10 resultados para Fonction de partition
em Instituto Politécnico do Porto, Portugal
Resumo:
In order to overcome the problems associated with low water solubility, and consequently low bioavailability of active pharmaceutical ingredients (APIs), herein we explore a modular ionic liquid synthetic strategy for improved APIs. Ionic liquids containing l-ampicillin as active pharmaceutical ingredient anion were prepared using the methodology developed in our previous work, using organic cations selected from substituted ammonium, phosphonium, pyridinium and methylimidazolium salts, with the intent of enhancing the solubility and bioavailability of l-ampicillin forms. In order to evaluate important properties of the synthesized API-ILs, the water solubility at 25 °C and 37 °C (body temperature) as well as octanol–water partition coefficients (Kow's) and HDPC micelles partition at 25 °C were measured. Critical micelle concentrations (CMC's) in water at 25 °C and 37 °C of the pharmaceutical ionic liquids bearing cations with surfactant properties were also determined from ionic conductivity measurements.
Resumo:
With the electricity market liberalization, the distribution and retail companies are looking for better market strategies based on adequate information upon the consumption patterns of its electricity consumers. A fair insight on the consumers’ behavior will permit the definition of specific contract aspects based on the different consumption patterns. In order to form the different consumers’ classes, and find a set of representative consumption patterns we use electricity consumption data from a utility client’s database and two approaches: Two-step clustering algorithm and the WEACS approach based on evidence accumulation (EAC) for combining partitions in a clustering ensemble. While EAC uses a voting mechanism to produce a co-association matrix based on the pairwise associations obtained from N partitions and where each partition has equal weight in the combination process, the WEACS approach uses subsampling and weights differently the partitions. As a complementary step to the WEACS approach, we combine the partitions obtained in the WEACS approach with the ALL clustering ensemble construction method and we use the Ward Link algorithm to obtain the final data partition. The characterization of the obtained consumers’ clusters was performed using the C5.0 classification algorithm. Experiment results showed that the WEACS approach leads to better results than many other clustering approaches.
Resumo:
The present research paper presents five different clustering methods to identify typical load profiles of medium voltage (MV) electricity consumers. These methods are intended to be used in a smart grid environment to extract useful knowledge about customer’s behaviour. The obtained knowledge can be used to support a decision tool, not only for utilities but also for consumers. Load profiles can be used by the utilities to identify the aspects that cause system load peaks and enable the development of specific contracts with their customers. The framework presented throughout the paper consists in several steps, namely the pre-processing data phase, clustering algorithms application and the evaluation of the quality of the partition, which is supported by cluster validity indices. The process ends with the analysis of the discovered knowledge. To validate the proposed framework, a case study with a real database of 208 MV consumers is used.
Resumo:
A methodology based on data mining techniques to support the analysis of zonal prices in real transmission networks is proposed in this paper. The mentioned methodology uses clustering algorithms to group the buses in typical classes that include a set of buses with similar LMP values. Two different clustering algorithms have been used to determine the LMP clusters: the two-step and K-means algorithms. In order to evaluate the quality of the partition as well as the best performance algorithm adequacy measurements indices are used. The paper includes a case study using a Locational Marginal Prices (LMP) data base from the California ISO (CAISO) in order to identify zonal prices.
Resumo:
ARINC specification 653-2 describes the interface between application software and underlying middleware in a distributed real-time avionics system. The real-time workload in this system comprises of partitions, where each partition consists of one or more processes. Processes incur blocking and preemption overheads and can communicate with other processes in the system. In this work we develop compositional techniques for automated scheduling of such partitions and processes. At present, system designers manually schedule partitions based on interactions they have with the partition vendors. This approach is not only time consuming, but can also result in under utilization of resources. In contrast, the technique proposed in this paper is a principled approach for scheduling ARINC-653 partitions and therefore should facilitate system integration.
Resumo:
This paper consists in the characterization of medium voltage (MV) electric power consumers based on a data clustering approach. It is intended to identify typical load profiles by selecting the best partition of a power consumption database among a pool of data partitions produced by several clustering algorithms. The best partition is selected using several cluster validity indices. These methods are intended to be used in a smart grid environment to extract useful knowledge about customers’ behavior. The data-mining-based methodology presented throughout the paper consists in several steps, namely the pre-processing data phase, clustering algorithms application and the evaluation of the quality of the partitions. To validate our approach, a case study with a real database of 1.022 MV consumers was used.
Resumo:
This paper presents an electricity medium voltage (MV) customer characterization framework supportedby knowledge discovery in database (KDD). The main idea is to identify typical load profiles (TLP) of MVconsumers and to develop a rule set for the automatic classification of new consumers. To achieve ourgoal a methodology is proposed consisting of several steps: data pre-processing; application of severalclustering algorithms to segment the daily load profiles; selection of the best partition, corresponding tothe best consumers’ segmentation, based on the assessments of several clustering validity indices; andfinally, a classification model is built based on the resulting clusters. To validate the proposed framework,a case study which includes a real database of MV consumers is performed.
Resumo:
This paper presents the characterization of high voltage (HV) electric power consumers based on a data clustering approach. The typical load profiles (TLP) are obtained selecting the best partition of a power consumption database among a pool of data partitions produced by several clustering algorithms. The choice of the best partition is supported using several cluster validity indices. The proposed data-mining (DM) based methodology, that includes all steps presented in the process of knowledge discovery in databases (KDD), presents an automatic data treatment application in order to preprocess the initial database in an automatic way, allowing time saving and better accuracy during this phase. These methods are intended to be used in a smart grid environment to extract useful knowledge about customers’ consumption behavior. To validate our approach, a case study with a real database of 185 HV consumers was used.
