8 resultados para HEAT BUDGET

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The operation of power systems in a Smart Grid (SG) context brings new opportunities to consumers as active players, in order to fully reach the SG advantages. In this context, concepts as smart homes or smart buildings are promising approaches to perform the optimization of the consumption, while reducing the electricity costs. This paper proposes an intelligent methodology to support the consumption optimization of an industrial consumer, which has a Combined Heat and Power (CHP) facility. A SCADA (Supervisory Control and Data Acquisition) system developed by the authors is used to support the implementation of the proposed methodology. An optimization algorithm implemented in the system in order to perform the determination of the optimal consumption and CHP levels in each instant, according to the Demand Response (DR) opportunities. The paper includes a case study with several scenarios of consumption and heat demand in the context of a DR event which specifies a maximum demand level for the consumer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A empresa Petibol, S.A. – Embalagens de plástico centra-se na produção de embalagens de plástico a partir da matéria-prima Poliestireno Expandido (EPS) e Polipropileno Expandido (EPP). A empresa possui uma preocupação ao nível da qualidade da água e do aproveitamento energético, tendo desta forma surgido a realização do estudo na unidade industrial, com o objectivo de anular e/ou diminuir as possíveis lacunas existentes na unidade industrial. Numa primeira etapa foi realizada uma caracterização global à qualidade da água e à empresa, actualizando-se os esquemas já existentes, contabilizando-se os custos actuais relativamente aos processos no circuito da água (arrefecimento, aquecimento e pressurização), e por fim, efectuou-se um levantamento in loco do circuito de água, relativamente à pressão, temperatura e caudal. Numa fase posterior, foram propostos equipamentos e processos, tendo em vista a colmatação dos problemas identificados, realizando-se um subsequente estudo relativamente aos custos inerentes a esses novos processos. A caracterização à água foi avaliada em diferentes pontos do circuito industrial, tendo-se determinado na Sala de Bombagem que o filtro de areia não possuía as dimensões mais apropriadas, existindo também um problema a nível mecânico associado ao processo de contra-lavagem. Tais factos podem ser a causa da ocorrência de um aumento do teor de sólidos após a passagem na camada filtrante. Relativamente ao amaciador, este deveria amaciar de forma completa a água para alimentação à caldeira, embora se tenha registado à saída do amaciador uma dureza de 21,3 mg/L, denunciando problemas na troca iónica. No que toca à água de alimentação à caldeira, verifica-se a existência de parâmetros que não se encontram de acordo com os critérios enunciados para uma óptima qualidade, sendo eles o pH (10,14), condutividade (363 μS/cm), teor de ferro (1,21 mg/L) e a dureza (16 mg/L). De salientar que somente o teor de cobre, que se encontra em quantidades vestigiais, apresenta-se de acordo com os valores impostos. No que respeita à água da caldeira, esta apresenta parâmetros incompatíveis com os recomendados, sendo eles a condutividade (7350 μS/cm), teor de sólidos dissolvidos (5248 mg/L) e alcalinidade total (780 mg/L). De referir que o valor de pH (11,8) não se encontra de acordo com a aplicação do tratamento “fosfato-pH coordenado”. Em relação aos parâmetros com valores que se encontram dentro dos limites, estes correspondem à dureza (0 mg/L), ao teor de fosfatos (45 mg/L) e teor de sílica (0 mg/L). A água do circuito de arrefecimento foi sujeita a uma análise microbiológica, que corroborou a presença de um biofilme. Um dos problemas enunciados pela empresa, prendia-se com a impossibilidade de descarga, no colector municipal, dos condensados dos compressores, visto apresentarem uma quantidade de óleo de cerca de 43,3 mg/L, equivalente a quatro vezes o valor limite de emissão, de acordo com a legislação municipal. Por fim, o efluente de descarga industrial apresenta um valor de pH (10,3) acima do intervalo permitido por lei (6,0 – 9,0), sendo que a corrente que mais contribui para este acréscimo de pH corresponde à corrente proveniente da água de purga, visto esta apresentar um valor de pH de 12,22. De maneira a contornar os parâmetros enunciados, é proposto a substituição do filtro de areia da Sala de Bombagem, assim como a inserção de um conjunto de medidas de remoção de ferro e desinfecção, sendo a conjugação de arejamento, coagulação, filtração e desinfecção, por parte do hipoclorito, a proposta apresentada. Aos condensados dos compressores é apresentado um sistema de separação, que possibilita a remoção do óleo da água, e uma consequente descarga da mesma. Actualmente, não existe qualquer filtro de areia no circuito de arrefecimento da água, sendo proposto assim esse equipamento, de forma a minorar o desenvolvimento da população microbiana, bem como a permitir uma maior eficiência na transferência de calor na torre de arrefecimento. Relativamente à descarga industrial, é recomendável a colocação de um sistema de regularização automática de pH. A inserção de uma válvula de três vias permite um aproveitamento energético e de água, a partir da confluência da água oriunda dos furos com a água do tanque de água fria, sendo posteriormente alimentada à central de vácuo. No estudo da recuperação energética, um outro equipamento avaliado correspondeu à serpentina, no entanto, verificou-se que a poupança no consumo de gás natural era de apenas 0,005%, o que não se mostrou uma proposta viável. O orçamento de todos os equipamentos é de 11.720,76 €, possibilitando não só um melhor funcionamento industrial, como um menor impacto a nível ambiental. Os custos futuros de funcionamento aumentam em 3,36%, tendo a pressurização um aumento do seu custo em 3,4% em relação ao custo actual, verificando-se um custo anual de 10.781,21€, em relação aos processos de arejamento, coagulação e desinfecção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to obtain, for Newtonian and non-Newtonian fluids, heat transfer coefficients, at constant wall temperature as boundary condition, in fully developed laminar flow inside a helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w) and