9 resultados para Oxygen Equilibrium Curve
em Instituto Politécnico do Porto, Portugal
Resumo:
Mestrado em Engenharia Química
Resumo:
This research work has been focused in the study of gallinaceous feathers, a waste that may be valorised as sorbent, to remove the Dark Blue Astrazon 2RN (DBA) from Dystar. This study was focused on the following aspects: optimization of experimental conditions through factorial design methodology, kinetic studies into a continuous stirred tank adsorber (at pH 7 and 20ºC), equilibrium isotherms (at pH 5, 7 and 9 at 20 and 45ºC) and column studies (at 20ºC, at pH 5, 7 and 9). In order to evaluate the influence of the presence of other components in the sorption of the dyestuff, all experiments were performed both for the dyestuff in aqueous solution and in real textile effluent. The pseudo-first and pseudo-second order kinetic models were fitted to the experimental data, being the latter the best fit for the aqueous solution of dyestuff. For the real effluent both models fit the experimental results and there is no statistical difference between them. The Central Composite Design (CCD) was used to evaluate the effects of temperature (15 - 45ºC) and pH (5 - 9) over the sorption in aqueous solution. The influence of pH was more significant than temperature. The optimal conditions selected were 45ºC and pH 9. Both Langmuir and Freundlich models could fit the equilibrium data. In the concentration range studied, the highest sorbent capacity was obtained for the optimal conditions in aqueous solution, which corresponds to a maximum capacity of 47± 4 mg g-1. The Yoon-Nelson, Thomas and Yan’s models fitted well the column experimental data. The highest breakthrough time for 50% removal, 170 min, was obtained at pH 9 in aqueous solution. The presence of the dyeing agents in the real wastewater decreased the sorption of the dyestuff mostly for pH 9, which is the optimal pH. The effect of pH is less pronounced in the real effluent than in aqueous solution. This work shows that feathers can be used as sorbent in the treatment of textile wastewaters containing DBA.
Resumo:
O presente trabalho experimental teve como objectivos estudar a tratabilidade dum efluente lácteo utilizando a técnica de coagulação/floculação e avaliar a possibilidade de utilização do carvão activado granulado (CAG) Aquasorb 2000 como adsorvente para a remoção de compostos orgânicos presentes nos efluentes lácteos pré–tratados por coagulação/floculação, funcionando como um tratamento de polimento. No estudo da tratabilidade do efluente por coagulação/floculação investigou-se a influência de determinadas variáveis como o tipo e dose de coagulante e pH, a fim de encontrar as melhores condições operatórias. A utilização da referida técnica visou a redução do valor de concentração de alguns parâmetros: carência química de oxigénio (CQO); fósforo total e turvação, tendo sido utilizados efluentes desta indústria recolhidos em diferentes datas e após tratamento biológico, designados por A, B, C e D apresentando características diferentes. Sendo que o efluente A apresentava valores de CQO, fósforo total e turvação de 500 mg O2/L;32 mg P/L e 40 NTU respectivamente, o efluente B 1400 mg O2/L; 120 mg P/L e 80 NTU respectivamente, o efluente C 12300 mg O2/L; 87 mg P/L e 350 NTU respectivamente e o efluente D 340 mg O2/L; 33 mg P/L e 42 NTU respectivamente. Os coagulantes estudados foram hidróxido de cálcio (HC), sulfato de alumínio (SA) e tricloreto de ferro (TF). Verificou-se que o coagulante com maior eficácia nos efluentes estudados foi o TF. As maiores remoções de CQO, fósforo total e turvação, 89%, 99,9% e 99%, respectivamente, foram obtidas para o efluente C, com uma dosagem de TF de 4 g/L e com um pH entre 6 e 7. Entre os efluentes estudados este era o que apresentava valores iniciais mais elevados para qualquer um destes parâmetros. As melhores percentagens de remoção obtidas com o HC, para a CQO, fósforo total e turvação foram de 59%, 99% e 91%, respectivamente, com uma dosagem de HC de 1 g/L e com um pH entre 10 e 11,5 foram conseguidas no tratamento do efluente D, com o qual se alcançaram também as melhores remoções de CQO, fósforo total e turvação de 65%, 99% e 87%, respectivamente, quando se utilizou o coagulante SA, com uma dosagem de 2 g/L e com um pH entre 7 e 7,5. Relativamente ao volume de lamas produzido neste processo pela utilização dos diferentes coagulantes no tratamento dos efluentes referidos concluiu-se que o coagulante que gera menor volume de lamas