24 resultados para Body shape Questionnaire

em Instituto Politécnico do Porto, Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dairy foods comprise a range of products with varying nutritional content. The intake of dairy products (DPs) has been shown to have beneficial effects on body weight and body fat. This study aimed to examine the independent association between DP intake, body mass index (BMI), and percentage body fat (%BF) in adolescents. A cross-sectional, school-based study was conducted with 1,001 adolescents (418 boys), ages 15–18 years, from the Azorean Archipelago, Portugal. Anthropometric measurements were recorded (weight and height), and %BF was assessed using bioelectric impedance analysis. Adolescent food intake was measured using a self-administered, semiquantitative food frequency questionnaire. Data were analyzed separately for girls and boys, and separate multiple linear regression analysis was used to estimate the association between total DP, milk, yogurt, and cheese intake, BMI, and %BF, adjusting for potential confounders. For boys and girls, respectively, total DP consumption was 2.6 ± 1.9 and 2.9 ± 2.5 servings/day (P = 0.004), while milk consumption was 1.7 ± 1.4 and 2.0 ± 1.7 servings/day (P = 0.001), yogurt consumption was 0.5 ± 0.6 and 0.4 ± 0.7 servings/day (P = 0.247), and cheese consumption was 0.4 ± 0.6 and 0.5 ± 0.8 servings/day (P = 0.081). After adjusting for age, birth weight, energy intake, protein, total fat, sugar, dietary fiber, total calcium intake, low-energy reporters, parental education, pubertal stage, and physical activity, only milk intake was negatively associated with BMI and %BF in girls (respectively, girls: β = −0.167, P = 0.013; boys: β = −0.019, P = 0.824 and girls: β = −0.143, P = 0.030; boys: β = −0.051, P = 0.548). Conclusion: We found an inverse association between milk intake and both BMI and %BF only in girls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A introdução de Ressonância Magnética de Corpo Inteiro (RM-CI) de alta resolução é baseada no desenvolvimento rápido e intensivo dos equipamentos de RM. Estes avanços associados ao aparecimento de novos métodos de aquisição de imagem, como as técnicas de Multistation ou imagem paralela impulsionam a RM-CI. Associado ao desenvolvimento tecnológico, a RM-CI apresenta vantagens clínicas essencialmente para patologias oncológicas como é o caso das metástases ósseas, e para patologias do foro cardiovascular. Muitas destas situações ainda se encontram em investigação mas os primeiros resultados têm superado todas as expectativas nomeadamente a RM-CI com a aplicação da técnica de Difusão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objectivo deste estudo é determinar as propriedades psicométricas da versão portuguesa do Stroke Aphasic Depression Questionnaire-21 (SADQ-21). Envolveu 120 sujeitos, 33 dos quais com afasia. Os resultados demonstraram que o SADQ-21 revela uma consistência interna muito elevada (α=0,87). A validade de construção identificou cinco domínios. A variância total explicada pelos factores foi elevada (65,85%). A correlação entre a medida de ouro e o SADQ-21 é estatisticamente significativa (p<0,05). Os indivíduos com afasia estão significativamente mais deprimidos que os sem afasia (p=0,0001). Conclui-se que o SADQ-21 é um instrumento adequado para a avaliação da sintomatologia depressiva em pessoas com afasia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Obesidade é considerada um grave problema de saúde pública, com consequências negativas para os indivíduos obesos, nomeadamente dificuldades no desempenho de atividades de vida diária, na locomoção e na prática de exercício físico, o que pode restringir a participação em atividades sociais e de lazer. Esta investigação consiste num estudo quantitativo descritivo e tem como objetivo principal descrever de que forma os indivíduos adultos obesos classificam a sua adaptação ocupacional, a partir dos conceitos de identidade e competência ocupacional. Com este estudo, pretende-se ainda verificar se os indivíduos obesos apresentam níveis de atividade física mais baixos e valores mais elevados de pressão plantar, em relação a indivíduos com peso normal. A amostra é constituída por dez indivíduos adultos, de ambos os sexos, com índice de massa corporal igual (IMC) ou superior a 30 Kg/m2, e os instrumentos de avaliação utilizados são o Questionário Ocupacional (adaptado por N. Riopel com assistência de G. Kielhofner e J. Hawkins Watts – 1986), o IPAQ – Versão Curta e o Sistema de Palmilhas Pedar. A partir dos resultados, pode-se verificar que os indivíduos obesos apresentam uma rotina diária em que a maioria das atividades realizadas está relacionada com a casa, o trabalho e o descanso e que a percentagem de atividades de lazer em que participam é reduzida. No entanto, parecem satisfeitos com o seu desempenho na maior parte das atividades, consideram que muitas delas são importantes para si e estão motivados para as realizar. Dos resultados obtidos, podemos sugerir que os indivíduos obesos apresentam boa adaptação ocupacional. Pode-se ainda dizer que os indivíduos obesos apresentam um baixo nível de intensidade de atividade física, não se observando diferenças significativas relativamente aos indivíduos com peso normativo e que os seus valores máximos de pressão plantar normalizados são inferiores quando comparados com a população de peso normal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanisms of speech production are complex and have been raising attention from researchers of both medical and computer vision fields. In the speech production mechanism, the articulator’s study is a complex issue, since they have a