14 resultados para L71 - Mining, Extraction, and Refining:

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Soil vapor extraction (SVE) is an efficient, well-known and widely applied soil remediation technology. However, under certain conditions it cannot achieve the defined cleanup goals, requiring further treatment, for example, through bioremediation (BR). The sequential application of these technologies is presented as a valid option but is not yet entirely studied. This work presents the study of the remediation of ethylbenzene (EB)-contaminated soils, with different soil water and natural organic matter (NOMC) contents, using sequential SVE and BR. The obtained results allow the conclusion that: (1) SVE was sufficient to reach the cleanup goals in 63% of the experiments (all the soils with NOMC below 4%), (2) higher NOMCs led to longer SVE remediation times, (3) BR showed to be a possible and cost-effective option when EB concentrations were lower than 335 mg kgsoil −1, and (4) concentrations of EB above 438 mg kgsoil −1 showed to be inhibitory for microbial activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A methodology based on microwave-assisted extraction (MAE) and LC with fluorescence detection (FLD) was investigated for the efficient determination of 15 polycyclic aromatic hydrocarbons (PAHs) regarded as priority pollutants by the US Environmental Protection Agency and dibenzo(a,l)pyrene in atmospheric particulate samples. PAHs were successfully extracted from real outdoor particulate matter (PM) samples with recoveries ranging from 81.4±8.8 to 112.0±1.1%, for all the compounds except for naphthalene (62.3±18.0%) and anthracene (67.3±5.7%), under the optimum MAE conditions (30.0 mL of ACN for 20 min at 110ºC). No clean-up steps were necessary prior to LC analysis. LOQs ranging from 0.0054 ng/m3 for benzo( a)anthracene to 0.089 ng/m3 for naphthalene were reached. The validated MAE methodology was applied to the determination of PAHs from a set of real world PM samples collected in Oporto (north of Portugal). The sum of particulate-bound PAHs in outdoor PM ranged from 2.5 and 28 ng/m3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A methodology for the determination of the pesticide chlorfenvinphos by microwave-assisted solvent extraction and square-wave cathodic stripping voltammetry at a mercury film ultramicroelectrode in soil samples is proposed. Optimization of microwave solvent extraction performed with two soils, selected for having significantly different properties, indicated that the optimum solvent for extracting chlorfenvinphos is hexane-acetone (1:1, v/v). The voltammetric procedure is based on controlled adsorptive accumulation of the insecticide at the potential of -0.60 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 6.2). The detection limit obtained for a 10 s collection time was 3.0 x 10-8 mol l-1. The validity of the developed methodology was assessed by recovery experiments at the 0.100 µg g-1 level. The average recoveries and standard deviations for the global procedure reached byMASE-square-wave voltammetry were 90.2±2.8% and 92.1±3.4% for type I (soil rich in organic matter) and type II (sandy soil) samples, respectively. These results are in accordance to the expected values which show that the method has a good accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical multiresidue method for the simultaneous determination of seven pesticides in fresh vegetable samples, namely, courgette (Cucurbita pepo), cucumber (Cucumis sativus), lettuce (Lactuca sativa, Romaine and Iceberg varieties) and peppers (Capsicum sp.) is described. The procedure, based on microwave-assisted extraction (MAE) and analysis by liquid chromatography– photodiode array (LC–PDA) detection was applied to four carbamates (carbofuran, carbaryl, chlorpropham and EPTC) and three urea pesticides (monolinuron, metobromuron and linuron). Extraction solvent and the addition of anhydrous sodium sulphate to fresh vegetable homogenate before MAE were the parameters optimised for each commodity. Recovery studies were performed using spiked samples in the range 250–403 µgkg- 1 in each pesticide. The pesticide residues were extracted using 20mL acetonitrile at 60 ºC, for 10 min. Acceptable recoveries and RSDs were attained (overall average recovery of 77.2% and RSDs are lower than 11%). Detection limits ranged between 5.8 µgkg- 1 for carbaryl to 12.3 µgkg- 1 for carbofuran. The analytical protocol was applied for quality control of 41 fresh vegetable samples bought in Oporto Metropolitan Area (North Portugal). None of the samples contained any detectable amounts of the studied compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we sought to assess the applicability of GC–MS/MS for the identification and quantification of 36 pesticides in strawberry from integrated pest management (IPM) and organic farming (OF). Citrate versions of QuEChERS (quick, easy, cheap, effective, rugged and safe) using dispersive solid-phase extraction (d-SPE) and disposable pipette extraction (DPX) for cleanup were compared for pesticide extraction. For cleanup, a combination of MgSO4, primary secondary amine and C18 was used for both the versions. Significant differences were observed in recovery results between the two sample preparation versions (DPX and d-SPE). Overall, 86% of the pesticides achieved recoveries (three spiking levels 10, 50 and 200 µg/kg) in the range of 70–120%, with <13% RSD. The matrix effects were also evaluated in both the versions and in strawberries from different crop types. Although not evidencing significant differences between the two methodologies were observed, however, the DPX cleanup proved to be a faster technique and easy to execute. The results indicate that QuEChERS with d-SPE and DPX and GC–MS/MS analysis achieved reliable quantification and identification of 36 pesticide