39 resultados para Masonry walls
em Instituto Politécnico do Porto, Portugal
Resumo:
Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.
Resumo:
During the last years, several studies have been made aiming to assess the out-of-plane seismic response of unreinforced stone masonry structures. This fact led to the development of a wide variety of models and approaches, ranging from simple kinematic based analytical models up to complex numerical simulations. Nevertheless, for the sake of simplicity, the out-of-plane seismic response of a masonry wall pier may be obtained by means of a simple single-degree-of-freedom system while still providing good results. In fact, despite the assumptions associated with such a simple formulation, it is also true that the epistemic uncertainty inherent with the selection of appropriate input parameters in more complex models may render them truly ineffective. In this framework, this paper focuses on the study of the out-of-plane bending of unreinforced stone masonry walls (cantilevers) by proposing a simplified analytical approach based on the construction of a linearized four-branch model, which is used to characterize the linear and nonlinear response of such structural elements through an overturning moment-rotation relationship. The formulation of the four-branch model is presented and described in detail and the meaningful parameters used for its construction are obtained from a set of experimental laboratory tests performed on six full-scale unreinforced regular sacco stone masonry specimens. Moreover, a parametric analysis aiming to evaluate the effect of these parameters’ variation on the final configuration of the model is presented and critically discussed. Finally, the results obtained from the application of the developed four-branch model on real unreinforced regular sacco stone masonry walls are thoroughly analysed and the main conclusions obtained from its application are summarized.
Resumo:
O conceito de atirantamento surgiu no contexto de promover a interação global dos edifícios, nomeadamente, estabelecer as referidas ligações, de modo a prevenir o derrubamento para o exterior das paredes de fachada, perante a ocorrência de ação sísmica ou assentamento das fundações. Neste sentido, o presente trabalho tem como objetivo, estudar o comportamento dos atirantamentos ancorados no plano perpendicular das fachadas, quando solicitados à tração. No entanto, como as alvenarias são elementos heterogéneos, houve necessidade de desarticular os atirantamentos e estudar cada uma das partes que o compõe: tirantes injetados em alvenarias e sistemas de ancoragem. Em primeiro lugar, foi elaborado um estudo preliminar sobre tirantes injetados em alvenarias, o qual incidiu no seu dimensionamento, na análise de sensibilidade, apresentação de um caso de estudo e comparação de resultados. Numa segunda fase fez-se uma revisão bibliográfica dos tipos de Sistemas de Ancoragens mais comuns, onde foram mencionados alguns aspetos, nomeadamente a importância, o objetivo e condições da sua aplicação. Por último, associaram-se as duas componentes e foram estudados os Atirantamentos. Fezse um estudo da sua utilização e do seu interesse de aplicação. Foi também analisada uma forma de metodologia de dimensionamento, quando inseridos em alvenarias de tijolo e pedra. Finalizado este estudo foram traçadas as conclusões e sugeridas perspetivas futuras.
Resumo:
Um incêndio é algo difícil de prever, assim como a sua consequência nos elementos de construção. Dessa forma, ao longo das últimas décadas, os elementos de construção têm sido alvo de diversos estudos a fim de avaliar os seus comportamentos quando solicitados em situação de incêndio. O International Building Code (IBC) descreve um método de cálculo analítico para a determinação da resistência ao fogo dos elementos da construção de acordo com os procedimentos de teste estabelecidos na ASTM E119 (Standard Test Methods for Fire Tests of Building Construction and Materials). Nesta dissertação foi feita uma análise desse método, que se mostrou inadequado para estimar a resistência ao fogo das alvenarias, sem função estrutural, de blocos cerâmicos e blocos de betão, uma vez que despreza qualquer efeito do ar no interior das mesmas. No seguimento desta análise, é apresentado um desenvolvimento do método descrito tendo em conta o efeito do ar. Depois de uma análise aos vários tipos de blocos cerâmicos e de betão com diferentes dimensões e geometrias foi possível obter uma relação entre a espessura equivalente de ar existente num bloco e a sua respectiva resistência ao fogo, de modo a serem obtidos os valores descritos na normalização existente. O efeito do ar mostrou ter uma maior influência na resistência ao fogo nas alvenarias constituídas por blocos cerâmicos de furação vertical, já que a sua geometria caracterizada por um elevado número de pequenos alvéolos contribui para o aumento do isolamento térmico, e consequentemente da sua resistência ao fogo. Nas alvenarias rebocadas os valores da resistência ao fogo aumentam cerca de 50%, quando revestidos com argamassa de cimento, e 70% quando revestidos com gesso, logo, o emprego de revestimentos representam uma boa alternativa para aumentar a resistência ao fogo.