high level of freedom along this process, namely the tongue, which instigates a problem in its control and observation. In this work it is automatically characterized the tongues shape during the articulation of the oral vowels of Portuguese European by using statistical modeling on MR-images. A point distribution model is built from a set of images collected during artificially sustained articulations of Portuguese European sounds, which can extract the main characteristics of the motion of the tongue. The model built in this work allows under standing more clearly the dynamic speech events involved during sustained articulations. The tongue shape model built can also be useful for speech rehabilitation purposes, specifically to recognize the compensatory movements of the articulators during speech production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Increased fat mass is becoming more prevalent in women and its accumulation in the abdominal region can lead to numerous health risks such as diabetes mellitus. The clay body wrap using compounds such as green clay, green tea and magnesium sulfate, in addition to microcurrent, may reduce abdominal fat mass and minimize or prevent numerous health problems. Objective This study aims at measuring the influence of the clay body wrap with microcurrent and aerobic exercise on abdominal fat. Methods Nineteen female patients, randomized into intervention (n = 10) and control (n = 9) groups, were evaluated using ultrasound for visceral and subcutaneous abdominal fat, calipers and abdominal region perimeter for subcutaneous fat and bioimpedance for weight, fat mass percentage and muscular mass. During 10 sessions (5 weeks, twice a week) both groups performed aerobic exercise in a cycloergometer and a clay body wrap with microcurrent was applied to the intervention group. Results When comparing both groups after 5 weeks of protocol, there was a significant decrease in the subcutaneous fat around left anterior superior iliac spine in the intervention group (ρ = 0.026 for a confidence interval 95%). When comparing initial and final abdominal fat in the intervention group, measured by ultrasound (subcutaneous and visceral fat) and by skinfold (subcutaneous fat), we detected a significant abdominal fat reduction. Conclusion This study demonstrated that the clay body wrap used with microcurrent and aerobic exercise can have a positive effect on central fat reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Diet and physical activity (PA) are recognized as important factors to prevent abdominal obesity (AO), which is strongly associated with chronic diseases. Some studies have reported an inverse association between milk consumption and AO. Objective: This study examined the association between milk intake, PA and AO in adolescents. Methods: A cross-sectional study was conducted with 1209 adolescents, aged 15–18 from the Azorean Archipelago, Portugal in 2008. AO was defined by a waist circumference at or above the 90th percentile. Adolescent food intake was measured using a semi-quantitative food frequency questionnaire, and milk intake was categorized as ‘low milk intake’ (<2 servings per day) or ‘high milk intake’ ( 2 servings per day). PA was assessed via a self-report questionnaire, and participants were divided into active (>10 points) and low-active groups ( 10 points) on the basis of their reported PA. They were then divided into four smaller groups, according to milk intake and PA: (i) low milk intake/low active; (ii) low milk intake/active; (iii) high milk intake/low active and (iv) high milk intake/active. The association between milk intake, PA and AO was evaluated using logistic regression analysis, and the results were adjusted for demographic, body mass index, pubertal stage and dietary confounders. Results: In this study, the majority of adolescents consumed semi-skimmed or skimmed milk (92.3%). The group of adolescents with high level of milk intake and active had a lower proportion of AO than did other groups (low milk intake/low active: 34.2%; low milk intake/active: 26.9%; high milk intake/low active: 25.7%; high milk intake/active: 21.9%, P = 0.008). After adjusting for confounders, low-active and active adolescents with high levels of milk intake were less likely to have AO, compared with low-active adolescents with low milk intake (high milk intake/low active, odds ratio [OR] = 0.412, 95% confidence intervals [CI]: 0.201– 0.845; high milk intake/active adolescents, OR = 0.445, 95% CI: 0.235–0.845).Conclusion: High milk intake seems to have a protective effect on AO, regardless of PA level

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesively-bonded joints are extensively used in several fields of engineering. Cohesive Zone Models (CZM) have been used for the strength prediction of adhesive joints, as an add-in to Finite Element (FE) analyses that allows simulation of damage growth, by consideration of energetic principles. A useful feature of CZM is that different shapes can be developed for the cohesive laws, depending on the nature of the material or interface to be simulated, allowing an accurate strength prediction. This work studies the influence of the CZM shape (triangular, exponential or trapezoidal) used to model a thin adhesive layer in single-lap adhesive joints, for an estimation of its influence on the strength prediction under different material conditions. By performing this study, guidelines are provided on the possibility to use a CZM shape that may not be the most suited for a particular adhesive, but that may be more straightforward to use/implement and have less convergence problems (e.g. triangular shaped CZM), thus attaining