10 resultados para Packed-beds
em Instituto Politécnico do Porto, Portugal
Resumo:
A mathematical model is proposed for the evolution of temperature, chemical composition, and energy release in bubbles, clouds, and emulsion phase during combustion of gaseous premixtures of air and propane in a bubbling fluidized bed. The analysis begins as the bubbles are formed at the orifices of the distributor, until they explode inside the bed or emerge at the free surface of the bed. The model also considers the freeboard region of the fluidized bed until the propane is thoroughly burned. It is essentially built upon the quasi-global mechanism of Hautman et al. (1981) and the mass and heat transfer equations from the two-phase model of Davidson and Harrison (1963). The focus is not on a new modeling approach, but on combining the classical models of the kinetics and other diffusional aspects to obtain a better insight into the events occurring inside a fluidized bed reactor. Experimental data are obtained to validate the model by testing the combustion of commercial propane, in a laboratory-scale fluidized bed, using four sand particle sizes: 400–500, 315–400, 250–315, and 200–250 µm. The mole fractions of CO2, CO, and O2 in the flue gases and the temperature of the fluidized bed are measured and compared with the numerical results.
Resumo:
STRIPPING is a software application developed for the automatic design of a randomly packing column where the transfer of volatile organic compounds (VOCs) from water to air can be performed and to simulate it’s behaviour in a steady-state. This software completely purges any need of experimental work for the selection of diameter of the column, and allows a choice, a priori, of the most convenient hydraulic regime for this type of operation. It also allows the operator to choose the model used for the calculation of some parameters, namely between the Eckert/Robbins model and the Billet model for estimating the pressure drop of the gaseous phase, and between the Billet and Onda/Djebbar’s models for the mass transfer. Illustrations of the graphical interface offered are presented.
Resumo:
O objectivo desta tese é dimensionar um secador em leito fluidizado para secagem de cereais, nomeadamente, secagem de sementes de trigo. Inicialmente determinaram-se as condições de hidrodinâmica (velocidade de fluidização, TDH, condições mínimas de “slugging”, expansão do leito, dimensionamento do distribuidor e queda de pressão). Com as condições de hidrodinâmica definidas, foi possível estimar as dimensões físicas do secador. Neste ponto, foram realizados estudos relativamente à cinética da secagem e à própria secagem. Foi também estudado o transporte pneumático das sementes. Deste modo, determinaram-se as velocidades necessárias ao transporte pneumático e respectivas quedas de pressão. Por fim, foi realizada uma análise custos para que se soubesse o custo deste sistema de secagem. O estudo da secagem foi feito para uma temperatura de operação de 50ºC, tendo a ressalva que no limite se poderia trabalhar com 60ºC. A velocidade de operação é de 2,43 m/s, a altura do leito fixo é de 0,4 m, a qual sofre uma expansão durante a fluidização, assumindo o valor de 0,79 m. O valor do TDH obtido foi de 1,97 m, que somado à expansão do leito permite obter uma altura total da coluna de 2,76 m. A altura do leito fixo permite retirar o valor do diâmetro que é de 0,52 m. Verifica-se que a altura do leito expandido é inferior à altura mínima de “slugging” (1,20 m), no entanto, a velocidade de operação é superior à velocidade mínima de “slugging” (1,13 m/s). Como só uma das condições mínimas é cumprida, existe a possibilidade da ocorrência de “slugging”. Finalmente, foi necessário dimensionar o distribuidor, que com o diâmetro de orifício de 3 mm, valor inferior ao da partícula (3,48 mm), permite a distruibuição do fluido de secagem na coluna através dos seus 3061 orifícios. O inicio do estudo da secagem centrou-se na determinação do tempo de secagem. Além das duas temperaturas atrás referidas, foram igualmente consideradas duas humidades iniciais para os cereais (21,33% e 18,91%). Temperaturas superiores traduzem-se em tempos de secagem inferiores, paralelamente, teores de humidade inicial inferiores indicam tempos menores. Para a temperatura de 50ºC, os tempos de secagem assumiram os valores de 2,8 horas para a 21,33% de humidade e 2,7 horas para 18,91% de humidade. Foram também tidas em conta três alturas do ano para a captação do ar de secagem, Verão e Inverno representando os extremos, e a Meia- Estação. Para estes três casos, foi possível verificar que a humidade específica do ar não apresenta alterações significativas entre a entrada no secador e a corrente de saída do mesmo equipamento, do mesmo modo que a temperatura de saída pouco difere da de entrada. Este desvio de cerca de 1% para as humidades e para as temperaturas é explicado pela ausência de humidade externa nas sementes e na pouca quantidade de humidade interna. Desta forma, estes