8 resultados para Darling Center Library

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the application of an intelligent tutoring approach to delivery training in diagnosis procedures of a Power System. In particular, the mechanisms implemented by the training tool to support the trainees are detailed. This tool is part of an architecture conceived to integrate Power Systems tools in a Power System Control Centre, based on an Ambient Intelligent paradigm. The present work is integrated in the CITOPSY project which main goal is to achieve a better integration between operators and control room applications, considering the needs of people, customizing requirements and forecasting behaviors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shopping centers present a rich and heterogeneous environment, where IT systems can be implemented in order to support the needs of its actors. However, due to the environment complexity, several feasibility issues emerge when designing both the logical and physical architecture of such systems. Additionally, the system must be able to cope with the individual needs of each actor, and provide services that are easily adopted by them, taking into account several sociological and economical aspects. In this sense, we present an overview of current support systems for shopping center environments. From this overview, a high-level model of the domain (involving actors and services) is described along with challenges and possible features in the context of current Semantic Web, mobile device and sensor technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A navegação e a interpretação do meio envolvente por veículos autónomos em ambientes não estruturados continua a ser um grande desafio na actualidade. Sebastian Thrun, descreve em [Thr02], que o problema do mapeamento em sistemas robóticos é o da aquisição de um modelo espacial do meio envolvente do robô. Neste contexto, a integração de sistemas sensoriais em plataformas robóticas, que permitam a construção de mapas do mundo que as rodeia é de extrema importância. A informação recolhida desses dados pode ser interpretada, tendo aplicabilidade em tarefas de localização, navegação e manipulação de objectos. Até à bem pouco tempo, a generalidade dos sistemas robóticos que realizavam tarefas de mapeamento ou Simultaneous Localization And Mapping (SLAM), utilizavam dispositivos do tipo laser rangefinders e câmaras stereo. Estes equipamentos, para além de serem dispendiosos, fornecem apenas informação bidimensional, recolhidas através de cortes transversais 2D, no caso dos rangefinders. O paradigma deste tipo de tecnologia mudou consideravelmente, com o lançamento no mercado de câmaras RGB-D, como a desenvolvida pela PrimeSense TM e o subsequente lançamento da Kinect, pela Microsoft R para a Xbox 360 no final de 2010. A qualidade do sensor de profundidade, dada a natureza de baixo custo e a sua capacidade de aquisição de dados em tempo real, é incontornável, fazendo com que o sensor se tornasse instantaneamente popular entre pesquisadores e entusiastas. Este avanço tecnológico deu origem a várias ferramentas de desenvolvimento e interacção humana com este tipo de sensor, como por exemplo a Point Cloud Library [RC11] (PCL). Esta ferramenta tem como objectivo fornecer suporte para todos os blocos de construção comuns que uma aplicação 3D necessita, dando especial ênfase ao processamento de nuvens de pontos de n dimensões adquiridas a partir de câmaras RGB-D, bem como scanners laser, câmaras Time-of-Flight ou câmaras stereo. Neste contexto, é realizada nesta dissertação, a avaliação e comparação de alguns dos módulos e métodos constituintes da biblioteca PCL, para a resolução de problemas inerentes à construção e interpretação de mapas, em ambientes indoor não estruturados, utilizando os dados provenientes da Kinect. A partir desta avaliação, é proposta uma arquitectura de sistema que sistematiza o registo de nuvens de pontos, correspondentes a vistas parciais do mundo, num modelo global consistente. Os resultados da avaliação realizada à biblioteca PCL atestam a sua viabilidade, para a resolução dos problemas propostos. Prova da sua viabilidade, são os resultados práticos obtidos, da implementação da arquitectura de sistema proposta, que apresenta resultados de desempenho interessantes, como também boas perspectivas de integração deste tipo de conceitos e tecnologia em plataformas robóticas desenvolvidas no âmbito de projectos do Laboratório de Sistemas Autónomos (LSA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the joint effects of home environment and center-based child care quality on children’s language, communication, and early literacy development, while also considering prior developmental level. Participants were 95 children (46 boys), assessed as toddlers (mean age = 26.33 months;Time 1) and preschoolers (mean age = 68.71 months; Time 2) and their families. At both times, children attended center-based child care classrooms in the metropolitan area of Porto, Portugal. Results from hierarchical linear models indicated that home environment and preschool quality, but not center-based toddler child care quality, were associated with children’s language and literacy outcomes at Time 2. Moreover, the quality of preschool classrooms moderated the association between home environment quality and children’s language and early literacy skills – but not communication skills – at Time 2, suggesting the positive cumulative effects of home environment and preschool quality. Findings further support the existence of a detrimental effect of low preschool quality on children’s language and