9 resultados para Method of moment
em Instituto Politécnico do Porto, Portugal
Resumo:
Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.
Resumo:
This paper presents a methodology for distribution networks reconfiguration in outage presence in order to choose the reconfiguration that presents the lower power losses. The methodology is based on statistical failure and repair data of the distribution power system components and uses fuzzy-probabilistic modelling for system component outage parameters. Fuzzy membership functions of system component outage parameters are obtained by statistical records. A hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzy-probabilistic models allows catching both randomness and fuzziness of component outage parameters. Once obtained the system states by Monte Carlo simulation, a logical programming algorithm is applied to get all possible reconfigurations for every system state. In order to evaluate the line flows and bus voltages and to identify if there is any overloading, and/or voltage violation a distribution power flow has been applied to select the feasible reconfiguration with lower power losses. To illustrate the application of the proposed methodology to a practical case, the paper includes a case study that considers a real distribution network.
Resumo:
It is difficult to get the decision about an opinion after many users get the meeting in same place. It used to spend too much time in order to find solve some problem because of the various opinions of each other. TAmI (Group Decision Making Toolkit) is the System to Group Decision in Ambient Intelligence [1]. This program was composed with IGATA [2], WebMeeting and the related Database system. But, because it is sent without any encryption in IP / Password, it can be opened to attacker. They can use the IP / Password to the bad purpose. As the result, although they make the wrong result, the joined member can’t know them. Therefore, in this paper, we studied the applying method of user’s authentication into TAmI.
Resumo:
O rio Febros é um pequeno curso de água, situado no concelho de Vila Nova de Gaia, com cerca de 15 km de extensão, cuja bacia hidrográfica ocupa uma área de aproximadamente 35,4 km2. Nasce em Seixezelo e desagua na margem esquerda do Rio Douro no Cais do Esteiro, em Avintes. Em Maio de 2008, um acidente de viação teve como consequência o derrame de cerca de quatro toneladas de ácido clorídrico que rapidamente convergiu às águas do rio. Apenas um dia depois, o pH desceu para três e muitos foram os peixes que morreram. A solução adoptada para evitar o desaire foi introduzir milhares de litros de água de modo a diluir o ácido presente, ao longo de todo o curso de água. Tal facto não evitou a destruição de parte de um ecossistema, que ainda nos dias de hoje se encontra em recuperação. De forma a avaliar-se o impacto destas possíveis perturbações sejam estas de origem antropogénica ou natural é necessário possuir conhecimentos dos processos químicos tais como a advecção, a mistura devida à dispersão e a transferência de massa ar/água. Estes processos irão determinar o movimento e destino das substâncias que poderão ser descarregadas no rio. Para tal, recorrer-se-á ao estudo hidrogeométrico do curso de água assim como ao estudo do comportamento de um marcador, simulando uma possível descarga. A rodamina WT será o marcador a ser utilizado devido à panóplia de características ambientalmente favoráveis. Os estudos de campo com este corante, realizados em sequência de descarga previamente estudada, fornecem uma das melhores fontes de informação para verificação e validação de modelos hidráulicos utilizados em estudos de qualidade de águas e protecção ambiental. Escolheram-se dois pontos de descarga no Febros, um em Casal Drijo e outro no Parque Biológico de Gaia, possuindo cada um deles, a jusante, duas estações de monitorização. Pelo modelo ADE os valores obtidos para o coeficiente de dispersão longitudinal para as estações Pontão d’ Alheira, Pinheiral, Menesas e Giestas foram, respectivamente, 0,3622; 0,5468; 1,6832 e 1,7504 m2/s. Para a mesma sequência de estações, os valores da velocidade de escoamento obtidos neste trabalho experimental foram de 0,0633; 0,0684; 0,1548 e 0,1645 m/s. Quanto ao modelo TS, os valores obtidos para o coeficiente de dispersão longitudinal para as estações Pontão d’ Alheira, Pinheiral, Menesas e Giestas foram, respectivamente, 0,2339; 0,1618; 0,5057e 1,1320 m2/s. Para a mesma sequência de estações, os valores da velocidade de escoamento obtidos neste trabalho experimental foram de 0,0652; 0,0775; 0,1891 e 0,1676 m/s. Os resultados foram ajustados por um método directo, o método dos momentos, e por dois métodos indirectos, os modelos ADE e TS. O melhor ajuste corresponde ao modelo TS onde os valores do coeficiente de dispersão longitudinal e da velocidade de escoamento são aqueles que melhor se aproximam da realidade. Quanto ao método dos momentos, o valor estimado para a velocidade é de 0,162 m/s e para o coeficiente de dispersão longitudinal de 9,769 m2/s. Não obstante, a compreensão da hidrodinâmica do rio e das suas características, bem como a adequação de modelos matemáticos no tratamento de resultados formam uma estratégia de protecção ambiental inerente a futuros impactos que possam suceder.
Resumo:
A flow injection analysis (FIA) system comprising a cysteine selective electrode as detection system was developed for determination of this amino acid in pharmaceuticals. Several electrodes were constructed for this purpose, having PVC membranes with different ionic exchangers and mediator solvents. Better working characteristics were attained with membranes comprising o-nitrophenyl octyl ether as mediator solvent and a tetraphenylborate based ionic-sensor. Injection of 500 µL standard solutions into an ionic strength adjuster carrier (3x10-3 M) of barium chloride flowing at 2.4mL min-1, showed linearity ranges from 5.0x10-5 to 5.0x10-3 M, with slopes of 76.4±0.6mV decade-1 and R2>0.9935. Slope decreased significantly under the requirement of a pH adjustment, selected at 4.5. Interference of several compounds (sodium, potassium, magnesium, barium, glucose, fructose, and sucrose) was estimated by potentiometric selectivity coefficients and considered negligible. Analysis of real samples were performed and considered accurate, with a relative error to an independent method of +2.7%.
