6 resultados para Plants, Sex in
em Instituto Politécnico do Porto, Portugal
Resumo:
The interest for environmental fate assessment of chiral pharmaceuticals is increasing and enantioselective analytical methods are mandatory. This study presents an enantioselective analytical method for the quantification of seven pairs of enantiomers of pharmaceuticals and a pair of a metabolite. The selected chiral pharmaceuticals belong to three different therapeutic classes, namely selective serotonin reuptake inhibitors (venlafaxine, fluoxetine and its metabolite norfluoxetine), beta-blockers (alprenolol, bisoprolol, metoprolol, propranolol) and a beta2-adrenergic agonist (salbutamol). The analytical method was based on solid phase extraction followed by liquid chromatography tandem mass spectrometry with a triple quadrupole analyser. Briefly, Oasis® MCX cartridges were used to preconcentrate 250 mL of water samples and the reconstituted extracts were analysed with a Chirobiotic™ V under reversed mode. The effluent of a laboratory-scale aerobic granular sludge sequencing batch reactor (AGS-SBR) was used to validate the method. Linearity (r2 > 0.99), selectivity and sensitivity were achieved in the range of 20–400 ng L−1 for all enantiomers, except for norfluoxetine enantiomers which range covered 30–400 ng L−1. The method detection limits were between 0.65 and 11.5 ng L−1 and the method quantification limits were between 1.98 and 19.7 ng L−1. The identity of all enantiomers was confirmed using two MS/MS transitions and its ion ratios, according to European Commission Decision 2002/657/EC. This method was successfully applied to evaluate effluents of wastewater treatment plants (WWTP) in Portugal. Venlafaxine and fluoxetine were quantified as non-racemic mixtures (enantiomeric fraction ≠ 0.5). The enantioselective validated method was able to monitor chiral pharmaceuticals in WWTP effluents and has potential to assess the enantioselective biodegradation in bioreactors. Further application in environmental matrices as surface and estuarine waters can be exploited.
Resumo:
Gamma radiations measurements were carried out in the vicinity of a coal-fired power plant located in the southwest coastline of Portugal. Two different gamma detectors were used to assess the environmental radiation within a circular area of 20 km centred in the coal plant: a scintillometer (SPP2 NF, Saphymo) and a high purity germanium detector (HPGe, Canberra). Fifty urban and suburban measurements locations were established within the defined area and two measurements campaigns were carried out. The results of the total gamma radiation ranged from 20.83 to 98.33 counts per second (c.p.s.) for both measurement campaigns and outdoor doses rates ranged from 77.65 to 366.51 Gy/h. Natural emitting nuclides from the U-238 and Th-232 decay series were identified as well as the natural emitting nuclide K-40. The radionuclide concentration from the uranium and thorium series determined by gamma spectrometry ranged from 0.93 to 73.68 Bq/kg, while for K-40 the concentration ranged from 84.14 to 904.38 Bq/kg. The obtained results were used primarily to define the variability in measured environmental radiation and to determine the coal plant’s influence in the measured radiation levels. The highest values were measured at two locations near the power plant and at locations between the distance of 6 and 20 km away from the stacks, mainly in the prevailing wind direction. The results showed an increase or at least an influence from the coal-fired plant operations, both qualitatively and quantitatively.
Resumo:
Introduction: Healthcare improvements have allowed prevention but have also increased life expectancy, resulting in more people being at risk. Our aim was to analyse the separate effects of age, period and cohort on incidence rates by sex in Portugal, 2000–2008. Methods: From the National Hospital Discharge Register, we selected admissions (aged ≥49 years) with hip fractures (ICD9-CM, codes 820.x) caused by low/moderate trauma (falls from standing height or less), readmissions and bone cancer cases. We calculated person-years at risk using population data from Statistics Portugal. To identify period and cohort effects for all ages, we used an age–period–cohort model (1-year intervals) followed by generalised additive models with a negative binomial distribution of the observed incidence rates of hip fractures. Results: There were 77,083 hospital admissions (77.4 % women). Incidence rates increased exponentially with age for both sexes (age effect). Incidence rates fell after 2004 for women and were random for men (period effect). There was a general cohort effect similar in both sexes; risk of hip fracture altered from an increasing trend for those born before 1930 to a decreasing trend following that year. Risk alterations (not statistically significant) coincident with major political and economic change in the history of Portugal were observed around birth cohorts 1920 (stable–increasing), 1940 (decreasing–increasing) and 1950 (increasing–decreasing only among women). Conclusions: Hip fracture risk was higher for those born during major economically/politically unstable periods. Although bone quality reflects lifetime exposure, conditions at birth may determine future risk for hip fractures.
