9 resultados para Fatigue Crack Nucleation

em Instituto Politécnico do Porto, Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work tubular fiber reinforced specimens are tested for fatigue life. The specimens are biaxially loaded with tension and shear stresses, with a load angle β of 30° and 60° and a load ratio of R=0,1. There are many factors that affect fatigue life of a fiber reinforced material and the main goal of this work is to study the effects of load ratio R by obtaining S-N curves and compare them to the previous works (1). All the other parameters, such as specimen production, fatigue loading frequency and temperature, will be the same as for the previous tests. For every specimen, stiffness, temperature of the specimen during testing, crack counting and final fracture mode are obtained. Prior to testing, a study if the literature regarding the load ratio effects on composites fatigue life and with that review estimate the initial stresses to be applied in testing. In previous works (1) similar specimens have only been tested for a load ratio of R=-1 and therefore the behaviour of this tubular specimens for a different load ratio is unknown. All the data acquired will be analysed and compared to the previous works, emphasizing the differences found and discussing the possible explanations for those differences. The crack counting software, developed at the institute, has shown useful before, however different adjustments to the software parameters lead to different cracks numbers for the same picture, and therefore a better methodology will be discussed to improve the crack counting results. After the specimen’s failure, all the data will be collected and stored and fibre volume content for every specimen is also determinate. The number of tests required to make the S-N curves are obtained according to the existent standards. Additionally are also identified some improvements to the testing machine setup and to the procedures for future testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the influence of position and pauses on muscle activity and fatigue during the task of ironing. Ten female participants performed the task of ironing in two different positions (standing and sitting) for 10 min each with a 1-min pause at the end of each task. Muscle activity and fatigue from the upper trapezium, anterior deltoid, and pectoralis major were analyzed using surface electromyography. The results showed that the positions had no significant influence on muscle activity; nevertheless, they had significant influence on muscular fatigue. In addition, the pauses were possibly beneficial in decreasing the muscle fatigue, but the results were not conclusive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesive bonding as a joining or repair method has a wide application in many industries. Repairs with bonded patches are often carried out to re-establish the stiffness at critical regions or spots of corrosion and/or fatigue cracks. Single and double-strap repairs (SS and DS, respectively) are a viable option for repairing. For the SS repairs, a patch is adhesively-bonded on one of the structure faces. SS repairs are easy to execute, but the load eccentricity leads to peel peak stresses at the overlap edges. DS repairs involve the use of two patches, one on each face of the structure. These are more efficient than SS repairs, due to the doubling of the bonding area and suppression of the transverse deflection of the adherends. Shear stresses also become more uniform as a result of smaller differential straining. The experimental and Finite Element (FE) study presented here for strength prediction and design optimization of bonded repairs includes SS and DS solutions with different values of overlap length (LO). The examined values of LO include 10, 20 and 30 mm. The failure strengths of the SS and DS repairs were compared with FE results by using the Abaqus® FE software. A Cohesive Zone Model (CZM) with a triangular shape in pure tensile and shear modes, including the mixed-mode possibility for crack growth, was used to simulate fracture of the adhesive layer. A good agreement was found between the experiments and the FE simulations on the failure modes, elastic stiffness and strength of the repairs, showing the effectiveness and applicability of the proposed FE technique in predicting strength of bonded repairs. Furthermore, some optimization principles were proposed to repair structures with adhesively-bonded patches that will allow repair designers to effectively design bonded repairs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mode III interlaminar fracture of carbon/epoxy laminates was evaluated with the edge crack torsion (ECT) test. Three-dimensional finite element analyses were performed in order to select two specimen geometries and an experimental data reduction scheme. Test results showed considerable non-linearity before the maximum load point and a significant R-curve effect. These features prevented an accurate definition of the initiation point. Nevertheless, analyses of non-linearity zones showed two likely initiation points corresponding to GIIIc values between 850 and 1100 J/m2 for both specimen geometries. Although any of these values is