Resumo:
Although the issue of the out-of-plane response of unreinforced masonry structures under earthquake excitation is well known with consensus among the research community, this issue is simultaneously one of the more complex and most neglected areas on the seismic assessment of existing buildings. Nonetheless, its characterization should be found on the solid knowledge of the phenomenon and on the complete understanding of methodologies currently used to describe it. Based on this assumption, this article presents a general framework on the issue of the out-of-plane performance of unreinforced masonry structures, beginning with a brief introduction to the topic, followed by a compact state of art in which the principal methodologies proposed to assess the out-of-plane behavior of unreinforced masonry structures are presented. Different analytical approaches are presented, namely force and displacement-based, complemented with the presentation of existing numerical tools for the purpose presented above. Moreover, the most relevant experimental campaigns carried out in order to reproduce the phenomenon are reviewed and briefly discussed.
Resumo:
The seismic assessment of the local failure modes in existing masonry buildings is currently based on the identification of the so-called local mechanisms, often associated with the out-of-plane wall behavior, whose stability is evaluated by static force-based approaches and, more recently, by some displacement-based proposals. Local mechanisms consist of kinematic chains of masonry portions, often regarded as rigid bodies, with geometric nonlinearity and concentrated nonlinearity in predefined contact regions (unilateral no-tension behavior, possible sliding with friction). In this work, the dynamic behavior of local mechanisms is simulated through multi-body dynamics, to obtain the nonlinear response with efficient time history analyses that directly take into account the characteristics of the ground motion. The amplification/filtering effects of the structure are considered within the input motion. The proposed approach is validated with experimental results of two full-scale shaking-table tests on stone masonry buildings: a sacco-stone masonry façade tested at Laboratório Nacional de Engenharia Civil and a two-storey double-leaf masonry building tested at European Centre for Training and Research in Earthquake Engineering (EUCENTRE).
Resumo:
The Azores archipelago is a zone with a vast cultural heritage, presenting a building stock mainly constructed in traditional stone masonry. It is known that this type of construction exhibits poor behaviour under seismic excitations; however it is extensively used in seismic prone areas, such as this case. The 9th of July of 1998 earthquake was the last seismic event in the islands, leaving many traditional stone constructions severely damaged or totally destroyed. This scenario led to an effort by the local government of improving the seismic resistance of these constructions, with the application of several reinforcement techniques. This work aims to study some of the most used reinforcement schemes after the 1998 earthquake, and to assess their effectiveness in the mitigation of the construction’s seismic vulnerability. A brief evaluation of the cost versus benefit of these retrofitting techniques is also made, seeking to identify those that are most suitable for each building typology. Thus, it was sought to analyze the case of real structures with different geometrical and physical characteristics, by establishing a comparison between the seismic performance of reinforced and non-reinforced structures. The first section contains the analysis of a total of six reinforcement scenarios for each building chosen. Using the recorded 1998 earthquake accelerograms, a linear time-history analysis was performed for each reinforcement scenario. A comparison was then established between the maximum displacements, inter-storey drift and maximum stress obtained, in order to evaluate the global seismic response of each reinforced structure. In the second part of the work, the examination of the performance obtained in the previous section, in relation to the cost of implementing each reinforcement technique, allowed to draw conclusions concerning the viability of implementing each reinforcement method, based on the book value of the buildings in study.
Resumo:
Today, business group decision making is an extremely important activity. A considerable number of applications and research have been made in the past years in order to increase the effectiveness of decision making process. In order to support the idea generation process, IGTAI (Idea Generation Tool for Ambient Intelligence) prototype was created. IGTAI is a Group Decision Support System designed to support any kind of meetings namely distributed, asynchronous or face to face. It aims at helping geographically distributed (or not) people and organizations in the idea generation task, by making use of pervasive hardware in a meeting room, expanding the meeting beyond the room walls by allowing a ubiquitous access through different kinds of equipment. This paper focus on the research made to build IGTAI prototype, its architecture and its main functionalities, namely the support given in the different phases of the idea generation meeting.
Resumo:
In the work of Paul Auster (Newark, 1947 - ), we find two main themes: the sense of loss and existential drift and the loneliness of the individual fully committed to the work of writing, as if he had been confined to the book that commands his life. However, this second theme is clearly the dominant one because the character's space of solitude may include its own wandering, because this wandering is also often performed inside the four walls of a room, just like it is narrated inside the space of the page and the book. Both in his poetry, essays and fiction, Auster seems to face the work of writing as an actual physical effort of effective construction, as if the words that are aligned in the poem-text were stones to place in a row when building a wall or some other structure in stone.
Resumo:
Mestrado em Engenharia Química
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.
