32 resultados para Energy analysis
em Instituto Politécnico do Porto, Portugal
Resumo:
4th International Conference on Climbing and Walking Robots - From Biology to Industrial Applications
Resumo:
Mestrado em Engenharia Mecânica
Resumo:
This paper presents the dynamic analysis of robotic biped systems. The main goal is to gain insight into the phenomena of walking and to evaluate its performance. In this study, we propose three methods to quantitatively measure the dynamic efficiency of walking: energy analysis, perturbation analysis and lowpass frequency analysis. In order to accomplish this goal, the prescribed motion of the biped is completely characterised in terms of a set of locomotion variables, namely: step lenght, hip height, hip ripple, hip offset, foot clearance and link lenghts. based on these variables and their influence, the performance measures aer discussed and the results compared with those observed in nature.
Resumo:
O recurso às energias renováveis é na actualidade um tema que atinge um grau de importância primordial face á crescente preocupação com o meio ambiente e o impacto negativo, que a produção de energia com base em combustíveis fósseis tem. Esta importância aliada a uma tendência cada vez maior para a criação de soluções de produção sustentável de energia, tem obrigado ao desenvolvimento desta vertente do sector energético e ao estudo e consequentemente implementação de soluções integradas que permitam uma economia competitiva. Os hotéis, sendo estabelecimentos comerciais que desenvolvem uma actividade que envolve, na generalidade, um nível de consumo energético considerável para garantir os seus serviços básicos de acomodação e lazer, tornam-se por excelência alvos primordiais no que concerne ao seu elevado potencial de poupança de energia. O ramo da hotelaria, dada a sua especificidade e a natureza dos edifícios que comporta, torna-os em excelentes candidatos para análise e optimização energética, e como tal um alvo de negócio para as empresas de comercialização de poupanças energéticas. As empresas dedicadas aos serviços de energia são conhecidas por ESCO (Energy Service Company ou Energy Savings Company). A sua actividade tem por base apresentar soluções de energia, nomeadamente a implementação de projectos de poupança energética que podem englobar produção, conservação e fornecimento de energia, bem como gestão de risco associada. O objectivo principal é apresentar soluções de optimização e eficiência energética levando á sua implementação em casos reais de exploração em edifícios ou sectores específicos, rentabilizando o investimento e partilhando o lucro dessa rentabilização com os clientes. No caso específico dos hotéis, mais concretamente um complexo de hotéis, como o estudado neste trabalho, esta análise pretende elaborar uma caracterização das necessidades energéticas do sector e apresentar um conjunto de soluções energéticas adequadas à realidade hoteleira. É também objecto de análise, toda a aproximação de um modelo de negócio energético a explorar por uma ESCO. O presente trabalho, realizado no âmbito da parceria entre a Gebio e a Confraria do Bom Jesus, tem por objectivo demonstrar as bases do contracto de performance entre uma empresa ESCO (Gebio – empresa concessionária do projecto) e um complexo de hotéis (constituído pelo Hotel do Lago, Hotel do Parque e Hotel do Templo), com vista a optimizar os consumos energéticos para a produção de energia térmica capaz de corresponder às necessidades do complexo. Foi desenvolvido um estudo completo das necessidades térmicas do complexo, com vista a projectar uma solução integrada de produção de energia térmica, com recurso a uma caldeira de biomassa, para os hotéis. Foi realizado um levantamento extensivo dos consumos e custos energético do complexo, nomeadamente para as águas quentes sanitárias. Desta análise obtiveram-se os custos reais do sistema e com os mesmos foi possível, numa primeira fase, elaborar os diversos projectos, hidráulico, eléctricos e civil, de forma a se definir a solução base e quais os orçamentos previstos para a instalação de um sistema de produção a biomassa, e numa segunda fase foi estudada a viabilidade da assinatura de um contracto de performance entre a ESCO e o complexo de hotéis.
