22 resultados para Material necessity

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different problems are daily discuss on environmental aspects such acid rain, eutrophication, global warming and an others problems. Rarely do we find some discussions about phosphorus problematic. Through the years the phosphorus as been a real problem and must be more discussed. On this thesis was done a global material flow analysis of phosphorus, based on data from the year 2004, the production of phosphate rock in that year was 18.9 million tones, almost this amount it was used as fertilizer on the soil and the plants only can uptake, on average, 20% of the input of fertilizer to grow up, the remainder is lost for the phosphorus soil. In the phosphorus soil there is equilibrium between the phosphorus available to uptake from the plants and the phosphorus associate with other compounds, this equilibrium depends of the kind of soil and is related with the soil pH. A reserve inventory was done and we have 15,000 million tones as reserve, the amount that is economical available. The reserve base is estimated in 47,000 million tones. The major reserves can be found in Morocco and Western Sahara, United Sates, China and South Africa. The reserve estimated in 2009 was 15,000 million tone of phosphate rock or 1,963 million tone of P. If every year the mined phosphate rock is around 22 Mt/yr (phosphorus production on 2008 USGS 2009), and each year the consumption of phosphorus increases because of the food demand, the reserves of phosphate rock will be finished in about 90 years, or maybe even less. About the value/impact assessment was done a qualitative analysis, if on the future we don’t have more phosphate rock to produce fertilizers, it is expected a drop on the crops yields, each depends of the kind of the soil and the impact on the humans feed and animal production will not be a relevant problem. We can recovery phosphorus from different waste streams such as ploughing crop residues back into the soil, Food processing plants and food retailers, Human and animal excreta, Meat and bone meal, Manure fibre, Sewage sludge and wastewater. Some of these examples are developed in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho, realizado no âmbito da Tese de Mestrado, tem como principal objectivo estudar as características pozolânicas dos materiais da zona de Arganil para substituição parcial do cimento Portland com o objectivo de intensificar certas qualidades devido à diminuição da porosidade do betão. Estas qualidades são interessantes quando se procura maior durabilidade. Para tal, foram realizados diversos ensaios para a caracterização física, química e mineralógica dos produtos. Os metacaulinos utilizados foram obtidos de amostras de argila submetidas a calcinação (750oC, durante uma hora), processo que permitiu a desidroxilação quase total da matéria-prima, transformando esta numa fase amorfa e irreversível, com propriedades pozolânicas. São apresentados os resultados dos ensaios de caracterização da matéria-prima, das condições de calcinação e do produto resultante da desidroxilação, nomeadamente a determinação da pozolanicidade e superfície específica e das características fundamentais para a aplicabilidade do produto. Descreve ainda o emprego do metacaulino em betões de resistência convencional. Estudou-se a influência do emprego do metacaulino (15% de substituição de cimento, em massa) na resistência à flexão e à compressão (aos 28 dias) em argamassas e o emprego de metacaulino (10%, 15% e 20% de substituição de cimento, em massa) na resistência à compressão (3, 7 e 28 dias) no betão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho estudou-se um compósito de gesso FGD reforçado com fibras vegetais. As fibras utilizadas neste estudo são provenientes de bambu da espécie Phyllostachys edulis e foram trituradas até se obter uma granulometria apropriada à composição de uma pasta de gesso que permitisse a execução de placas de gesso laminado. As placas produzidas foram ensaiadas à flexão e posteriormente submetidas à análise de humidade para aferir a percentagem de água de cristalização nas amostras. Foram ainda produzidos provetes cúbicos com 7cm de aresta para permitira a execução de ensaio à compressão. Foram produzidos dois tipos de pastas, uma sem a adição de partículas de bambu (controlo) e outra com adição de 15% de partículas de bambu.