Resumo:
Como o sector cerâmico é um consumidor intensivo de energia, este trabalho teve como objectivo principal a elaboração de um plano de optimização do desempenho energético da olaria número três da Fábrica Cerâmica de Valadares. Para o efeito, efectuou-se o levantamento energético desta fracção autónoma. O valor total obtido para os ganhos térmicos foi de 8,7x107 kJ/dia, sendo 82% desta energia obtida na combustão do gás natural. Por outro lado, as perdas energéticas rondam os 8,2x107 kJ/dia, sendo o ar de exaustão e a envolvente os principais responsáveis, com um peso de 42 % e 38%, respectivamente. Tendo em conta estes valores, estudaram-se várias medidas de isolamento da cobertura, pavimento, paredes e saída de ar através de fendas do edifício. No caso do isolamento da cobertura sugeriu-se a substituição das telhas de fibrocimento e do isolamento actualmente existentes por painéis sandwich de cobertura. Esta acção permite uma poupança de 64.796€/ano, com um investimento de 57.029€ e o seu período de retorno de 0,9 anos. O Valor Actualizado Líquido (VAL) no 5º ano foi de 184.069€, com uma Taxa Interna de Rentabilidade (TIR) de 92%. Para isolar o pavimento, sugeriu-se a utilização de placas de poliuretano expandido (PU) de 20mm de espessura. Assim, consegue-se uma poupança de 7.442 €/ano, com um investimento de 21.708€, e um tempo de retorno 2,9 anos. No final do 5º ano de vida útil do projecto, o VAL é de 4.070€ e a TIR 7%. Relativamente ao isolamento das paredes e pilares, sugeriu-se a utilização de placas de PU (30mm), recobertas com chapa de ferro galvanizado. O tempo de retorno do investimento é de 1,5 anos, uma vez que, o investimento é de 13.670€ e a poupança anual será de 9.183€. Esta solução apresenta no último ano um VAL de 12.835€ e uma TIR de 22%. No isolamento das fendas do edifício, sugeriu-se a redução de 20% da sua área livre. Esta medida de optimização implica um investimento de 8.000€, revelando-se suficientemente eficaz, pois apresenta um tempo de retorno de 0,67 anos. O VAL e a TIR da solução no último ano de vida útil do projecto de investimento são de 36.835€ e 35%, respectivamente. Por fim, sugeriu-se ainda a instalação de um sistema de controlo que visa o aproveitamento de ar quente proveniente do forno, instalado no piso inferior à olaria, para pré-aquecer o ar alimentado aos geradores de calor. Esta medida implicaria um investimento de 4.000€, com um tempo de retorno de 2,4 anos e uma poupança anual é de 1.686€. O investimento é aconselhável, já que, no 5º ano, o VAL é de 1.956€ e a TIR é de 17%.
Resumo:
Ainda antes da invenção da escrita, o desenho foi utilizado para descrever a realidade, tendo evoluído ao longo dos tempos, ganhando mais qualidade e pormenor e recorrendo a suportes cada vez mais evoluídos que permitissem a perpetuação dessa imagem: dessa informação. Desde as pinturas rupestres, nas paredes de grutas paleolíticas, passando pelos hieróglifos, nos templos egípcios, nas gravuras das escrituras antigas e nos quadros sobre tela, a intenção sempre foi a de transmitir a informação da forma mais directa e perceptível por qualquer indivíduo. Nos dias de hoje as novas tecnologias permitem aceder à informação com uma facilidade nunca antes vista ou imaginada, estando certamente ainda por descobrir outras formas de registar e perpetuar a informação para as gerações vindouras. A fotografia está na origem das grandes evoluções da imagem, permitindo capturar o momento, tornando-o “eterno”. Hoje em dia, na era da imagem digital, além de se mostrar a realidade, é possível incorporar na imagem informação adicional, de modo a enriquecer a experiência de visualização e a maximizar a aquisição do conhecimento. As possibilidades da visualização em três dimensões (3D) vieram dar o realismo que faltava ao formato de fotografia original. O 3D permite a imersão do espectador no ambiente que, a própria imagem retrata, à qual se pode ainda adicionar informação escrita ou até sensorial como, por exemplo, o som. Esta imersão num ambiente tridimensional permite ao utilizador interagir com a própria imagem através da navegação e exploração de detalhes, usando ferramentas como o zoom ou ligações incorporados na imagem. A internet é o local onde, hoje em dia, já se disponibilizam estes ambientes imersivos, tornando esta experiência muita mais acessível a qualquer pessoa. Há poucos anos ainda, esta prática só era possível mediante o recurso a dispositivos especificamente construídos para o efeito e que, por isso, apenas estavam disponíveis a grupos restritos de utilizadores. Esta dissertação visa identificar as características de um ambiente 3D imersivo e as técnicas existentes e possíveis de serem usadas para maximizar a experiência de visualização. Apresentar-se-ão algumas aplicações destes ambientes e sua utilidade no nosso dia-a-dia, antevendo as tendências futuras de evolução nesta área. Serão apresentados exemplos de ferramentas para a composição e produção destes ambientes e serão construídos alguns modelos ilustrativos destas técnicas, como forma de avaliar o esforço de desenvolvimento e o resultado obtido, comparativamente com formas mais convencionais de transmitir e armazenar a informação. Para uma avaliação mais objectiva, submeteram-se os modelos produzidos à apreciação de diversos utilizadores, a partir da qual foram elaboradas as conclusões finais deste trabalho relativamente às potencialidades de utilização de ambientes 3D imersivos e suas mais diversas aplicações.