desvios de 1% permitem a utilização de uma razão de reciclagem na ordem dos 100% sem que o comportamento da secagem se altere significativamente. O uso de 100% de reciclagem permite uma poupança energética de cerca de 98% no Inverno e na Meia-Estação e de cerca de 93% no Verão. Caso não fosse realizada reciclagem, seria necessário fornecer à corrente de ar cerca de 18,81 kW para elevar a sua temperatura de 20ºC para 50ºC (Meia-Estação), cerca de 24,67 kW para elevar a sua temperatura de 10ºC para 50ºC (Inverno) e na ordem dos 8,90 kW para elevar a sua temperatura dos 35ºC para 50ºC (Verão). No caso do transporte pneumático, existem duas linhas, uma horizontal e uma vertical, logo foi necessário estimar o valor da velocidade das partículas para estes dois casos. Na linha vertical, a velocidade da partícula é cerca de 25,03 m/s e cerca de 35,95 m/s na linha horizontal. O menor valor para a linha vertical prende-se com o facto de nesta zona ter que se vencer a força gravítica. Em ambos os circuitos a velocidade do fluido é cerca de 47,17 m/s. No interior da coluna, a velocidade do fluido tem o valor de 10,90 m/s e a velocidade das partículas é de 1,04 m/s. A queda de pressão total no sistema é cerca de 2408 Pa. A análise de custos ao sistema de secagem indicou que este sistema irá acarretar um custo total (fabrico mais transporte) de cerca de 153035€. Este sistema necessita de electricidade para funcionar, e esta irá acarretar um custo anual de cerca de 7951,4€. Embora este sistema de secagem apresente a possibilidade de se realizar uma razão de reciclagem na ordem dos 100% e também seja possível adaptar o mesmo para diferentes tipos de cereais, e até outros tipos de materiais, desde que possam ser fluidizados, o seu custo impede que a realização deste investimento não seja atractiva, especialmente tendo em consideração que se trata de uma instalação à escala piloto com uma capacidade de 45 kgs.
Resumo:
The occurrence of OTA in fresh and packed wheat and in maize bread and the evaluation of the exposure degree through their consumption in two Portuguese populations from Porto and Coimbra, during the winter of 2007, were studied. One hundred and sixty eight bread samples, 61 maize and 107 wheat, were analysed by liquid chromatography–fluorescence detection (LC–FD). The results showed that 84% of samples were contaminated, with a maximum level of 3.85 ng/g (above the EU maximum limit, 3 ng/g). Fresh wheat bread presented higher levels than packed wheat bread. Moreover, the traditional maize bread, in either city, was consistently more contaminated than wheat bread, 0.25 vs 0.19 ng/g, and 0.48 vs 0.34 ng/ g for Porto and Coimbra, respectively. Avintes maize bread showed the highest mean contamination and maximum levels. The higher estimated daily intake of OTA from both types of bread in the population of Coimbra compared to Porto reflects the higher average contamination of bread in the first city.
Resumo:
The impact of effluent wastewaters from four different hospitals: a university (1456 beds), a general (350 beds), a pediatric (110 beds) and a maternity hospital (96 beds), which are conveyed to the same wastewater treatment plant (WWTP), was evaluated in the receiving urban wastewaters. The occurrence of 78 pharmaceuticals belonging to several therapeutic classes was assessed in hospital effluents and WWTP wastewaters (influent and effluent) as well as the contribution of each hospital in WWTP influent in terms of pharmaceutical load. Results indicate that pharmaceuticals are widespread pollutants in both hospital and urban wastewaters. The contribution of hospitals to the input of pharmaceuticals in urban wastewaters widely varies, according to their dimension. The estimated total mass loadings were 306 g d− 1 for the university hospital, 155 g d− 1 for the general one, 14 g d− 1 for the pediatric hospital and 1.5 g d− 1 for the maternity hospital, showing that the biggest hospitals have a greater contribution to the total mass load of pharmaceuticals. Furthermore, analysis of individual contributions of each therapeutic group showed that NSAIDs, analgesics and antibiotics are among the groups with the highest inputs. Removal efficiency can go from over 90% for pharmaceuticals like acetaminophen and ibuprofen to not removal for β-blockers and salbutamol. Total mass load of pharmaceuticals into receiving surface waters was estimated between 5 and 14 g/d/1000 inhabitants. Finally, the environmental risk posed by pharmaceuticals detected in hospital and WWTP effluents was assessed by means of hazard quotients toward different trophic levels (algae, daphnids and fish). Several pharmaceuticals present in the different matrices were identified as potentially hazardous to aquatic organisms, showing that especial attention should be paid to antibiotics such as ciprofloxacin, ofloxacin, sulfamethoxazole, azithromycin and clarithromycin, since their hazard quotients in WWTP effluent revealed that they could pose an ecotoxicological risk to algae.
