130 resultados para Drying energy saving
em Instituto Politécnico do Porto, Portugal
Resumo:
Energy consumption is one of the major issues for modern embedded systems. Early, power saving approaches mainly focused on dynamic power dissipation, while neglecting the static (leakage) energy consumption. However, technology improvements resulted in a case where static power dissipation increasingly dominates. Addressing this issue, hardware vendors have equipped modern processors with several sleep states. We propose a set of leakage-aware energy management approaches that reduce the energy consumption of embedded real-time systems while respecting the real-time constraints. Our algorithms are based on the race-to-halt strategy that tends to run the system at top speed with an aim to create long idle intervals, which are used to deploy a sleep state. The effectiveness of our algorithms is illustrated with an extensive set of simulations that show an improvement of up to 8% reduction in energy consumption over existing work at high utilization. The complexity of our algorithms is smaller when compared to state-of-the-art algorithms. We also eliminate assumptions made in the related work that restrict the practical application of the respective algorithms. Moreover, a novel study about the relation between the use of sleep intervals and the number of pre-emptions is also presented utilizing a large set of simulation results, where our algorithms reduce the experienced number of pre-emptions in all cases. Our results show that sleep states in general can save up to 30% of the overall number of pre-emptions when compared to the sleep-agnostic earliest-deadline-first algorithm.
Resumo:
O objectivo desta tese é dimensionar um secador em leito fluidizado para secagem de cereais, nomeadamente, secagem de sementes de trigo. Inicialmente determinaram-se as condições de hidrodinâmica (velocidade de fluidização, TDH, condições mínimas de “slugging”, expansão do leito, dimensionamento do distribuidor e queda de pressão). Com as condições de hidrodinâmica definidas, foi possível estimar as dimensões físicas do secador. Neste ponto, foram realizados estudos relativamente à cinética da secagem e à própria secagem. Foi também estudado o transporte pneumático das sementes. Deste modo, determinaram-se as velocidades necessárias ao transporte pneumático e respectivas quedas de pressão. Por fim, foi realizada uma análise custos para que se soubesse o custo deste sistema de secagem. O estudo da secagem foi feito para uma temperatura de operação de 50ºC, tendo a ressalva que no limite se poderia trabalhar com 60ºC. A velocidade de operação é de 2,43 m/s, a altura do leito fixo é de 0,4 m, a qual sofre uma expansão durante a fluidização, assumindo o valor de 0,79 m. O valor do TDH obtido foi de 1,97 m, que somado à expansão do leito permite obter uma altura total da coluna de 2,76 m. A altura do leito fixo permite retirar o valor do diâmetro que é de 0,52 m. Verifica-se que a altura do leito expandido é inferior à altura mínima de “slugging” (1,20 m), no entanto, a velocidade de operação é superior à velocidade mínima de “slugging” (1,13 m/s). Como só uma das condições mínimas é cumprida, existe a possibilidade da ocorrência de “slugging”. Finalmente, foi necessário dimensionar o distribuidor, que com o diâmetro de orifício de 3 mm, valor inferior ao da partícula (3,48 mm), permite a distruibuição do fluido de secagem na coluna através dos seus 3061 orifícios. O inicio do estudo da secagem centrou-se na determinação do tempo de secagem. Além das duas temperaturas atrás referidas, foram igualmente consideradas duas humidades iniciais para os cereais (21,33% e 18,91%). Temperaturas superiores traduzem-se em tempos de secagem inferiores, paralelamente, teores de humidade inicial inferiores indicam tempos menores. Para a temperatura de 50ºC, os tempos de secagem assumiram os valores de 2,8 horas para a 21,33% de humidade e 2,7 horas para 18,91% de humidade. Foram também tidas em conta três alturas do ano para a captação do ar de secagem, Verão e Inverno representando os extremos, e a Meia- Estação. Para estes três casos, foi possível verificar que a humidade específica do ar não apresenta alterações significativas entre a entrada no secador e a corrente de saída do mesmo equipamento, do mesmo modo que a temperatura de saída pouco difere da de entrada. Este desvio de cerca de 1% para as humidades e para as temperaturas é explicado pela ausência de humidade externa nas sementes e na pouca quantidade de humidade interna. Desta forma, estes desvios de 1% permitem a utilização de uma razão de reciclagem