the solution faster. The overall results showed that joints bonded with ductile adhesives are highly influenced by the CZM shape, and that the trapezoidal shape fits best the experimental data. Moreover, the smaller is the overlap length (LO), the greater is the influence of the CZM shape. On the other hand, the influence of the CZM shape can be neglected when using brittle adhesives, without compromising too much the accuracy of the strength predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Abdominal fat is associated with metabolic disorders, leading to cardiovascular risk factors and numerous diseases. This study aimed to analyze the effect of plaster body wrap in combination with aerobic exercise on abdominal fat. Methods Nineteen female volunteers were randomly divided into intervention group (IG; n = 10) performing aerobic exercise with plaster body wrap, and control group (CG; n = 9) performing only exercise. Subcutaneous and visceral fat were measured using ultrasound; subcutaneous fat was also estimated on analysis of skinfolds and abdominal perimeters. Results At the end of the 10-sessions protocol, the IG demonstrated a significant decrease (p ≤ 0.05) in subcutaneous fat at the left anterior superior iliac spine (ASIS) level and in iliac crest perimeter measurements. A large intervention effect size strength (0.80) was found in subcutaneous fat below the navel and a moderate effect size strength on the vertical abdominal skinfold (0.62) and the perimeter of the most prominent abdominal point (0.57). Comparing the initial and final data of each group, the IG showed a significant decrease in numerous variables including visceral and subcutaneous fat above and below the navel measured by ultrasound (p ≤ 0.05). Conclusion Plaster body wrap in combination with aerobic exercise seems to be effective for abdominal fat reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider reliable communications in Body Area Networks (BAN), where a set of nodes placed on human body are connected using wireless links. In order to keep the Specific Absorption Rate (SAR) as low as possible for health safety reasons, these networks operate in low transmit power regime, which however, is known to be error prone. It has been observed that the fluctuations of the Received Signal Strength (RSS) at the nodes of a BAN on a moving person show certain regularities and that the magnitude of these fluctuations are significant (5 - 20 dB). In this paper, we present BANMAC, a MAC protocol that monitors and predicts the channel fluctuations and schedules transmissions opportunistically when the RSS is likely to be higher. The MAC protocol is capable of providing differentiated service and resolves co-channel interference in the event of multiple co-located BANs in a vicinity. We report the design and implementation details of BANMAC integrated with the IEEE 802.15.4 protocol stack. We present experimental data which show that the packet loss rate (PLR) of BANMAC is significantly lower as compared to that of the IEEE 802.15.4 MAC. For comparable PLR, the power consumption of BANMAC is also significantly lower than that of the IEEE 802.15.4. For co-located networks, the convergence time to find a conflict-free channel allocation was approximately 1 s for the centralized coordination mechanism and was approximately 4 s for the distributed coordination mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant research efforts are being devoted to Body Area Networks (BAN) due to their potential for revolutionizing healthcare practices. Energy-efficiency and communication reliability are critically important for these networks. In an experimental study with three different mote platforms, we show that changes in human body shadowing as well as those in the relative distance and orientation of nodes caused by the common human body movements can result in significant fluctuations in the received signal strength within a BAN. Furthermore, regular movements, such as walking, typically manifest in approximately periodic variations in signal strength. We present an algorithm that predicts the signal strength peaks and evaluate it on real-world data. We present the design of an opportunistic MAC protocol, named BANMAC, that takes advantage of the periodic fluctuations of the signal strength to achieve high reliability even with low transmission power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless Body Area Networks (WBANs) have emerged as a promising technology for medical and non-medical applications. WBANs consist of a number of miniaturized, portable, and autonomous sensor nodes that are used for long-term health monitoring of patients. These sensor nodes continuously collect information of patients, which are used for ubiquitous health monitoring. In addition, WBANs may be used for managing catastrophic events and increasing the effectiveness and performance of rescue forces. The huge amount of data collected by WBAN nodes demands scalable, on-demand, powerful, and secure storage and processing infrastructure. Cloud computing is expected to play a significant role in achieving the aforementioned objectives. The cloud computing environment links different devices ranging from miniaturized sensor nodes to high-performance supercomputers for delivering people-centric and context-centric services to the individuals and industries. The possible integration of WBANs with cloud computing (WBAN-cloud) will introduce viable and hybrid platform that must be able to process the huge amount of data collected from multiple WBANs. This WBAN-cloud will enable users (including physicians and nurses) to globally access the processing and storage