Resumo:
Bisphenol A (BPA) is an endocrine disrupting chemical (EDC) whose migration from food packaging is recognized worldwide. However, the real overall food contamination and related consequences are yet largely unknown. Among humans, children’s exposure to BPA has been emphasized because of the immaturity of their biological systems. The main aim of this study was to assess the reproductive impact of BPA leached from commercially available plastic containers used or related to child nutrition, performing ecotoxicological tests using the biomonitoring species Daphnia magna. Acute and chronic tests, as well as single and multigenerational tests were done. Migration of BPA from several baby bottles and other plastic containers evaluated by GC-MS indicated that a broader range of foodstuff may be contaminated when packed in plastics. Ecotoxicological test results performed using defined concentrations of BPA were in agreement with literature, although a precocious maturity of daphnids was detected at 3.0 mg/L. Curiously, an increased reproductive output (neonates per female) was observed when daphnids were bred in the polycarbonate (PC) containers (145.1±4.3 % to 264.7±3.8 %), both in single as in multigenerational tests, in comparison with the negative control group (100.3±1.6 %). A strong correlated dose-dependent ecotoxicological effect was observed, providing evidence that BPA leached from plastic food packaging materials act as functional estrogen in vivo at very low concentrations. In contrast, neonate production by daphnids cultured in polypropylene and non-PC bottles was slightly but not significantly enhanced (92.5±2.0 % to 118.8±1.8 %). Multigenerational tests also revealed magnification of the adverse effects, not only on fecundity but also on mortality, which represents a worrying trend for organisms that are chronically exposed to xenoestrogens for many generations. Two plausible explanations for the observed results could be given: a non-monotonic dose–response relationship or a mixture toxicity effect.
Resumo:
The IEEE 802.15.4/Zigbee protocols are a promising technology for Wireless Sensor Networks (WSNs). This paper shares our experience on the implementation and use of these protocols and related technologies in WSNs. We present problems and challenges we have been facing in implementing an IEEE 802.15.4/ZigBee stack for TinyOS in a two-folded perspective: IEEE 802.15.4/ZigBee protocol standards limitations (ambiguities and open issues) and technological limitations (hardware and software). Concerning the former, we address challenges for building scalable and synchronized multi-cluster ZigBee networks, providing a trade-off between timeliness and energy-efficiency. On the latter issue, we highlight implementation problems in terms of hardware, timer handling and operating system limitations. We also report on our experience from experimental test-beds, namely on physical layer aspects such as coexistence problems between IEEE 802.15.4 and 802.11 radio channels.
Resumo:
O presente trabalho centra-se na gestão de resíduos produzidos no sistema de drenagem e tratamento de águas residuais do município de Vila Nova de Gaia. A entidade onde decorreu o trabalho é uma empresa responsável pela distribuição de água e pela drenagem e tratamento de águas residuais. A empresa está certificada pela norma NP EN ISO 14001, desde 2001, sendo então um dos objectivos o enquadramento da gestão dos resíduos em estudo na referida norma, acompanhando os requisitos da mesma com vista ao seu total cumprimento. Outros dos objectivos foi estudar qual a opção de tratamento mais adequada a aplicar ao resíduo no seu local de armazenamento temporário com vista a minorar os seus impactes ambientais. De acordo com a caracterização analítica do resíduo e com os aspetos legais aplicáveis, foram também analisados os destinos finais possíveis e ambientalmente adequados ao resíduo. A medida proposta para a minimização de impactes no local de armazenamento temporário do resíduo foi a estabilização com cal nos leitos de secagem, disponíveis numa antiga ETAR de loteamento. O doseamento de cal a aplicar ao resíduo será de 10 kg de cal apagada comercial (Ca (OH)2) por uma tonelada de resíduo fresco com um período mínimo de secagem de 2 meses. Outra das medidas de minimização de impactes selecionada foi a implantação de uma cortina arbórea ao redor da instalação. Sendo o resíduo em estudo muito heterogéneo, constituído principalmente por areias, terras e gradados, a valorização foi equacionada mas não foram encontrados alternativas viáveis. O destino final considerado como mais adequado tendo em conta todas as características do resíduo e eluato, analisadas de acordo com o previsto no Decreto-Lei n.º 183/2009 de 10 de Agosto, foi o aterro para resíduos não perigosos. Foi também objecto do estudo a identificação e análise de todos os aspectos ambientais relacionados com a gestão de resíduos e a avaliação da sua significância. Dos aspectos ambientais identificados como significativos, destacam-se aqueles que ocorrem presentemente, os resíduos armazenados (gradados/limpeza de redes), e os que podem ocorrer em situações de emergência, fuga/derrame de óleos/combustíveis e cheiros/odores. De forma a minimizar os aspectos ambientais identificados, e de acordo com a norma NP EN ISO 14001, foram propostas ações que constam de um programa de gestão elaborado para este trabalho, onde se definem os objectivos, metas e prazos. As principais medidas propostas no programa de gestão foram: Estabilização com cal (inicial e reforço se necessário); melhoria do espaço envolvente; análise de questões de saúde ocupacional/segurança; adjudicação de prestação de serviços da recolha por operador licenciado; implantação da cortina arbórea; registo no SIRAPA; criação de planos de emergência ambiental e de segurança.
