10 resultados para Air Temperature
em Instituto Politécnico do Porto, Portugal
Resumo:
Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.
Resumo:
The ventilation efficiency concept is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the building spaces. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by Computational fluid dynamics (CFD). Were compared the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE), the two indicators most internationally accepted. The main results from this work shows that the values of the numerical simulations are in good agreement with experimental measurements and also, that the solutions to be adopted for maximizing the ventilation efficiency should be the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.
Resumo:
A Indústria Têxtil do Ave S.A. (ITA) dedica-se, desde 1948, à produção de componentes têxteis para pneus em forma de fio torcido (corda) e tela. Estes componentes são quimicamente activados e impregnados em estufas, possibilitando assim a posterior adesão ao pneu. A máquina de impregnar corda Single End é composta pelos grupos de estiragem, por um recipiente contendo a solução química e por 4 estufas em série. A máquina de impregnar tela Zell é composta pelos grupos de estiragem, pelos acumuladores de saída e entrada, pelos recipientes com as soluções químicas e por um grupo de 7 estufas em série. O aquecimento das estufas é feito através da queima de gás natural. O presente trabalho teve como objectivo a realização de uma auditoria energética à ITA com um especial destaque às máquinas de impregnar corda (Single End) e tela (Zell). As correntes de entrada que contribuem para a potência térmica de impregnação são a combustão do gás natural, o ar de combustão, o ar fresco, o artigo em verde e as soluções químicas. As correntes de saída correspondem aos gases de combustão e exaustão, ao artigo impregnado e às perdas térmicas. A auditoria à máquina Single End mostrou que a potência térmica de impregnação é de 413,1 kW. Dessa potência térmica, 77,2% correspondem à combustão do gás natural, 6,7% ao ar de combustão, 15% ao ar fresco, 0,7% às cordas em verde e 0,4% à solução química. Da potência térmica de saída, 88,4% correspondem aos gases de combustão e exaustão, 3,2% às cordas impregnadas e 8,4% às perdas térmicas. Da auditoria à máquina Zell observou-se que a potência térmica de impregnação é de 5630,7 kW. Dessa potência, 73,3% corresponde à combustão do gás natural, 1,6% ao ar de combustão, 24,5% ao ar fresco, 0,3% à tela em verde e 0,3% às soluções químicas. Da potência térmica de saída, 65,2% correspondem aos gases de combustão e exaustão, 3,1% à tela impregnada e 31,7% às perdas térmicas. Foram sugeridas como medidas de optimização a redução dos caudais de exaustão das estufas e o aumento de temperatura do ar fresco. O aumento da temperatura do ar fresco da máquina de impregnar Single End para 50 ºC, usando ar quente dos torcedores, leva a uma poupança de 0,22 €/h, com um período de retorno do investimento de 13 anos e 4 meses enquanto o aumento para 120 ºC, usando o calor dos gases de combustão e exaustão, reduz os custos em 0,88 €/h, sendo o período de retorno para esse investimento de 2 anos e 6 meses. Na máquina de impregnar Zell, uma redução de 15% no caudal de exaustão numa das estufas leva a ganhos de 3,43 €/h. O aumento de temperatura do ar fresco para 45 ºC, usando o calor de gases de combustão e exaustão, leva a uma poupança de 9,93 €/h sendo o período de retorno para cada uma das duas sugestões de investimento de 5 meses e 9 meses.
Resumo:
A Qualidade do Ar Interior (QAI) é um fator de grande preocupação. A importância de manter um ambiente salubre é mais acentuada em estabelecimentos escolares (EE), tendo em conta, que no interior destes permanecem crianças durante um elevado período de tempo. É fundamental garantir uma boa QAI nos edifícios escolares, de forma a salvaguardar a saúde, o bem-estar e o conforto dos ocupantes, bem como, não comprometer o seu desempenho escolar. Recentemente, foram construídos novos edifícios escolares e alguns dos existentes foram alvo de obras de remodelação. Contudo, a crescente tendência em construir edifícios cada vez mais herméticos, com vista à diminuição dos gastos de energia, origina problemas como a reduzida ventilação dos espaços. Vários estudos têm demonstrado a influência das atividades de limpeza na QAI. No entanto, verifica-se que na maioria das escolas não existem ainda procedimentos de limpeza padronizados. A falta de instruções de trabalho e a ausência de formação às assistentes operacionais pode comprometer a eficácia dos procedimentos de higienização, o que poderá ter influência na QAI dos espaços. Este estudo teve como principal objetivo avaliar a QAI em escolas básicas de 1.º ciclo. Foram contemplados no estudo fatores como a tipologia do edifício, a ocupação das salas e as atividades de limpeza. Procedeu-se à caracterização dos EE e à monitorização de parâmetros ambientais, como a temperatura do ar, a humidade relativa, a velocidade do ar, o dióxido de carbono, o monóxido de carbono, as partículas, os microrganismos mesófilos totais e os fungos. Estes parâmetros foram avaliados nas salas com ocupação, sem ocupação e durante a implementação de um plano de higienização. A ventilação inadequada parece ser o fator que mais condiciona a QAI das salas de aula avaliadas. Registaram-se elevadas concentrações de dióxido de carbono e de microrganismos mesófilos totais, que parecem estar relacionados com a permanência dos ocupantes nos locais e com a falta de ventilação adequada dos espaços. A concentração de dióxido de carbono foi mais elevada em edifícios recentes. Os picos elevados na concentração de partículas parecem estar associados com as atividades dos ocupantes. Obtiveram-se concentrações menores de fungos e de microrganismos mesófilos totais ao longo da implementação do plano de higienização, o que poderá significar que os procedimentos de limpeza contribuem para reduzir os níveis de contaminação dos espaços interiores. No entanto, tendo em conta, que a concentração de microrganismos mesófilos totais permaneceu elevada, as operações de limpeza parecem não ser suficientes para garantir uma boa QAI. O aumento da ventilação dos espaços poderia contribuir significativamente para a melhoria da QAI dos espaços avaliados.
