15 resultados para Cervical length measurement
em Instituto Politécnico do Porto, Portugal
Resumo:
The interlaminar fracture toughness in pure mode II (GIIc) of a Carbon-Fibre Reinforced Plastic (CFRP) composite is characterized experimentally and numerically in this work, using the End-Notched Flexure (ENF) fracture characterization test. The value of GIIc was extracted by a new data reduction scheme avoiding the crack length measurement, named Compliance-Based Beam Method (CBBM). This method eliminates the crack measurement errors, which can be non-negligible, and reflect on the accuracy of the fracture energy calculations. Moreover, it accounts for the Fracture Process Zone (FPZ) effects. A numerical study using the Finite Element Method (FEM) and a triangular cohesive damage model, implemented within interface finite elements and based on the indirect use of Fracture Mechanics, was performed to evaluate the suitability of the CBBM to obtain GIIc. This was performed comparing the input values of GIIc in the numerical models with the ones resulting from the application of the CBBM to the numerical load-displacement (P-) curve. In this numerical study, the Compliance Calibration Method (CCM) was also used to extract GIIc, for comparison purposes.
Resumo:
Ao longo destes últimos anos as ligações adesivas têm vindo a verificar um aumento progressivo em aplicações estruturais em detrimento das ligações mecânicas convencionais. Esta alteração de paradigma deve-se às vantagens que as juntas adesivas possuem relativamente aos outros métodos de ligação. A mecânica da fratura e os Modelos de Dano Coesivo (MDC) são critérios comuns para prever a resistência em juntas adesivas e usam como parâmetros fundamentais as taxas de libertação de energia. Pelo facto do ensaio 4-Point End Notched Flexure (4-ENF), aplicado em juntas adesivas, ainda estar pouco estudado é de grande relevância um estudo acerca da sua viabilidade para a determinação da taxa crítica de libertação de energia de deformação ao corte (GIIc). Esta dissertação tem como objetivo principal efetuar uma comparação entre os métodos End- Notched Flexure (ENF) e 4-ENF na determinação de GIIc em juntas adesivas. Para tal foram utilizados 3 adesivos: Araldite® AV138, Araldite® 2015 e SikaForce® 7752. O trabalho experimental passou pela conceção e fabrico de uma ferramenta para realização do ensaio 4-ENF, seguindo-se o fabrico e a preparação dos provetes para os ensaios. Pelo facto do ensaio 4-ENF ainda se encontrar pouco divulgado em juntas adesivas, e não se encontrar normalizado, uma parte importante do trabalho passou pela pesquisa e análise em trabalhos de investigação e artigos científicos. A análise dos resultados foi realizada por comparação direta dos valores de GIIc com os resultados obtidos no ensaio ENF, sendo realizada por série de adesivo, através da comparação das curvas P-δ e curvas-R. Como resultado verificou-se que o ensaio 4-ENF em ligações adesivas não é o mais versátil para a determinação do valor de GIIc, e que apenas um método de obtenção de GIIc é viável. Este método é baseado na medição do comprimento de fenda (a). Ficou evidenciado que o ensaio ENF, devido a ser um ensaio normalizado, por apresentar um setup mais simples e por apresentar uma maior disponibilidade de métodos para a determinação do valor de GIIc, é o mais recomendado. Conclui-se assim que o ensaio 4-ENF, embora sendo uma alternativa ao ensaio ENF, tem aplicação mais limitada.
Resumo:
A dor cervical é cada vez mais um problema comum e incapacitante nos países industrializados. O objectivo do estudo foi determinar a prevalência de dor cervical nos últimos seis meses, intensidade da dor e incapacidade funcional em indivíduos com dor cervical. O estudo do tipo observacional, descritivo e transversal. Amostra constituída por alunos, docentes, administrativos e auxiliares da ESTSP (n=285). Os instrumentos utilizados foram: questionário de caracterização da amostra, escala visual analógica e Neck Disability Index. A prevalência de dor cervical foi elevada e a dor classificada como moderada. A incapacidade funcional variou entre ligeira e moderada.
Resumo:
Introdução: Não existe um consenso quanto ao melhor tratamento para a radiculopatia cervical pois existe uma grande variedade de manifestações clínicas e opções terapêuticas, mas a sua selecção vai depender do caso particular do utente, sugerindo assim uma correcta avaliação do Fisioterapeuta. Objectivo: Este estudo pretende descrever e avaliar a efectividade de um programa de Fisioterapia num caso de radiculopatia cervical, na dor, funcionalidade e percepção da qualidade de vida. Participantes e Métodos: Estudo observacional descritivo tipo estudo de caso de um utente de 56 anos de idade, com radiculopatia cervical. Para a avaliação foram utilizados testes ortopédicos, a escala visual analógica e os questionários de incapacidade funcional da cervical e do membro superior bem como da percepção da qualidade de vida. Estes questionários foram aplicados em 3 momentos, antes da intervenção, no final e após 6 semanas e os restantes instrumentos foram utilizados em diversos momentos ao longo da intervenção. Esta foi efectuada duas vezes por semana, ao longo de 10 semanas recorrendo a técnicas de terapia manual, exercícios de controlo motor e educação do utente. Resultados: Verificou-se que a dor na cervical passou de 6,5 para 2/10 EVA e no cotovelo direito de 7,3 para 2/10. A resposta ao questionário de incapacidade funcional na cervical variou de 40% no primeiro momento para 11,1% no segundo, o da incapacidade funcional do membro superior variou de 63,6% para 33,5% e o questionário da percepção da qualidade de vida variou de 55,01 para 68,69. Seis semanas após a intervenção, todos estes resultados se mantinham praticamente inalterados. Conclusão: Este caso permitiu demonstrar o processo de raciocínio clínico efectuado ao longo de dez semanas de intervenção em que se utilizou uma abordagem centrada no utente, baseada na evidência científica e na experiência clínica anterior. Os resultados alcançados foram de encontro às expectativas iniciais e parecem evidenciar que, neste caso, o programa de fisioterapia teve efeitos positivos na dor, funcionalidade e percepção da qualidade de vida.
