20 resultados para Comfort

em Instituto Politécnico do Porto, Portugal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this abstract is presented an energy management system included in a SCADA system existent in a intelligent home. The system control the home energy resources according to the players definitions (electricity consumption and comfort levels), the electricity prices variation in real time mode and the DR events proposed by the aggregators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho surgiu do âmbito da Tese de Dissertação do Mestrado em Energias Sustentáveis do Instituto Superior de Engenharia do Porto, tendo o acompanhamento dos orientadores da empresa Laboratório Ecotermolab do Instituto de Soldadura e Qualidade e do Instituto Superior de Engenharia do Porto, de forma a garantir a linha traçada indo de acordo aos objectivos propostos. A presente tese abordou o estudo do impacto da influência do ar novo na climatização de edifícios, tendo como base de apoio à análise a simulação dinâmica do edifício em condições reais num programa adequado, acreditado pela norma ASHRAE 140-2004. Este trabalho pretendeu evidenciar qual o impacto da influência do ar novo na climatização de um edifício com a conjugação de vários factores, tais como, ocupação, actividades e padrões de utilização (horários), iluminação e equipamentos, estudando ainda a possibilidade do sistema funcionar em regime de “Free-Cooling”. O princípio partiu fundamentalmente por determinar até que ponto se pode climatizar recorrendo único e exclusivamente à introdução de ar novo em regime de “Free-Cooling”, através de um sistema tudo-ar de Volume de Ar Variável - VAV, sem o apoio de qualquer outro sistema de climatização auxiliar localizado no espaço, respeitando os caudais mínimos impostos pelo RSECE (Decreto-Lei 79/2006). Numa primeira fase foram identificados todos os dados relativos à determinação das cargas térmicas do edifício, tendo em conta todos os factores e contributos alusivos ao valor da carga térmica, tais como a transmissão de calor e seus constituintes, a iluminação, a ventilação, o uso de equipamentos e os níveis de ocupação. Consequentemente foram elaboradas diversas simulações dinâmicas com o recurso ao programa EnergyPlus integrado no DesignBuilder, conjugando variáveis desde as envolventes à própria arquitectura, perfis de utilização ocupacional, equipamentos e taxas de renovação de ar nos diferentes espaços do edifício em estudo. Obtiveram-se vários modelos de forma a promover um estudo comparativo e aprofundado que permitisse determinar o impacto do ar novo na climatização do edifício, perspectivando a capacidade funcional do sistema funcionar em regime de “Free-Cooling”. Deste modo, a análise e comparação dos dados obtidos permitiram chegar às seguintes conclusões: Tendo em consideração que para necessidades de arrefecimento bastante elevadas, o “Free-Cooling” diurno revelou-se pouco eficaz ou quase nulo, para o tipo de clima verificado em Portugal, pois o diferencial de temperatura existente entre o exterior e o interior não é suficiente de modo a tornar possível a remoção das cargas de forma a baixar a temperatura interior para o intervalo de conforto. Em relação ao “Free-Cooling” em horário nocturno ou pós-laboral, este revelou-se bem mais eficiente. Obtiveram-se prestações muito interessantes sobretudo durante as estações de aquecimento e meia-estação, tendo em consideração o facto de existir necessidades de arrefecimento mesmo durante a estação de aquecimento. Referente à ventilação nocturna, isto é, em períodos de madrugada e fecho do edifício, concluiu-se que tal contribui para um abaixamento do calor acumulado durante o dia nos materiais construtivos do edifício e que é libertado ou restituído posteriormente para os espaços em períodos mais tardios. De entre as seguintes variáveis, aumento de caudal de ar novo insuflado e o diferencial de temperatura existente entre o ar exterior e interior, ficou demonstrado que este último teria maior peso contributivo na remoção do calor. Por fim, é ponto assente que de um modo geral, um sistema de climatização será sempre indispensável devido a cargas internas elevadas, requisitos interiores de temperatura e humidade, sendo no entanto aconselhado o “Free- Cooling” como um opção viável a incorporar na solução de climatização, de forma a promover o arrefecimento natural, a redução do consumo energético e a introdução activa de ar novo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Qualidade do Ar Interior (QAI) é um fator de grande preocupação. A importância de manter um ambiente salubre é mais acentuada em estabelecimentos escolares (EE), tendo em conta, que no interior destes permanecem crianças durante um elevado período de tempo. É fundamental garantir uma boa QAI nos edifícios escolares, de forma a salvaguardar a saúde, o bem-estar e o conforto dos ocupantes, bem como, não comprometer o seu