early literacy outcomes: positive associations among home environment quality and children’s developmental outcomes were found to reduce substantially when children attended low-quality preschool classrooms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Managing the physical and compute infrastructure of a large data center is an embodiment of a Cyber-Physical System (CPS). The physical parameters of the data center (such as power, temperature, pressure, humidity) are tightly coupled with computations, even more so in upcoming data centers, where the location of workloads can vary substantially due, for example, to workloads being moved in a cloud infrastructure hosted in the data center. In this paper, we describe a data collection and distribution architecture that enables gathering physical parameters of a large data center at a very high temporal and spatial resolutionof the sensor measurements. We think this is an important characteristic to enable more accurate heat-flow models of the data center andwith them, _and opportunities to optimize energy consumption. Havinga high resolution picture of the data center conditions, also enables minimizing local hotspots, perform more accurate predictive maintenance (pending failures in cooling and other infrastructure equipment can be more promptly detected) and more accurate billing. We detail this architecture and define the structure of the underlying messaging system that is used to collect and distribute the data. Finally, we show the results of a preliminary study of a typical data center radio environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada ao Instituto Politécnico do Porto para obtenção do Grau de Mestre em Gestão das Organizações, Ramo Gestão de Empresas Orientada por: Profª Doutora Maria Alexandra Pacheco Ribeiro da Costa Esta dissertação inclui as críticas e sugestões feitas pelo Júri.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho enquadra-se na temática de segurança contra incêndio em edifícios e consiste num estudo de caso de projeto de deteção e extinção de incêndio num Data Center. Os objetivos deste trabalho resumem-se à realização de um estudo sobre o estado da arte da extinção e deteção automática de incêndio, ao desenvolvimento de uma ferramenta de software de apoio a projetos de extinção por agentes gasosos, como também à realização de um estudo e uma análise da proteção contra incêndios em Data Centers. Por último foi efetuado um estudo de caso. São abordados os conceitos de fogo e de incêndio, em que um estudo teórico à temática foi desenvolvido, descrevendo de que forma pode o fogo ser originado e respetivas consequências. Os regulamentos nacionais relativos à Segurança Contra Incêndios em Edifícios (SCIE) são igualmente abordados, com especial foco nos Sistemas Automáticos de Deteção de Incêndio (SADI) e nos Sistemas Automáticos de Extinção de Incêndio (SAEI), as normas nacionais e internacionais relativas a esta temática também são mencionadas. Pelo facto de serem muito relevantes para o desenvolvimento deste trabalho, os sistemas de deteção de incêndio são exaustivamente abordados, mencionando características de equipamentos de deteção, técnicas mais utilizadas como também quais os aspetos a ter em consideração no dimensionamento de um SADI. Quanto aos meios de extinção de incêndio foram mencionados quais os mais utilizados atualmente, as suas vantagens e a que tipo de fogo se aplicam, com especial destaque para os SAEI com utilização de gases inertes, em que foi descrito como deve ser dimensionado um sistema deste tipo. Foi também efetuada a caracterização dos Data Centers para que seja possível entender quais as suas funcionalidades, a importância da sua existência e os aspetos gerais de uma proteção contra incêndio nestas instalações. Por último, um estudo de caso foi desenvolvido, um SADI foi projetado juntamente com um SAEI que utiliza azoto como gás de extinção. As escolhas e os sistemas escolhidos foram devidamente justificados, tendo em conta os regulamentos e normas em vigor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, data centers are large energy consumers and the trend for next years is expected to increase further, considering the growth in the order of cloud services. A large portion of this power consumption is due to the control of physical parameters of the data center (such as temperature and humidity). However, these physical parameters are tightly coupled with computations, and even more so in upcoming data centers, where the location of workloads can vary substantially due, for example, to workloads being moved in the cloud infrastructure hosted in the data center. Therefore, managing the physical and compute infrastructure of a large data center is an embodiment of a Cyber-Physical System (CPS). In this paper, we describe a data collection and distribution architecture that enables gathering physical parameters of a large data center at a very high temporal and spatial resolution of the sensor measurements. We think this is an important characteristic to enable more accurate heat-flow models of the data center and with them, find opportunities to optimize energy consumptions. Having a high-resolution picture of the data center conditions, also enables minimizing local hot-spots, perform more accurate predictive maintenance (failures in all infrastructure equipments can be more promptly detected) and more accurate billing. We detail this architecture and define the structure of the underlying messaging system that is used to collect and distribute the data. Finally, we show the results of a preliminary study of a typical data center radio environment.