na ordem dos 100% sem que o comportamento da secagem se altere significativamente. O uso de 100% de reciclagem permite uma poupança energética de cerca de 98% no Inverno e na Meia-Estação e de cerca de 93% no Verão. Caso não fosse realizada reciclagem, seria necessário fornecer à corrente de ar cerca de 18,81 kW para elevar a sua temperatura de 20ºC para 50ºC (Meia-Estação), cerca de 24,67 kW para elevar a sua temperatura de 10ºC para 50ºC (Inverno) e na ordem dos 8,90 kW para elevar a sua temperatura dos 35ºC para 50ºC (Verão). No caso do transporte pneumático, existem duas linhas, uma horizontal e uma vertical, logo foi necessário estimar o valor da velocidade das partículas para estes dois casos. Na linha vertical, a velocidade da partícula é cerca de 25,03 m/s e cerca de 35,95 m/s na linha horizontal. O menor valor para a linha vertical prende-se com o facto de nesta zona ter que se vencer a força gravítica. Em ambos os circuitos a velocidade do fluido é cerca de 47,17 m/s. No interior da coluna, a velocidade do fluido tem o valor de 10,90 m/s e a velocidade das partículas é de 1,04 m/s. A queda de pressão total no sistema é cerca de 2408 Pa. A análise de custos ao sistema de secagem indicou que este sistema irá acarretar um custo total (fabrico mais transporte) de cerca de 153035€. Este sistema necessita de electricidade para funcionar, e esta irá acarretar um custo anual de cerca de 7951,4€. Embora este sistema de secagem apresente a possibilidade de se realizar uma razão de reciclagem na ordem dos 100% e também seja possível adaptar o mesmo para diferentes tipos de cereais, e até outros tipos de materiais, desde que possam ser fluidizados, o seu custo impede que a realização deste investimento não seja atractiva, especialmente tendo em consideração que se trata de uma instalação à escala piloto com uma capacidade de 45 kgs.
Resumo:
The global warming due to high CO2 emission in the last years has made energy saving a global problem nowadays. However, manufacturing processes such as pultrusion necessarily needs heat for curing the resin. Then, the only option available is to apply all efforts to make the process even more efficient. Different heating systems have been used on pultrusion, however, the most widely used are the planar resistances. The main objective of this study is to develop another heating system and compares it with the former one. Thermography was used in spite of define the temperature profile along the die. FEA (finite element analysis) allows to understand how many energy is spend with the initial heating system. After this first approach, changes were done on the die in order to test the new heating system and to check possible quality problems on the product. Thus, this work allows to conclude that with the new heating system a significant reduction in the setup time is now possible and an energy reduction of about 57% was achieved.
Resumo:
Sleep-states are emerging as a first-class design choice in energy minimization. A side effect of this is that the release behavior of the system is affected and subsequently the preemption relations between tasks. In a first step we have investigated how the behavior in terms of number of preemptions of tasks in the system is changed at runtime, using an existing procrastination approach, which utilizes sleepstates for energy savings purposes. Our solution resulted in substantial savings of preemptions and we expect from even higher yields for alternative energy saving algorithms. This work is intended to form the base of future research, which aims to bound the number of preemptions at analysis time and subsequently how this may be employed in the analysis to reduced the amount of system utilization, which is reserved to account for the preemption delay.
Resumo:
In this study the potential eco-efficiency performance of a pultrusion manufacturing company was assessed. Indicators values and eco-efficiency ratios were estimated taking into account the implementation of new proceedings and procedures in the production process of glass fibre reinforced polymers (GFRP) pultrusion profiles. Two different approaches were foreseen: 1)Adoption of a new heating system for pultrusion die in the manufacturing process, more effective and with minor heat losses; and 2) Recycling approach, with partial waste reuse of scrap material derived from manufacturing, cutting and assembly processes of GFRP profiles. These features lead to significant improvements on the sequent assessed eco-efficiency ratios of the present case study, yielding to a more sustainable product and manufacturing process of pultruded GFRP profiles.