Resumo:
Sorption is commonly agreed to be the major process underlying the transport and fate of polycyclic aromatic hydrocarbons (PAHs) in soils. However, there is still a scarcity of studies focusing on spatial variability at the field scale in particular. In order to investigate the variation in the field of phenanthrene sorption, bulk topsoil samples were taken in a 15 × 15-m grid from the plough layer in two sandy loam fields with different texture and organic carbon (OC) contents (140 samples in total). Batch experiments were performed using the adsorption method. Values for the partition coefficient K d (L kg−1) and the organic carbon partition coefficient K OC (L kg−1) agreed with the most frequently used models for PAH partitioning, as OC revealed a higher affinity for sorption. More complex models using different OC compartments, such as non-complexed organic carbon (NCOC) and complexed organic carbon (COC) separately, performed better than single K OC models, particularly for a subset including samples with Dexter n < 10 and OC <0.04 kg kg−1. The selected threshold revealed that K OC-based models proved to be applicable for more organic fields, while two-component models proved to be more accurate for the prediction of K d and retardation factor (R) for less organic soils. Moreover, OC did not fully reflect the changes in phenanthrene retardation in the field with lower OC content (Faardrup). Bulk density and available water content influenced the phenanthrene transport mechanism phenomenon.
Resumo:
A presente tese pretende fazer uma abordagem ao crescimento dos consumos de energia elétrica, que se tem verificado, nos últimos anos, no setor das telecomunicações e das tecnologias de informação; devido ao constante crescimento das redes, dos equipamentos a ela ligados e do tráfego que nelas transita. Num contexto de globalização da economia, no qual, as redes de telecomunicações e de energia elétrica são dois dos maiores contribuintes, a presente tese procura encontrar enquadramentos e soluções para um dos maiores desafios que a humanidade enfrenta atualmente, e que em parte, é consequente dessa globalização: encontrar novas fontes e formas de utilização da energia, -particularmente da energia elétrica - para que a humanidade continue a usufruir, de uma forma sustentável, dos benefícios que a mesma proporciona. Na primeira parte, procura-se fazer uma abordagem que utiliza fontes de informação e conhecimento, do mercado global, nomeadamente, entidades reguladoras e normalizadoras, operadores, fornecedores de tecnologias e consumidores, que abrangessem os três maiores mercados mundiais – União Europeia, Estados Unidos da América e Ásia-Pacífico. Considerou-se fundamental fazê-lo, por se tratar de uma dissertação no âmbito de um Mestrado com o selo de garantia EUR-ACE. Ao longo da dissertação analisou-se a temática da eficiência energética nas redes de telecomunicações e das tecnologias de informação e comunicação, um tema cada vez mais pertinente, já que o número de pessoas com ligações à Internet, já supera os 3 mil milhões, e as redes passaram a ser o meio por onde são transmitidos, a cada segundo, terabytes de sinais de voz, dados e vídeo. Procurou-se encontrar as linhas de orientação que estão a ser traçadas, para otimizar os consumos energéticos, de um complexo sistema convergente de redes e serviços, formado por entidades reguladoras e normalizadoras, operadores, fornecedores de tecnologias e consumidores, onde nem sempre as fronteiras estão perfeitamente definidas. Perante a constatação da realidade exposta, analisou-se as políticas energéticas desenvolvidas nos últimos anos, pelos vários players do mercado das telecomunicações, das tecnologias de informação e dos sistemas elétricos de energia bem como algumas métricas e objetivos comumente aceites. viii São analisados os contributos das partes interessadas, para o desenvolvimento de políticas energéticas eficazes, por forma a permitirem uma implementação, que considere o funcionamento dos equipamentos como um todo, e não de uma forma isolada como tradicionalmente o assunto era abordado. As especificidades na forma como funcionam as redes de telecomunicações e respetivos equipamentos, são expostas sobre várias óticas, comprovando-se que a temática da eficiência energética é uma das áreas mais difíceis lidar, de todas as consideradas nas políticas energéticas. Demonstrou-se que muitos dos equipamentos não estão otimizados em termos de gestão de energia, procurou-se evidenciar as consequências dessa realidade, uma vez que os equipamentos referidos, têm a necessidade de estar permanentemente a ser alimentados pela rede de energia elétrica, para garantir as funções para que foram projetados. Da pesquisa efetuada e descrita ao longo da dissertação, constatamos o empenho de toda a comunidade científica, operadores e agências de energia e de telecomunicações, em resolver o problema, já que há a consciencialização de que o ritmo de crescimento da rede e equipamentos terminais, é superior ao registado na melhoria da eficiência energética dos vários componentes e equipamentos terminais. Na segunda parte do relatório da tese, procurou-se testar a aplicabilidade das normas e recomendações dos organismos que tutelam a atividade a nível global - algumas publicadas nos últimos 2 anos - a um caso prático. Um edifício hospitalar de média dimensão. Foi elaborada uma aplicação informática, que suportada numa metodologia padronizada, seja capaz de fazer a avaliação da eficiência energética dos equipamentos serviços de telecomunicações de informação e comunicação em funcionamento do hospital. Por dificuldades de disponibilidade dos responsáveis do edifício, os resultados ficaram aquém do esperado. Conseguiu-se desenhar a aplicação, inventariar-se apenas parte dos equipamentos. Demonstrou-se que, a forma como alguns equipamentos estão a ser utilizados, não cumprem regras de utilização racional e eficiente. Procurou-se sensibilizar alguns dos responsáveis, para a necessidade de alterar comportamentos e prosseguir o processo de inventariação, por forma, a que o trabalho iniciado atinja os objetivos propostos.