desempenho escolar. Recentemente, foram construídos novos edifícios escolares e alguns dos existentes foram alvo de obras de remodelação. Contudo, a crescente tendência em construir edifícios cada vez mais herméticos, com vista à diminuição dos gastos de energia, origina problemas como a reduzida ventilação dos espaços. Vários estudos têm demonstrado a influência das atividades de limpeza na QAI. No entanto, verifica-se que na maioria das escolas não existem ainda procedimentos de limpeza padronizados. A falta de instruções de trabalho e a ausência de formação às assistentes operacionais pode comprometer a eficácia dos procedimentos de higienização, o que poderá ter influência na QAI dos espaços. Este estudo teve como principal objetivo avaliar a QAI em escolas básicas de 1.º ciclo. Foram contemplados no estudo fatores como a tipologia do edifício, a ocupação das salas e as atividades de limpeza. Procedeu-se à caracterização dos EE e à monitorização de parâmetros ambientais, como a temperatura do ar, a humidade relativa, a velocidade do ar, o dióxido de carbono, o monóxido de carbono, as partículas, os microrganismos mesófilos totais e os fungos. Estes parâmetros foram avaliados nas salas com ocupação, sem ocupação e durante a implementação de um plano de higienização. A ventilação inadequada parece ser o fator que mais condiciona a QAI das salas de aula avaliadas. Registaram-se elevadas concentrações de dióxido de carbono e de microrganismos mesófilos totais, que parecem estar relacionados com a permanência dos ocupantes nos locais e com a falta de ventilação adequada dos espaços. A concentração de dióxido de carbono foi mais elevada em edifícios recentes. Os picos elevados na concentração de partículas parecem estar associados com as atividades dos ocupantes. Obtiveram-se concentrações menores de fungos e de microrganismos mesófilos totais ao longo da implementação do plano de higienização, o que poderá significar que os procedimentos de limpeza contribuem para reduzir os níveis de contaminação dos espaços interiores. No entanto, tendo em conta, que a concentração de microrganismos mesófilos totais permaneceu elevada, as operações de limpeza parecem não ser suficientes para garantir uma boa QAI. O aumento da ventilação dos espaços poderia contribuir significativamente para a melhoria da QAI dos espaços avaliados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Em consequência da elevada permanência das pessoas em espaços interiores de edifícios, surge actualmente uma maior preocupação com o conforto térmico e qualidade do ar no seu interior. Apesar da grande evolução tecnológica dos sistemas de conservação de energia térmica e controle da qualidade do ar interior (QAI) na construção, os edifícios existentes acabam por não acompanhar essa evolução, apresentando um comportamento térmico e higrométrico que por vezes podem comprometer quer o conforto, quer a saúde e actividades dos seus utilizadores. Nos estabelecimentos de ensino, o comportamento termo-higrométrico assume um papel importante face à permanência diária de um grande número de crianças e jovens no seu interior. Com este estudo pretende-se caracterizar a qualidade do ambiente no interior de oito escolas, através de uma análise aos principais parâmetros de natureza higrotérmica de oito salas de aulas, tais como: a temperatura (ambiente e superficial), a humidade relativa (do ambiente e da superfície da envolvente exterior opaca), bem como o nível de escoamento do ar interior. Neste trabalho são apresentados os resultados das medições efectuadas em oito salas de aula que permitiram a comparação de características termo-higrométricas entre as respectivas escolas. É ainda apresentada a estimativa do nível de conforto térmico face às condições ambientais registadas, bem como a análise do risco de ocorrência de condensações interiores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A civilização contemporânea, pelas suas características, é muito exigente em tudo o que diz respeito ao conforto dos edifícios, para trabalho ou habitação, e à necessidade de economizar e racionalizar o uso de energia. A térmica dos edifícios assume, por isso, uma importância acrescida na atividade profissional e no ensino. Para se conduzir ao aperfeiçoamento de soluções na envolvente dos edifícios a este nível, o trabalho aqui realizado centrou-se no estudo do funcionamento da termografia de infravermelhos e da importância da sua utilização na inspeção térmica de edifícios. Descoberta no início do século XIX e desenvolvendo os primeiros sistemas operativos desde a 1ª Guerra Mundial, a fim de determinar heterogeneidades de temperatura superficial, esta técnica não destrutiva permite identificar anomalias que não são visualizadas a olho nu. Com a análise dessas variações de temperatura é possível conhecer os problemas e a localização de irregularidades. Este trabalho baseia-se substancialmente no estudo de edifícios. A