infrastructure at competitive costs. Because WBANs forward useful and life-critical information to the cloud – which may operate in distributed and hostile environments, novel security mechanisms are required to prevent malicious interactions to the storage infrastructure. Both the cloud providers and the users must take strong security measures to protect the storage infrastructure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Patient-centredness has become an important aspect of health service delivery; however, there are a limited number of studies that focus on this concept in the domain of hearing healthcare. The objective of this study was to examine and compare audiologists’ preferences for patient-centredness in Portugal, India and Iran. Design The study used a cross-sectional survey design with audiologists recruited from three different countries. Participants A total of 191 fully-completed responses were included in the analysis (55 from Portugal, 78 from India and 58 from Iran). Main outcome measure The Patient–Practitioner Orientation Scale (PPOS). Results PPOS mean scores suggest that audiologists have a preference for patient-centredness (ie, mean of 3.6 in a 5-point scale). However, marked differences were observed between specific PPOS items suggesting these preferences vary across clinical situations. A significant level of difference (p<0.001) was found between audiologists’ preferences for patient-centredness in three countries. Audiologists in Portugal had a greater preference for patient-centredness when compared to audiologists in India and Iran, although no significant differences were found in terms of age and duration of experience among these sample populations. Conclusions There are differences and similarities in audiologists’ preferences for patient-centredness among countries. These findings may have implications for the training of professionals and also for clinical practice in terms of optimising hearing healthcare across countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Increased fat mass is becoming more prevalent in women and its accumulation in the abdominal region can lead to numerous health risks such as diabetes mellitus. The clay body wrap using compounds such as green clay, green tea and magnesium sulfate, in addition to microcurrent, may reduce abdominal fat mass and minimize or prevent numerous health problems. Objective: This study aims at measuring the influence of the clay body wrap with microcurrent and aerobic exercise on abdominal fat. Methods: Nineteen female patients, randomized into intervention (n = 10) and control (n = 9) groups, were evaluated using ultrasound for visceral and subcutaneous abdominal fat, calipers and abdominal region perimeter for subcutaneous fat and bioimpedance for weight, fat mass percentage and muscular mass. During 10 sessions (5 weeks, twice a week) both groups performed aerobic exercise in a cycloergometer and a clay body wrap with microcurrent was applied to the intervention group. Results: When comparing both groups after 5 weeks of protocol, there was a significant decrease in the subcutane- ous fat around left anterior superior iliac spine in the intervention group (ρ = 0.026 for a confidence interval 95%). When comparing initial and final abdominal fat in the intervention group, measured by ultrasound (subcutaneous and visceral fat) and by skinfold (subcutaneous fat), we detected a significant abdominal fat reduction. Conclusion: This study demonstrated that the clay body wrap used with microcurrent and aerobic exercise can have a positive effect on central fat reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A growing body of research suggests that vitamin D might play an important role in overall health. No data exist on vitamin D intake for the Azorean adolescent population. The purpose of this study was to assess vitamin D intake and investigate a possible association between vitamin D intake and cardiometabolic risk factors in Azorean adolescents. Methods: A cross-sectional school-based study was conducted on 496 adolescents (288 girls) aged 15–18 years from the Azorean Islands, Portugal. Anthropometric measurements (waist circumference and height), blood pressure (systolic), and plasma biomarkers [fasting glucose, insulin, total cholesterol (TC), high-density lipoprotein cholesterol (HDL-C), and triglycerides (TGs)] were measured to assess metabolic risk. Homeostasis model assessment (HOMA), TC-to-HDL-C ratio, and waist-to-height ratio were calculated. For each of these variables, a Z-score was computed by age and sex. A metabolic risk score was constructed by summing the Zscores of all individual risk factors. High risk was considered when the individual had ‡ 1 standard deviation(SD) of this score. Vitamin D intake was assessed with a semiquantitative food frequency questionnaire. Participants were classified into quartiles of vitamin D intake. Logistic regression was used to determine odds ratios for high cardiometabolic risk scores after adjusting for total energy intake, pubertal stage, fat mass percentage, and cardiorespiratory fitness. Results: Mean (SD) vitamin D intake was 5.8 (6.5) mg/day, and 9.1% of Azorean adolescents achieved the estimated average requirement of vitamin D (10 mg/day or 400 IU). Logistic regression showed that the odds ratio for a high cardiometabolic risk score was 3.35 [95% confidence interval (CI) 1.28–8.75] for adolescents in the lowest vitamin D intake quartile in comparison with those in the highest vitamin D intake quartile, even after adjustment for confounders. Conclusion: A lower level of vitamin D intake was associated with worse metabolic profile among Azorean adolescents.