14 resultados para Adiabatic temperature lapse rate, low

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Titanium films have been deposited on stainless steel metal sheets using dc magnetron sputtering technique at different substrate temperatures. The structure of the titanium films strongly depend on the substrate temperature. The titanium film deposited at the substrate temperature lower than 300 ◦C has a loose flat sheet grains structure and the titanium film prepared at the substrate temperature higher than 500 ◦C has a dense nubby grains structure. The DSSC assembled using stainless steel sheet coated with titanium film deposited at high substrate temperature has a low charge transfer resistance in the TiO2/Ti interface and results in a high conversion efficiency. The DSSC assembled using stainless steel sheet coated with titanium film deposited at temperature higher than 500 ◦C has higher conversion efficiency than that assembled using titanium metal sheet as the substrate. The maximum conversion efficiency, 2.26% is obtained for DSSC assembled using stainless steel sheet coated with titanium film deposited at 700 ◦C substrate temperature, which is about 70% of the conversion efficiency of the FTO reference cell used in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low-rate low-power consumption and low-cost communication are the key points that lead to the specification of the IEEE 802.15.4 standard. This paper overviews the technical features of the physical layer and the medium access control sublayer mechanisms of the IEEE 802.15.4 protocol that are most relevant for wireless sensor network applications. We also discuss the ability of IEEE 802.15.4 to fulfil the requirements of wireless sensor network applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O principal objectivo desta dissertação foi avaliar a evolução hidrogeoquímica das águas minerais de Entre‐os‐Rios, para uma melhor compreensão do modelo hidrogeológico conceptual deste sistema hidromineral. Desta forma, foram coligidos diversos dados hidroquímicos, quer das nascentes clássicas (Torre, Curveira, Ardias, Arcos Esquerda e Arcos Direita), quer do furo Barbeitos. Foram compiladas e analisadas oitenta análises hidroquímicas no período 1938‐2012, incluindo características organolépticas (cheiro, cor e turbidez), diversas propriedades físico-químicas (temperatura, pH, condutividade eléctrica, sulfuração, etc), os principais catiões e aniões (bicarbonato, fluoreto, sódio, lítio, etc) e os elementos vestigiários (chumbo, tungsténio, boro, etc). Além disso, foram integrados os dados históricos disponíveis de finais do século XIX e inícios do século XX. Foram igualmente reunidos e discutidos alguns dados isotópicos (oxigénio‐18, deutério e trítio). O recurso hidromineral de Entre‐os‐Rios está condicionado pela litologia e pelas condições tectónicas. As análises químicas revelaram que as águas minerais de Entre‐os‐Rios apresentam uma estabilidade química nos últimos 100 anos. Estas águas são orto‐ a hipertermais, fracamente mineralizadas, de reacção alcalina, sulfídricas, bicarbonatadas sódicas, carbonatadas e muito fluoretadas. Estas características são claramente distintas das águas normais da região. As águas de Entre‐os‐Rios são muito semelhantes às águas minerais de S. Vicente e, em diversos parâmetros, bastante diferentes das águas minerais das Caldas da Saúde. Os dados isotópicos permitiram concluir que as águas de Entre‐os‐Rios têm uma origem meteórica, com um tempo de residência longo no sistema aquífero, e que são, muito provavelmente, submodernas, com uma recarga anterior a 1952. Na região de Entre‐os‐Rios coexistem três sistemas aquíferos, um sistema granítico superficial, livre e um sistema livre a semi‐confinado, ambos com circulação de águas normais, e um sistema aquífero granítico, profundo, confinado, com circulação de água mineral.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Airflow rate is one of the most important parameters for the soil vapor extraction of contaminated sites, due to its direct influence on the mass transfer occurring during the remediation process. This work reports the study of airflow rate influence on soil vapor extractions, performed in sandy soils contaminated with benzene, toluene, ethylbenzene, xylene, trichloroethylene and perchloroethylene. The objectives were: (i) to analyze the influence of airflow rate on the process; (ii) to develop a methodology to predict the remediation time and the remediation efficiency; and (iii) to select the most efficient airflow rate. For dry sandy soils with negligible contents of clay and natural organic matter, containing the contaminants previously cited, it was concluded that: (i) if equilibrium between the pollutants and the different phases present in the soil matrix was reached and if slow diffusion effects did not occur, higher airflow rates exhibited the fastest remediations, (ii) it was possible to predict the remediation time and the efficiency of remediation with errors below 14%; and (iii) the most efficient remediation were reached with airflow rates below 1.2 cm3 s 1 standard temperature and pressure conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, an experimental study was performed on the influence of plug-filling, loading rate and temperature on the tensile strength of single-strap (SS) and double-strap (DS) repairs on aluminium structures. Whilst the main purpose of this work was to evaluate the feasibility of plug-filling for the strength improvement of these repairs, a parallel study was carried out to assess the