análise realizada teve como finalidade executar inspeções termográficas – visuais, com duas abordagens. Por um lado, avaliar salas pertencentes a estabelecimentos de ensino secundário, reabilitadas e não reabilitadas, todas construídas entre as décadas de 60 e 90, com o intuito de diagnosticar patologias construtivas, recorrendo à termografia. Por outro, a análise de edifícios de habitação, com a intenção de avaliar a necessidade de um equipamento complementar às inspeções termográficas – o sistema de porta ventiladora. As inspeções foram regidas pelas diretrizes da norma europeia EN 13187. A termografia é uma técnica importante na realização de ensaios in situ que requerem rapidez de execução, aliada à vantagem de disponibilizar resultados em tempo real, permitindo assim uma primeira análise das leituras no local. A inspeção termográfica complementada com o sistema de porta ventiladora permitiu, também, revelar a importância da necessidade de meios auxiliares em certos casos. A conjugação destas diferentes técnicas permite reduzir a subjetividade da análise in situ e aumentar a fiabilidade do diagnóstico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação descreve o estudo, concepção e desenvolvimento de uma aplicação baseada no sistema operativo Windows 8 que interage com um sistema domótico KNX, permitindo ao utilizador controlar a sua instalação domótica. Esta proposta, que combina a área de integração/instalação de sistemas domóticos e a de desenvolvimento de aplicações para Windows 8 e Windows 8 Phone, constitui um desafio particularmente interessante para quem tem experiência profissional nas duas áreas. A domótica surgiu na década de 70 como uma aplicação da eletrónica e das tecnologias da informação às instalações residenciais, comerciais e industriais. Esta nova área desencadeou uma revolução, não só, ao nível da produção e comercialização, mas, também, do ponto de vista do utilizador, ao promover a comodidade, segurança, personalização e o controlo de pessoas e bens. Os smartphones e tablets vieram permitir que o desenvolvimento de aplicações móveis de interacção com os sistemas domóticos. Ao longo desta dissertação são descritas e analisadas as múltiplas áreas de intervenção da domótica assim como as diferentes tecnologias de aplicação e mercados. Também são analisados os sistemas operativos que existentes, as respetivas cotas de mercado e os tipos de dispositivos disponíveis. Por último, a aplicação foi concebida, implementada e testada para verificar a correcta interacção com o sistema domótico KNX e as funcionalidades de controlo da instalação domótica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In future power systems, in the smart grid and microgrids operation paradigms, consumers can be seen as an energy resource with decentralized and autonomous decisions in the energy management. It is expected that each consumer will manage not only the loads, but also small generation units, heating systems, storage systems, and electric vehicles. Each consumer can participate in different demand response events promoted by system operators or aggregation entities. This paper proposes an innovative method to manage the appliances on a house during a demand response event. The main contribution of this work is to include time constraints in resources management, and the context evaluation in order to ensure the required comfort levels. The dynamic resources management methodology allows a better resources’ management in a demand response event, mainly the ones of long duration, by changing the priorities of loads during the event. A case study with two scenarios is presented considering a demand response with 30 min duration, and another with 240 min (4 h). In both simulations, the demand response event proposes the power consumption reduction during the event. A total of 18 loads are used, including real and virtual ones, controlled by the presented house management system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A reabilitação é uma intervenção que confere ao edifício uma qualidade superior à que possuía aquando da sua construção. Desta forma, e com a entrada em vigor em final de 2013 da nova legislação referente à certificação energética dos edifícios, surge novamente o interesse na temática de reabilitar energeticamente o parque habitacional. Esta nova legislação aparece na sequencia das novas exigências da Comissão Europeia e do Parlamento Europeu face às alterações climáticas e consequentemente, em relação à eficiência energética. A reabilitação energética de edifícios, visa principalmente a melhoria das condições de conforto térmico, a redução dos consumos energéticos com aquecimento, arrefecimento e as águas quentes sanitárias. Tais melhorias são alcançáveis com intervenções que se foquem na envolvente dos edifícios, com a aplicação de sistemas de alta eficiência para o aquecimento, arrefecimento, iluminação e águas quentes sanitárias e com a integração de fontes de energias renováveis. Assim é possível alcançar edifícios com necessidades nulas ou quase nulas de energia, tal como exigem as metas impostas a nível europeu.