Resumo:
Uma nova área tecnológica está em crescente desenvolvimento. Esta área, denominada de internet das coisas, surge na necessidade de interligar vários objetos para uma melhoria a nível de serviços ou necessidades por parte dos utilizadores. Esta dissertação concentra-se numa área específica da tecnologia internet das coisas que é a sensorização. Esta rede de sensorização é implementada pelo projeto europeu denominado de Future Cities [1] onde se cria uma infraestrutura de investigação e validação de projetos e serviços inteligentes na cidade do Porto. O trabalho realizado nesta dissertação insere-se numa das plataformas existentes nessa rede de sensorização: a plataforma de sensores ambientais intitulada de UrbanSense. Estes sensores ambientais que estão incorporados em Data Collect Unit (DCU), também denominados por nós, medem variáveis ambientais tais como a temperatura, humidade, ozono e monóxido de carbono. No entanto, os nós têm recursos limitados em termos de energia, processamento e memória. Apesar das grandes evoluções a nível de armazenamento e de processamento, a nível energético, nomeadamente nas baterias, não existe ainda uma evolução tão notável, limitando a sua operacionalidade [2]. Esta tese foca-se, essencialmente, na melhoria do desempenho energético da rede de sensores UrbanSense. A principal contribuição é uma adaptação do protocolo de redes Ad Hoc OLSR (Optimized Link State Routing Protocol) para ser usado por nós alimentados a energia renovável, de forma a aumentar a vida útil dos nós da rede de sensorização. Com esta contribuição é possível obter um maior número de dados durante períodos de tempo mais longos, aproximadamente 10 horas relativamente às 7 horas anteriores, resultando numa maior recolha e envio dos mesmos com uma taxa superior, cerca de 500 KB/s. Existindo deste modo uma aproximação analítica dos vários parâmetros existentes na rede de sensorização. Contudo, o aumento do tempo de vida útil dos nós sensores com recurso à energia renovável, nomeadamente, energia solar, incrementa o seu peso e tamanho que limita a sua mobilidade. Com o referido acréscimo a determinar e a limitar a sua mobilidade exigindo, por isso, um planeamento prévio da sua localização. Numa primeira fase do trabalho analisou-se o consumo da DCU, visto serem estes a base na infraestrutura e comunicando entre si por WiFi ou 3G. Após uma análise dos protocolos de routing com iv suporte para parametrização energética, a escolha recaiu sobre o protocolo OLSR devido à maturidade e compatibilidade com o sistema atual da DCU, pois apesar de existirem outros protocolos, a implementação dos mesmos, não se encontram disponível como software aberto. Para a validação do trabalho realizado na presente dissertação, é realizado um ensaio prévio sem a energia renovável, para permitir caracterização de limitações do sistema. Com este ensaio, tornou-se possível verificar a compatibilidade entre os vários materiais e ajustamento de estratégias. Num segundo teste de validação é concretizado um ensaio real do sistema com 4 nós a comunicar, usando o protocolo com eficiência energética. O protocolo é avaliado em termos de aumento do tempo de vida útil do nó e da taxa de transferência. O desenvolvimento da análise e da adaptação do protocolo de rede Ad Hoc oferece uma maior longevidade em termos de tempo de vida útil, comparando ao que existe durante o processamento de envio de dados. Apesar do tempo de longevidade ser inferior, quando o parâmetro energético se encontra por omissão com o fator 3, a realização da adaptação do sistema conforme a energia, oferece uma taxa de transferência maior num período mais longo. Este é um fator favorável para a abertura de novos serviços de envio de dados em tempo real ou envio de ficheiros com um tamanho mais elevado.
Resumo:
In this abstract is presented an energy management system included in a SCADA system existent in a intelligent home. The system control the home energy resources according to the players definitions (electricity consumption and comfort levels), the electricity prices variation in real time mode and the DR events proposed by the aggregators.
