5 resultados para High Order

em Instituto Politécnico do Porto, Portugal


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents the measurement, frequency-response modeling and identification, and the corresponding impulse time response of the human respiratory impedance and admittance. The investigated adult patient groups were healthy, diagnosed with chronic obstructive pulmonary disease and kyphoscoliosis, respectively. The investigated children patient groups were healthy, diagnosed with asthma and cystic fibrosis, respectively. Fractional order (FO) models are identified on the measured impedance to quantify the respiratory mechanical properties. Two methods are presented for obtaining and simulating the time-domain impulse response from FO models of the respiratory admittance: (i) the classical pole-zero interpolation proposed by Oustaloup in the early 90s, and (ii) the inverse discrete Fourier Transform (DFT). The results of the identified FO models for the respiratory admittance are presented by means of their average values for each group of patients. Consequently, the impulse time response calculated from the frequency response of the averaged FO models is given by means of the two methods mentioned above. Our results indicate that both methods provide similar impulse response data. However, we suggest that the inverse DFT is a more suitable alternative to the high order transfer functions obtained using the classical Oustaloup filter. Additionally, a power law model is fitted on the impulse response data, emphasizing the intrinsic fractal dynamics of the respiratory system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A intervenção humana no manuseamento de veículos submarinos operados remotamente (ROVs) é um requisito necessário para garantir o sucesso da missão e a integridade do equipamento. Contudo, a sua teleoperação não é fácil, pelo que a condução assistida destes veículos torna-se relevante. Esta dissertação propõe uma solução para este problema para ROVs de 3DOF (surge, heave e yaw). São propostas duas abordagens distintas – numa primeira propõe-se um sistema de controlo Image Based Visual Servoing (IBVS) tendo em vista a utilização exclusiva de uma câmara (sensor existente neste tipo de sistemas) por forma a melhorar significativamente a teleoperação de um pequeno ROV; na segunda, propõe-se um sistema de controlo cinemático para o plano horizontal do veículo e um algoritmo de uma manobra capaz de dotar o ROV de movimento lateral através de uma trajectória dente-de-serra. Demonstrou-se em cenários de operação real que o sistema proposto na primeira abordagem permite ao operador de um ROV com 3DOF executar tarefas de alguma complexidade (estabilização) apenas através de comandos de alto nível, melhorando assim drasticamente a teleoperação e qualidade de inspecção do veículo em questão. Foi também desenvolvido um simulador do ROV em MATLAB para validação e avaliação das manobras, onde o sistema proposto na segunda abordagem foi validado com sucesso.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper a complex-order van der Pol oscillator is considered. The complex derivative Dα±ȷβ , with α,β∈R + is a generalization of the concept of integer derivative, where α=1, β=0. By applying the concept of complex derivative, we obtain a high-dimensional parameter space. Amplitude and period values of the periodic solutions of the two versions of the complex-order van der Pol oscillator are studied for variation of these parameters. Fourier transforms of the periodic solutions of the two oscillators are also analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Si3N4 tools were coated with a thin diamond film using a Hot-Filament Chemical Vapour Deposition (HFCVD) reactor, in order to machining a grey cast iron. Wear behaviour of these tools in high speed machining was the main subject of this work. Turning tests were performed with a combination of cutting speeds of 500, 700 and 900 m min−1, and feed rates of 0.1, 0.25 and 0.4 mm rot−1, remaining constant the depth of cut of 1 mm. In order to evaluate the tool behaviour during the turning tests, cutting forces were analyzed being verified a significant increase with feed rate. Diamond film removal occurred for the most severe set of cutting parameters. It was also observed the adhesion of iron and manganese from the workpiece to the tool. Tests were performed on a CNC lathe provided with a 3-axis dynamometer. Results were collected and registered by homemade software. Tool wear analysis was achieved by a Scanning Electron Microscope (SEM) provided with an X-ray Energy Dispersive Spectroscopy (EDS) system. Surface analysis was performed by a profilometer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental and numerical investigation into the shear strength behaviour of adhesive single lap joints (SLJs) was carried out in order to understand the effect of temperature on the joint strength. The adherend material used for the experimental tests was an aluminium alloy in the form of thin sheets, and the adhesive used was a high-strength high temperature epoxy. Tensile tests as a function of temperature were performed and numerical predictions based on the use of a bilinear cohesive damage model were obtained. It is shown that at temperatures below Tg, the lap shear strength of SLJs increased, while at temperatures above Tg, a drastic drop in the lap shear strength was observed. Comparison between the experimental and numerical maximum loads representing the strength of the joints shows a reasonably good agreement.