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of demand response programs enables the adequate use of resources of small and medium players, bringing high benefits to the smart grid, and increasing its efficiency. One of the difficulties to proceed with this paradigm is the lack of intelligence in the management of small and medium size players. In order to make demand response programs a feasible solution, it is essential that small and medium players have an efficient energy management and a fair optimization mechanism to decrease the consumption without heavy loss of comfort, making it acceptable for the users. This paper addresses the application of real-time pricing in a house that uses an intelligent optimization module involving artificial neural networks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recent changes on power systems paradigm requires the active participation of small and medium players in energy management. With an electricity price fluctuation these players must manage the consumption. Lowering costs and ensuring adequate user comfort levels. Demand response can improve the power system management and bring benefits for the small and medium players. The work presented in this paper, which is developed aiming the smart grid context, can also be used in the current power system paradigm. The proposed system is the combination of several fields of research, namely multi-agent systems and artificial neural networks. This system is physically implemented in our laboratories and it is used daily by researchers. The physical implementation gives the system an improvement in the proof of concept, distancing itself from the conventional systems. This paper presents a case study illustrating the simulation of real-time pricing in a laboratory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As fachadas são um elemento da envolvente que faz a interface entre o ambiente exterior e o interior. Do conjunto das suas características mais relevantes, existe uma, cuja importância tem vindo a aumentar devido à conjuntura ambiental e económica atual: o desempenho energético. Assim, é importante analisar as características do comportamento térmico dos elementos da fachada, com base na respetiva regulamentação em vigor (REH – D.L. n.º 118/2013 de 20 de Agosto) e analisar o contributo da sua eventual reabilitação para uma melhor qualidade térmica da fachada e por consequente uma melhor qualidade de conforto dos utentes do edificio, não desprezando o aspeto arquitetónico do mesmo. Esta monografia baseia-se na análise de casos práticos de diferentes soluções construtivas e avaliação das vantagens e desvantagens dos sistemas propostos, conferindo a possibilidade de optar pelo sistema mais eficaz de acordo com as necessidades exigidas. Assim, e com base no principal objetivo, que é o de melhorar o desempenho térmico das fachadas recorrendo à reabilitação, o enfoque é sobre a redução do consumo energético dos edificios, nomeadamente através do contributo térmico dos elementos das fachadas para a redução das necessidades energéticas por climatização.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A utilização pouco eficiente da energia representa um elevado encargo para qualquer país, seja do ponto de vista económico, social ou ambiental. Em Portugal a iluminação pública tem um importante peso nas despesas correntes dos municípios. Deste modo, torna-se imperativo agir de modo a aumentar a sustentabilidade energética e diminuir os gastos com a iluminação pública. Os municípios precisam de encontrar soluções que permitam reduzir os consumos, mantendo níveis de segurança e conforto necessários às populações. Neste sentido, este trabalho propõe-se estudar esta problemática, apresentando soluções, de modo a obter-se uma maior eficiência energética desta para as instalações e, consequentemente, conduzir a uma diminuição das emissões de CO2 durante o período de utilização das mesmas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho aborda a temática da eficiência energética em sistemas de iluminação pública. A principal motivação prende-se com o peso significativo que a parcela energética destes sistemas ocupa na economia mundial. O uso eficiente de energia é uma crescente preocupação devido à diminuição de recursos, às consequências climáticas cada vez mais marcadas e ao elevado custo da energia, representando ainda um papel fundamental ao nível económico e de competitividade. A Iluminação Pública (IP) representa um peso importante nas despesas correntes dos municípios. É assim importante encontrar uma solução que permita manter níveis de segurança e conforto necessários às populações e que proporcione uma redução substancial do peso da