48 resultados para Energy-Efficiency
em Instituto Politécnico do Porto, Portugal
Resumo:
In this abstract is presented an energy management system included in a SCADA system existent in a intelligent home. The system control the home energy resources according to the players definitions (electricity consumption and comfort levels), the electricity prices variation in real time mode and the DR events proposed by the aggregators.
Resumo:
The implementation of smart homes allows the domestic consumer to be an active player in the context of the Smart Grid (SG). This paper presents an intelligent house management system that is being developed by the authors to manage, in real time, the power consumption, the micro generation system, the charge and discharge of the electric or plug-in hybrid vehicles, and the participation in Demand Response (DR) programs. The paper proposes a method for the energy efficiency analysis of a domestic consumer using the SCADA House Intelligent Management (SHIM) system. The main goal of the present paper is to demonstrate the economic benefits of the implemented method. The case study considers the consumption data of some real cases of Portuguese house consumption over 30 days of June of 2012, the Portuguese real energy price, the implementation of the power limits at different times of the day and the economic benefits analysis.
Resumo:
Gradually smart grids and smart meters are closer to the home consumers. Several countries has developed studies focused in the impacts arising from the introduction of these technologies and one of the main advantages are related to energy efficiency, observed through the awareness of the population on behalf of a more efficient consumption. These benefits are felt directly by consumers through the savings on electricity bills and also by the concessionaires through the minimization of losses in transmission and distribution, system stability, smaller loading during peak hours, among others. In this article two projects that demonstrate the potential energy savings through smart meters and smart grids are presented. The first performed in Korea, focusing on the installation of smart meters and the impact of use of user interfaces. The second performed in Portugal, focusing on the control of loads in a residence with distributed generation.
Resumo:
Cluster scheduling and collision avoidance are crucial issues in large-scale cluster-tree Wireless Sensor Networks (WSNs). The paper presents a methodology that provides a Time Division Cluster Scheduling (TDCS) mechanism based on the cyclic extension of RCPS/TC (Resource Constrained Project Scheduling with Temporal Constraints) problem for a cluster-tree WSN, assuming bounded communication errors. The objective is to meet all end-to-end deadlines of a predefined set of time-bounded data flows while minimizing the energy consumption of the nodes by setting the TDCS period as long as possible. Sinceeach cluster is active only once during the period, the end-to-end delay of a given flow may span over several periods when there are the flows with opposite direction. The scheduling tool enables system designers to efficiently configure all required parameters of the IEEE 802.15.4/ZigBee beaconenabled cluster-tree WSNs in the network design time. The performance evaluation of thescheduling tool shows that the problems with dozens of nodes can be solved while using optimal solvers.
Resumo:
Consolidation consists in scheduling multiple virtual machines onto fewer servers in order to improve resource utilization and to reduce operational costs due to power consumption. However, virtualization technologies do not offer performance isolation, causing applications’ slowdown. In this work, we propose a performance enforcing mechanism, composed of a slowdown estimator, and a interference- and power-aware scheduling algorithm. The slowdown estimator determines, based on noisy slowdown data samples obtained from state-of-the-art slowdown meters, if tasks will complete within their deadlines, invoking the scheduling algorithm if needed. When invoked, the scheduling algorithm builds performance and power aware virtual clusters to successfully execute the tasks. We conduct simulations injecting synthetic jobs which characteristics follow the last version of the Google Cloud tracelogs. The results indicate that our strategy can be efficiently integrated with state-of-the-art slowdown meters to fulfil contracted SLAs in real-world environments, while reducing operational costs in about 12%.
Resumo:
This paper presents the system developed to promote the rational use of electric energy among consumers and, thus, increase the energy efficiency. The goal is to provide energy consumers with an application that displays the energy consumption/production profiles, sets up consuming ceilings, defines automatic alerts and alarms, compares anonymously consumers with identical energy usage profiles by region and predicts, in the case of non-residential installations, the expected consumption/production values. The resulting distributed system is organized in two main blocks: front-end and back-end. The front-end includes user interface applications for Android mobile devices and Web browsers. The back-end provides data storage and processing functionalities and is installed in a cloud computing platform - the Google App Engine - which provides a standard Web service interface. This option ensures interoperability, scalability and robustness to the system.