Resumo:
Caso clínico: Este estudo observacional descritivo - tipo estudo de caso, tem como amostra uma senhora de 36 anos com dor cervical superior esquerda e de cabeça. Após uma avaliação inicial, a paciente foi submetida a três aplicações da técnica de inibição dos músculos sub-occipitais durante uma semana em dias alternados, com o objetivo de quantificar o seu efeito nas amplitudes articulares cervicais, na dor e na funcionalidade. Para o efeito foram utilizados como instrumentos o Cervical Range of Motion Instrument, a Escala Visual Analógica e o Índice de Incapacidade relacionada com a Cervical. A paciente foi reavaliada em três momentos distintos (1’ após a primeira aplicação da técnica e oito e quinze dias depois). O resultado imediato da técnica foi de um ligeiro aumento nalgumas amplitudes articulares mas noutras ocorreu uma diminuição dos seus valores. Após 8 e 15 dias houve um aumento de todas as amplitudes articulares cervicais à exceção da inclinação e da rotação esquerda que diminuíram ligeiramente em relação à avaliação inicial e da extensão que manteve a mesma amplitude articular. Quanto à sintomatologia dolorosa foi eliminada por completo e a pontuação da funcionalidade passou de 18 para zero logo após a primeira intervenção. A aplicação desta técnica, nesta paciente, aumentou as amplitudes articulares cervicais, eliminou a dor cervical e de cabeça e melhorou a funcionalidade.
Resumo:
A novel biomimetic sensor for the potentiometric transduction of oxytetracycline is presented. The artificial host was imprinted in methacrylic acid and/or acrylamide based polymers. Different amounts of molecularly imprinted and non-imprinted polymers were dispersed in different plasticizing solvents and entrapped in a poly(vinyl chloride) matrix. Only molecularly imprinted based sensors allowed a potentiometric transduction, suggesting the existence of host–guest interactions. These sensors exhibited a near-Nernstian response in steady state evaluations; slopes and detection limits ranged 42–63 mV/decade and 2.5–31.3 µg/mL, respectively. Sensors were independent from the pH of test solutions within 2–5. Good selectivity was observed towards glycine, ciprofloxacin, creatinine, acid nalidixic, sulfadiazine, cysteine, hydroxylamine and lactose. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ±0.7%), fast response, good sensitivity (65 mV/decade), wide linear range (5.0×10−5 to 1.0×10−2 mol/L), low detection limit (19.8 µg/mL), and a stable baseline for a 5×10−3M citrate buffer (pH 2.5) carrier. The sensors were successfully applied to the analysis of drugs and urine. This work confirms the possibility of using molecularly imprinted polymers as ionophores for organic ion recognition in potentiometric transduction.
Resumo:
Objective: The purpose of this study was to investigate effects of different manual techniques on cervical ranges of 17 motion and pressure pain sensitivity in subjects with latent trigger point of the upper trapezius muscle. 18 Methods: One hundred seventeen volunteers, with a unilateral latent trigger point on upper trapezius due to computer 19 work, were randomly divided into 5 groups: ischemic compression (IC) group (n = 24); passive stretching group (n = 20 23); muscle energy technique group (n = 23); and 2 control groups, wait-and-see group (n = 25) and placebo group 21 (n = 22). Cervical spine range of movement was measured using a cervical range of motion instrument as well as 22 pressure pain sensitivity by means of an algometer and a visual analog scale. Outcomes were assessed pretreatment, 23 immediately, and 24 hours after the intervention and 1 week later by a blind researcher. A 4 × 5 mixed repeated- 24 measures analysis of variance was used to examine the effects of the intervention and Cohen d coefficient was used. 25 Results: A group-by-time interaction was detected in all variables (P b .01), except contralateral rotation. The 26 immediate effect sizes of the contralateral flexion, ipsilateral rotation, and pressure pain threshold were large for 3 27 experimental groups. Nevertheless, after 24 hours and 1 week, only IC group maintained the effect size. 28 Conclusions: Manual techniques on upper trapezius with latent trigger point seemed to improve the cervical range of 29 motion and the pressure pain sensitivity. These effects persist after 1 week in the IC group. (J Manipulative Physiol 301 Ther 2013;xx:1-10)
Resumo:
This manuscript analyses the data generated by a Zero Length Column (ZLC) diffusion experimental set-up, for 1,3 Di-isopropyl benzene in a 100% alumina matrix with variable particle size. The time evolution of the phenomena resembles those of fractional order systems, namely those with a fast initial transient followed by long and slow tails. The experimental measurements are best fitted with the Harris model revealing a power law behavior.