Resumo:
Radio link quality estimation is essential for protocols and mechanisms such as routing, mobility management and localization, particularly for low-power wireless networks such as wireless sensor networks. Commodity Link Quality Estimators (LQEs), e.g. PRR, RNP, ETX, four-bit and RSSI, can only provide a partial characterization of links as they ignore several link properties such as channel quality and stability. In this paper, we propose F-LQE (Fuzzy Link Quality Estimator, a holistic metric that estimates link quality on the basis of four link quality properties—packet delivery, asymmetry, stability, and channel quality—that are expressed and combined using Fuzzy Logic. We demonstrate through an extensive experimental analysis that F-LQE is more reliable than existing estimators (e.g., PRR, WMEWMA, ETX, RNP, and four-bit) as it provides a finer grain link classification. It is also more stable as it has lower coefficient of variation of link estimates. Importantly, we evaluate the impact of F-LQE on the performance of tree routing, specifically the CTP (Collection Tree Protocol). For this purpose, we adapted F-LQE to build a new routing metric for CTP, which we dubbed as F-LQE/RM. Extensive experimental results obtained with state-of-the-art widely used test-beds show that F-LQE/RM improves significantly CTP routing performance over four-bit (the default LQE of CTP) and ETX (another popular LQE). F-LQE/RM improves the end-to-end packet delivery by up to 16%, reduces the number of packet retransmissions by up to 32%, reduces the Hop count by up to 4%, and improves the topology stability by up to 47%.
Resumo:
A água é um recurso natural único, escasso e essencial a todos os seres vivos, o que a torna um bem de extrema importância. Nos dias de hoje, o desperdício deste bem, aliado ao aumento da sua procura, tornou-se um problema devido à decrescente disponibilidade de água doce no nosso planeta. Todas as águas que rejeitamos depois da sua utilização para diversos fins, designadas de águas residuais, necessitam de tratamento antes de serem devolvidas ao meio ambiente. O seu tratamento é realizado numa Estação de Tratamento de Águas Residuais (ETAR) e o processo de tratamento depende das suas características. A ETAR das Termas de S. Vicente, em Penafiel, trabalha no seu limite de capacidade, apresenta uma sobrecarga hidráulica gerada por uma afluência de águas pluviais e o processamento das lamas geradas não permite uma secagem tão completa como seria desejável. Assim, este trabalho teve como objetivo o estudo do funcionamento desta ETAR com a finalidade de propor soluções que o possam otimizar. As soluções propostas para otimizar o funcionamento da ETAR em estudo são: i) a substituição de grades de limpeza manual por grades de limpeza automática de forma a reduzir a necessidade da intervenção do operador ao nível da remoção e condicionamento dos gradados; ii) a construção de um desarenador arejado que além de remover areias de diâmetro superior a 0,2 mm promove também a remoção de gorduras, protegendo desta forma os equipamentos a jusante da abrasão/desgaste prematuros e reduzindo a formação de depósitos nas tubagens; iii) a construção de um tanque de equalização de forma a garantir uma distribuição mais uniforme dos caudais e da carga poluente; iv) a substituição do enchimento do leito percolador por um meio de suporte plástico que permite atingir melhores eficiências de remoção neste tratamento biológico; v) a alteração do agente de desinfeção para radiação ultravioleta, evitando a adição de produtos químicos na água residual e possível formação de subprodutos prejudiciais ao ambiente, como ocorreria no caso da cloragem; e vi) a substituição da desidratação de lamas em leitos de secagem por filtros de banda, que é um processo mais rápido, que ocupa menos espaço e permite atingir elevadas eficiências de remoção de humidade. Para cada uma das sugestões são apresentadas as correspondentes especificações técnicas e dimensionamento. As sugestões de melhoria apresentadas neste trabalho constituem uma alternativa mais económica do que a ampliação da ETAR, que genericamente corresponde à duplicação da linha de tratamento atual. Devido à menor complexidade em termos de construção, estas sugestões podem vir a ser implementadas num futuro próximo, prolongando assim um pouco mais a vida útil da ETAR atual.