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os desafios à engenharia moderna são cada vez maiores, pretendendo-se quase sempre obter estruturas mais leves, com propriedades mecânicas atrativas e muitas vezes com geometrias complexas. Com tais requisitos, um dos materiais que tem vindo a ter uma crescente aplicação é o material compósito. Contudo, no que toca ao cálculo estrutural destes materiais, tudo se torna mais complexo, já que são materiais que geralmente são formados por empilhamento de várias camadas de material heterogéneo, podendo estas encontrarem-se dispostas segundo diferentes orientações. Assim, a utilização de um software que permita a previsão das propriedades mecânicas de uma estrutura em material compósito através da micromecânica, a aplicação da Teoria Clássica dos Laminados e de um critério de rotura, como por exemplo o de Tsai-Hill, é fundamental para agilizar o processo de estudo da estrutura a fabricar. Para dar uma resposta a tal necessidade foi desenvolvida uma aplicação, em MATLAB® GUI, denominada CAFE – Composite Analysis For Engineers, com ambiente gráfico apelativo, que permite determinar todas as variáveis importantes no estudo de estruturas em material compósito. Esta aplicação visa suportar e agilizar a aprendizagem desta área do conhecimento, permitindo também o acesso ao código de cálculo por parte do utilizador, de modo a conhecerem-se as equações utilizadas e, eventualmente, ser alvo de futuros desenvolvimentos. O programa desenvolvido foi alvo de validação, recorrendo-se para tal, a uma comparação dos resultados obtidos entre o respetivo programa e por um outro programa de grande fiabilidade. Assim sendo, concluiu-se que o software CAFE apresenta resultados válidos, encontrando-se apto a ser utilizado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho foi elaborado no âmbito da Dissertação Final de Mestrado do curso de Engenharia Mecânica – Gestão Industrial do Instituto Superior de Engenharia do Porto. Este foi realizado numa empresa da indústria de pneus, a Continental Mabor S.A.. Nos dias atuais, a indústria esta cada vez mais competitiva, os custos e os prazos da entrega são cada vez mais reduzidos e a qualidade cada vez mais exigente, assim sendo, é imprescindível uma constante melhoria do sistema produtivo. Este fato fez com que o presente trabalho tivesse como principal objetivo determinar o estado atual e delinear um plano de melhoria para um equipamento (Extrusora de pisos nº6), recentemente instalado na fábrica mas oriundo de outra fábrica do grupo, recorrendo para tal ao Lean Manufacturing e a ferramentas que lhe estão associadas. Inicialmente realizou-se uma análise e diagnóstico ao processo de extrusão de pisos na Extrusora nº6, com o intuito de avaliar todas as suas ineficiências e ainda formular um plano de melhorias para a ineficiência de maior impacto no sistema produtivo. Esta análise foi realizada em diferentes turnos e diferentes equipas de trabalho de forma a se obter uma amostra mais representativa da realidade global. Após esta análise verificou-se que as principais ineficiências eram Setup, conformidade do material, dimensões e encravamentos, entre outros. Sendo que os Setup provocam um tempo de paragem de 101 minutos por turno, escolheu-se esta perturbação como o foco do plano de melhorias a realizar posteriormente. De forma a reduzir os tempos de mudança (Setup), o autor no presente trabalho utilizou ferramentas Lean Manufacturing, principalmente o SMED. Conjuntamente com o SMED ainda foram utilizadas outras ferramentas Lean Manufacturing tais como: 5S, Gestão Visual, Problem Solving e Normalização do Método de Trabalho. Após a implementação de todas estas ferramentas obteve-se uma redução de tempos de mudança de 43% com 1 operador e 71% com 2 operadores, ou seja, reduziu-se de 40,5 minutos gastos por turno para a mudança de fieira para 23,13 min e 11,79 min respetivamente, o que corresponde a um ganho monetário anual de 63.621€ ou 105.045€, respetivamente. Com este trabalho conclui-se que a utilização de ferramentas Lean Manufacturing contribuem para a redução dos desperdícios do processo produtivo. Por isso, espera-se que este estudo seja aplicado na Extrusora nº6 e nas restantes Extrusoras de pisos existentes na fábrica, e num futuro próximo que se realize estudos semelhantes em máquinas com diferentes funções.