Resumo:
A civilização contemporânea, pelas suas características, é muito exigente em tudo o que diz respeito ao conforto dos edifícios, para trabalho ou habitação, e à necessidade de economizar e racionalizar o uso de energia. A térmica dos edifícios assume, por isso, uma importância acrescida na atividade profissional e no ensino. Para se conduzir ao aperfeiçoamento de soluções na envolvente dos edifícios a este nível, o trabalho aqui realizado centrou-se no estudo do funcionamento da termografia de infravermelhos e da importância da sua utilização na inspeção térmica de edifícios. Descoberta no início do século XIX e desenvolvendo os primeiros sistemas operativos desde a 1ª Guerra Mundial, a fim de determinar heterogeneidades de temperatura superficial, esta técnica não destrutiva permite identificar anomalias que não são visualizadas a olho nu. Com a análise dessas variações de temperatura é possível conhecer os problemas e a localização de irregularidades. Este trabalho baseia-se substancialmente no estudo de edifícios. A análise realizada teve como finalidade executar inspeções termográficas – visuais, com duas abordagens. Por um lado, avaliar salas pertencentes a estabelecimentos de ensino secundário, reabilitadas e não reabilitadas, todas construídas entre as décadas de 60 e 90, com o intuito de diagnosticar patologias construtivas, recorrendo à termografia. Por outro, a análise de edifícios de habitação, com a intenção de avaliar a necessidade de um equipamento complementar às inspeções termográficas – o sistema de porta ventiladora. As inspeções foram regidas pelas diretrizes da norma europeia EN 13187. A termografia é uma técnica importante na realização de ensaios in situ que requerem rapidez de execução, aliada à vantagem de disponibilizar resultados em tempo real, permitindo assim uma primeira análise das leituras no local. A inspeção termográfica complementada com o sistema de porta ventiladora permitiu, também, revelar a importância da necessidade de meios auxiliares em certos casos. A conjugação destas diferentes técnicas permite reduzir a subjetividade da análise in situ e aumentar a fiabilidade do diagnóstico.
Resumo:
O consumo energético verificado nas refinarias petrolíferas é muito elevado, sendo as fornalhas os equipamentos que mais contribuem para esse consumo. Neste estudo foi efetuada uma avaliação e otimização energética às fornalhas da Fábrica de Aromáticos da Refinaria de Matosinhos. Numa primeira fase foi efetuado um levantamento exaustivo de dados de todas as correntes de entrada e saída dos equipamentos para posteriormente efetuar os balanços de massa e energia a cada uma das fornalhas. Os dados relativos ao levantamento compreenderam dois períodos de funcionamento distintos da unidade fabril, o período de funcionamento normal e o período relativo ao arranque. O período de funcionamento normal foi relativo ao ano de 2012 entre os meses de janeiro a setembro, por sua vez o período de arranque foi de dezembro de 2012 a março de 2013. Na segunda fase foram realizados os balanços de massa e energia quantificando todas as correntes de entrada e saída das fornalhas em termos mássicos e energéticos permitindo o cálculo do rendimento térmico das fornalhas para avaliar a sua performance. A avaliação energética permitiu concluir que existe um consumo maior de energia proveniente da combustão do Fuel Gás do que do Fuel Óleo, tanto no período de funcionamento normal como no arranque. As fornalhas H0101, H0301 e a H0471 possuem os consumos mais elevados, sendo responsáveis por mais de 70% do consumo da Fábrica de Aromáticos. Na terceira fase foram enunciadas duas medidas para a otimização energética das três fornalhas mais consumidoras de energia, a limpeza mensal e o uso exclusivo de Fuel Gás como combustível. As poupanças energéticas obtidas para uma limpeza mensal foram de 0,3% na fornalha H0101, 0,7% na fornalha H0301 e uma poupança de 0,9 % na fornalha H0471. Para o uso exclusivo de Fuel Gás obteve-se uma poupança de 0,9% na fornalha H0101 e uma poupança de 1,3% nas fornalhas H0301 e H0471. A análise económica efetuada à sugestão de alteração do combustível mostra que os custos de operação sofrerão um aumento anual de 621 679 €. Apesar do aumento dos custos, a redução na emissão de 24% de dióxido de carbono, poderá justificar este aumento na despesa.