Resumo:
PM motors are suitable for nearly all applications, like pumps, elevators, compressors, blowers, extruders, generators, electric vehicles, servodrives, cooling towers, household appliances, etc. This paper will present some applications where the use of PM motors allowed for enhancements in energy efficiency and process quality.
Resumo:
Indoor Air 2016 - The 14th International Conference of Indoor Air Quality and Climate
Resumo:
Uma linha de pesquisa e desenvolvimento na área da robótica, que tem recebido atenção crescente nos últimos anos, é o desenvolvimento de robôs biologicamente inspirados. A ideia é adquirir conhecimento de seres biológicos, cuja evolução ocorreu ao longo de milhões de anos, e aproveitar o conhecimento assim adquirido para implementar a locomoção pelos mesmos métodos (ou pelo menos usar a inspiração biológica) nas máquinas que se constroem. Acredita-se que desta forma é possível desenvolver máquinas com capacidades semelhantes às dos seres biológicos em termos de capacidade e eficiência energética de locomoção. Uma forma de compreender melhor o funcionamento destes sistemas, sem a necessidade de desenvolver protótipos dispendiosos e com longos tempos de desenvolvimento é usar modelos de simulação. Com base nestas ideias, o objectivo deste trabalho passa por efectuar um estudo da biomecânica da santola (Maja brachydactyla), uma espécie de caranguejo comestível pertencente à família Majidae de artrópodes decápodes, usando a biblioteca de ferramentas SimMechanics da aplicação Matlab / Simulink. Esta tese descreve a anatomia e locomoção da santola, a sua modelação biomecânica e a simulação do seu movimento no ambiente Matlab / SimMechanics e SolidWorks.
Resumo:
Radio interference drastically affects the performance of sensor-net communications, leading to packet loss and reduced energy-efficiency. As an increasing number of wireless devices operates on the same ISM frequencies, there is a strong need for understanding and debugging the performance of existing sensornet protocols under interference. Doing so requires a low-cost flexible testbed infrastructure that allows the repeatable generation of a wide range of interference patterns. Unfortunately, to date, existing sensornet testbeds lack such capabilities, and do not permit to study easily the coexistence problems between devices sharing the same frequencies. This paper addresses the current lack of such an infrastructure by using off-the-shelf sensor motes to record and playback interference patterns as well as to generate customizable and repeat-able interference in real-time. We propose and develop JamLab: a low-cost infrastructure to augment existing sensornet testbeds with accurate interference generation while limiting the overhead to a simple upload of the appropriate software. We explain how we tackle the hardware limitations and get an accurate measurement and regeneration of interference, and we experimentally evaluate the accuracy of JamLab with respect to time, space, and intensity. We further use JamLab to characterize the impact of interference on sensornet MAC protocols.
Resumo:
Wireless sensor networks (WSNs) emerge as underlying infrastructures for new classes of large-scale networked embedded systems. However, WSNs system designers must fulfill the quality-of-service (QoS) requirements imposed by the applications (and users). Very harsh and dynamic physical environments and extremely limited energy/computing/memory/communication node resources are major obstacles for satisfying QoS metrics such as reliability, timeliness, and system lifetime. The limited communication range of WSN nodes, link asymmetry, and the characteristics of the physical environment lead to a major source of QoS degradation in WSNs-the ldquohidden node problem.rdquo In wireless contention-based medium access control (MAC) protocols, when two nodes that are not visible to each other transmit to a third node that is visible to the former, there will be a collision-called hidden-node or blind collision. This problem greatly impacts network throughput, energy-efficiency and message transfer delays, and the problem dramatically increases with the number of nodes. This paper proposes H-NAMe, a very simple yet extremely efficient hidden-node avoidance mechanism for WSNs. H-NAMe relies on a grouping strategy that splits each cluster of a WSN into disjoint groups of non-hidden nodes that scales to multiple clusters via a cluster grouping strategy that guarantees no interference between overlapping clusters. Importantly, H-NAMe is instantiated in IEEE 802.15.4/ZigBee, which currently are the most widespread communication technologies for WSNs, with only minor add-ons and ensuring backward compatibility with their protocols standards. H-NAMe was implemented and exhaustively tested using an experimental test-bed based on ldquooff-the-shelfrdquo technology, showing that it increases network throughput and transmission success probability up to twice the values obtained without H-NAMe. H-NAMe effectiveness was also demonstrated in a target tracking application with mobile robots - over a WSN deployment.