IP nas despesas municipais. Neste sentido, este trabalho propõe-se estudar esta problemática, apresentando uma sistematização de soluções eficientes, quer a nível de lâmpadas e luminárias como também ao nível de tecnologias que auxiliem e complementem a eficiência de uma instalação de iluminação pública. A dissertação está dividida em duas partes. A primeira parte sistematiza os consumos verificados em Portugal, a vários níveis (consumo de energia elétrica, evolução do consumo energético de iluminação pública, etc.) abordando as políticas de eficiência energética, e são descritos alguns procedimentos que possibilitam a poupança energética na iluminação pública, aliada a instalações eficientes. A segunda parte da dissertação contempla o estudo de um caso prático cujo objetivo é propor soluções técnicas que permitam melhorar a eficiência energética na iluminação pública de Esposende, face à situação atual do concelho. Serão propostas várias soluções, tais como luminárias LED, balastros electrónicos reguláveis, lâmpadas de menor consumo e até mesmo o uso da telegestão.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Por um lado vivemos numa sociedade cujos padrões de conforto são cada vez mais exigentes, por outro encontramo-nos numa era pautada por um certo declínio económico, social e também ambiental. Não se assumindo uma estratégia que limite ou diminua essas condições de conforto resta-nos atuar de forma a que os recursos utilizados para garantir esse mesmo conforto sejam utilizados da melhor forma possível. O setor dos edifícios é responsável por uma grande parcela de consumo de energia na sociedade atual, sendo que os sistemas de climatização que dele fazem parte, apresentam.se na maioria dos casos como os grandes consumidores de energia. Nesse sentido têm sido feitos esforços enormes no sentido de encontrar soluções que garantam a eficiência energética destes sistemas. O Variador Eletrónico de Velocidade apresenta-se como uma das soluções amplamente difundidas, na vertente do controle de processos e economia de energia. A sua aplicação em sistema de climatização é mais um desses casos. Nesse sentido, numa primeira parte é feito o estudo das características e funcionamento dos Variadores de Velocidade, Sistemas de Climatização e sua aplicação conjunta. Em seguida é realizada uma aplicação informática que pretende demonstrar a economia de energia garantida por aplicação de um Variador de Velocidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dado o panorama de conservação de energia a nível nacional e mundial, torna-se hoje em dia muito importante, que seja possível controlar e estimar o consumo energético nos edifícios. Assim, atendendo à actual problemática energética e ao crescente consumo energético nos edifícios, é importante parametrizar, avaliar e comparar este consumo. Neste sentido, nas últimas décadas, têm sido efectuados desenvolvimentos técnicos, quer ao nível do equipamento de campo para efectuar monitorização e medição, quer ao nível da simulação dinâmica de edifícios. Com esta dissertação de mestrado, pretendeu-se efectuar a simulação dinâmica de um edifício escolar existente a funcionar em pleno, e efectuar uma análise de sensibilidade relativamente ao grau de variação dos resultados obtidos através da aplicação de dois programas de cálculo térmico e energético. Foram utilizados, o programa VE-Pro da IES (Integrated Environmental Solutions) e o programa Trace 700 da TRANE. Ambos os programas foram parametrizados com os mesmos dados de entrada, tendo em atenção as opções de simulação disponibilizadas por ambos. Posteriormente, utilizaram-se os dados retirados da simulação para calcular a classificação energética no âmbito do sistema de certificação energética (SCE), através de uma folha de cálculo desenvolvida para o efeito. Foram ainda consideradas várias soluções de eficiência energética para o edifício, com vista a poupanças reais de energia, tendo sempre atenção ao conforto térmico dos ocupantes. Dessas medidas fazem parte, medidas relacionadas com a iluminação, como a substituição da iluminação existente por luminárias do tipo LED (Light Emitting Diode), soluções de energias renováveis, como a instalação de colectores solares para aquecimento das águas quentes sanitárias, e painéis fotovoltaicos para produção de energia, bem como medidas ligadas aos equipamentos de climatização. Posteriormente, recalculou-se a classificação energética afectada das melhorias. Os resultados obtidos nas duas simulações foram analisados sob o ponto de vista do aquecimento, arrefecimento, ventilação, iluminação e equipamentos eléctricos. A comparação das duas simulações para cada parâmetro acima referido, apresentaram variações inferiores a 5%. O desvio maior verificou-se na ventilação, com o valor de aproximadamente 4,9%. Transpondo estes resultados para o cálculo do IEE (Índice de Eficiência Energética), verificou-se um desvio inferior a 2%.