realistic, the range is too broad, thus showing the limitations of the ECT test and the need for further research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ergonomic interventions such as increased scheduled breaks or job rotation have been proposed to reduce upper limb muscle fatigue in repetitive low-load work. This review was performed to summarize and analyze the studies investigating the effect of job rotation and work-rest schemes, as well as, work pace, cycle time and duty cycle, on upper limb muscle fatigue. The effects of these work organization factors on subjective fatigue or discomfort were also analyzed. This review was based on relevant articles published in PubMed, Scopus and Web of Science. The studies included in this review were performed in humans and assessed muscle fatigue in upper limbs. 14 articles were included in the systematic review. Few studies were performed in a real work environment and the most common methods used to assess muscle fatigue were surface electromyography (EMG). No consistent results were found related to the effects of job rotation on muscle activity and subjective measurements of fatigue. Rest breaks had some positive effects, particularly in perceived discomfort. The increase in work pace reveals a higher muscular load in specific muscles. The duration of experiments and characteristics of participants appear to be the factors that most have influenced the results. Future research should be focused on the improvement of the experimental protocols and instrumentation, in order to the outcomes represent adequately the actual working conditions. Relevance to industry: Introducing more physical workload variation in low-load repetitive work is considered an effective ergonomic intervention against muscle fatigue and musculoskeletal disorders in industry. Results will be useful to identify the need of future research, which will eventually lead to the adoption of best industrial work practices according to the workers capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the influence of position and pauses on muscle activity and fatigue during the task of ironing. Ten female participants performed the task of ironing in two different positions (standing and sitting) for 10 min each with a 1-min pause at the end of each task. Muscle activity and fatigue from the upper trapezium, anterior deltoid, and pectoralis major were analyzed using surface electromyography. The results showed that the positions had no significant influence on muscle activity; nevertheless, they had significant influence on muscular fatigue. In addition, the pauses were possibly beneficial in decreasing the muscle fatigue, but the results were not conclusive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A utilização de juntas adesivas em aplicações industriais tem vindo a aumentar, em detrimento dos métodos tradicionais tais como a soldadura, brasagem e ligações aparafusadas e rebitadas. Este facto deve-se às vantagens que estas oferecem, como o facto de serem mais leves, comportarem-se bem sob cargas cíclicas ou de fadiga, a ligação de materiais diferentes e menores concentrações de tensões. Para aumentar a confiança no projeto de estruturas adesivas, é importante conseguir prever com precisão a sua resistência mecânica e respetivas propriedades de fratura (taxa crítica de libertação de energia de deformação à tração, GIC, e corte, GIIC). Estas propriedades estão diretamente relacionadas com a Mecânica da Fratura e são estimadas através de uma análise energética. Para este efeito, distinguem-se três tipos de modelos: modelos que necessitam da medição do comprimento de fenda durante a propagação do dano, modelos que utilizam um comprimento de fenda equivalente e métodos baseados no integral J. Como na maioria dos casos as solicitações ocorrem em modo misto (combinação de tração com corte), é de grande importância a perceção da fratura nesta condições, nomeadamente das taxas de libertação de energia relativamente a diferentes critérios ou envelopes de fratura. Esta comparação permite, por exemplo, averiguar qual o melhor critério energético de rotura a utilizar em modelos numéricos baseados em Modelos de Dano Coesivo. Neste trabalho é realizado um estudo experimental utilizando o ensaio Single-Leg Bending (SLB) em provetes colados com três tipos de adesivos, de forma a estudar e comparar as suas propriedades de fratura. Para tal, são aplicados alguns modelos de redução da taxa de libertação de energia de deformação à tração, GI, e corte, GII, enquadrados nos modelos que necessitam da medição do comprimento de fenda e nos modelos que utilizam um comprimento de fenda equivalente. Numa fase posterior, procedeu-se à análise e comparação dos resultados adquiridos durante a fase experimental de GI e GII de cada adesivo. A discussão de resultados foi também feita através da análise dos valores obtidos em diversos envelopes de fratura, no sentido de averiguar qual o critério de rotura mais adequado a considerar para cada adesivo. Foi obtida uma concordância bastante boa entre métodos de determinação de GI e GII, com exceção do adesivo mais dúctil, para o qual o método baseado no comprimento de fenda equivalente apresentou resultados ligeiramente superiores.