5 resultados para Medical cooperation.
em Instituto Politécnico do Porto, Portugal
Resumo:
This paper describes a Multi-agent Scheduling System that assumes the existence of several Machines Agents (which are decision-making entities) distributed inside the Manufacturing System that interact and cooperate with other agents in order to obtain optimal or near-optimal global performances. Agents have to manage their internal behaviors and their relationships with other agents via cooperative negotiation in accordance with business policies defined by the user manager. Some Multi Agent Systems (MAS) organizational aspects are considered. An original Cooperation Mechanism for a Team-work based Architecture is proposed to address dynamic scheduling using Meta-Heuristics.
Resumo:
This paper presents work in progress, to develop an efficient and economic way to directly produce Technetium 99metastable (99mTc) using low-energy cyclotrons. Its importance is well established and relates with the increased global trouble in delivering 99mTc to Nuclear Medicine Departments relying on this radioisotope. Since the present delivery strategy has clearly demonstrated its intrinsic limits, our group decided to follow a distinct approach that uses the broad distribution of the low energy cyclotrons and the accessibility of Molybdenum 100 (100Mo) as the Target material. This is indeed an important issue to consider, since the system here presented, named CYCLOTECH, it is not based on the use of Highly Enriched (or even Low Enriched) Uranium 235 (235U), so entirely complying with the actual international trends and directives concerning the use of this potential highly critical material. The production technique is based on the nuclear reaction 100Mo (p,2n) 99mTc whose production yields have already been documented. Until this moment two Patent requests have already been submitted (the first at the INPI, in Portugal, and the second at the USPTO, in the USA); others are being prepared for submission on a near future. The object of the CYCLOTECH system is to present 99mTc to Nuclear Medicine radiopharmacists in a routine, reliable and efficient manner that, remaining always flexible, entirely blends with established protocols. To facilitate workflow and Radiation Protection measures, it has been developed a Target Station that can be installed on most of the existing PET cyclotrons and that will tolerate up to 400 μA of beam by allowing the beam to strike the Target material at an adequately oblique angle. The Target Station permits the remote and automatic loading and discharge of the Targets from a carriage of 10 Target bodies. On other hand, several methods of Target material deposition and Target substrates are presented. The object was to create a cost effective means of depositing and intermediate the target material thickness (25 - 100μm) with a minimum of loss on a substrate that is able to easily transport the heat associated with high beam currents. Finally, the separation techniques presented are a combination of both physical and column chemistry. The object was to extract and deliver 99mTc in the identical form now in use in radiopharmacies worldwide. In addition, the Target material is recovered and can be recycled.
Resumo:
O calibre da artéria aorta torácica é avaliado em situações de suspeita de patologia ou em pacientes com pre-disposição para desenvolverem doenças vasculares. A medição das suas dimensões, em duas direcções diametralmente opostas e, assim, fulcral na avaliação desta estrutura. Para tal, o exame de primeira linha definido é a Angiografia por Tomografia Computorizada (Angio-TC), injectando-se um produto de contraste na veia radial que irá opacificar os vasos, permitindo a sua distinção das estruturas adjacentes. O presente trabalho, inserido na disciplina de Dissertação/ Projecto/ Estágio Profissional do Mestrado em Engenharia de Computação e Instrumentação Médica e com a cooperação da empresa Efficientia, foi sugerido pela equipa de Angio-TC do Centro Hospitalar de Vila Nova de Gaia (CHVNG) e tem por objectivo o desenvolvimento de uma aplicação para a medição e registo automático do diâmetro da aorta torácica em nove pontos anatómicos pre-definidos em imagens de Tomografia Computorizada (TC). A aplicação foi desenvolvida no ambiente integrado de processamento e análise de imagem, Fiji, sendo a metodologia composta pelas etapas de segmentação, desenho da linha central, determinação dos planos de cortes, segmentação e medição da aorta nos planos de corte. Os resultados obtidos pela metodologia proposta são concordantes com os obtidos por especialistas para o conjunto de teste utilizado neste trabalho.