Resumo:
Os crescentes custos ligados ao consumo elétrico, não apenas de cariz financeiro mas também ambiental, despertam cada vez mais para a importância da definição de estratégias de melhor utilização de recursos e eficiência energética. Esta importância tem sido reforçada pela definição de decretos-lei que vêm colocar metas e limites relativamente às despesas energéticas. Estes diplomas são também acompanhados por programas de incentivo para um setor ligado à eficiência energética. Em Portugal as medidas ligadas ao setor tem vindo a ser redirecionadas para o consumo final de energia, com a definição de metas para as instalações de maior consumo. As instalações hospitalares são grandes centros de consumo energético devido não só ao elevado número de utentes que recebem mas também pelos diversos tipos de equipamentos elétricos usados para a prestação dos serviços médicos. Como consequência disso, os investimentos e os custos operacionais são elevados, o que reforça a necessidade de gerir os gastos e consumos energéticos com a procura constante de melhoria na recolha de informação sobre todo o sistema e na adequação de intervenções com vista a uma maior eficiência energética. O Hospital Pedro Hispano vem desde algum tempo a investir no sentido de conhecer mais e melhor toda a instalação bem como os consumos energéticos a ela associados. Algumas medidas foram tomadas nesse sentido nomeadamente a instalação de analisadores de energia, de modo a obter um retrato mais fiel e fidedigno dos principais vetores de consumo. Neste momento a gestão técnica do hospital tem em análise uma grande parte da instalação recolhendo dados do consumo elétrico real do hospital. Nesta dissertação procurou-se fazer uma análise e enquadramento dos programas e metas ligados ao setor energético com ênfase nos diplomas que visão e abrangem as instalações hospitalares. Dos vários programas de incentivo à adoção de políticas de maior eficiência energética é dado especial destaque ao programa ECO.AP que visa a celebração de contratos para implementação de medidas de poupança energética ao setor público. Em colaboração com o HPH, iniciaram-se os trabalhos pelo estudo e identificação das principais fases e ferramentas utilizadas na gestão energética do edifício tendo como objetivo a reavaliação dos vetores energéticos já identificados no HPH e a criação e contabilização de novos grupos de consumo. Através de várias medições do consumo elétrico, num total superior a 650 horas de funcionamento, foi possível a criação do mapa de desagregação de consumos para o ano de 2013. A desagregação realizada conta com 3 novos vetores energéticos e com a reavaliação do peso relativo de mais 5 grupos de consumo. Das medições efetuadas destaca-se a reavaliação do consumo da central de bombagem onde a parcela considerada até à data estava 3 vezes acima do valor real medido. Com base na desagregação feita foram apontadas e estudadas medidas de implementação com o objetivo de reduzir os consumos energético em todo o hospital, destacando-se a solução apresentada para a central de bombagem. Esta medida traria um grande impacto em toda a fatura energética, não só pela sua viabilidade, mas também porque atuaria num grande centro de consumo onde até ao momento nenhuma ação do género foi implementada.
Resumo:
Esta dissertação descreve o sistema de apoio à racionalização da utilização de energia eléctrica desenvolvido no âmbito da unidade curricular de Tese/Dissertação. O domínio de aplicação enquadra-se no contexto da Directiva da União Europeia 2006/32/EC que declara ser necessário colocar à disposição dos consumidores a informação e os meios que promovam a redução do consumo e o aumento da eficiência energética individual. O objectivo é o desenvolvimento de uma solução que permita a representação gráfica do consumo/produção, a definição de tectos de consumo, a geração automática de alertas e alarmes, a comparação anónima com clientes com perfil idêntico por região e a previsão de consumo/produção no caso de clientes industriais. Trata-se de um sistema distribuído composto por front-end e back-end. O front-end é composto pelas aplicações de interface com o utilizador desenvolvidas para dispositivos móveis Android e navegadores Web. O back-end efectua o armazenamento e processamento de informação e encontra-se alojado numa plataforma de cloud computing – o Google App Engine – que disponibiliza uma interface padrão do tipo serviço Web. Esta opção assegura interoperabilidade, escalabilidade e robustez ao sistema. Descreve-se em detalhe a concepção, desenvolvimento e teste do protótipo realizado, incluindo: (i) as funcionalidades de gestão e análise de consumo e produção de energia implementadas; (ii) as estruturas de dados; (iii) a base de dados e o serviço Web; e (iv) os testes e a depuração efectuados. (iv) Por fim, apresenta-se o balanço deste projecto e efectuam-se sugestões de melhoria.