residues in strawberries from OF and IPM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An accurate and sensitive method for determination of 18 polycyclic aromatic hydrocarbons (PAHs) (16 PAHs considered by USEPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) in fish samples was validated. Analysis was performed by microwave-assisted extraction and liquid chromatography with photodiode array and fluorescence detection. Response surface methodology was used to find the optimal extraction parameters. Validation of the overall methodology was performed by spiking assays at four levels and using SRM 2977. Quantification limits ranging from 0.15–27.16 ng/g wet weight were obtained. The established method was applied in edible tissues of three commonly consumed and commercially valuable fish species (sardine, chub mackerel and horse mackerel) originated from Atlantic Ocean. Variable levels of naphthalene (1.03–2.95 ng/g wet weight), fluorene (0.34–1.09 ng/g wet weight) and phenanthrene (0.34–3.54 ng/g wet weight) were detected in the analysed samples. None of the samples contained detectable amounts of benzo[a]pyrene, the marker used for evaluating the occurrence and carcinogenic effects of PAHs in food.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a novel approach to explore DNA nucleotide sequence data, aiming to produce high-level categorical and structural information about the underlying chromosomes, genomes and species. The article starts by analyzing chromosomal data through histograms using fixed length DNA sequences. After creating the DNA-related histograms, a correlation between pairs of histograms is computed, producing a global correlation matrix. These data are then used as input to several data processing methods for information extraction and tabular/graphical output generation. A set of 18 species is processed and the extensive results reveal that the proposed method is able to generate significant and diversified outputs, in good accordance with current scientific knowledge in domains such as genomics and phylogenetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proteins are biochemical entities consisting of one or more blocks typically folded in a 3D pattern. Each block (a polypeptide) is a single linear sequence of amino acids that are biochemically bonded together. The amino acid sequence in a protein is defined by the sequence of a gene or several genes encoded in the DNA-based genetic code. This genetic code typically uses twenty amino acids, but in certain organisms the genetic code can also include two other amino acids. After linking the amino acids during protein synthesis, each amino acid becomes a residue in a protein, which is then chemically modified, ultimately changing and defining the protein function. In this study, the authors analyze the amino acid sequence using alignment-free methods, aiming to identify structural patterns in sets of proteins and in the proteome, without any other previous assumptions. The paper starts by analyzing amino acid sequence data by means of histograms using fixed length amino acid words (tuples). After creating the initial relative frequency histograms, they are transformed and processed in order to generate quantitative results for information extraction and graphical visualization. Selected samples from two reference datasets are used, and results reveal that the proposed method is able to generate relevant outputs in accordance with current scientific knowledge in domains like protein sequence/proteome analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An extraction-anodic adsorptive stripping voltammetric procedure using microwave-assisted solvent extraction and a gold ultramicroelectrode was developed for determining the pesticide ametryn in soil samples. The method is based on the use of acetonitrile as extraction solvent and on controlled adsorptive accumulation of the herbicide at the potential of 0.50 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 3.3). Soil sample extracts were analysed directly after drying and redissolution with the supporting electrolyte but without other pre-treatment. The limit of detection obtained for a 10 s collection time was 0.021 µg g-1. Recovery experiments for the global procedure, at the 0.500 µg g-1 level, gave satisfactory mean and standard deviation results which were comparable to those obtained by HPLC with UV detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical methodology for the simultaneous determination of seven pharmaceuticals and two metabolites belonging to the non-steroidal anti-inflammatory drugs (NSAIDs) and analgesics therapeutic groups was developed based on off-line solid-phase extraction and ultra-high performance liquid chromatography coupled to tandem mass spectrometry (SPE–UHPLC–MS/MS). Extraction conditions were optimized taking into account parameters like sorbent material, sample volume and sample pH. Method detection limits (MDLs) ranging from 0.02 to 8.18 ng/L were obtained. This methodology was successfully applied to the determination of the selected pharmaceuticals in seawater samples of Atlantic Ocean in the Northern Portuguese coast. All the pharmaceuticals have been detected in the seawater samples, with pharmaceuticals like ibuprofen, acetaminophen, ketoprofen and the metabolite hydroxyibuprofen being the most frequently detected at concentrations that can reach some hundreds of ng/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synthetic pyrethroids are pesticides derived from naturally occurring pyrethrins, taken from pyrethrum of dried Chrysanthemum flowers. Pyrethroid insecticides are one of the most commonly used residential and agricultural insecticides. Many pyrethroids can significantly harm the nervous system. Permethrin could be one of the factors involved in the onset of neurodegenerative diseases. The present study