Resumo:
Ascorbic acid is found in many food samples. Its clinical and technological importance demands an easyto- use, rapid, robust and inexpensive method of analysis. For this purpose, this work proposes a new flow procedure based on the oxidation of ascorbic acid by periodate. A new potentiometric periodate sensor was constructed to monitor this reaction. The selective membranes were of PVC with porphyrin-based sensing systems and a lipophilic cation as additive. The sensor displayed a near-Nernstian response for periodate over 1.0x10-2–6.0x10-6 M, with an anionic slope of 73.9 ± 0.9 mV decade-1. It was pH independent in acidic media and presented good selectivity features towards several inorganic anions. The flow set-up operated in double-channel, carrying a 5.0x10-4 M IO- 4 solution and a suitable buffer; these were mixed in a 50-cm reaction coil. The overall flow rate was 7 ml min-1 and the injection volume 70 µl. Under these conditions, a linear behaviour against concentration was observed for 17.7–194.0 µg ml-1, presenting slopes of 0.169 mV (mg/l)-1, a reproducibility of ±1.1 mV (n = 5), and a sampling rate of ~96 samples h-1. The proposed method was applied to the analysis of beverages and pharmaceuticals.
Resumo:
In the business world, there are issues such as globalisation, environmental awareness, and the rising expectations of public opinion which have a specific role in what is required from companies as providers of information to the market. This chapter refers to the current state of corporate reporting (financial reporting and sustainability reporting) and demonstrates the need for evolution to a more integrated method of reporting which meets the stakeholders’ needs. This research offers a reflection on how this development can be achieved, which notes the ongoing efforts by international organisations in implementing the diffusion and adoption, as well as looking at the characteristics which are needed for this type of reporting. It also makes the link between an actual case of a company that is one of the world references in sustainable development and integrated reporting. Whether or not the integrated reporting is the natural evolution of the history of financial and sustainability reporting, it still cannot yet claim to be infallible. However, it may definitely be concluded that a new approach is necessary to meet the needs which are continuously developing for a network of stakeholders.
Resumo:
The paper formulates a genetic algorithm that evolves two types of objects in a plane. The fitness function promotes a relationship between the objects that is optimal when some kind of interface between them occurs. Furthermore, the algorithm adopts an hexagonal tessellation of the two-dimensional space for promoting an efficient method of the neighbour modelling. The genetic algorithm produces special patterns with resemblances to those revealed in percolation phenomena or in the symbiosis found in lichens. Besides the analysis of the spacial layout, a modelling of the time evolution is performed by adopting a distance measure and the modelling in the Fourier domain in the perspective of fractional calculus. The results reveal a consistent, and easy to interpret, set of model parameters for distinct operating conditions.
Resumo:
As the wireless cellular market reaches competitive levels never seen before, network operators need to focus on maintaining Quality of Service (QoS) a main priority if they wish to attract new subscribers while keeping existing customers satisfied. Speech Quality as perceived by the end user is one major example of a characteristic in constant need of maintenance and improvement. It is in this topic that this Master Thesis project fits in. Making use of an intrusive method of speech quality evaluation, as a means to further study and characterize the performance of speech codecs in second-generation (2G) and third-generation (3G) technologies. Trying to find further correlation between codecs with similar bit rates, along with the exploration of certain transmission parameters which may aid in the assessment of speech quality. Due to some limitations concerning the audio analyzer equipment that was to be employed, a different system for recording the test samples was sought out. Although the new designed system is not standard, after extensive testing and optimization of the system's parameters, final results were found reliable and satisfactory. Tests include a set of high and low bit rate codecs for both 2G and 3G, where values were compared and analysed, leading to the outcome that 3G speech codecs perform better, under the approximately same conditions, when compared with 2G. Reinforcing the idea that 3G is, with no doubt, the best choice if the costumer looks for the best possible listening speech quality. Regarding the transmission parameters chosen for the experiment, the Receiver Quality (RxQual) and Received Energy per Chip to the Power Density Ratio (Ec/N0), these were subject to speech quality correlation tests. Final results of RxQual were compared to those of prior studies from different researchers and, are considered to be of important relevance. Leading to the confirmation of RxQual as a reliable indicator of speech quality. As for Ec/N0, it is not possible to state it as a speech quality indicator however, it shows clear thresholds for which the MOS values decrease significantly. The studied transmission parameters show that they can be used not only for network management purposes but, at the same time, give an expected idea to the communications engineer (or technician) of the end-to-end speech quality consequences. With the conclusion of the work new ideas for future studies come to mind. Considering that the fourth-generation (4G) cellular technologies are now beginning to take an important place in the global market, as the first all-IP network structure, it seems of great relevance that 4G speech quality should be subject of evaluation. Comparing it to 3G, not only in narrowband but also adding wideband scenarios with the most recent standard objective method of speech quality assessment, POLQA. Also, new data found on Ec/N0 tests, justifies further research studies with the intention of validating the assumptions made in this work.