Resumo:
Multi-standard mobile devices are allowing users to enjoy higher data rates with ubiquitous connectivity. However, the benefits gained from multiple interfaces come at an expense—that being higher energy consumption in an era where mobile devices need to be energy compliant. One promising solution is the usage of short-range cooperative communication as an overlay for infrastructure-based networks taking advantage of its context information. However, the node discovery mechanism, which is pivotal to the bearer establishment process, still represents a major burden in terms of the total energy budget. In this paper, we propose a technology agnostic approach towards enhancing the MAC energy ratings by presenting a context-aware node discovery (CANDi) algorithm, which provides a priori knowledge towards the node discovery mechanism by allowing it to search nodes in the near vicinity at the ‘right time and at the right place’. We describe the different beacons required for establishing the cooperation, as well as the context information required, including battery level, modes, location and so on. CANDi uses the long-range network (WiMAX and WiFi) to distribute the context information about cooperative clusters (Ultra-wideband-based) in the vicinity. The searching nodes can use this context in locating the cooperative clusters/nodes, which facilitates the establishing of short-range connections. Analytical and simulation results are obtained, and the energy saving gains are further demonstrated in the laboratory using a customised testbed. CANDi saves up to 50% energy during the node discovery process, while the demonstrative testbed shows up to 75% savings in the total energy budget, thus validating the algorithm, as well as providing viable evidence to support the usage of short-range cooperative communications for energy savings.
Resumo:
The evolution of the electrical grid into a smart grid, allowing user production, storage and exchange of energy, remote control of appliances, and in general optimizations over how the energy is managed and consumed, is also an evolution into a complex Information and Communication Technology (ICT) system. With the goal of promoting an integrated and interoperable smart grid, a number of organizations all over the world started uncoordinated standardization activities, which caused the emergence of a large number of incompatible architectures and standards. There are now new standardization activities which have the goal of organizing existing standards and produce best practices to choose the right approach(es) to be employed in specific smart grid designs. This paper follows the lead of NIST and ETSI/CEN/CENELEC approaches in trying to provide taxonomy of existing solutions; our contribution reviews and relates current ICT state-of-the-art, with the objective of forecasting future trends based on the orientation of current efforts and on relationships between them. The resulting taxonomy provides guidelines for further studies of the architectures, and highlights how the standards in the last mile of the smart grid are converging to common solutions to improve ICT infrastructure interoperability.
Resumo:
O recurso às energias renováveis é na actualidade um tema que atinge um grau de importância primordial face á crescente preocupação com o meio ambiente e o impacto negativo, que a produção de energia com base em combustíveis fósseis tem. Esta importância aliada a uma tendência cada vez maior para a criação de soluções de produção sustentável de energia, tem obrigado ao desenvolvimento desta vertente do sector energético e ao estudo e consequentemente implementação de soluções integradas que permitam uma economia competitiva. Os hotéis, sendo estabelecimentos comerciais que desenvolvem uma actividade que envolve, na generalidade, um nível de consumo energético considerável para garantir os seus serviços básicos de acomodação e lazer, tornam-se por excelência alvos primordiais no que concerne ao seu elevado potencial de poupança de energia. O ramo da hotelaria, dada a sua especificidade e a natureza dos edifícios que comporta, torna-os em excelentes candidatos para análise e optimização energética, e como tal um alvo de negócio para as empresas de comercialização de poupanças energéticas. As empresas dedicadas aos serviços de energia são conhecidas por ESCO (Energy Service Company ou Energy Savings Company). A sua actividade tem por base apresentar soluções de energia, nomeadamente a implementação de projectos de poupança energética que podem englobar produção, conservação e fornecimento de energia, bem como gestão de risco associada. O objectivo principal é apresentar soluções de optimização e eficiência energética levando á sua implementação em casos reais de exploração em edifícios ou sectores específicos, rentabilizando o investimento e partilhando o lucro dessa rentabilização com os clientes. No caso específico dos hotéis, mais concretamente um complexo de hotéis, como o estudado neste trabalho, esta análise pretende elaborar uma caracterização das necessidades energéticas do sector e apresentar um conjunto de soluções energéticas adequadas à realidade hoteleira. É também objecto de análise, toda a aproximação de um modelo de negócio energético a explorar por uma ESCO. O presente trabalho, realizado no âmbito da parceria entre a Gebio e a Confraria do Bom Jesus, tem por objectivo demonstrar as bases do contracto de performance entre uma empresa ESCO (Gebio – empresa concessionária do projecto) e um complexo de hotéis (constituído pelo Hotel do Lago, Hotel do Parque e Hotel do Templo), com vista a optimizar os consumos energéticos para a produção de energia térmica capaz de corresponder às necessidades do complexo. Foi desenvolvido um estudo completo das necessidades térmicas do complexo, com vista a projectar uma solução integrada de produção de energia térmica, com recurso a uma caldeira de biomassa, para os hotéis. Foi realizado um levantamento extensivo dos consumos e custos energético do complexo, nomeadamente para as águas quentes sanitárias. Desta análise obtiveram-se os custos reais do sistema e com os mesmos foi possível, numa primeira fase, elaborar os diversos projectos, hidráulico, eléctricos e civil, de forma a se definir a solução base e quais os orçamentos previstos para a instalação de um sistema de produção a biomassa, e numa segunda fase foi estudada a viabilidade da assinatura de um contracto de performance entre a ESCO e o complexo de hotéis.