sensitivity of the adhesive to external features that can affect the repairs performance, such as the rate of loading and environmental temperature. The experimental programme included repairs with different values of overlap length (L O = 10, 20 and 30 mm), and with and without plug-filling, whose results were interpreted in light of experimental evidence of the fracture modes and typical stress distributions for bonded repairs. The influence of the testing speed on the repairs strength was also addressed (considering 0.5, 5 and 25 mm/min). Accounting for the temperature effects, tests were carried out at room temperature (≈23°C), 50 and 80°C. This permitted a comparative evaluation of the adhesive tested below and above the glass transition temperature (T g), established by the manufacturer as 67°C. The combined influence of these two parameters on the repairs strength was also analysed. According to the results obtained from this work, design guidelines for repairing aluminium structures were

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low-loss power transmission gears operate at lower temperature than conventional ones because their teeth geometry is optimized to reduce friction. The main objective of this work is to compare the operating stabilization temperature and efficiency of low-loss austempered ductile iron (ADI) and carburized steel gears. Three different low-loss tooth geometries were adopted (types 311, 411 and 611, all produced using standard 20° pressure angle tools) and corresponding steel and ADI gears were tested in a FZG machine. The results obtained showed that low-loss geometries had a significant influence on power loss, gears 611 generating lower power loss than gears 311. At low speeds (500 and 1000 rpm) and high torque ADI gears generated lower power loss than steel gears. However, at high speed and high torque (high input power and high stabilization temperature) steel gears had better efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado Engenharia Química. Ramo Tecnologias de Protecção Ambiental

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Em Portugal existem muitos espaços comerciais e industriais em que as necessidades térmicas de arrefecimento são muito superiores às necessidades de aquecimento devido aos ganhos internos que advêm da existência de equipamentos e da iluminação dos edifícios, assim como, da presença das pessoas. A instalação de sistemas convencionais de ar condicionado para espaços comerciais e industriais de grande dimensão está geralmente associada ao transporte de grandes caudais de ar, e consequentemente, a elevados consumos de energia primária, e também, elevados custos de investimento, de manutenção e de operação. O arrefecedor evaporativo é uma solução de climatização com elevada eficiência energética, cujo princípio de funcionamento promove a redução do consumo de energia primária nos edifícios. A metodologia utilizada baseou-se na criação de uma ferramenta informática de simulação do funcionamento de um protótipo de um arrefecedor evaporativo. Foi efetuada a modelação matemática das variáveis dinâmicas envolvidas, dos processos de transferência de calor e de massa, assim como dos balanços de energia que ocorrem no arrefecedor evaporativo. A ferramenta informática desenvolvida permite o dimensionamento do protótipo do arrefecedor evaporativo, sendo determinadas as caraterísticas técnicas (potência térmica, caudal, eficiência energética, consumo energético e consumo e água) de acordo com o tipo de edifício e com as condições climatéricas do ar exterior. Foram selecionados três dimensionamentos de arrefecedores evaporativos, representativos de condições reais de uma gama baixa, média e elevada de caudais de ar. Os resultados obtidos nas simulações mostram que a potência de arrefecimento (5,6 kW, 16,0 kW e 32,8 kW) e o consumo de água (8 l/h, 23,9 l/h e 48,96 l/h) aumentam com o caudal de ar do arrefecedor, 5.000 m3/h, 15.000 m3/h e 30.000 m3/h, respetivamente. A eficácia de permuta destes arrefecedores evaporativos, foi de 69%, 66% e 67%, respetivamente. Verificou-se que a alteração de zona climática de V1 para V2 implicou um aumento de 39% na potência de arrefecimento e de 20% no consumo de água, e que, a alteração de zona climática de V2 para V3 implicou um aumento de 39% na potência de arrefecimento e de 39% no consumo de água. O arrefecedor evaporativo apresenta valores de consumo de energia elétrica entre 40% a 80% inferiores aos dos sistemas de arrefecimento convencionais, sendo este efeito mais intenso quando a zona climática de verão se torna mais severa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A crescente utilização de dispositivos móveis com diferentes finalidades é uma realidade. Com estes dispositivos, o utilizador tem a necessidade de aceder e usar dados em tempo real provenientes de diversas fontes. Uma tendência acentuada passa pela incorporação destes dispositivos móveis no vestuário, designados por dispositivos wearable. Segundo a empresa IMS Research, o mercado deste tipo de dispositivos irá aumentar de 14 milhões de unidades registadas no presente ano (2013), para cerca de 171 milhões em 2016, sendo esta previsão conservadora, segundo o analista da IMS Research, Theo Ahadome [15]. A maioria dos dispositivos portáteis está atualmente projetada para questões de saúde, como a monitorização do nível de glicose e batimento cardíaco. O objetivo deste trabalho passa por definir e implementar um dispositivo wearable para aplicações de saúde com um conjunto de funcionalidades para monitorização dos sinais vitais do