the non-Newtonian fluids aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations 0.1%, 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations 0.1% and 0.2% (w/w). According to the rheological study performed, the polymer solutions had shear thinning behavior and different values of elasticity. The helical coil used has internal diameter, curvature ratio, length and pitch, respectively: 0.004575 m, 0.0263, 5.0 m and 11.34 mm. The Nusselt numbers for the CMC solutions are, on average, slightly higher than those for Newtonian fluids, for identical Prandtl and generalized Dean numbers. As outcome, the viscous component of the shear thinning polymer tends to potentiate the mixing effect of the Dean cells. The Nusselt numbers of the XG solutions are significant lower than those of the Newtonian solutions, for identical Prandtl and generalized Dean numbers. Therefore, the elastic component of the polymer tends to diminish the mixing effect of the Dean cells. A global correlation, for Nusselt number as a function of Péclet, generalized Dean and Weissenberg numbers for all Newtonian and non-Newtonian solutions studied, is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The differentiation of non-integer order has its origin in the seventeenth century, but only in the last two decades appeared the first applications in the area of control theory. In this paper we consider the study of a heat diffusion system based on the application of the fractional calculus concepts. In this perspective, several control methodologies are investigated namely the fractional PID and the Smith predictor. Extensive simulations are presented assessing the performance of the proposed fractional-order algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of differentiation and integration to non-integer order has its origins in the seventeen century. However, only in the second-half of the twenty century appeared the first applications related to the area of control theory. In this paper we consider the study of a heat diffusion system based on the application of the fractional calculus concepts. In this perspective, several control methodologies are investigated and compared. Simulations are presented assessing the performance of the proposed fractional-order algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to optimize the heat flow through the pultrusion die assembly system on the manufacturing process of a specific glass-fiber reinforced polymer (GFRP) pultrusion profile. The control of heat flow and its distribution through whole die assembly system is of vital importance in optimizing the actual GFRP pultrusion process. Through mathematical modeling of heating-die process, by means of Finite Element Analysis (FEA) program, an optimum heater selection, die position and temperature control was achieved. The thermal environment within the die was critically modeled relative not only to the applied heat sources, but also to the conductive and convective losses, as well as the thermal contribution arising from the exothermic reaction of resin matrix as it cures or polymerizes from the liquid to solid condition. Numerical simulation was validated with basis on thermographic measurements carried out on key points along the die during pultrusion process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pultrusion is an industrial process used to produce glass fibers reinforced polymers profiles. These materials are worldwide used when performing characteristics, such as great electrical and magnetic insulation, high strength to weight ratio, corrosion and weather resistance, long service life and minimal maintenance are required. In this study, we present the results of the modelling and simulation of heat flow through a pultrusion die by means of Finite Element Analysis (FEA). The numerical simulation was calibrated based on temperature profiles computed from thermographic measurements carried out during pultrusion manufacturing process. Obtained results have shown a maximum deviation of 7%, which is considered to be acceptable for this type of analysis, and is below to the 10% value, previously specified as maximum deviation. © 2011, Advanced Engineering Solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação realizada na empresa Continental-Indústria Têxtil do Ave, S.A., teve como objetivo a otimização energética da secção das malhas. Esta secção divide-se em duas áreas, a tricotagem e a ramulagem. Os artigos produzidos diferem no seu peso específico, composição e condições de operação, sendo os artigos A, B e C compostos por poliéster e termofixados a 190ºC e os artigos D e E compostos por poliéster e algodão, com uma temperatura de operação de 205ºC. Numa primeira etapa estudou-se o funcionamento da máquina de termofixação – a râmula – que opera em trabalho contínuo a 40 m/min. Esta máquina tem incorporado um permutador de calor, que aquece o ar fresco de entrada com os gases de exaustão das estufas. Posteriormente efetuou-se o levantamento energético de cada artigo, para as áreas de tricotagem e ramulagem. Verificou-se que os artigos D e E, pela sua constituição, são os que apresentam um consumo específico superior, em tep/ton. Entre as várias utilidades consumidas (gás natural, eletricidade e ar comprimido) o gás natural representa mais de 50% do consumo de energia total necessário para a produção de cada artigo. Após a completa análise aos consumos energéticos da râmula, foram realizados ensaios de otimização, tendo-se concluído que a diminuição do caudal de exaustão pode atingir valores de poupança anual de gás natural na ordem dos 3.000 €. Com o objetivo de avaliar o consumo de gás natural, não sendo possível a realização experimental, foram feitas simulações com base em alterações na corrente de entrada de ar fresco no permutador. Foi também estudada a possibilidade de isolamento e revestimento térmico da conduta exterior, projetada para o reaproveitamento do ar dos compressores, tendo-se obtido um orçamento de 2.500 €. Admitindo-se uma gama de temperaturas entre os 40ºC e os 60ºC, com um caudal de insuflação de 30%, obteve-se um payback entre os 0,97 e os 3,28 anos. Numa segunda fase admitiu-se uma temperatura média de 50ºC, aumentando o caudal de insuflação até 100%. O período de retorno obtido variou entre os 0,33 e os 1,38 anos, podendo as poupanças anuais atingirem os 7.600 €.