Resumo:
Buildings account for 40% of total energy consumption in the European Union. The reduction of energy consumption in the buildings sector constitute an important measure needed to reduce the Union's energy dependency and greenhouse gas emissions. The Portuguese legislation incorporate this principles in order to regulate the energy performance of buildings. This energy performance should be accompanied by good conditions for the occupants of the buildings. According to EN 15251 (2007) the four factors that affect the occupant comfort in the buildings are: Indoor Air Quality (IAQ), thermal comfort, acoustics and lighting. Ventilation directly affects all except the lighting, so it is crucial to understand the performance of it. The ventilation efficiency concept therefore earn significance, because it is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the spaces. The two indicators most internationally accepted are the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE). Nowadays with the developed of the Computational Fluid Dynamics (CFD) the behaviour of ventilation can be more easily predicted. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by the MicroFlo module of the IES-VE software for this two indicators. The main conclusions from this work were: that the values of the numerical simulations are in agreement with experimental measurements; the value of the CRE is more dependent of the position of the contamination source, that the strategy used for the air diffusion; the ACE indicator is more appropriate for quantifying the quality of the air diffusion; the solutions to be adopted, to maximize the ventilation efficiency should be, the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.
Resumo:
A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.
Resumo:
The European Union Emissions Trading Scheme (EU ETS) is a cornerstone of the European Union's policy to combat climate change and its key tool for reducing industrial greenhouse gas emissions cost-effectively. The purpose of the present work is to evaluate the influence of CO2 opportunity cost on the Spanish wholesale electricity price. Our sample includes all Phase II of the EU ETS and the first year of Phase III implementation, from January 2008 to December 2013. A vector error correction model (VECM) is applied to estimate not only long-run equilibrium relations, but also short-run interactions between the electricity price and the fuel (natural gas and coal) and carbon prices. The four commodities prices are modeled as joint endogenous variables with air temperature and renewable energy as exogenous variables. We found a long-run relationship (cointegration) between electricity price, carbon price, and fuel prices. By estimating the dynamic pass-through of carbon price into electricity price for different periods of our sample, it is possible to observe the weakening of the link between carbon and electricity prices as a result from the collapse on CO2 prices, therefore compromising the efficacy of the system to reach proposed environmental goals. This conclusion is in line with the need to shape new policies within the framework of the EU ETS that prevent excessive low prices for carbon over extended periods of time.
Resumo:
A presente dissertação realizada na empresa Continental-Indústria Têxtil do Ave, S.A., teve como objetivo a otimização energética da secção das malhas. Esta secção divide-se em duas áreas, a tricotagem e a ramulagem. Os artigos produzidos diferem no seu peso específico, composição e condições de operação, sendo os artigos A, B e C compostos por poliéster e termofixados a 190ºC e os artigos D e E compostos por poliéster e algodão, com uma temperatura de operação de 205ºC. Numa primeira etapa estudou-se o funcionamento da máquina de termofixação – a râmula – que opera em trabalho contínuo a 40 m/min. Esta máquina tem incorporado um permutador de calor, que aquece o ar fresco de entrada com os gases de exaustão das estufas. Posteriormente efetuou-se o levantamento energético de cada artigo, para as áreas de tricotagem e ramulagem. Verificou-se que os artigos D e E, pela sua constituição, são os que apresentam um consumo específico superior, em tep/ton. Entre as várias utilidades consumidas (gás natural, eletricidade e ar comprimido) o gás natural representa mais de 50% do consumo de energia total necessário para a produção de cada artigo. Após a completa análise aos consumos energéticos da râmula, foram realizados ensaios de otimização, tendo-se concluído que a diminuição do caudal de exaustão pode atingir valores de poupança anual de gás natural na ordem dos 3.000 €. Com o objetivo de avaliar o consumo de gás natural, não sendo possível a realização experimental, foram feitas simulações com base em alterações na corrente de entrada de ar fresco no permutador. Foi também estudada a possibilidade de isolamento e revestimento térmico da conduta exterior, projetada para o reaproveitamento do ar dos compressores, tendo-se obtido um orçamento de 2.500 €. Admitindo-se uma gama de temperaturas entre os 40ºC e os 60ºC, com um caudal de insuflação de 30%, obteve-se um payback entre os 0,97 e os 3,28 anos. Numa segunda fase admitiu-se uma temperatura média de 50ºC, aumentando o caudal de insuflação até 100%. O período de retorno obtido variou entre os 0,33 e os 1,38 anos, podendo as poupanças anuais atingirem os 7.600 €.