é o HC, sendo o SA aquele que origina um maior volume. Submeteu-se posteriormente o efluente D, pré-tratado por coagulação/floculação, a um processo de adsorção em batch utilizando o CAG Aquasorb 2000, onde se conseguiu uma remoção de CQO de 48%, alcançando para este parâmetro o valor de 63 mg O2/L, nas condições operatórias que correspondem a uma massa de CAG de 12,5 g/L e um tempo de contacto de 3 horas. Quanto aos custos associados com os coagulantes, o que menores custos apresenta é o HC (150 €/ton), seguido pelo TF (250 €/ton) e por ultimo o SA (340 €/ton). Sendo que o efluente quando tratado com TF e SA é necessário uma correcção do pH do meio para que estes coagulantes actuem eficazmente, em que essa correcção de pH é realizada com hidróxido de sódio (540 €/ton). Realizaram-se ainda estudos de equilíbrio de adsorção com o carvão activado referido e o azul-de-metileno usando diferentes concentrações deste (50 mg/L; 100 mg/L e 200 mg/L) e diferentes massas de CAG (0,1g; 0,2g; 0,3g; 0,4g e 0,5g). A temperatura a que se realizaram estes ensaios foi de 28,7ºC e o volume de azul-de-metileno foi de 200 mL. Verificou-se que os melhores resultados obtidos foram para uma concentração de adsorvato de 100 mg/L. Ajustaram-se os modelos de Langmuir e Freundlich às isotérmicas obtidas tendo correlações mais elevadas para a concentração de 100 mg/L de corante (azul de metileno), sendo o modelo de Freundlich aquele que melhor se ajustou apresentando uma correlação quadrática de 0,9744 e os seguintes parâmetros Kf = 6,59 e n = 5,33, enquanto que o de Langmuir apresentou uma correlação quadrática de 0,9583 e os seguintes parâmetros qmáx = 83,3 mg/g de adsorvente e K = 20 L/mg de adsorvato.. Verificou-se que a capacidade de adsorção promovida pelo CAG, em relação ao azul-demetileno, obtida experimentalmente, 83,3 mg/g, é muito inferior à capacidade de adsorção teoricamente prevista pela ficha técnica deste carvão, 280 mg/g a uma temperatura de 25ºC, o que pode indiciar que o carvão utilizado não estaria nas melhores condições.
Resumo:
This research work aims to study the use of peanut hulls, an agricultural and food industry waste, for copper and lead removal through equilibrium and kinetic parameters evaluation. Equilibrium batch studies were performed in a batch adsorber. The influence of initial pH was evaluated (3–5) and it was selected between 4.0 and 4.5. The maximum sorption capacities obtained for the Langmuir model were 0.21 ± 0.03 and 0.18 ± 0.02 mmol/g, respectively for copper and lead. In bi-component systems, competitive sorption of copper and lead was verified, the total amount adsorbed being around 0.21 mmol of metal per gram of material in both mono and bi-component systems. In the kinetic studies equilibrium was reached after 200 min contact time using a 400 rpm stirring rate, achieving 78% and 58% removal, in mono-component system, for copper and lead respectively. Their removal follows a pseudo-second-order kinetics. These studies show that most of the metals removal occurred in the first 20 min of contact, which shows a good uptake rate in all systems.
Resumo:
Smart grids with an intensive penetration of distributed energy resources will play an important role in future power system scenarios. The intermittent nature of renewable energy sources brings new challenges, requiring an efficient management of those sources. Additional storage resources can be beneficially used to address this problem; the massive use of electric vehicles, particularly of vehicle-to-grid (usually referred as gridable vehicles or V2G), becomes a very relevant issue. This paper addresses the impact of Electric Vehicles (EVs) in system operation costs and in power demand curve for a distribution network with large penetration of Distributed Generation (DG) units. An efficient management methodology for EVs charging and discharging is proposed, considering a multi-objective optimization problem. The main goals of the proposed methodology are: to minimize the system operation costs and to minimize the difference between the minimum and maximum system demand (leveling the power demand curve). The proposed methodology perform the day-ahead scheduling of distributed energy resources in a distribution network with high penetration of DG and a large number of electric vehicles. It is used a 32-bus distribution network in the case study section considering different scenarios of EVs penetration to analyze their impact in the network and in the other energy resources management.
