesta dissertação é deixado um alerta: o crescimento da população mundial e a consequente utilização de recursos naturais que são finitos, não sendo controlado de uma forma sustentada, pode resultar na destruição de um planeta único. O papel negativo do Homem nas alterações climáticas é inequívoco e é necessário melhorar a sua relação com o Ambiente. Cada ser humano está inserido na sua comunidade e dentro dela tem a sua função, cabe a cada um exercer esta responsabilidade nas suas actividades do dia-a-dia.
Resumo:
A água é um recurso natural único, escasso e essencial a todos os seres vivos, o que a torna um bem de extrema importância. Nos dias de hoje, o desperdício deste bem, aliado ao aumento da sua procura, tornou-se um problema devido à decrescente disponibilidade de água doce no nosso planeta. Todas as águas que rejeitamos depois da sua utilização para diversos fins, designadas de águas residuais, necessitam de tratamento antes de serem devolvidas ao meio ambiente. O seu tratamento é realizado numa Estação de Tratamento de Águas Residuais (ETAR) e o processo de tratamento depende das suas características. A ETAR das Termas de S. Vicente, em Penafiel, trabalha no seu limite de capacidade, apresenta uma sobrecarga hidráulica gerada por uma afluência de águas pluviais e o processamento das lamas geradas não permite uma secagem tão completa como seria desejável. Assim, este trabalho teve como objetivo o estudo do funcionamento desta ETAR com a finalidade de propor soluções que o possam otimizar. As soluções propostas para otimizar o funcionamento da ETAR em estudo são: i) a substituição de grades de limpeza manual por grades de limpeza automática de forma a reduzir a necessidade da intervenção do operador ao nível da remoção e condicionamento dos gradados; ii) a construção de um desarenador arejado que além de remover areias de diâmetro superior a 0,2 mm promove também a remoção de gorduras, protegendo desta forma os equipamentos a jusante da abrasão/desgaste prematuros e reduzindo a formação de depósitos nas tubagens; iii) a construção de um tanque de equalização de forma a garantir uma distribuição mais uniforme dos caudais e da carga poluente; iv) a substituição do enchimento do leito percolador por um meio de suporte plástico que permite atingir melhores eficiências de remoção neste tratamento biológico; v) a alteração do agente de desinfeção para radiação ultravioleta, evitando a adição de produtos químicos na água residual e possível formação de subprodutos prejudiciais ao ambiente, como ocorreria no caso da cloragem; e vi) a substituição da desidratação de lamas em leitos de secagem por filtros de banda, que é um processo mais rápido, que ocupa menos espaço e permite atingir elevadas eficiências de remoção de humidade. Para cada uma das sugestões são apresentadas as correspondentes especificações técnicas e dimensionamento. As sugestões de melhoria apresentadas neste trabalho constituem uma alternativa mais económica do que a ampliação da ETAR, que genericamente corresponde à duplicação da linha de tratamento atual. Devido à menor complexidade em termos de construção, estas sugestões podem vir a ser implementadas num futuro próximo, prolongando assim um pouco mais a vida útil da ETAR atual.
Resumo:
Um dos objetivos desta dissertação de mestrado foi avaliar o impacto ambiental do processo de tingimento usado na indústria de curtumes, em termos de volume de efluente produzido e sua carga poluente. Pretendeu-se também encontrar alternativas ao nível do processo de tingimento que levem a uma melhoria na qualidade do efluente produzido. Outro objetivo deste trabalho foi avaliar o funcionamento da ETAR existente na empresa JR Fontes, no que diz respeito aos parâmetros em estudo (carência química de oxigénio - CQO, pH, crómio e teor de sólidos suspensos totais - SST), propondo alterações que permitam respeitar os valores de emissão exigidos na licença de descarga da empresa. Verificou-se que o processo de tingimento aplicado pela empresa JR Fontes é muito poluente, em termos de carga orgânica e matéria em suspensão. Este facto é comprovado pelos resultados obtidos para os três processos estudados: Montana, Galáctico e Navak. Todos os processos apresentam um efluente com pH ácido (aproximado a 3) e valores de CQO superiores a 3550 mg O2/L, sendo o processo Navak aquele que apresenta o valor mais alto para o banho composto, 8362 mg O2/L. Relativamente ao teor de crómio, o banho de recurtume com concentração mais elevada de crómio total é o banho 1 do processo Navak, com 2297 mg/L, sendo que a concentração destes banhos é sempre elevada, igual ou superior a 746 mg/L. No que diz respeito à matéria em suspensão, o processo Navak é novamente o mais poluente, com um valor de 3842 mg SST/L, não sendo obtidos nos outros processos, valores inferiores a 1205 mg SST/L. Na realização de um processo alternativo de tingimento verificou-se que é possível diminuir a carga orgânica do efluente originado. A aplicação de recurtumes sintéticos deu origem a efluentes menos poluentes. O melhor valor obtido para a CQO foi de 1113 mg O2/L, sendo obtidos valores não superiores a 7185 mg O2/L para processos de características semelhantes aos aplicados nesta indústria. Relativamente à ETAR, apesar das restrições ao funcionamento que esta apresenta, no geral pode ser considerada eficiente, embora não consiga atingir o objetivo pretendido de remoção para a CQO, ou seja o valor de 1100 mg O2/L. Nos restantes parâmetros é cumprido o limite de emissão (350 mg SST/L, pH entre 6 e 9 e 2 mg Cr/L para o crómio total): os SST apresentam o valor de 98 mg SST/L, o crómio total de 1,2 mg Cr/L e o pH encontra-se entre 8 e 9. São aqui feitas duas abordagens para solucionar os problemas existentes na ETAR. A primeira considera um ajuste no tratamento e equipamentos existentes, através da reconstrução do tanque de equalização, da substituição do coagulante por sulfato ferroso e da reconstrução do sedimentador, assim como a substituição das tubagens por umas de maior diâmetro, solucionando assim problemas de manutenção de toda a instalação e do incumprimento da legislação. A outra abordagem implica a substituição do sistema de afinação existente, os filtros de areia e carvão ativados, por um sistema de membranas de ultrafiltração ou por dois filtros de carvão ativado. Para tratar um efluente com um valor de CQO de 3000 mg O2/L com o carvão estudado, seriam necessários 132 kg de carvão por coluna, aproveitando-se os equipamentos existentes. No caso das membranas filtrantes, estas são eficazes, reduzindo a CQO em cerca de 70%. Ao contrário do carvão, a aplicação deste sistema implicaria a aquisição de novos equipamentos. Futuramente propõe-se a avaliação dos vários tipos de reagentes usados no tingimento de couro de forma a aplicar no tratamento aqueles que produzam as características desejadas no produto final e a que apresentem um menor resultado de CQO. Propõe-se também o estudo de viabilidade da remoção de crómio dos banhos de recurtume e consequente avaliação da aplicabilidade de um tratamento biológico em substituição ou como complemento do tratamento existente.