7 resultados para ANTIBACTERIAL MONOMER
em Instituto Politécnico do Porto, Portugal
Resumo:
As quinoxalinas são compostos heterocíclicos que têm, entre outras, capacidades antimicrobianas, inclusivamente contra bactérias resistentes aos antimicrobianos convencionais. Os mecanismos pelos quais estes compostos exercem a sua atividade ainda não está completamente esclarecido. O objetivo do presente estudo é avaliar o efeito redox em sinergismo/antagonismo com as quinoxalinas em modelos de bactérias com e sem resistências a antimicrobianos. No que se refere aos compostos foram utilizados a quinoxalina 1,4-dióxido (QNX), 2-metil-3-benzilquinoxalina-1,4-dióxido (2M3BQNX), 2-metilquinoxalina-1,4-dióxido (2MQNX) e a 2-amino-3-cianoquinoxalina-1,4-dióxido (2A3CQNX). Quanto aos modelos procariotas, foram utilizados a Salmonella enterica, Klebsiella pneumoniae, Enterococcus faecalis, Staphylococcus saprophyticus, Enterobacter aerogenes, Enterobacter cloacae, Staphylococcus aureus ATCC 25923, Methicillin-resistant Staphylococcus aureus ATCC 43300, Escherichia coli TEM 201 e Escherichia coli TEM 180. Nos compostos químicos em que se verificou a Concentração Mínima Inibitória (CMI), realizou-se o estudo do comportamento do crescimento bacteriano. Relativamente ao estado redox, foi avaliado para cada estirpe sensível, através do rácio GSH/GSSG, nas doses inibitórias e não inibitórias de cada composto. Os resultados apresentam que todos os compostos testados, à exceção do 2M3BQNX, têm atividade antimicrobiana na maioria das estirpes, excetuando a E. faecalis e a S. saprophyticus. Os rácios GSH/GSSG apontam para o efeito oxidante em K. pneumoniae e S. enterica e antioxidante na E. aerogenes. A conclusão do estudo sugere que os compostos apresentam elevada capacidade antibacteriana e influência no equilíbrio redox das bactérias, podendo contribuir para o esclarecimento do mecanismo de ação dos derivados das quinoxalinas 1-4 dióxido, nas bactérias.
Resumo:
O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.
Resumo:
A novel artificial antibody for troponin T (TnT) was synthesized by molecular imprint (MI) on the surface of multiwalled carbon nanotubes (MWCNT). This was done by attaching TnT to the MWCNT surface, and filling the vacant spaces by polymerizing under mild conditions acrylamide (monomer) in N,N′-methylenebisacrylamide (cross-linker) and ammonium persulphate (initiator). After removing the template, the obtained biomaterial was able to rebind TnT and discriminate it among other interfering species. Stereochemical recognition of TnT was confirmed by the non-rebinding ability displayed by non-imprinted (NI) materials, obtained by imprinting without a template. SEM and FTIR analysis confirmed the surface modification of the MWCNT. The ability of this biomaterial to rebind TnT was confirmed by including it as electroactive compound in a PVC/plasticizer mixture coating a wire of silver, gold or titanium. Anionic slopes of 50 mV decade−1 were obtained for the gold wire coated with MI-based membranes dipped in HEPES buffer of pH 7. The limit of detection was 0.16 μg mL−1. Neither the NI-MWCNT nor the MWCNT showed the ability to recognize the template. Good selectivity was observed against creatinine, sucrose, fructose, myoglobin, sodium glutamate, thiamine and urea. The sensor was tested successfully on serum samples. It is expected that this work opens new horizons on the design of new artificial antibodies for complex protein structures.
Resumo:
As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1 × 10−5 and 5.5 × 10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.
Resumo:
The indiscriminate use of antibiotics in food-producing animals has received increasing attention as a contributory factor in the international emergence of antibiotic-resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOX-selective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9 × 10−5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.
Resumo:
A furazolidona é uma substância ativa do medicamento Giarlam que contém um espetro anti-bacteriano relativamente amplo e que é frequentemente usado para tratar certas doenças bacterianas e protozoárias no homem. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabólitos exige o desenvolvimento constante de métodos analíticos eficientes. Neste trabalho desenvolveu-se um novo sensor eletroquímico para a deteção da furazolidona, baseado num elétrodo de pasta de carbono modificado com um polímero molecularmente impresso. A procura de novos materiais que permitam uma melhor seletividade e sensibilidade aos sistemas de deteção é especialmente importante no desenvolvimento de métodos analíticos. Os polímeros molecularmente impressos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais frequente como ferramenta importante em química analítica. Assim, sintetizou-se um polímero com cavidades seletivas para a Furazolidona. Este polímero foi, misturado com grafite e perafina de modo a produzir uma pasta de carbono. Uma seringa de plástico foi usada como suporte da pasta de carbono. O comportamento eletroquímico do sensor foi avaliado e diversas condições de utilização foram estudadas e otimizadas. O sensor apresenta um comportamento linear entre a intensidade do pico e a concentração numa gama de concentrações entre 1 e 100 μM, um limite de deteção de 1 μM e uma precisão (repetibilidade) inferior a 7%. A aplicabilidade do sensor fabricado em amostras complexas foi avaliada pela deteção do fármaco em amostras de urina.
Resumo:
Eight tropical fruit pulps from Brazil were simultaneously characterised in terms of their antioxidant and antimicrobial properties. Antioxidant activity was screened by DPPH radical scavenging activity (126–3987 mg TE/100 g DW) and ferric reduction activity power (368–20819 mg AAE/100 g DW), and complemented with total phenolic content (329–12466 mg GAE/100 g DW) and total flavonoid content measurements (46–672 mg EE /100 g DW), whereas antimicrobial activity was tested against the most frequently found food pathogens. Acerola and açaí presented the highest values for the antioxidant-related measurements. Direct correlations between these measurements could be observed for some of the fruits. Tamarind exhibited the broadest antimicrobial potential, having revealed growth inhibition of Pseudomonas aeruginosa. Escherichia coli, Listeria monocytogenes, Salmonella sp. and Staphylococcus aureus. Açaí and tamarind extracts presented an inverse relationship between antibacterial and antioxidant activities, and therefore, the antibacterial activity cannot be attributed (only) to phenolic compounds.