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics of carbon fibre reinforced laminates have widened their use from aerospace to domestic appliances, and new possibilities for their usage emerge almost daily. In many of the possible applications, the laminates need to be drilled for assembly purposes. It is known that a drilling process that reduces the drill thrust force can decrease the risk of delamination. In this work, damage assessment methods based on data extracted from radiographic images are compared and correlated with mechanical test results—bearing test and delamination onset test—and analytical models. The results demonstrate the importance of an adequate selection of drilling tools and machining parameters to extend the life cycle of these laminates as a consequence of enhanced reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O transporte de cargas é uma tarefa comum para crianças, adolescentes e adultos, pela necessidade de transferência diária de objetos pessoais, livros e artigos de papelaria para os locais de trabalho ou escolas. Diversos autores apontam que o peso carregado durante transporte de material é o principal responsável pelo aparecimento de dor lombar. Deste modo é importante o constante estudo da temática para a definição recomendações e limites. O presente estudo teve como principais objetivos a caraterização da problemática associada à utilização de mochilas e a determinação do Peso Máximo Aceitável (PMA) e do Índice de Esforço Percebido (IEP) para a tarefa de transporte de mochilas, através da abordagem psicofísica. O estudo foi desenvolvido com estudantes do 7º, 8º e 9º ano de escolaridade e, foi dividido em duas fases. Na 1ª fase foram aplicados questionários para a análise da problemática associada à utilização de diferentes tipos de mochilas escolares. Nesta fase, foram incluídos aspetos associados à identificação do tipo de mochila mais utilizada, as rotinas e hábitos dos estudantes e as características da mochila utilizada. Verificou-se que os estudantes utilizam, maioritariamente, a mochila de duas alças para transporte de material escolar. Posteriormente foram efetuadas medições de peso da mochila, altura e peso aos 131 estudantes que constituíram a amostra da 1º fase. O principal objetivo deste ponto foi identificar o tipo de mochila habitualmente utilizada pelos estudantes assim como, o peso transportado nas mochilas. Na 2ª fase foi efetuado um estudo para a determinação do PMA e do IEP, através da abordagem psicofísica, para a tarefa de transporte de mochila, considerando-se uma amostra constituída por 10 estudantes. Para este estudo, apenas foi considerada a mochila mais frequentemente utilizada, identificada na 1º fase. A tarefa consistiu no transporte da mochila nos dois ombros e com as alças devidamente ajustadas ao corpo, num percurso pré-definido, de acordo com o procedimento experimental. Os resultados indicaram que nem todos os estudantes transportam mochilas com pesos dentro das recomendações da Organização Mundial de Saúde. O PMA determinado pelos estudantes foi de 6.8 kg para a mochila de duas alças e a região dos ombros foi identificada durante todo o estudo como sendo a que apresentava maior intensidade de dor durante o transporte da mochila.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To date, glass fibre reinforced polymer (GFRP) waste recycling is very limited and restricted by thermoset nature of binder matrix and lack of economically viable enduse applications for the recyclates. In this study, efforts were made in order to recycle grinded GFRP waste proceeding from pultrusion production scrap, into new and sustainable composite materials. For this purpose, GFRP waste recyclates, a mix of powdered and fibrous materials, were incorporated into polyester based mortars as fine aggregate and filler replacements, at different load contents (between 4% up to 12% of total mass) and particle size distributions. Potential recycling solution was assessed by mechanical behaviour of resultant GFRP waste modified polymer mortars. Test results revealed that GFRP waste filled polymer mortars present improved flexural and compressive behaviour over unmodified polyester based mortars, thus indicating the feasibility of GFRP waste reuse in concrete-polymer composites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass fibre-reinforced plastics (GFRP) have been considered inherently difficult to recycle due to both: cross-linked nature of thermoset resins, which cannot be remoulded, and complex composition of the composite itself. Presently, most of the GFRP waste is landfilled leading to negative environmental impacts and supplementary added costs. With an increasing awareness of environmental matters and the subsequent desire to save resources, recycling would convert an expensive waste disposal into a profitable reusable material. In this