Resumo:
O presente trabalho pretende mostrar que a aplicação de medidas de conservação de energia (MCE) pode representar uma redução da intensidade de utilização de matérias-primas na construção de um edifício. Mais concretamente, pode representar uma redução da utilização de materiais e equipamentos, e como consequência, uma redução no esforço económico ao primeiro investimento. Podendo posteriormente representar uma redução na utilização de energia durante o período de funcionamento do edifício. A aplicação de MCE no sector da construção tem vindo a ser uma prática corrente nos novos edifícios e edifícios sujeitos a grandes intervenções de reabilitação. Esta prática deve-se à obrigatoriedade de cumprimento de requisitos regulamentares aplicados à otimização do desempenho energético dos edifícios e dos seus sistemas técnicos, nomeadamente, o RCCTE e o RSECE, entretanto revogados pelo REH e pelo RECS, respetivamente. A implementação de MCE apresenta, na maioria dos casos, benefícios económicos para o promotor do edifício, uma vez que se traduz muitas vezes, na otimização do dimensionamento dos sistemas de Aquecimento, Ventilação e Ar Condicionado (AVAC). Esta otimização permite reduzir os custos associados ao primeiro investimento, bem como na utilização de energia por parte do utilizador, logo na redução dos custos de exploração. No entanto, a falta de quantificação dos impactos do dimensionamento dos sistemas AVAC, da redução de utilização de energia e da análise do custo-benefício da sua aplicação pode condicionar o interesse na sua implementação. Neste contexto, surge a presente dissertação, por iniciativa do Instituto Soldadura e Qualidade (ISQ), aplicado a um caso prático de um edifício já construído e propriedade daquela empresa. Com este trabalho pretende-se avaliar o contributo efetivo das MCE implementadas na fase de projeto e na fase de construção, quer na otimização da dimensão de sistemas e equipamentos AVAC, por via da redução das necessidades energéticas, quer na redução de utilização de energia, permitindo, de seguida, uma avaliação custo-benefício.Na base do caso de estudo está o ECOTERMOLAB, o edifício acima referido, adquirido pelo ISQ para instalação de um laboratório de formação, investigação e desenvolvimento na área da energia. Após aquisição pelo ISQ, o edifício sofreu várias alterações/beneficiações, entre as quais a implementação de MCE, tais como, a aplicação de isolamento térmico na envolvente opaca (paredes, pavimentos e coberturas), duplicação dos vãos envidraçados simples, conferindo-lhes melhores caraterísticas térmicas, e pela aplicação de proteções solar. Foram ainda adotadas MCE aos sistemas AVAC, designadamente, pela adoção de recuperadores de calor nas Unidades de Tratamento de Ar Novo (UTAN’s) e de variadores de velocidade nas bombas de circulação de água e nos ventiladores de ar das UTAN’s. Pretendia o ISQ concluir se a aplicação de todas as MCE contribuiu de forma efetiva para o dimensionamento de sistemas e equipamentos AVAC de menor capacidade e, consequentemente, numa redução de utilização de energia. Em sequência, pretendia avaliar a viabilidade económica da aplicação de todas as MCE, estimando o sobrecusto inicial e o tempo necessário para o retorno financeiro daquele investimento. Para alcançar os objetivos propostos, procedeu-se à simulação energética dinâmica do ECOTERMOLAB, utilizando o programa EnergyPlus. Primeiro foi simulada uma situação base do edifício, sem quaisquer MCE. Posteriormente foi caraterizada cada uma das situações de aplicação das MCE, com o objetivo de avaliar o respetivo impacto individual na utilização de energia pelos sistemas AVAC. Por último foram assumidas todas as