Resumo:
Para qualquer empresa o seu maior objetivo passa pela produção de lucro e, atualmente, esse aspeto está diretamente relacionado com a sua capacidade de manter uma gestão que incorpore a responsabilidade social, ambiental e económica, em prol de um desenvolvimento global mais sustentável. As grandes empresas já iniciaram e continuam este processo de mudança, desenvolvendo medidas e estratégias neste sentido. Porém, apesar de representarem o grosso do tecido empresarial, as Pequenas e Médias Empresas só agora começam a dar os primeiros passos em direção a uma gestão mais ponderada ambiental e energeticamente. Com este trabalho pretende-se reunir informação relativa às Pequenas e Médias Empresas portuguesas de forma a compreender quais as principais áreas de atuação, as medidas que poderão ser implementadas e, consolidar o ponto de situação deste sector acerca dos vários temas ao nível do meio ambiente e da energia. Para tal, foram realizados levantamentos energéticos e aplicado um questionário acerca dos comportamentos e práticas ambientais. Verificou-se que apesar da grande maioria das empresas analisadas já terem ponderado a importância e as vantagens da eficiência energética, ainda são poucas as organizações que têm implementados planos, estratégias ou instrumentos para melhoria do seu desempenho ambiental e energético.
Resumo:
Nesta dissertação pretende-se caracterizar o desempenho energético de um grande edifício de serviços existente, da tipologia ensino, avaliar e identificar potenciais medidas que melhorem aquele desempenho, permitindo, em complemento, determinar a sua classificação energética no âmbito da legislação vigente. A pertinência do estudo prende-se com a avaliação do desempenho energético dos edifícios e com o estudo de medidas de melhoria que permitam incrementar a eficiência energética, por recurso a um programa de simulação energética dinâmica certificado – DesignBuilder e tendo em conta a regulamentação portuguesa em vigor. Inicialmente procedeu-se à modelação do edifício com recurso ao programa DesignBuilder, e, simultaneamente, realizou-se um levantamento de todas as suas características ao nível de geometria, pormenores construtivos, sistemas AVAC e de iluminação e fontes de energia utilizadas. Com vista à caracterização do modo de operação do edifício, foi realizado um levantamento dos perfis reais de utilização em termos de ocupação, iluminação e equipamentos para os vários espaços. Foram realizadas medições de caudais de ar novo e da temperatura do ar, em alguns equipamentos e alguns espaços específicos. Foram realizadas medições em tempo real e leituras de contagens da energia eléctrica utilizada, quer em período de aulas quer em período de férias, que permitiram a desagregação das facturas da energia eléctrica que se apresentam globais para o campus do ISEP. Foram realizadas leituras de contagens de gás natural. Em sequência, foi realizada a simulação energética dinâmica com o intuito de ajustar o modelo criado aos consumos reais e de analisar medidas de melhoria que lhe conferissem um melhor desempenho energético. Essas medidas são agrupadas em quatro tipos: - Medidas de natureza comportamental; - Medidas de melhoria da eficiência energética nos sistemas de iluminação; - Medidas de melhoria de eficiência energética nos sistemas AVAC;- Medidas que visam a introdução de energias de fonte renovável; Em sequência, foi elaborada a simulação nominal e calculados os indicadores de eficiência energética com vista à respectiva classificação energética do edifício, tendo o edifício apresentado uma Classe Energética D de acordo com a escala do SCE. Finalmente, foi avaliado o impacto das diferentes medidas de melhoria identificadas e com potencial de aplicação, isto é, que apresentaram um retorno simples do investimento inferior a oito anos, tanto ao nível do desempenho energético real do edifício, como ao nível da sua classificação energética. De onde se concluiu que existe um potencial de 7% de redução nos consumos energéticos actuais do edifício e de 18% se o funcionamento do edifício for em pleno, ou seja, se todos os seus sistemas estiverem efectivamente em funcionamento, e que terá impacto na classificação energética alcançado uma Classe Energética C.