study, efforts were made in order to recycle grinded GFRP waste, proceeding from pultrusion production scrap, into new and sustainable composite materials. For this purpose, GFRP waste recyclates, were incorporated into polyester based mortars as fine aggregate and filler replacements at different load contents and particle size distributions. Potential recycling solution was assessed by mechanical behaviour of resultant GFRP waste modified polymer mortars. Results revealed that GFRP waste filled polymer mortars present improved flexural and compressive behavior over unmodified polyester based mortars, thus indicating the feasibility of the GFRP industrial waste reuse into concrete-polymer composite materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente artigo apresenta e discute alguns resultados de uma investigação sociológica em curso acerca das transformações sociais resultantes das intervenções urbanísticas e habitacionais promovidas pelo Estado no centro do Porto ao longo do último meio século. A investigação em causa é bastante abrangente – quer do ponto de vista do horizonte temporal que abarca, quer do ponto de vista temático –, pelo que neste artigo as atenções estarão centradas na enunciação, a partir da reconstituição empírica e analítica dos pontos de vista de educadores e professores de um agrupamento vertical de escolas, de algumas das dinâmicas recentes da relação das famílias com a instituição escolar em contextos sociais caracterizados por níveis elevados de privação económica e cultural e por processos vincados de segregação física e simbólica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work uses surface imprinting to design a novel smart plastic antibodymaterial (SPAM) for Haemoglobin (Hb). Charged binding sites are described here for the first time to tailor plastic antibody nanostructures for a large size protein such as Hb. Its application to design small, portable and low cost potentiometric devices is presented. The SPAM material was obtained by linking Hb to silica nanoparticles and allowing its ionic interaction with charged vinyl monomers. A neutral polymeric matrix was created around these and the imprinted protein removed. Additional materials were designed in parallel acting as a control: a neutral imprinted material (NSPAM), obtained by removing the charged monomers from the procedure, and the Non-Imprinted (NI) versions of SPAM and NSPAM by removing the template. SEM analysis confirmed the surface modification of the silica nanoparticles. All materials were mixed with PVC/plasticizer and applied as selective membranes in potentiometric transduction. Electromotive force (emf) variations were detected only for selective membranes having a lipophilic anionic additive in the membrane. The presence of Hb inside these membranes was evident and confirmed by FTIR, optical microscopy and Raman spectroscopy. The best performance was found for SPAM-based selective membranes with an anionic lipophilic additive, at pH 5. The limits of detection were 43.8 mg mL 1 and linear responses were obtained down to 83.8 mg mL 1, with an average cationic slope of +40 mV per decade. Good selectivity was also observed against other coexisting biomolecules. The analytical application was conducted successfully, showing accurate and precise results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel reusable molecularly imprinted polymer (MIP) assembled on a polymeric layer of carboxylated poly(vinyl chloride) (PVCsingle bondCOOH) for myoglobin (Myo) detection was developed. This polymer was casted on the gold working area of a screen printed electrode (Au-SPE), creating a novel disposable device relying on plastic antibodies. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FTIR) studies confirmed the surface modification. The MIP/Au-SPE devices displayed a linear behaviour in EIS from 0.852 to 4.26 μg mL−1, of positive slope 6.50 ± 1.48 (kΩ mL μg−1). The limit of detection was 2.25 μg mL−1. Square wave voltammetric (SWV) assays were made in parallel and showed linear responses between 1.1 and 2.98 μg mL−1. A current decrease was observed against Myo concentration, producing average slopes of −0.28 ± 0.038 μA mL μg−1. MIP/Au-SPE also showed good results in terms of selectivity. The error% found for each interfering species were 7% for troponin T (TnT), 11% for bovine serum albumin (BSA) and 2% for creatine kinase MB (CKMB), respectively. Overall, the technical modification over the Au-SPE was found a suitable approach for screening Myo in biological fluids.