Resumo:
The purpose of this study is to analyse the interlimb relation and the influence of mechanical energy on metabolic energy expenditure during gait. In total, 22 subjects were monitored as to electromyographic activity, ground reaction forces and VO2 consumption (metabolic power) during gait. The results demonstrate a moderate negative correlation between the activity of tibialis anterior, biceps femoris and vastus medialis of the trailing limb during the transition between midstance and double support and that of the leading limb during double support for the same muscles, and between these and gastrocnemius medialis and soleus of the trailing limb during double support. Trailing limb soleus during the transition between mid-stance and double support was positively correlated to leading limb tibialis anterior, vastus medialis and biceps femoris during double support. Also, the trailing limb centre of mass mechanical work was strongly influenced by the leading limbs, although only the mechanical power related to forward progression of both limbs was correlated to metabolic power. These findings demonstrate a consistent interlimb relation in terms of electromyographic activity and centre of mass mechanical work, being the relations occurred in the plane of forward progression the more important to gait energy expenditure.
Resumo:
The implementation of smart homes allows the domestic consumer to be an active player in the context of the Smart Grid (SG). This paper presents an intelligent house management system that is being developed by the authors to manage, in real time, the power consumption, the micro generation system, the charge and discharge of the electric or plug-in hybrid vehicles, and the participation in Demand Response (DR) programs. The paper proposes a method for the energy efficiency analysis of a domestic consumer using the SCADA House Intelligent Management (SHIM) system. The main goal of the present paper is to demonstrate the economic benefits of the implemented method. The case study considers the consumption data of some real cases of Portuguese house consumption over 30 days of June of 2012, the Portuguese real energy price, the implementation of the power limits at different times of the day and the economic benefits analysis.
Resumo:
O documento em anexo encontra-se na versão post-print (versão corrigida pelo editor).
Resumo:
This paper reports a novel application of microwave-assisted extraction (MAE) of polyphenols from brewer’s spent grains (BSG). A 24 orthogonal composite design was used to obtain the optimal conditions of MAE. The influence of the MAE operational parameters (extraction time, temperature, solvent volume and stirring speed) on the extraction yield of ferulic acid was investigated through response surface methodology. The results showed that the optimal conditions were 15 min extraction time, 100 °C extraction temperature, 20 mL of solvent, and maximum stirring speed. Under these conditions, the yield of ferulic acid was 1.31±0.04% (w/w), which was fivefold higher than that obtained with conventional solid–liquid extraction techniques. The developed new extraction method considerably reduces extraction time, energy and solvent consumption, while generating fewer wastes. HPLC-DADMS analysis indicated that other hydroxycinnamic acids and several ferulic acid dehydrodimers, as well as one dehydrotrimer were also present, confirming that BSG is a valuable source of antioxidant compounds.
Resumo:
For the past years wireless sensor networks (WSNs) have been coined as one of the most promising technologies for supporting a wide range of applications. However, outside the research community, few are the people who know what they are and what they can offer. Even fewer are the ones that have seen these networks used in real world applications. The main obstacle for the proliferation of these networks is energy, or the lack of it. Even though renewable energy sources are always present in the networks environment, designing devices that can efficiently scavenge that energy in order to sustain the operation of these networks is still an open challenge. Energy scavenging, along with energy efficiency and energy conservation, are the current available means to sustain the operation of these networks, and can all be framed within the broader concept of “Energetic Sustainability”. A comprehensive study of the several issues related to the energetic sustainability of WSNs is presented in this thesis, with a special focus in today’s applicable energy harvesting techniques and devices, and in the energy consumption of commercially available WSN hardware platforms. This work allows the understanding of the different energy concepts involving WSNs and the evaluation of the presented energy harvesting techniques for sustaining wireless sensor nodes. This survey is supported by a novel experimental analysis of the energy consumption of the most widespread commercially available WSN hardware platforms.