utilizador. Posteriormente esta base pode ser aplicada em cenários de aplicação distintos, em que todos os dispositivos comunicam entre si, e fazem o reencaminhamento da informação para onde mais interessar. Foi desenhado e implementado hardware e software, para a construção de aplicações capazes de realizar a monitorização do batimento cardíaco, temperatura e humidade corporal, deteção de quedas, qualidade do sono, e chamadas de emergência. Este trabalho aborda os diferentes cenários e aplicações da utilização deste dispositivo, invocando as necessidades específicas de cada situação, sendo estas necessidades trabalhadas e transformadas em características e especificações do sistema. A plataforma de hardware e software permite criar um ecossistema de aplicações, permitindo usar todas as infraestruturas do sistema desenvolvido em futuros cenários de aplicação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Currently, due to the widespread use of computers and the internet, students are trading libraries for the World Wide Web and laboratories with simulation programs. In most courses, simulators are made available to students and can be used to proof theoretical results or to test a developing hardware/product. Although this is an interesting solution: low cost, easy and fast way to perform some courses work, it has indeed major disadvantages. As everything is currently being done with/in a computer, the students are loosing the “feel” of the real values of the magnitudes. For instance in engineering studies, and mainly in the first years, students need to learn electronics, algorithmic, mathematics and physics. All of these areas can use numerical analysis software, simulation software or spreadsheets and in the majority of the cases data used is either simulated or random numbers, but real data could be used instead. For example, if a course uses numerical analysis software and needs a dataset, the students can learn to manipulate arrays. Also, when using the spreadsheets to build graphics, instead of using a random table, students could use a real dataset based, for instance, in the room temperature and its variation across the day. In this work we present a framework which uses a simple interface allowing it to be used by different courses where the computers are the teaching/learning process in order to give a more realistic feeling to students by using real data. A framework is proposed based on a set of low cost sensors for different physical magnitudes, e.g. temperature, light, wind speed, which are connected to a central server, that the students have access with an Ethernet protocol or are connected directly to the student computer/laptop. These sensors use the communication ports available such as: serial ports, parallel ports, Ethernet or Universal Serial Bus (USB). Since a central server is used, the students are encouraged to use sensor values results in their different courses and consequently in different types of software such as: numerical analysis tools, spreadsheets or simply inside any programming language when a dataset is needed. In order to do this, small pieces of hardware were developed containing at least one sensor using different types of computer communication. As long as the sensors are attached in a server connected to the internet, these tools can also be shared between different schools. This allows sensors that aren't available in a determined school to be used by getting the values from other places that are sharing them. Another remark is that students in the more advanced years and (theoretically) more know how, can use the courses that have some affinities with electronic development to build new sensor pieces and expand the framework further. The final solution provided is very interesting, low cost, simple to develop, allowing flexibility of resources by using the same materials in several courses bringing real world data into the students computer works.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O processo de hidrofugação é definido como um tratamento efetuado com gorduras e agentes químicos, nomeadamente polímeros e acrílicos que dão características de lubrificação e propriedades hidrofóbicas ao material, cujas etapas são adicionadas na fase de recurtume. Um dos objetivos principais foi a obtenção de um couro com alto grau hidrofóbico, isto é um couro com baixo poder de absorção da água, resistência a sua penetração e conservação da permeabilidade ao vapor de água, sem a utilização do sal de crómio na fase de fixação, e mais pelas problemáticas ambientais que existem na atualidade com o uso deste metal no mundo dos couros. É de salientar que, o único parâmetro que foi possível analisar, de acordo com a disponibilidade do laboratório foi a percentagem de absorção da água. Portanto, para este trabalho escrito foram desenhadas uma série de ensaios, onde se testaram inúmeros produtos utilizados na indústria de produção dos couros, alterando-se fatores de temperatura, dosagem, posição dos produtos aplicados, tempos, entre outros parâmetros, de modo a obter um couro com melhores resultados na percentagem de absorção. A hidrofugação é um processo bastante delicado e mais quando se tenta produzir um couro isento de metais e com alto poder hidrofóbico. Os resultados obtidos experimentalmente apontam para uma percentagem de absorção de cerca de 30% para espaços de tempo de 10 minutos, utilizando sempre sais de alumínio na etapa de fixação, pelo que ainda se requer mais investigação para obter um couro wet-white sem adição de sais metálicas e com alto poder de absorção.