4 resultados para Flames Premixed Laminar

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to determine, for Newtonian and non-Newtonian fluids, the friction factor (fc) with simultaneous heat transfer, at constant wall temperature as boundary condition, in fully developed laminar flow inside a vertical helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w). The non-Newtonian fluids were aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations of 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations of 0.1% and 0.2% (w/w). According to the rheological study done, the polymer solutions had shear-thinning behavior and different values of viscoelasticity. The helical coil used has an internal diameter, curvature ratio, length and pitch, respectively: 0.00483 m, 0.0263, 5.0 m and 11.34 mm. It was concluded that the friction factors, with simultaneous heat transfer, for Newtonian fluids can be calculated using expressions from literature for isothermal flows. The friction factors for CMC and XG solutions are similar to those for Newtonian fluids when the Dean number, based in a generalized Reynolds number, is less than 80. For Dean numbers higher than 80, the friction factors of the CMC solutions are lower those of the XG solutions and of the Newtonian fluids. In this range the friction factors decrease with the increase of the viscometric component of the solution and increase for increasing elastic component. The change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, is in accordance with the study of Ali [4]. There is a change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, which is in according to previous studies. The data also showed that the use of the bulk temperature or of the film temperature to calculate the physical properties of the fluid has a residual effect in the friction factor values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to obtain, for Newtonian and non-Newtonian fluids, heat transfer coefficients, at constant wall temperature as boundary condition, in fully developed laminar flow inside a helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w) and the non-Newtonian fluids aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations 0.1%, 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations 0.1% and 0.2% (w/w). According to the rheological study performed, the polymer solutions had shear thinning behavior and different values of elasticity. The helical coil used has internal diameter, curvature ratio, length and pitch, respectively: 0.004575 m, 0.0263, 5.0 m and 11.34 mm. The Nusselt numbers for the CMC solutions are, on average, slightly higher than those for Newtonian fluids, for identical Prandtl and generalized Dean numbers. As outcome, the viscous component of the shear thinning polymer tends to potentiate the mixing effect of the Dean cells. The Nusselt numbers of the XG solutions are significant lower than those of the Newtonian solutions, for identical Prandtl and generalized Dean numbers. Therefore, the elastic component of the polymer tends to diminish the mixing effect of the Dean cells. A global correlation, for Nusselt number as a function of Péclet, generalized Dean and Weissenberg numbers for all Newtonian and non-Newtonian solutions studied, is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No trabalho realizado nesta tese, procedeu-se ao estudo hidrodinâmico de uma coluna de borbulhamento de recirculação externa do líquido (CREL), que permitiu ampliar o conhecimento já existente sobre este tipo de colunas. Para realizar este estudo utilizaram-se líquidos viscosos Newtonianos, nomeadamente soluções aquosas de glicerina com viscosidades entre 0,007 e 0,522 Pa.s. Para a gama de caudais de ar injectados, 1,5x10-5 até 1,35x10-4 m3/s, o ar ascendia ao longo da coluna de borbulhamento sob a forma de bolhas tubulares. Após a realização dos ensaios, verificou-se que o regime de escoamento do líquido entre bolhas tubulares variou desde o tipo laminar até transição (1,9 laminar até ao regime turbulento (12,1 < ReV <3297). Nos ensaios experimentais foram utilizadas duas colunas de borbulhamento com diferentes diâmetros internos de 22 e 32 mm. A razão de submersão, , seleccionada foi de 0,85. Este valor foi escolhido por ser significativamente diferente dos usados em estudos anteriores (0,935 por Santos (2004), Santos (2005) e 0,91 por Rangel (2008)) de forma a poder analisar a influência da razão de submersão sobre os parâmetros hidrodinâmicos. Nos ensaios realizados foram determinadas a retenção do gás na coluna e a velocidade superficial do líquido em escoamento no interior da coluna de borbulhamento. Os valores da retenção do gás foram comparados com valores teóricos previstos por equações empíricas de Nicklin et al (1962). Estes valores também foram comparados com valores obtidos experimentalmente em trabalhos anteriores, onde se utilizaram razões de submersão de 0,935 e 0,91. Após análise dos valores da retenção verificou-se que estes eram mais elevados para as soluções de maior viscosidade e menor diâmetro da coluna. Para as experiências realizadas com as soluções com viscosidades entre 0,52 Pa.s e 0,053 Pa.s, os valores experimentais eram inferiores aos previstos por Nicklin et al (1962) para regime laminar tanto na coluna de 22 mm como na coluna de 32 mm. Para a solução com 0,007 Pa.s de viscosidade os valores experimentais situavam-se na zona de transição entre o regime laminar e o regime turbulento em ambas as colunas. Verificou-se que a diminuição da razão de submersão de 0,935 para 0,85 aumentou significativamente a retenção em todas as experiências realizadas. A velocidade superficial média de circulação do líquido variava na razão inversa do diâmetro e da viscosidade. A diminuição da retenção provocou uma diminuição significativa na velocidade do líquido.