soluções em conjunto para avaliar o impacto final de todas as MCE na utilização de energia dos sistemas AVAC, bem como no seu dimensionamento. Das simulações dinâmicas foram obtidos os valores das necessidades de aquecimento e arrefecimento, de energia utilizada pelos sistemas AVAC e de caudais de água aquecida e arrefecida circulada. Com estes valores foi feita uma estimativa de dimensionamento dos equipamentos e componentes AVAC para as situações da aplicação de todas as MCE no ECOTERMOLAB e a sua ausência. A partir da diferença dos custos de aquisição dos respetivos equipamentos e dos valores de poupança em energia foi realizado o estudo da viabilidade económica da implementação das MCE neste edifício. Este estudo permitiu concluir que a aplicação das MCE no ECOTERMOLAB levou à redução da dimensão na generalidade dos equipamentos e componentes AVAC. Permitiu, ainda, concluir que houve uma diminuição de utilização de energia por parte destes sistemas e equipamentos para o aquecimento e arrefecimento. Conclui-se ainda que o período de retorno (Payback) do sobrecusto inicial, estimado em 37.822€ é de, aproximadamente, onze anos e meio, para um valor atual líquido (VAL) de 8.061€ e à taxa interna de rentabilidade (TIR) de 7,03%.
Resumo:
O consumo de energia de forma irracional acarreta desvantagens a nível económico para o consumidor e problemas ambientais para toda a sociedade, como a escassez de recursos naturais e o aumento da poluição. Neste contexto, a otimização energética na indústria, e em particular no setor das borrachas, é indispensável de forma a utilizar racionalmente a energia e assim contribuir para a viabilidade das empresas. Este trabalho, efetuado na Flexocol - Fábrica de Artefactos de Borracha, Lda., teve como principal objetivo efetuar um levantamento energético à unidade fabril e propor alternativas que permitissem a redução do consumo de energia elétrica. Foi ainda realizado um estudo sobre a possibilidade de substituir o n-hexano, solvente utilizado na limpeza dos moldes, por um solvente mais adequado. O levantamento energético efetuado permitiu identificar o consumo das utilidades existentes na Flexocol. Esta empresa consome gasóleo e energia elétrica, sendo esta última, a forma de energia mais consumida correspondendo a 96%. O consumo global de energia é cerca 151 tep anuais, inferior a 500 tep/ano, ou seja é considerada uma empresa não consumidora intensiva de energia. Com base neste levantamento determinou-se os indicadores de consumo específico de energia e da intensidade carbónica, 2,73 tep/ ton e 1684,5 kg CO2/tep. A análise do consumo de energia elétrica dos diferentes equipamentos permitiu verificar que o setor que mais consome energia elétrica é a Vulcanização com 45,8%, seguido do setor da Mistura e Serralharia com 27,5% e 26,7%, respetivamente. O sistema de iluminação nos vários setores foi também alvo de estudo e permitiu identificar a Vulcanização como o setor com mais consumo e o da Mistura como o que menos consome. O estudo das variáveis anteriormente referidas permitiu apresentar algumas propostas de melhoria. Uma das propostas analisada foi implementação de condensadores no quadro parcial de forma a diminuir a energia reativa. Com esta medida prevê-se uma poupança de 5631 €/ano e um retorno de investimento de 0,045 anos. Foi também analisada relativamente à iluminação a possibilidade de instalação de balastros eletrónicos que conduziria a uma poupança na energia elétrica de cerca 7072 kWh/ano, mas com um retorno de investimento desfavorável. Por último estudou-se o solvente alternativo ao n-hexano. A acetona foi o solvente proposto uma vez que tem as propriedades indicadas para o fim a que se destina.