Resumo:
A forte preocupação ambiental, nomeadamente a emissão de Gases com Efeito de Estufa (GEE), aliada à constante ameaça do esgotamento dos combustíveis de origem fóssil, leva à necessidade de consumir energia de forma mais eficiente. Neste sentido, surge a promoção da eficiência energética nos diversos sectores consumidores de energia em todo o Mundo. Sabendo que passamos mais de 80% do nosso tempo dentro de edifícios, e que cerca de 40% da energia mundial é consumida nos mesmos [ADENE], é importante operar no sentido de promover a utilização racional de energia e incentivar ao consumo eficiente da mesma nos edifícios. Apesar do esforço que tem sido realizado a nível nacional, no sentido de melhorar a eficiência energética em edifícios de serviços, através da implementação de legislação diversa e de vários programas de incentivo, existem ainda várias lacunas a serem colmatadas e muito trabalho a fazer nesse sentido. Por tudo isto, e principalmente por ter constantemente em mente premissas como “a energia mais barata é aquela que não se consome” ou “não podemos gerir aquilo que não medimos”, surgiu a ideia de realizar esta dissertação, onde inicialmente através de dados provenientes de telecontagem se desenvolve uma tentativa de padronização/tipificação do consumo eléctrico em seis edifícios de escritórios, identificando-se assim algumas situações anómalas em diversos diagramas de carga construídos. Relaciona-se também o consumo eléctrico dos seis edifícios com algumas variáveis exógenas, de modo a perceber a influência das mesmas no consumo eléctrico de cada edifício. Numa vertente mais prática, foram identificadas e quantificadas potenciais medidas de melhoria, comportamentais e técnicas, num dos edifícios em estudo, de modo a poder contribuir para a redução do consumo energético do mesmo. Espera-se que este trabalho, possa eventualmente constituir uma ajuda na caracterização de consumos e detecção de medidas de melhoria em edifícios de escritórios, alcançando a eficiência energética neste tipo de instalações e facilitando assim o trabalho de vários profissionais do sector. Pretende-se igualmente demonstrar a importância da eficiência energética na gestão do uso da energia eléctrica em edifícios, e efectuar um paralelo entre a energia economizada por meio da implementação de medidas/acções de uso racional e eficiente, com a redução da queima de combustíveis fosseis na geração de energia eléctrica e a sua consequente redução nas emissões de dióxido de carbono (CO2), com o objectivo final de melhorar a qualidade de vida no nosso planeta.
Resumo:
Portugal é um país dependente da energia do exterior, devido à elevada percentagem de consumo de energia a partir de fontes primárias, como por exemplo o gasóleo. Para colmatar este cenário, têm vindo a criar-se incentivos para o uso de energias renováveis e para intensificação de medidas de eficiência energética, como os sistemas de cogeração, de forma a tornar os processos industriais nacionais mais autónomos e mais competitivos. O presente trabalho, centra-se na determinação do potencial térmico disponível na central de trigeração da empresa Monteiro, Ribas-Indústria, SA, com a finalidade de identificar a quantidade de energia não utilizada, com vista ao aproveitamento dessa mesma energia nos processos mais problemáticos da empresa. Verificou-se que a água líquida era a fonte de maior energia não aproveitada, representando cerca de 30%, relativamente à energia disponível na água de refrigeração que é de 1890 kW. Assim, perante este facto, fez-se um estudo em dois setores autónomos da empresa, o setor dos revestimentos e o setor dos componentes técnicos da borracha. Pretendeu-se propor medidas para melhorar os seus processos produtivos, aproveitando essa energia. Para o efeito foi projetado um permutador de calor de placas com necessidade energética de 131,4 MWh, no setor dos revestimentos e um permutador compacto no setor de produção de placas de borracha, necessitando de uma energia de 335,2 MWh. Face à energia disponível na central de trigeração, de 161,9 MWh, verifica-se que esta apenas poderá ser aproveitada no setor dos revestimentos. Para tornar este objetivo real, a empresa Monteiro, Ribas- Indústria, SA necessitaria de efetuar um investimento no total de 49.390€. Além disso, foi contabilizado o rendimento das caldeiras da central térmica e da cogeração, ambas pelo método direto, apresentando estas os valores de 72% e 42%, respectivamente.