4 resultados para 208-1265D

em Instituto Politécnico do Porto, Portugal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present research paper presents five different clustering methods to identify typical load profiles of medium voltage (MV) electricity consumers. These methods are intended to be used in a smart grid environment to extract useful knowledge about customer’s behaviour. The obtained knowledge can be used to support a decision tool, not only for utilities but also for consumers. Load profiles can be used by the utilities to identify the aspects that cause system load peaks and enable the development of specific contracts with their customers. The framework presented throughout the paper consists in several steps, namely the pre-processing data phase, clustering algorithms application and the evaluation of the quality of the partition, which is supported by cluster validity indices. The process ends with the analysis of the discovered knowledge. To validate the proposed framework, a case study with a real database of 208 MV consumers is used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Distributed Energy Resources (DER) scheduling in smart grids presents a new challenge to system operators. The increase of new resources, such as storage systems and demand response programs, results in additional computational efforts for optimization problems. On the other hand, since natural resources, such as wind and sun, can only be precisely forecasted with small anticipation, short-term scheduling is especially relevant requiring a very good performance on large dimension problems. Traditional techniques such as Mixed-Integer Non-Linear Programming (MINLP) do not cope well with large scale problems. This type of problems can be appropriately addressed by metaheuristics approaches. This paper proposes a new methodology called Signaled Particle Swarm Optimization (SiPSO) to address the energy resources management problem in the scope of smart grids, with intensive use of DER. The proposed methodology’s performance is illustrated by a case study with 99 distributed generators, 208 loads, and 27 storage units. The results are compared with those obtained in other methodologies, namely MINLP, Genetic Algorithm, original Particle Swarm Optimization (PSO), Evolutionary PSO, and New PSO. SiPSO performance is superior to the other tested PSO variants, demonstrating its adequacy to solve large dimension problems which require a decision in a short period of time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The large increase of Distributed Generation (DG) in Power Systems (PS) and specially in distribution networks makes the management of distribution generation resources an increasingly important issue. Beyond DG, other resources such as storage systems and demand response must be managed in order to obtain more efficient and “green” operation of PS. More players, such as aggregators or Virtual Power Players (VPP), that operate these kinds of resources will be appearing. This paper proposes a new methodology to solve the distribution network short term scheduling problem in the Smart Grid context. This methodology is based on a Genetic Algorithms (GA) approach for energy resource scheduling optimization and on PSCAD software to obtain realistic results for power system simulation. The paper includes a case study with 99 distributed generators, 208 loads and 27 storage units. The GA results for the determination of the economic dispatch considering the generation forecast, storage management and load curtailment in each period (one hour) are compared with the ones obtained with a Mixed Integer Non-Linear Programming (MINLP) approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

De forma a proteger o ambiente e a saúde humana, é imperativo evitar, prevenir ou reduzir as concentrações prejudiciais de poluentes nocivos na água subterrânea. A necessidade da obtenção de níveis de protecção da água subterrânea, encontra-se estabelecida em normas de qualidade e devem ser desenvolvidas metodologias que permitam a avaliação do estado químico da água subterrânea. Este trabalho experimental centrou-se no desenvolvimento de uma metodologia analítica de detecção e quantificação por cromatografia gasosa com detector de captura de electrões dos pesticidas atrazina e respectivos metabolitos (desetilatrazina e deisopropilatrazina), simazina, terbutilazina e o metabolito desetiterbutilazina, folpete, dimetoato, diazinão, malatião, cloropirifos e o azinfos-metilo em águas de poços. O estudo progressivo baseou-se na colheita de água a 20 poços agrícolas na zona de Esposende, área considerada pelo Ministério da Agricultura do Desenvolvimento Rural e Pescas como sendo uma zona vulnerável. O método utilizado para a validação da técnica cromatográfica baseou-se na norma ISO 8466-1:1990. Os parâmetros de validação considerados foram: especificidade/selectividade, capacidade de identificação, limites de detecção e quantificação, relação sinal/ruído, linearidade e curva de calibração, precisão (repetibilidade, precisão intermédia e reprodutibilidade), eficiência de extracção e arrastamento. O método demonstrou ser capaz de identificar e quantificar os analitos, sem interferência de outros compostos. Obteve-se um valor para os parâmetros da precisão inferior a 10%, enquanto os mais baixos limites de detecção e de quantificação foram, respectivamente, 0,014 e 0,047 μg L-1. Na preparação de amostras optou-se pelo método de extracção em fase sólida, tendo sido testadas cinco diferentes tipos de colunas extractivas; Lichrolut® EN/RP-18; Strata SDB-L e C18-E; Chromabond HR-P e HR-X, sendo que as colunas Lichrolut® EN/RP- 18 apresentaram melhores resultados para a globalidade dos pesticidas. Da análise efectuada aos 20 poços agrícolas verificou-se que apenas 3 não apresentavam qualquer vestígio dos pesticidas monitorizados, sendo que as restantes apresentavam valores entre 0,05 e 53,2 μg L-1, valores superiores aos impostos pela legislação em vigor (Decreto-Lei n.º 208/2008 de 28 de Outubro para água subterrânea e Decreto-Lei nº306/2007 referente a água para consumo). Verificou-se que os proprietários dos poços agrícolas, dos quais se procedeu à amostragem de água para análise não têm a consciência da falta de qualidade dessa água, nem dos malefícios que possam advir do seu consumo.