6 resultados para Bread

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the initial stage of this work, two potentiometric methods were used to determine the salt (sodium chloride) content in bread and dough samples from several cities in the north of Portugal. A reference method (potentiometric precipitation titration) and a newly developed ion-selective chloride electrode (ISE) were applied. Both methods determine the sodium chloride content through the quantification of chloride. To evaluate the accuracy of the ISE, bread and respective dough samples were analyzed by both methods. Statistical analysis (0.05 significance level) indicated that the results of these methods did not differ significantly. Therefore the ISE is an adequate alternative for the determination of chloride in the analyzed samples. To compare the results of these chloride-based methods with a sodium-based method, sodium was quantified in the same samples by a reference method (atomic absorption spectrometry). Significant differences between the results were verified. In several cases the sodium chloride content exceeded the legal limit when the chloride-based methods were used, but when the sodium-based method was applied this was not the case. This could lead to the erroneous application of fines and therefore the authorities should supply additional information regarding the analytical procedure for this particular control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A QuEChERS method for the extraction of ochratoxin A (OTA) from bread samples was evaluated. A factorial design (23) was used to find the optimal QuEChERS parameters (extraction time, extraction solvent volume and sample mass). Extracts were analysed by LC with fluorescence detection. The optimal extraction conditions were: 5 g of sample, 15 mL of acetonitrile and 3 min of agitation. The extraction procedure was validated by systematic recovery experiments at three levels. The recoveries obtained ranged from 94.8% (at 1.0 μg kg -1) to 96.6% (at 3.0 μg kg -1). The limit of quantification of the method was 0.05 μg kg -1. The optimised procedure was applied to 20 samples of different bread types (‘‘Carcaça’’, ‘‘Broa de Milho’’, and ‘‘Broa de Avintes’’) highly consumed in Portugal. None of the samples exceeded the established European legal limit of 3 μg kg -1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of OTA in fresh and packed wheat and in maize bread and the evaluation of the exposure degree through their consumption in two Portuguese populations from Porto and Coimbra, during the winter of 2007, were studied. One hundred and sixty eight bread samples, 61 maize and 107 wheat, were analysed by liquid chromatography–fluorescence detection (LC–FD). The results showed that 84% of samples were contaminated, with a maximum level of 3.85 ng/g (above the EU maximum limit, 3 ng/g). Fresh wheat bread presented higher levels than packed wheat bread. Moreover, the traditional maize bread, in either city, was consistently more contaminated than wheat bread, 0.25 vs 0.19 ng/g, and 0.48 vs 0.34 ng/ g for Porto and Coimbra, respectively. Avintes maize bread showed the highest mean contamination and maximum levels. The higher estimated daily intake of OTA from both types of bread in the population of Coimbra compared to Porto reflects the higher average contamination of bread in the first city.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nearly ubiquitous consumption of cereals all over the world renders them an important position in international nutrition, but concurrently allocates exposure to possible contained contaminants. Mycotoxins are natural food contaminants, difficult to predict, evade, and reduce, so it is important to establish the real contribution of each contaminated food product, with the aim to evaluate mycotoxin exposure. This was the key objective of this survey and analysis for ochratoxin A content on 274 samples of commercialized bread in the Portuguese market, during the winter 2007. Different bread products were analyzed through an HPLC-FD method, including traditional types, novel segments, and different grain based bread products. A wide-ranging low level contamination was observed in all regions and types of bread products analyzed, especially in the Porto and Coimbra regions, and in the maize and whole-grain or fiber-enriched bread. Nevertheless, the exposure through contaminated wheat bread continues to be the most significant, given its high consumption and dominance in relation to the other types of bread.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method using microwave-assisted extraction (MAE) and liquid chromatography (LC) with fluorescence detection (FD) for the determination of ochratoxin A (OTA) in bread samples is described. A 24 orthogonal composite design coupled with response surface methodology was used to study the influence of MAE parameters (extraction time, temperature, solvent volume, and stirring speed) in order to maximize OTA recovery. The optimized MAE conditions were the following: 25 mL of acetonitrile, 10 min of extraction, at 80 °C, and maximum stirring speed. Validation of the overall methodology was performed by spiking assays at five levels (0.1–3.00 ng/g). The quantification limit was 0.005 ng/g. The established method was then applied to 64 bread samples (wheat, maize, and wheat/maize bread) collected in Oporto region (Northern Portugal). OTAwas detected in 84 % of the samples with a maximum value of 2.87 ng/g below the European maximum limit established for OTA in cereal products of 3 ng/g.