Resumo:
Biodieselhas attracted considerable attention as a renewable, biodegradable, and nontoxic fuel and can contribute to solving the energy problems, significantly reducing the emission of gases which cause global warming. The first stage of this work was to simulate different alternative processes for producing biodiesel. The method used for the production of biodiesel is the transesterification of vegetable oilswith an alcohol in the presence of a catalyst. The raw materials used were palm oils and waste cooking oil. The second stage was a life cycle analysis for all alternatives under study, followed by an economic analysis for the alternatives that present minor impacts and which are more promising from an economic point of view. Finally,we proceeded to compare the different alternatives fromboth the point of view of life cycle and economic analysis. The feasibility of all processes was proven and the biodiesel obtained had good specifications. From the standpoint of life cycle analysis, the best alternative was the process of alkaline catalysiswith acid pretreatment for waste cooking oil. The economic analysis was done to the previous mentioned process and to the process that uses raw virgin oils, methanol, and sodium hydroxide. This process has lower investment costs but the process of alkaline catalysis with acid pre-treatment, whose main raw material is waste oil, is much more profitable and has less environmental impacts.
Resumo:
The TEM family of enzymes has had a crucial impact on the pharmaceutical industry due to their important role in antibiotic resistance. Even with the latest technologies in structural biology and genomics, no 3D structure of a TEM- 1/antibiotic complex is known previous to acylation. Therefore, the comprehension of their capability in acylate antibiotics is based on the protein macromolecular structure uncomplexed. In this work, molecular docking, molecular dynamic simulations, and relative free energy calculations were applied in order to get a comprehensive and thorough analysis of TEM-1/ampicillin and TEM-1/amoxicillin complexes. We described the complexes and analyzed the effect of ligand binding on the overall structure. We clearly demonstrate that the key residues involved in the stability of the ligand (hot-spots) vary with the nature of the ligand. Structural effects such as (i) the distances between interfacial residues (Ser70−Oγ and Lys73−Nζ, Lys73−Nζ and Ser130−Oγ, and Ser70−Oγ−Ser130−Oγ), (ii) side chain rotamer variation (Tyr105 and Glu240), and (iii) the presence of conserved waters can be also influenced by ligand binding. This study supports the hypothesis that TEM-1 suffers structural modifications upon ligand binding.
Resumo:
The simulation analysis is important approach to developing and evaluating the systems in terms of development time and cost. This paper demonstrates the application of Time Division Cluster Scheduling (TDCS) tool for the configuration of IEEE 802.15.4/ZigBee beaconenabled cluster-tree WSNs using the simulation analysis, as an illustrative example that confirms the practical applicability of the tool. The simulation study analyses how the number of retransmissions impacts the reliability of data transmission, the energy consumption of the nodes and the end-to-end communication delay, based on the simulation model that was implemented in the Opnet Modeler. The configuration parameters of the network are obtained directly from the TDCS tool. The simulation results show that the number of retransmissions impacts the reliability, the energy consumption and the end-to-end delay, in a way that improving the one may degrade the others.
Resumo:
The performance of the Weather Research and Forecast (WRF) model in wind simulation was evaluated under different numerical and physical options for an area of Portugal, located in complex terrain and characterized by its significant wind energy resource. The grid nudging and integration time of the simulations were the tested numerical options. Since the goal is to simulate the near-surface wind, the physical parameterization schemes regarding the boundary layer were the ones under evaluation. Also, the influences of the local terrain complexity and simulation domain resolution on the model results were also studied. Data from three wind measuring stations located within the chosen area were compared with the model results, in terms of Root Mean Square Error, Standard Deviation Error and Bias. Wind speed histograms, occurrences and energy wind roses were also used for model evaluation. Globally, the model accurately reproduced the local wind regime, despite a significant underestimation of the wind speed. The wind direction is reasonably simulated by the model especially in wind regimes where there is a clear dominant sector, but in the presence of low wind speeds the characterization of the wind direction (observed and simulated) is very subjective and led to higher deviations between simulations and observations. Within the tested options, results show that the use of grid nudging in simulations that should not exceed an integration time of 2 days is the best numerical configuration, and the parameterization set composed by the physical schemes MM5–Yonsei University–Noah are the most suitable for this site. Results were poorer in sites with higher terrain complexity, mainly due to limitations of the terrain data supplied to the model. The increase of the simulation domain resolution alone is not enough to significantly improve the model performance. Results suggest that error minimization in the wind simulation can be achieved by testing and choosing a suitable numerical and physical configuration for the region of interest together with the use of high resolution terrain data, if available.