Resumo:
The reactive power management in distribution network with large penetration of distributed energy resources is an important task in future power systems. The control of reactive power allows the inclusion of more distributed recourses and a more efficient operation of distributed network. Currently, the reactive power is only controlled in large power plants and in high and very high voltage substations. In this paper, several reactive power control strategies considering a smart grids paradigm are proposed. In this context, the management of distributed energy resources and of the distribution network by an aggregator, namely Virtual Power Player (VPP), is proposed and implemented in a MAS simulation tool. The proposed methods have been computationally implemented and tested using a 32-bus distribution network with intensive use of distributed resources, mainly the distributed generation based on renewable resources. Results concerning the evaluation of the reactive power management algorithms are also presented and compared.
Resumo:
Proceedings of the 13th International UFZ-Deltares Conference on Sustainable Use and Management of Soil, Sediment and Water Resources - 9–12 June 2015 • Copenhagen, Denmark
Resumo:
Esta dissertação descreve o trabalho desenvolvido ao longo de um ano e um mês desde a pesquisa teórica até à prática experimental no âmbito da unidade curricular de Dissertação/estágio do Mestrado em Engenharia Química, no ramo Tecnologias em Proteção Ambiental. O tema desta dissertação consiste na avaliação do funcionamento de duas estações de tratamento de águas residuais (ETAR) do interior do município de Vila Nova de Gaia no que diz respeito ao possível aumento da resistência a antibióticos na ETAR de Febros e na ETAR de Lever. Os testes de sensibilidade a antibióticos (TSA) foram executados para ambas as ETAR, sendo as amostras de água recolhidas na entrada e na saída dos reatores biológicos (tratamento secundário). Além disso, foram realizados testes de avaliação da eficiência de desinfeção por radiação ultravioleta (UV) relativamente à Escherichia coli (E. coli) na ETAR de Lever. Os antibióticos selecionados para a realização deste trabalho foram a Eritromicina, a Azitromicina, a Claritromicina, a Ofloxacina, a Ciprofloxacina, o Sulfametoxazol, o Trimetoprim e o Metronidazol. Esta seleção baseou-se no facto de estes serem alguns dos antibióticos mais consumidos e mais persistentes no meio ambiente. A bactéria E. coli (isolada a partir de amostras das águas residuais estudadas) foi escolhida para a realização deste estudo uma vez que está sempre presente nas águas residuais domésticas e está associada a fenómenos de multirresistência a antibióticos. Os testes de TSA foram realizados seguindo a metodologia de difusão por discos. No período do estudo (Março a Junho de 2015) identificaram-se situações quer de aumento de resistência quer de aumento de sensibilidade aos antibióticos testados. As situações mais graves de aumento de resistência, a que corresponderam a halos nulos, verificaram-se para os antibióticos Claritromicina, Trimetoprim e Metronidazol, ocorrendo com maior frequência para os dois últimos, que aliás são fármacos que são administrados em simultâneo. Os períodos mais problemáticos em termos de aumento das resistências foram ligeiramente diferentes nas duas ETAR. No caso da ETAR de Febros correspondeu ao mês Abril e na ETAR de Lever ocorreu entre o final de Abril e o início de Maio. Considera-se que estes períodos poderão coincidir com um aumento do consumo destes fármacos devido à sua utilização no combate a infeções respiratórias muito comuns nesta altura do ano. Não se observou qualquer sensibilidade da E. coli para o Metronidazol porque é um antibiótico com indicação para algumas bactérias anaeróbias, fungos e giardia, e que à partida não tem capacidade para eliminar a E. coli. A eficiência da desinfeção na ETAR de Lever relativamente à remoção de E. coli foi satisfatória. Sendo de salientar a importância da manutenção, no que se refere à identificação de possíveis avarias nas lâmpadas e correspondente limpeza. Os resultados deste trabalho provam a existência de estirpes da bactéria E. coli resistentes a alguns dos antibióticos estudados, o que reforça a importância da desinfeção no tratamento de águas residuais domésticas.