Resumo:
Em 2006, a IEA (Agência Internacional de Energia), publicou alguns estudos de consumos mundiais de energia. Naquela altura, apontava na fabricação de produtos, um consumo mundial de energia elétrica, de origem fóssil de cerca 86,16 EJ/ano (86,16×018 J) e um consumo de energia nos sistemas de vapor de 32,75 EJ/ano. Evidenciou também nesses estudos que o potencial de poupança de energia nos sistemas de vapor era de 3,27 EJ/ano. Ou seja, quase tanto como a energia consumida nos sistemas de vapor da U.E. Não se encontraram números relativamente a Portugal, mas comparativamente com outros Países publicitados com alguma similaridade, o consumo de energia em vapor rondará 0,2 EJ/ano e por conseguinte um potencial de poupança de cerca 0,02 EJ/ano, ou 5,6 × 106 MWh/ano ou uma potência de 646 MW, mais do que a potência de cinco barragens Crestuma/Lever! Trata-se efetivamente de muita energia; interessa por isso perceber o onde e o porquê deste desperdício. De um modo muito modesto, pretende-se com este trabalho dar algum contributo neste sentido. Procurou-se evidenciar as possibilidades reais de os utilizadores de vapor de água na indústria reduzirem os consumos de energia associados à sua produção. Não estão em causa as diferentes formas de energia para a geração de vapor, sejam de origem fóssil ou renovável; interessou neste trabalho estudar o modo de como é manuseado o vapor na sua função de transporte de energia térmica, e de como este poderá ser melhorado na sua eficiência de cedência de calor, idealmente com menor consumo de energia. Com efeito, de que servirá se se optou por substituir o tipo de queima para uma mais sustentável se a jusante se continuarem a verificarem desperdícios, descarga exagerada nas purgas das caldeiras com perda de calor associada, emissões permanentes de vapor para a atmosfera em tanques de condensado, perdas por válvulas nos vedantes, purgadores avariados abertos, pressão de vapor exageradamente alta atendendo às temperaturas necessárias, “layouts” do sistema de distribuição mal desenhados, inexistência de registos de produção e consumos de vapor, etc. A base de organização deste estudo foi o ciclo de vapor: produção, distribuição, consumo e recuperação de condensado. Pareceu importante incluir também o tratamento de água, atendendo às implicações na transferência de calor das superfícies com incrustações. Na produção de vapor, verifica-se que os maiores problemas de perda de energia têm a ver com a falta de controlo, no excesso de ar e purgas das caldeiras em exagero. Na distribuição de vapor aborda-se o dimensionamento das tubagens, necessidade de purgas a v montante das válvulas de controlo, a redução de pressão com válvulas redutoras tradicionais; será de destacar a experiência americana no uso de micro turbinas para a redução de pressão com produção simultânea de eletricidade. Em Portugal não se conhecem instalações com esta opção. Fabricantes da República Checa e Áustria, têm tido sucesso em algumas dezenas de instalações de redução de pressão em diversos países europeus (UK, Alemanha, R. Checa, França, etc.). Para determinação de consumos de vapor, para projeto ou mesmo para estimativa em máquinas existentes, disponibiliza-se uma série de equações para os casos mais comuns. Dá-se especial relevo ao problema que se verifica numa grande percentagem de permutadores de calor, que é a estagnação de condensado - “stalled conditions”. Tenta-se também evidenciar as vantagens da recuperação de vapor de flash (infelizmente de pouca tradição em Portugal), e a aplicação de termocompressores. Finalmente aborda-se o benchmarking e monitorização, quer dos custos de vapor quer dos consumos específicos dos produtos. Esta abordagem é algo ligeira, por manifesta falta de estudos publicados. Como trabalhos práticos, foram efetuados levantamentos a instalações de vapor em diversos sectores de atividades; 1. ISEP - Laboratório de Química. Porto, 2. Prio Energy - Fábrica de Biocombustíveis. Porto de Aveiro. 3. Inapal Plásticos. Componentes de Automóvel. Leça do Balio, 4. Malhas Sonix. Tinturaria Têxtil. Barcelos, 5. Uma instalação de cartão canelado e uma instalação de alimentos derivados de soja. Também se inclui um estudo comparativo de custos de vapor usado nos hospitais: quando produzido por geradores de vapor com queima de combustível e quando é produzido por pequenos geradores elétricos. Os resultados estão resumidos em tabelas e conclui-se que se o potencial de poupança se aproxima do referido no início deste trabalho.