Resumo:
Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng m−3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng m−3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68–200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.
Resumo:
This paper presents the results of an exploratory study on knowledge management in Portuguese organizations. The study was based on a survey sent to one hundred of the main Portuguese organizations, in order to know their current practices relating knowledge management systems (KMS) usage and intellectual capital (IC) measurement. With this study, we attempted to understand what are the main tools used to support KM processes and activities in the organizations, and what metrics are pointed by organizations to measure their knowledge assets.
Resumo:
Mestrado em Engenharia Mecânica
Resumo:
A utilização de juntas adesivas em aplicações industriais tem vindo a aumentar, em detrimento dos métodos tradicionais tais como a soldadura, brasagem e ligações aparafusadas e rebitadas. Este facto deve-se às vantagens que estas oferecem, como o facto de serem mais leves, comportarem-se bem sob cargas cíclicas ou de fadiga, a ligação de materiais diferentes e menores concentrações de tensões. Para aumentar a confiança no projeto de estruturas adesivas, é importante conseguir prever com precisão a sua resistência mecânica e respetivas propriedades de fratura (taxa crítica de libertação de energia de deformação à tração, GIC, e corte, GIIC). Estas propriedades estão diretamente relacionadas com a Mecânica da Fratura e são estimadas através de uma análise energética. Para este efeito, distinguem-se três tipos de modelos: modelos que necessitam da medição do comprimento de fenda durante a propagação do dano, modelos que utilizam um comprimento de fenda equivalente e métodos baseados no integral J. Como na maioria dos casos as solicitações ocorrem em modo misto (combinação de tração com corte), é de grande importância a perceção da fratura nesta condições, nomeadamente das taxas de libertação de energia relativamente a diferentes critérios ou envelopes de fratura. Esta comparação permite, por exemplo, averiguar qual o melhor critério energético de rotura a utilizar em modelos numéricos baseados em Modelos de Dano Coesivo. Neste trabalho é realizado um estudo experimental utilizando o ensaio Single-Leg Bending (SLB) em provetes colados com três tipos de adesivos, de forma a estudar e comparar as suas propriedades de fratura. Para tal, são aplicados alguns modelos de redução da taxa de libertação de energia de deformação à tração, GI, e corte, GII, enquadrados nos modelos que necessitam da medição do comprimento de fenda e nos modelos que utilizam um comprimento de fenda equivalente. Numa fase posterior, procedeu-se à análise e comparação dos resultados adquiridos durante a fase experimental de GI e GII de cada adesivo. A discussão de resultados foi também feita através da análise dos valores obtidos em diversos envelopes de fratura, no sentido de averiguar qual o critério de rotura mais adequado a considerar para cada adesivo. Foi obtida uma concordância bastante boa entre métodos de determinação de GI e GII, com exceção do adesivo mais dúctil, para o qual o método baseado no comprimento de fenda equivalente apresentou resultados ligeiramente superiores.
Resumo:
The use of solid wastes and natural fibres to the production of innovative composites is now a matter of environmental need. A set of hybrid composites constituted of waste rubber particles and sugarcane bagasse fibres into a thermoset composite material are drilled to determine the effect of rubber particle addition and size, sugarcane fibre addition and length and fibre chemical treatment on damage extension and related mechanical properties. Damage extension is determined by enhanced radiography for further damage measurement – diameter and areas – and correlated with mechanical test results — bearing test. The results demonstrated significant effect of the rubber and fibre additions on mechanical properties of the composites.
Resumo:
Adhesive bonding is an excellent alternative to traditional joining techniques such as welding, mechanical fastening or riveting. However, there are many factors that have to be accounted for during joint design to accurately predict the joint strength. One of these is the adhesive layer thickness (tA). Most of the results are for epoxy structural adhesives, tailored to perform best with small values of tA, and these show that the lap joint strength decreases with increase of tA (the optimum joint strength is usually obtained with tA values between 0.1 and 0.2 mm). Recently, polyurethane adhesives were made available in the market, designed to perform with larger tA values, and whose fracture behaviour is still not studied. In this work, the effect of tA on the tensile fracture toughness (View the MathML source) of a bonded joint is studied, considering a novel high strength and ductile polyurethane adhesive for the automotive industry. This work consists on the fracture characterization of the bond by a conventional and the J-integral techniques, which accurately account for root rotation effects. An optical measurement method is used for the evaluation of crack tip opening (δn) and adherends rotation at the crack tip (θo) during the test, supported by a Matlab® sub-routine for the automated extraction of these parameters. As output of this work, fracture data is provided in traction for the selected adhesive, enabling the subsequent strength prediction of bonded joints.