aims to evaluate in brain, the effect that can induce the exposure to permethrin, during early life of female rats (from 6 to 21 days of life). Therefore, have been examined the concentrations of permethrin and its main metabolite (3-PBA) in the brain and urine in female rats sacrificed the day after and 14 days after treating. The different concentrations of permethrin and 3-PBA (after 24h and after 14 days in the end of treatment) were obtained using two different methods. The evaluation of permethrin by liquid-liquid extraction and GC-ECD was performed. The levels of the 3-PBA (in urine and brains) were obtained by SPE procedure and GC-MS using the 2- PBA as internal standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hoje em dia algumas das principais preocupações que se tem na exploração a céu aberto, são a diminuição de custos e a máxima rentabilidade dos equipamentos. São dois aspectos que estão interligados uma vez que a rentabilização dos equipamentos tem como resultado directo a diminuição dos custos de todas as operações inerentes à exploração a céu aberto e, consequentemente, a diminuição dos custos finais de produção. É por essa lógica de pensamento que se procurou perceber e compreender o funcionamento e a rentabilidade dos equipamentos em função dos diferentes estados de fracturação do maciço rochoso. Este estudo foi realizado numa pedreira a norte de Portugal e complementa outros estudos já realizados, com o objectivo de definir características do diagrama de fogo que assegurem a maior rentabilidade da referida exploração. O estudo baseia-se em determinar os rendimentos da pá carregadora calculando os tempos de ciclo, isto é, o tempo que a pá demorou a carregar, a movimentar e a descarregar o material desmontado dos vários rebentamentos. Calculou-se o rendimento do martelo demolidor na fragmentação de grandes blocos, que não entrariam directamente no britador primário, o qual também foi alvo de estudo, nomeadamente, no que diz respeito aos tempos de encravamento e de britagem, onde se tentou correlacionar esses tempos com os vários desmontes e estimou-se o consumo de energia do britador primário utilizando a equação de Bond. Por fim, realizou-se um estudo comparativo do consumo energético entre as várias fases da exploração a céu aberto. Foram realizados levantamentos geológico-geotécnicos de superfícies de descontinuidades recorrendo à técnica de amostragem linear nas superfícies do maciço rochoso para perceber o tipo de fragmentação e orientação do mesmo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Um túnel é uma obra subterrânea dimensionada com o objetivo de satisfazer diversas necessidades num mundo onde o planeamento urbano e a gestão de espaços ganha cada vez mais importância. A execução de este género de obras de engenharia pode ter várias finalidades, que podem ir desde a construção/reabilitação de redes de saneamento, abastecimento de água ou gás (túneis de pequeno diâmetro) até à construção/modernização de redes pedonais, rodoviárias ou ferroviárias, galerias mineiras, tuneis para barragens, etc. (túneis de grande diâmetro). As tuneladoras são uma das ferramentas de desmonte mais utilizadas na execução de obras subterrâneas. Existem no mercado vários tipos de máquinas tuneladoras, a sua escolha e dimensionamento depende de diversos fatores que devem ser cuidadosamente analisados, nomeadamente tipo de terreno a escavar, presença ou não de água na zona de escavação, dureza e/ou abrasividade das formações a atravessar, etc. Será feita uma abordagem aos princípios de funcionamento de este tipo de equipamentos, indicando o seu campo de aplicação dentro da respetiva tecnologia de escavação onde se inserem. Finalmente será desenvolvido o caso da empreitada: “Execução da Travessia do Rio Ave, da Estação Elevatória de Vila do Conde e dos Sistemas Elevatória da Aguçadoura e da Apúlia 4 - AR 44.0.08”, onde em alternativa ao desvio provisório do Rio Ave em Vila do Conde foi projetada a execução de duas travessias no diâmetro 1200 mm, uma delas escavadas maioritariamente em terreno aluvionar brando e a outra em terreno rochoso duro e abrasivo com recurso, em ambos casos, à utilização de máquina tuneladora. Através da avaliação do desempenho do equipamento escolhido para execução de este trabalho será estudada a eficiência da utilização deste tipo de equipamento. Com o objetivo de mostrar os custos associados à execução de obras de escavação subterrânea com recurso a utilização de máquinas tuneladoras, será feita uma análise económica e comparativa relativa aos dois casos de obra apresentados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This document presents a tool able to automatically gather data provided by real energy markets and to generate scenarios, capture and improve market players’ profiles and strategies by using knowledge discovery processes in databases supported by artificial intelligence techniques, data mining algorithms and machine learning methods. It provides the means for generating scenarios with different dimensions and characteristics, ensuring the representation of real and adapted markets, and their participating entities. The scenarios generator module enhances the MASCEM (Multi-Agent Simulator of Competitive Electricity Markets) simulator, endowing a more effective tool for decision support. The achievements from the implementation of the proposed module enables researchers and electricity markets’ participating entities to analyze data, create real scenarios and make experiments with them. On the other hand, applying knowledge discovery techniques to real data also allows the improvement of MASCEM agents’ profiles and strategies resulting in a better representation of real market players’ behavior. This work aims to improve the comprehension of electricity markets and the interactions among the involved entities through adequate multi-agent simulation.