5 resultados para Coil

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to determine, for Newtonian and non-Newtonian fluids, the friction factor (fc) with simultaneous heat transfer, at constant wall temperature as boundary condition, in fully developed laminar flow inside a vertical helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w). The non-Newtonian fluids were aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations of 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations of 0.1% and 0.2% (w/w). According to the rheological study done, the polymer solutions had shear-thinning behavior and different values of viscoelasticity. The helical coil used has an internal diameter, curvature ratio, length and pitch, respectively: 0.00483 m, 0.0263, 5.0 m and 11.34 mm. It was concluded that the friction factors, with simultaneous heat transfer, for Newtonian fluids can be calculated using expressions from literature for isothermal flows. The friction factors for CMC and XG solutions are similar to those for Newtonian fluids when the Dean number, based in a generalized Reynolds number, is less than 80. For Dean numbers higher than 80, the friction factors of the CMC solutions are lower those of the XG solutions and of the Newtonian fluids. In this range the friction factors decrease with the increase of the viscometric component of the solution and increase for increasing elastic component. The change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, is in accordance with the study of Ali [4]. There is a change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, which is in according to previous studies. The data also showed that the use of the bulk temperature or of the film temperature to calculate the physical properties of the fluid has a residual effect in the friction factor values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to obtain, for Newtonian and non-Newtonian fluids, heat transfer coefficients, at constant wall temperature as boundary condition, in fully developed laminar flow inside a helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w) and the non-Newtonian fluids aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations 0.1%, 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations 0.1% and 0.2% (w/w). According to the rheological study performed, the polymer solutions had shear thinning behavior and different values of elasticity. The helical coil used has internal diameter, curvature ratio, length and pitch, respectively: 0.004575 m, 0.0263, 5.0 m and 11.34 mm. The Nusselt numbers for the CMC solutions are, on average, slightly higher than those for Newtonian fluids, for identical Prandtl and generalized Dean numbers. As outcome, the viscous component of the shear thinning polymer tends to potentiate the mixing effect of the Dean cells. The Nusselt numbers of the XG solutions are significant lower than those of the Newtonian solutions, for identical Prandtl and generalized Dean numbers. Therefore, the elastic component of the polymer tends to diminish the mixing effect of the Dean cells. A global correlation, for Nusselt number as a function of Péclet, generalized Dean and Weissenberg numbers for all Newtonian and non-Newtonian solutions studied, is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor Air 2016 - The 14th International Conference Indoor Air Quality and Climate

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to select appropriate oxidizing agents, pH, and concentration ratios of reagents, on the basis of their effect on the stability of the colored complex. Conditions selected as a result of these trials were implemented in a flow-injection analytical system in which the influence of injection volume, flow rate, and reaction- coil length, was evaluated. Under the optimum conditions the total amount of polyphenols, expressed as gallic acid, could be determined within a concentration range of 36 to 544 mg L–1, and with a sensitivity of 344 L mol–1 cm–1 and an RSD <1.1%. The reproducibility of analytical readings was indicative of standard deviations <2%. Interference from sugars, tartaric acid, ascorbic acid, methanol, ammonium sulfate, and potassium chloride was negligible. The proposed system was applied to the determination of total polyphenols in red wines, and enabled analysis of approximately 55 samples h–1. Results were usually precise and accurate; the RSD was <3.9% and relative errors, by the Folin–Ciocalteu method, <5.1%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dissertação foi realizada em ambiente industrial, mais precisamente na empresa Monteiro, Ribas – Embalagens Flexíveis, S.A.. Esta empresa dedica-se à impressão e laminagem de filmes, assim como à confeção de sacos. Os seus produtos são direcionados na sua maioria para a indústria alimentar, exportando mais de 50% da sua produção, e dizem respeito a complexos (dois ou mais filmes unidos pela presença de um adesivo) que podem possuir impressão ou não. Estes complexos podem ser enviados para o cliente em bobina ou já em saco. Os objetivos propostos pela empresa diziam respeito a estudos relacionados com a força de laminagem dos complexos, com o coeficiente de atrito dos mesmos e com a identificação dos espetros dos componentes dos adesivos, assim como o estudo do processo de reticulação dos mesmos por espetrofotometria de Infravermelho. Relativamente aos resultados obtidos verificou-se que tanto a tinta como os metalizados influenciam negativamente a força de laminagem. Por sua vez o coeficiente de atrito é afetado por vários fatores. Através dos ensaios experimentais verificou-se que o adesivo, a tinta e o verniz mate favorecem o aumento do valor do COF. Além disso, nos complexos em que se utilizaram filmes de polietileno de maior espessura obtiveram-se valores de COF mais baixos, e no que diz respeito à temperatura e à tensão de enrolamento, verificou-se que valores mais elevados e muito baixos da primeira traduzem-se num aumento do valor do COF e uma tensão de enrolamento maior também tem o mesmo efeito. Relativamente ao tipo de filme impresso, substratos com maior energia superficial atraem mais o agente de deslizamento (slip). Por último, não se conseguiu perceber qual o tipo de adesivo (com ou sem solvente) que tem maior impacto no COF uma vez que em 55% dos casos o valor do COF é superior nas amostras que foram complexadas com adesivo sem solvente e em 45% o COF era superior nas amostras complexadas com adesivo base solvente. No que diz respeito aos espetros obtidos verificou-se que a reticulação dos adesivos é identificada pela diminuição da extensão do pico correspondente à ligação N=C=O.