5 resultados para Double-produit
em Instituto Politécnico do Porto, Portugal
Resumo:
This work reports on an experimental and finite element method (FEM) parametric study of adhesively-bonded single and double-strap repairs on carbon-epoxy structures under buckling unrestrained compression. The influence of the overlap length and patch thickness was evaluated. This loading gains a particular significance from the additional characteristic mechanisms of structures under compression, such as fibres microbuckling, for buckling restrained structures, or global buckling of the assembly, if no transverse restriction exists. The FEM analysis is based on the use of cohesive elements including mixed-mode criteria to simulate a cohesive fracture of the adhesive layer. Trapezoidal laws in pure modes I and II were used to account for the ductility of most structural adhesives. These laws were estimated for the adhesive used from double cantilever beam (DCB) and end-notched flexure (ENF) tests, respectively, using an inverse technique. The pure mode III cohesive law was equalled to the pure mode II one. Compression failure in the laminates was predicted using a stress-based criterion. The accurate FEM predictions open a good prospect for the reduction of the extensive experimentation in the design of carbon-epoxy repairs. Design principles were also established for these repairs under buckling.
Resumo:
The structural integrity of multi-component structures is usually determined by the strength and durability of their unions. Adhesive bonding is often chosen over welding, riveting and bolting, due to the reduction of stress concentrations, reduced weight penalty and easy manufacturing, amongst other issues. In the past decades, the Finite Element Method (FEM) has been used for the simulation and strength prediction of bonded structures, by strength of materials or fracture mechanics-based criteria. Cohesive-zone models (CZMs) have already proved to be an effective tool in modelling damage growth, surpassing a few limitations of the aforementioned techniques. Despite this fact, they still suffer from the restriction of damage growth only at predefined growth paths. The eXtended Finite Element Method (XFEM) is a recent improvement of the FEM, developed to allow the growth of discontinuities within bulk solids along an arbitrary path, by enriching degrees of freedom with special displacement functions, thus overcoming the main restriction of CZMs. These two techniques were tested to simulate adhesively bonded single- and double-lap joints. The comparative evaluation of the two methods showed their capabilities and/or limitations for this specific purpose.
Resumo:
Power law (PL) distributions have been largely reported in the modeling of distinct real phenomena and have been associated with fractal structures and self-similar systems. In this paper, we analyze real data that follows a PL and a double PL behavior and verify the relation between the PL coefficient and the capacity dimension of known fractals. It is to be proved a method that translates PLs coefficients into capacity dimension of fractals of any real data.
Resumo:
Power law (PL) distributions have been largely reported in the modeling of distinct real phenomena and have been associated with fractal structures and self-similar systems. In this paper, we analyze real data that follows a PL and a double PL behavior and verify the relation between the PL coefficient and the capacity dimension of known fractals. It is to be proved a method that translates PLs coefficients into capacity dimension of fractals of any real data.
Resumo:
Chronic Low Back Pain (CLBP) is a public health problem and older women have higher incidence of this symptom, which affect body balance, functional capacity and behavior. The purpose of this study was to verifying the effect of exercises with Nintendo Wii on CLBP, functional capacity and mood of elderly. Thirty older women (68 ± 4 years; 68 ± 12 kg; 154 ± 5 cm) with CLBP participated in this study. Elderly individuals were divided into a Control Exercise Group (n = 14) and an Experimental Wii Group (n = 16). Control Exercise Group did strength exercises and core training, while Experimental Wii Group did ones additionally to exercises with Wii. CLBP, balance, functional capacity and mood were assessed pre and post training by the numeric pain scale, Wii Balance Board, sit to stand test and Profile of Mood States, respectively. Training lasted eight weeks and sessions were performed three times weekly. MANOVA 2 x 2 showed no interaction on pain, siting, stand-up and mood (P = 0.53). However, there was significant difference within groups (P = 0.0001). ANOVA 2 x 2 showed no interaction for each variable (P > 0.05). However, there were significant differences within groups in these variables (P < 0.05). Tukey's post-hoc test showed significant difference in pain on both groups (P = 0.0001). Wilcoxon and Mann-Whitney tests identified no significant differences on balance (P > 0.01). Capacity to Sit improved only in Experimental Wii Group (P = 0.04). In conclusion, physical exercises with Nintendo Wii Fit Plus additional to strength and core training were effective only for sitting capacity, but effect size was small.