Resumo:
The container loading problem (CLP) is a combinatorial optimization problem for the spatial arrangement of cargo inside containers so as to maximize the usage of space. The algorithms for this problem are of limited practical applicability if real-world constraints are not considered, one of the most important of which is deemed to be stability. This paper addresses static stability, as opposed to dynamic stability, looking at the stability of the cargo during container loading. This paper proposes two algorithms. The first is a static stability algorithm based on static mechanical equilibrium conditions that can be used as a stability evaluation function embedded in CLP algorithms (e.g. constructive heuristics, metaheuristics). The second proposed algorithm is a physical packing sequence algorithm that, given a container loading arrangement, generates the actual sequence by which each box is placed inside the container, considering static stability and loading operation efficiency constraints.
Resumo:
Optically transparent cocatalyst film materials is very desirable for improved photoelectrochemical (PEC)oxygen evolution reaction (OER) over light harvesting photoelectrodes which require the exciting light to irradiate through the cocatalyst side, i.e., front-side illumination. In view of the reaction overpotential at electrode/electrolyte interface, the OER electrocatalysts have been extensively used as cocatalysts for PEC water oxidation on photoanode. In this work, the feasibility of a one-step fabrication of the transparent thin film catalyst for efficient electrochemical OER is investigated. The Ni-Fe bimetal oxide films, 200 nm in thickness, are used for study. Using a reactive magnetron co-sputtering technique, transparent(> 50% in wavelength range 500-2000 nm) Ni-Fe oxide films with high electrocatalytic activities were successfully prepared at room temperature. Upon optimization, the as-prepared bimetal oxide film with atomic ratio of Fe/Ni = 3:7 demonstrates the lowest overpotential for the OER in aqueous KOH solution, as low as 329 mV at current density of 2 mA cm 2, which is 135 and 108 mV lower than that of as-sputtered FeOx and NiOx thin films, respectively. It appears that this fabrication strategy is very promising to deposit optically transparent cocatalyst films on photoabsorbers for efficient PEC water splitting.
Resumo:
Selenium modified ruthenium electrocatalysts supported on carbon black were synthesized using NaBH4 reduction of the metal precursor. Prepared Ru/C electrocatalysts showed high dispersion and very small averaged particle size. These Ru/C electrocatalysts were subsequently modified with Se following two procedures: (a) preformed Ru/carbon catalyst was mixed with SeO2 in xylene and reduced in H2 and (b) Ru metal precursor was mixed with SeO2 followed by reduction with NaBH4. The XRD patterns indicate that a pyrite-type structure was obtained at higher annealing temperatures, regardless of the Ru:Se molar ratio used in the preparation step. A pyrite-type structure also emerged in samples that were not calcined; however, in this case, the pyrite-type structure was only prominent for samples with higher Ru:Se ratios. The characterization of the RuSe/C electrocatalysts suggested that the Se in noncalcined samples was present mainly as an amorphous skin. Preliminary study of activity toward oxygen reduction reaction (ORR) using electrocatalysts with a Ru:Se ratio of 1:0.7 indicated that annealing after modification with Se had a detrimental effect on their activity. This result could be related to the increased particle size of crystalline RuSe2 in heat-treated samples. Higher activity of not annealed RuSe/C catalysts could also be a result of the structure containing amorphous Se skin on the Ru crystal. The electrode obtained using not calcined RuSe showed a very promising performance with a slightly lower activity and higher overpotential in comparison with a commercial Pt/C electrode. Single wall carbon nanohorns (SWNH) were considered for application as ORR electrocatalysts' supports. The characterization of SWNH was carried out regarding their tolerance toward strong catalyzed corrosion conditions. Tests indicated that SWNH have a three times higher electrochemical surface area (ESA) loss than carbon black or Pt commercial electrodes.
Resumo:
We consider two Cournot firms, one located in the home country and the other in the foreign country, producing substitute goods for consumption in a third country. We suppose that neither the home government nor the foreign firm know the costs of the home firm, while the foreign firm cost is common knowledge. We determine the separating sequential equilibrium outputs.