Estudo de uma bomba de calor de expansão direta assistida por energia solar para a preparação de AQS
Resumo:
Este estudo consiste na caracterização da eficiência energética de uma bomba de calor de expansão direta que utiliza a energia solar como fonte térmica. De uma forma geral, teve-se a obrigação de procurar cada vez mais recursos renováveis e neste sentido a bomba de calor de expansão direta tem um papel importante no aquecimento de águas quentes sanitárias (AQS). Como ponto de partida, foi realizada uma descrição detalhada sobre todos os equipamentos da bomba de calor e elaborado um desenho técnico que identifica todos os componentes. No laboratório (casa inteligente) realizaram-se vários ensaios a fim de interpretar com rigor os resultados obtidos do desempenho da bomba de calor (COP) e do fator médio de desempenho sazonal (SPF). No início, realizaram-se ensaios para determinar as perdas estáticas do sistema termodinâmico, de seguida foram elaborados ensaios segundo a norma EN 16147 e por fim, ensaios de acordo com o perfil de utilização de AQS definido. No estudo experimental do COP, obteve-se uma elevada eficiência energética com um valor médio de 4,12. O COP aumenta para valores médios de 5 quando a temperatura de água no termoacumulador desce para 35ºC. Verificou-se que durante o período diurno o COP aumenta aproximadamente de 10% relativamente ao período noturno. A potência elétrica é mais elevada (450W) quando a água no termoacumulador está perto da temperatura desejável (55ºC), originando um esforço maior da bomba de calor. No estudo experimental do SPF, verificou-se que nos ensaios segundo a norma EN16147 os valores obtidos variaram entre 1,39 e 1,50 (Classe “B”). No estudo realizado de acordo com o perfil de utilização de AQS definido pelo utilizador, o SPF é superior em 12% relativamente ao obtido segundo os ensaios realizados de acordo a norma EN16147. Verificou-se que o aumento da temperatura do ar exterior implica um aumento do SPF (cerca de 2% a 5%), enquanto a energia solar não influência nos resultados.
Resumo:
A procura por alternativas ao atual paradigma energético, que se caracteriza por uma predominância indiscutível das fontes combustíveis fósseis, é o motivo primário desta investigação. A energia emitida pelo Sol que chega à Terra diariamente ultrapassa em várias ordens de grandeza a energia que a nossa sociedade atual necessita. O efeito chaminé é uma das formas de aproveitar essa energia. Este efeito tem origem no diferencial de temperaturas existente entre o interior e o exterior de uma chaminé, que provoca um gradiente nas massas volúmicas do fluido entre o interior e o exterior da chaminé, induzindo assim um fluxo de ar. Esta diferença de temperaturas radica na exposição da face exterior da chaminé à radiação solar. No sistema que nos propomos estudar, o ar entra na chaminé por pequenos orifícios situados na sua base, e, ao tomar contacto com as paredes internas da chaminé, aquece desde a temperatura ambiente, Ta, até à temperatura interna, Ti . Este aumento de temperatura torna o ar dentro da chaminé mais “leve” em comparação com o ar mais frio do exterior levando-o a ascender ao longo do interior da chaminé. Este escoamento contém energia cinética que pode, por exemplo, ser transformada em energia elétrica por intermédio de turbinas. A eficiência de conversão da energia será tanto maior quanto menor for a velocidade do ar a jusante da turbina. Esta tecnologia poderá ser instalada de forma descentralizada, como acontece com as atuais centrais concentradoras solares térmicas e fotovoltaicas localizadas na periferia de grandes cidades ou, alternativamente, poderá ser inserida no próprio tecido urbanístico. A investigação demonstra que as dimensões da chaminé, a irradiação e a temperatura do ar são os fatores com maior impacto na potência hidráulica gerada.